| Sl No | Description | Qty | Unit | MOOGAMBIGAI ENGINEERING WORKS L1 | VASANTHA ENGINEERING WORKS L2 |
|---|---|---|---|---|---|
| 1.00 | Charges for carrying out periodical preventive maintenance works in horizontal split casing Fire Hydrant Pump model 8A 20B such as correcting the alignment of pump with motor, dismantling and removing of chokes in the auxiliary piping connections and re-fixing, dismantling split packing glands in DE & NDE reconditioning, replacement of gland ropes & re-fixing glands, lubricating the pump and motor with fresh lubricants, removal of terminal cover and fan cover of motor and correcting the looseness/removal of fuel filters, cleaning, attending leaks and trial run including the cost of consumables and T&P hire charges. | 28 | operation | 3,740 ₹1,04,720 Lowest | 5,000 ₹1,40,000 |
| 2.00 | Charges for carrying out periodical preventive maintenance works in Jockey pump such as correcting the alignment of pump with motor, dismantling and removing of chokes in the strainers and re-fixing, dismantling the packing glands in DE & NDE reconditioning, replacement of gland ropes & re-fixing glands, lubricating the pump and motor with fresh lubricants, removal of terminal cover and fan cover of motor and correcting the looseness and trial run including the cost of consumables and T&P hire charges. | 8 | operation | 2,043 ₹16,344 Lowest | 3,000 ₹24,000 |
| 3.00 | Charges for carrying out periodical preventive maintenance works in sluice valves (300 dia 6- 8 no)/ NRV’s (300 dia -5 nos.) in Fire protection system in the Raw water pump house such as replacement of gland ropes, gaskets, worn-out bolts & nuts and thorough cleaning of overhead headers of Fire Protection System including cost of consumables and T&P hire charges. | 12 | operation | 2,833 ₹33,996 Lowest | 3,000 ₹36,000 |
| 4.00 | Attending puncture in RC lines fire Hydrant /HVWS pumps by patch welding including electrodes, gas, consumables and T&P hire charges but excluding electricity charges. | 200 | inches | 377 ₹75,400 Lowest | 400 ₹80,000 |
| 5.00 | Charges for attending gland/gasket leaks in sluice valves of 100-200 NB in Hydrant/HVWS system in various location of plant area by replacement of worn-out gland rope/gaskets including cost of consumables and T&P hire charges. | 160 | Nos. | 681 ₹1,08,960 Lowest | 700 ₹1,12,000 |
| 6.00 | Charges for removal of scrub jungle grown on the sand and consolidating the sand kept for fire quenching in 3 locations in plant area including cost of T&P and consumables. | 6 | Activity | 6,648 ₹39,888 Lowest | 7,000 ₹42,000 |
| 7.00 | Charges for rectification of defects in fire hydrant valves by closing the nearby isolation valves, dismantling the safe guard arrangements, releasing the valve, thorough cleaning, replacing the worn out internals and re fixing the valve, safe guard arrangement intact and painting including cost of consumables and T&P hire charges. | 100 | Nos. | 1,906 ₹1,90,600 Lowest | 2,000 ₹2,00,000 |
| 8.00 | Charges for engine oil and Gear box oil replacement / topping up of diesel in the Fire Protection diesel engine overhead tanks erected in RWPH by drawal from stores through barrels, filling in the tanks by hand pumps including cost of transportation, T&P and consumables charges | 8 | Activity | 4,465 ₹35,720 Lowest | 5,000 ₹40,000 |
| 9.00 | Charges of tightness checking for each cells and battery terminals, measurement of cell voltage applying petroleum jelly & top up of DM water for all batteries. | 12 | Activity | 1,679 ₹20,148 Lowest | 2,000 ₹24,000 |
| 10.00 | Charges for attending breakdown work in 200/150 NB sluice valve by overhauling and replacing of flange gaskets of Underground (in valve pits)/Above ground sluice valve in fire hydrant system by releasing the valve, dismantling, thorough cleaning, removing the foreign materials, lapping the gate and its seating, renewal of worn-out gland, gaskets and painting and reassembling intact and erection of the same including cost consumables and T&P hire charges. | 8 | Nos. | 7,800 ₹62,400 Lowest | 8,000 ₹64,000 |
Tender Value
Refer Docs
EMD Value
₹7,700
Closing Date
7 Aug 2025, 2:00 pmClosed
The Chief Engineer
The Chief Engineer, North Chennai Thermal Power Station - I, Chennai - 120
NCTPS I Operation Circle O and E Division Fire Fighting Carrying out periodical preventive maintenance works in fire protection pumps Sluice valves of Hydrant and HVWS system for a period of one year from the date of handing over of site
2025_EB_585097_1
CE/NCTPS-I/SE/OPN/38/2025-26
Open Tender
Power/Energy Projects/Products
Works
365 days
NCTPS - I
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹7,700
Yes
24 Oct 2025
24 Jul 2025
8 Aug 2025
24 Jul 2025
7 Aug 2025
24 Jul 2025
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .