| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹53.6 LAccepted-AOC AT BHADHIYA DIST GODDA | GODDA | JHARKHAND | ₹53.6 L | L 1 | Accepted-AOC L1 Bidder |
| 2 | L 2₹54.4 L+₹81,561.66 (1.52%)Rejected-AOC AT TINGHARA JAMA DIST DUMKA | JAMA | DUMKA | JHARKHAND | ₹54.4 L+₹81,561.66 (1.52%) | L 2 | Rejected-AOC L 2 Bideer |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical 1 ST FLOOR HARIPRIYA RANI BAGAN BARIYATU RANCHI | RANCHI | JHARKHAND | 829205 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹54.5 L
EMD Value
₹1.1 L
Closing Date
29 Apr 2026, 5:00 pmClosed
E.E D.W AND S.DIVISION,GODDA
E.E D.W AND S.DIVISION,GODDA
Supply and Installation of Solar Submersible DC Water Motor Pump 1 HP, HDPE tank, new starter, Stand post, Rising and Delivery Pipe line Arrangement, DT 120m and 60 mtrs (200 ft) deep gravel packed tube well with installation of india mark-ii hand pu
2026_DWSD_113249_1
Tender Notice Reference no. 02 / DWSD/GOD/ 2026-27
Open Tender
Civil Works
Works
60 days
E.E D.W AND S.DIVISION
Poraiyahat block
2 documents required · 2 mandatory
₹10,000
₹1.1 L
Yes
28 May 2026
23 Apr 2026
30 Apr 2026
23 Apr 2026
29 Apr 2026
23 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Designing , Supplying , Installation , Testing & Commissioning with all tools & parts of following Solar Photovoltaic (SPV) Solar submersibble DC water motor pump suitable for minimum 125 mm X 115 mm bore well as per MNRE guideline with following specifications & accessories. | - | - | - | - |
| 2 | SPV arrays contains specified no of sample capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 Watt peak. | - | - | - | - |
| 3 | i) The SPV modules should be as per IEC-61215 and IEC-61730 part 1.0 | - | - | - | - |
| 4 | ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required. | - | - | - | - |
| 5 | iii)The PV Modules should be mounted on metallic structure of adequate strength &appropriate design which can withstand load of modules & high wind pressure up to 200 kmph. | - | - | - | - |
| 6 | iv)The module mounting structure should be hot dip galvanized according to IS 4759. | - | - | - | - |
| 7 | v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle adjustment should be provided. | - | - | - | - |
| 8 | vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. ( As per MNRE specification) | - | - | - | - |
| 9 | vii) Necessary protection such as lightening arrestor etc should be provided to protect the controller & SPV . | - | - | - | - |
| 10 | viii) The suction/delivery pipe shall be UPVC/HDPE pipes of appropriate size 60 m or more as required minimum pressure rating of 8 kg/sq cm - PE 100 grade for pump upto 3 HP & 10 kg/sq cm - PE 100 grade for 5 HP. | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Technical.pdf
Tender Documents • 0.84 MB
BOQ_152924.xls
BOQ • 0.35 MB
Corrigendum.pdf
PDF • 3.04 MB
Corrigendum.pdf
PDF • 3.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .