| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹43.6 L+₹23,091 (0.53%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Jan 2025, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
PERIODICAL MAINT OF FIRE ALARM, EOT CRANES AND OTHER MISC ITEMS AT 19 WING AND 14 BRD UNDER GE (AF) BORJHAR
2024_MES_686524_1
8461/BOR/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Borjhar
MES contractor enlisted as Class D category b(i) having deposited Standing Security of Rs 100000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹80,000
Yes
29 Mar 2025
30 Nov 2024
5 Jan 2025
30 Nov 2024
2 Jan 2025
14 Dec 2024
Amount
Comprehensive Service/Repair/maintenance and monthly visit for regular maintenance for the Automation of intelligent addressable fire alarm control panel at 118HU hanger, 59 SQN hanger, CNGO Complex Hanger , BCR Building, AFNET site -2, and EE hall, Logistic Section,Base Ops including checking testing and cleaning of Loop card ,Main board, LCD display, Multisensor, sounder, MCP, , Repeater Panel, Zone monitor Module, UV&IR detector, Remote Response indicator, Loop Isolator, Amplifier and Loud speakers carrying out normal repairs for the trouble free and efficient functioning of the entire fire alarm system by providing one engineer for Monthly visit all as directed AND AS PER SPECIFIED NFPA 72 and Guidelines. Note:- (i) Cost of new components shall be paid for separately under relevant items of schedule 'A" (ii) Contractor's rep will visit minimum once in a month to every panel each locationasmentionedabove and take serviceability certificate duly signed by the user.
Dismantling, Servicing of multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling every six month complete all as specified and as directed.
Serviceability and Testing of UV & IR flame detector and its alignment to detect flame with Testing Kit and when directed complete all as specified and as directed.
Supply & fix in repairs 12 V, 7 AH battery for Inverter supply for back up to all FACP panel complete all as specified and as directed. Make: EXIDE/AMAR RAJA/AMCO/AMARON
Supply and Fixing in repair or replacement of Indoor addressable detectors complying with and type certified to EN-54 Addressable type multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence complete all as specified and as directed. Make:- GST/COOPER/BOSCH/SEIMENS
Supply anf Fixing of electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a) Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current) b) Class A , c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key, d) Ingress Protection IP-43 & Material-ABS Make:- GST/COOPER/BOSCH/SEIMENS
Supply and Fixing of the annunciating device Remote response indicator complete all as specified and directed. Make:- GST/BOSCH/SEIMENS
Supply and Fixing of fire alarm sounder/sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65db to 120db measured at 1.5 m with sound output variation of +5db 500m range complete all as specified and directed. Make:- GST/COOPER/BOSCH/SEIMENS
Supply and Fixing of the indoor detector complying with and type certified to EN - 54 Addressable type flame detectors with UV and IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module) with self built intelligence complete all as specified and directed. Make: SIEMENS/AGNI/GST/HONEYWELL
Supply anf Fixing of Zone Monitor Module compatible with Fire Alarm Control Panel complete all as specified and as directed. Make: GST/COOPER/BOSCH/SEIMENS
Supply anf Fixing of GST200 Rubber Keypad F7.843.249 for FACP complete all as specified and as directed.
Supply and Fixing of GST200 Loop Interface Board F2.908.828 (RoHS) for FACP complete all as specified and as directed.
Supply and Fixing of GST200 Power Supply Unit F2.932.069 (20100682) for FACP complete all as specified and as directed.
Supply and Fixing of Transformer 220V/27V-100W-R for FACP complete all as specified and as directed.
Supply and Fixing of two core copper conductor of size 1.5sqmm FRLSH flexible shielded cable complete all as specified and directed. Make: HAVELLS INDIA LTD/INDIA LTD INDO AMERICAN ELECTRICALS FINOLEX/ NICCO/KEI/POLYCAB/RR KABLE LTD
Supply and fixing of SMPS Adapter 24 Volt 2.0 Amp Make- protek
Supply And Fixing RS 485 Network Card for fire alarm control Panel Make- GST
Supply and Fixing Media Convertor for RS 485 to Fiber Optic convertor Make-GST
M&L for detection of OFC cable fault through OFC cable fault locator all as specified and directed.
M&L for jointing the damage OFC cable through OFC cable Jointing Kit complete all as specified and directed. Note:- Any earth work, sand cushioning & brick protection for OFC cable shall be measured & paid separately.
Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through maually.
Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for sand cushioning for protection of lT under ground cable with screen wash sand and punning to proper reqd cover all as specified and directed.
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate all as specified and directed.
S&F PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 2 Core.
S&F PVC insulated, Unarmoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 2.5 sq. mm 3 Core.
S&F Rigid non-metallic PVC conduit of external dia 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
M&L of UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area incl lugs of size 25 sq mm 3.5 core complete all as directed.
All as per above item no.31 but size 16 sqmm 4 core complete all as directed.
S&L in repair of UG cable XLPE insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross section area incl taking down of size 10 Sqmm 2 core complete all as directed.
M&L for boring under roads or any other specified location by reqd T&P without disturbing the top surface of the road for insertion of GI Pipe of 50 to 100 mm dia etc complete all as specified and directed.
M&L for tubes 50 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed. Make- Nezone/ Bansal/ Jindal
M&L for HDPE Double wall corrugated pipe of size 63/50 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/wall for protection cables complete all as specified and directed.
S&F Double wall corrugated pipe coupler for pipe size 63/50 mm all as directed by Engr-in-Charge.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft loose soil.
M&L for Brickwork with subclass B bricks straight or curved on plan exc 6m mean radius, built in CM(1:4) complete all as specified and as directed.
Removing excavated material exc. 250m but n exc. 500m and depositing where directed.
M&L for 15 mm thick rendering in CM (1:6) on other than fair face of brick or concrete surfaces finishing even and smooth without using extra cement.
M & L preparation of new plaster surface of walls etc and applying three coats of white washing complete all as specified and directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings Fe 410-W (Gde-E- 250) quality-B(exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete
S&F, including fabrication installation of glow sign board made out of ACP sheet of size 8'x4' fitted with the help of supporting clamps/nuts& blots fitted to stainless steel tubing 50 mm dia light grade, all around the ACP Sheet. Name of the installation/Location to be written on both side of the ACP Sheet with stenciles of good quality. This board will be fixed on the wall with and inclusive necessary arrangement all as directed by Engr-in-Charge.(Sample board is available with AGE E/M Office). Note:- Approval of each sign board shall be taken by the contractor before fabrication.
M&L for fabrication of ACP Sheet 3mm thick of size 1.5'x 2' for writing with stencils such as history of machines, manufacturers name,Srl No,Date of installation,SM No/MES No/Machine No all as directed by Engr-in-Charge. Note:-For each board, specimen shall be provided by MES Executive duly approved by Engr-in-Charge.
M&L for fixing the FRP cable junction boxes of size 205 x 255 x 112 mm, with four way connector (Heavy duty) terminals for 10 - 25 sq mm, 1100V cable, IP 66, weather proof, outdoor installation type with threaded cable glands & pole mounting brackets with one SP MCB 6 Amps etc complete all as specified & directed. Make- Hensel / OBO
M&L for fixing the FRP cable junction boxes of size 155 x 210 x 92 mm, with four way connector (Heavy duty) terminals for 10 - 16 sq mm, 1100V cable, IP 66, weather proof, outdoor installation type with threaded cable glands & pole mounting brackets with one SP MCB 6 Amps etc complete all as specified & directed. Make- Hensel / OBO
M&L for fixing the FRP cable junction boxes of size 225 x 295 x 122 mm, with four way connector (Heavy duty) terminals for 16-35sq mm, 1100V cable, IP 66, weather proof, outdoor installation type with threaded cable glands & pole mounting brackets with one SP MCB 6 Amps etc complete all as specified & directed. Make- Hensel / OBO
Material & Labour for making foundation for distribution transformer of various capacity, of size length 1500 mm, width 1500 mm and height of 1500 mm above ground level & 600 mm below ground level. The details of PCC, Bricks and plastering are as under:- (a) Cement Concrete in foundation (Hard Core) type D2, 1:4:8, 40 mm graded aggregate of length 1500 mm, width 1500 mm, thickness 150 mm. (b) Brick works above cement concrete foundation with Subclass 'B' bricks straight for foundation/staging for transformerin cement mortar 1:6 of length 1500 mm x width 1500 mm and Height 1850 mm. (c) Cement Concrete of Type B1 (1:2:4) 20 mm aggregate on top of Brick work of length 1500 mm, width 1500 mm and thickness 100 mm. (d)Rendering 10 mm thick cement plastering in 1:6 fair faces of brick work or pcc surfaces above ground all around the exposed foundation. Note: (i) Rate quoted shall inclusive of taking down/removal of existing transformer by switching off HT/LT connection and placing near by temporarily and reconnecting HT/LT and providing electrical supply. (ii) The same transformer will be re installed on newly connected staging(after 15 days) by swiching off HT/LT Connection and reconnecting the same on foundation for and providing/ swiching on electrical supply. (iii) The rate quoted shall inclusive of crane for lifting/ lowering of transformer( Two times) and dismantling of old pcc/rcc foundation of any type any size.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. (Note: The rate quoted shall inclusive of GI wire 4 mm dia with GI pipe protection 15 mm, light grade up to 7.5 m)
M/s DC Traders (BID ID -3201035)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .