Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | ₹35.5 L Quoted ₹35.9 L | L1 | Accepted-AOC Being overall reasonable |
| 2 | L2₹41.7 L+₹5.8 L (16.0%)Rejected-Finance | ₹41.7 L+₹5.8 L (16.0%) | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹42.0 L+₹6.1 L (16.9%)Rejected-Finance SR NO 281 3 7 ANAND NAGAR NEAR DHANORI JAKAT NAKA LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | ₹42.0 L+₹6.1 L (16.9%) | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹42.5 L+₹6.6 L (18.4%)Rejected-Finance | ₹42.5 L+₹6.6 L (18.4%) | L4 | Rejected-Finance Not lowest bidder |
| 5 | L5₹42.5 L+₹6.6 L (18.4%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | ₹42.5 L+₹6.6 L (18.4%) | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
21 Sept 2024, 6:00 pmClosed
GE CENTRAL KHADKI
GE CENTRAL KHADKI RANGE HILLS ROAD KHADKI PUNE-411003
SPECIAL REPAIRS TO OH CONDUCTOR TO UG CABLE AT BEG AND CENTRE UNDER AGE E/M-I AT GE (CENTRAL) KHADKI.
2024_MES_668580_1
8974/E8 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
BEG AND CENTRE area
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE CENTRAL KHADKI
₹87,400
Yes
15 Oct 2024
31 Aug 2024
24 Sept 2024
31 Aug 2024
21 Sept 2024
14 Sept 2024
31 Aug 2024 - 9 Sept 2024
Amount
Dismantling cross arms of MS channel or angle sections etc complete all as specified and as directed.
Dismantling insulator any type, any size complete complete all as specified and as directed.
Dismantling of ACSR conductor any type any size complete all as specified and as directed.
Excavation in trenches nexc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in hard/dense soil for laying cables, erection of poles complete all as specified and directed by Engr-in-Charge
Returning, filling in including spreading, levelling, watering and ramming in layers not exc 25 cm each in soil complete all as specified and directed by Engr-in-Charge
Removing surplus excavated soil to a distance n. exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge
Material and labour for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, XLPE insulated, armoured, heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, heavy duty cable served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq.mm 2 core complete all as specified and as directed.
Description all as per item No. 8 above but 16 sqmm 4 core cable complete all as specified and as directed.
Description all as per item No. 8 above but 25 sqmm 3.5 core cable complete all as specified and as directed.
Description all as per item No. 8 above but 35 sqmm 3.5 core cable complete all as specified and as directed.
Description all as per item No. 8 above but 50 sqmm 3.5 core cable complete all as specified and as directed.
Description all as per item No. 8 above but 95 sqmm 3.5 core cable complete all as specified and as directed.
Description all as per item No. 8 above but 120 sqmm 3.5 core cable complete all as specified and as directed.
Description all as per item No. 8 above but 240 sqmm 3.5 core cable complete all as specified and as directed.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cable of size 40 mm outer dia with all fittings such as clamps. coupler etc laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) MAKE :- Alcorr / Rex / Gemini or its equivalent
Description all as per item No.16 above but of size 50mm outer dia
Description all as per item No. 16 above but of size 63mm outer dia
Description all as per item No. 16 above but of size 90mm outer dia
Description allas per item No. 16 above but of size 120mm outer dia
Supply and fix GFRP pole 7 mtr length flanged type manufactured using sophisticated multi axes Siemens controlled CNC filament winding machines using E Class Fibers having Glass content of 65 to 70 percent. Top OD 105 mm and Bottom Od 215 mm, overall thickness of 8 mm with overall tolerance for length +/- 25 mm. and tolerance for overall thickness +/- 0.5 mm. Poles to be finished on the outside with UV inhibitors in accordance with ASTM G 154,Izod Impact Strength of 80 k/Jm2, Barcol Hardness of 45 BHU, Tensile Modulus of 9000 MPa, Surface Resistivity of 1.6*1016Ω, Volume Resistivity of 4.05*1013Ωcm, Tensile Modulus of Elasticity 22918 N/mm2, Wind Speed sustainability to be 180 KMPH, Flammability test which confirms to V0 rating of UL 94. TUV certification, Batch wise Test report, LOGO incorporation complete all as specified and directed by Engr-in-charge. MAKE :- Helipole Cat part no CTRF- RF-7-105-A 1-SF or its technocommercial equivalent in Bajaj/Philips.
Supply and fix GFRP Double arm of length 1 mtr for mounting of street light fittings as per design approved by Engr-in-Charge complete all as specified and directed. MAKE :- Helipole or its technocommercial equivalent in Bajaj/Philips.
Supply and fix thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection complete all as specified and directed by Engr-in-Charge. MAKE :- Hensel Cat No.DK 2525G or its techno commercial equivalent in Sintex/Neptune.
Material and labour for timer dial type suitable for panel mounting complete all as specified and directed by Engr-in-Charge.
Material and labour for 3 pole contactor 40 Amps capacity 50 HZ up to 415 volt, complete all as specified and directed by Engr-in-Charge. MAKE :- L&T/Legrand/C&S.
Supply and fix Hybrid AIO Gen2 powered by solar energy and at the same time connected to the electric grid LED Street light 50 Watt IP 66 rating with lumen output 120 lm/watt housing made of die-cast aluminium with street optic lens and glass diffuser for uniform light distribution incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole complete all as specified and directed by Engr-in-Charge. MAKE :- Philips Cat No. BRP111 LED50/757 M Solar HY or its technocommercial equivalent in Wipro/Crompton/Osram.
Material and labour for heat shrink straight through joint LT 1100 volts grade for cable of size 25-50 sqmm, 4 core, complete all as specified and directed.
Material and labour for heat shrink straight through joint LT 1100 volts grade for cable of size 70-150 sqmm, 4 core, complete all as specified and directed.
Material and labour for cable route indicator duly embossed ' MES LT CABLE" 1100 volts on 80mm dia CI Plate marked on LT Cable bolted with 40x5mm flat iron of height 0.4mtr embedded in PCC 1:3:6 type C2 of size 20x20x30 cm block complete all as specified and directed.
Material and labour for three core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) all as specified and directed.
Material and labour for rigid non-mettalic PVC conduit of size 20mm inclusive of all fittings i.e. tees,bends,elbows, bell mount tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engr-in-Charge
Material and labour for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x6 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion all as directed.
Material and labour for outdoor type LT Panel of size 1100 mmX1950 mmX660 mm 415 Volts AC 50 Hz, fabricated from Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anticorrosive and confirming to Protection Class II with IP 65 according to IEC 60529 and internally embedded gasket made of polyurethane, flame retardant self existinguishing with glow wire test at 960 degreeC in accordance with IEC 60695-2-11 with impact strength IK 08 (5 Joule) in accordance with DIN EN 50102 complete including copper bus bar of size 25x10mm and internal prewired with following provn :- (a) Incoming MCCB 4 Pole 250 Amps 25 KA Rotary Handle type- 01 No. (b) Outgoing MCCB 63 Amps 10 KA 3pole - 04 Nos (c) Outgoing MCB TPN 63 Amps B Curve - 02 Nos (d) Outgoing MCB DP 63 Amps B Curve - 02 No (e) 65A TP Contactor - 01 No (f) Timer dial type - 01 No. (g) MFM - 01 No NOTE : - (i) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI in respect of LT Panel Make of Panel :- Hensel/Neptune/Hager/L&T Make of MCCB/MCB :- Legrand/L&T/C&S
Material and labour for outdoor type LT Panel of size 1100 mmX1950 mmX660 mm 415 Volts AC 50 Hz, fabricated from Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anticorrosive and confirming to Protection Class II with IP 65 according to IEC 60529 and internally embedded gasket made of polyurethane, flame retardant self existinguishing with glow wire test at 960 degreeC in accordance with IEC 60695-2-11 with impact strength IK 08 (5 Joule) in accordance with DIN EN 50102 complete including copper bus bar of size 25x10mm and internal prewired with following provn :- (a) Incoming MCCB 4 Pole 250 Amps 25 KA Rotary Handle type- 01 No. (b) Outgoing MCCB 3 pole 100 Amps 25 KA Rotary Handle type - 01 No (c) Outgoing MCCB 3 pole 63 Amps 10 KA Rotary Handle - 03 Nos (d) Outgoing MCB TPN 63 Amps B Curve - 02 Nos (e) Outgoing MCB DP 32 Amps B Curve - 02 No (f) Analog timer - 01 No (g) 63 A TP Contactor - 01 No. (f) MFM - 01 No NOTE :- (i) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI in respect of LT Panel Make of Panel :- Hensel/Neptune/Hager/L&T Make of MCCB/MCB :- Legrand/L&T/C&S
(Item No.35 Contd.....) (g) MCCB 63 Amps, 3 Pole, 10 KA with adjustable thermal & fixed Magnetic settings - 04 Nos (Outgoing). (h) MCB TP 63 Amps B Curve - 02 Nos (Outgoing) (j) MCB DP 63 Amps B Curve - 02 Nos (Outgoing) (k) 65A TP Contactor - 01 No (l) Timer dial type - 01 No. (m) MFM - 01 No NOTE :- (i) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI in respect of LT Panel Make of Panel :- BCH/Neptune/Hager/L&T Make of MCCB/MCB :- Legrand/L&T/C&S
(Item No.37 Contd.....) (g) MCCB 125 Amps, 3 Pole, 16 KA with adjustable thermal & fixed Magnetic settings - 02 Nos (Outgoing). (h) MCCB 100 Amps 3 pole , 10 KA with adjustable thermal & fixed Magnetic settings - 02 Nos (Outgoing) (j ) MCB TPN 63 Amps B Curve - 02 Nos NOTE :- (i) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI in respect of LT Panel Make of Panel :- BCH/Neptune/Hager/L&T Make of MCCB/MCB :- Legrand/L&T/C&S
MANGAL ELECTRICAL STORES (BID ID -3103636)
VP DEVELOPERS AND CONTRACTOR (BID ID -3105087)
Om Construction (BID ID -3103395)
ASHWAMEDH ENGINEERS (BID ID -3104663)
JP ENTERPRISES (BID ID -3104155)
M/S. Niksun Electro-Infra Private Limited (BID ID -3104225)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .