Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance LAL BAZAR SRINAGAR SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Finance |
Tender Value
₹39.3 L
EMD Value
₹78,570
Closing Date
26 May 2025, 6:00 pmClosed
EE EP BSNL JAMMU
PLEASE REFER NIT DOCUMENT
RATE CONTRACT FOR REPAIRING REPLACEMENT OF AIR CONDITIONER UNITS AND OTHER ELECTRICAL ITEMS AT VARIOUS SITES IN BA JAMMU 2025 26
2025_BSNL_233859_1
04/CPPP/EE(EP)/SE (E)/BSNL/JMU/2025-26
Open Tender
Electrical Works
Item Rate
30 days
JAMMU
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Yes
AO CASH O/O CGM BSNL JAMMU
₹78,570
Yes
30 May 2025
28 Apr 2025
30 May 2025
28 Apr 2025
26 May 2025
28 Apr 2025
Amount
Replacement / supplying & laying of 2 x 1.5 Sq mm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
Replacement / supplying & laying of 3 x 1.5 Sq mm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
Replacement / supplying & laying of 3 x 2.5 Sqmm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
Replacement / supplying & laying of 3 x 4 Sq mm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
Replacement of faulty 2X 40 W / 1 x 40 W / box type flourescent fitting with supplying & fixing of 4' long 18/20 Watt LED fitting as light source, suitable for operation on 220 volt single phase ac supply complete connections etc. complete as reqd.( M/s Crompton / Havells of similar superior make )
Replacement of faulty lamp including dismantling faulty and supplying & fixing new 9/10 Watt LED lamp in the existing fitting etc complete T &C as required
Replacement of faulty lamp including dismantling faulty and supplying & fixing new 20 Watt LED lamp in the existing fitting etc complete T &C as required
Rewinding of Wall Fans / Ceiling Fans of all size complete with removing from site, shifting to workshop for repairs, strip opening /dismantling for repairs, winding with suitable size good quality copper wire, replacement of faulty bearing/ bushes etc. as required, varnishing, drying, refixing of repaired fan at site etc. complete as reqd.
Rewinding of Exhaust Fans of 12" size complete with dismantling, winding with suitable size copper wire, varnishing, drying, refixing etc complete as reqd.
Rewinding of Exhaust Fans of 18" size complete with dismantling, winding with suitable size copper wire, varnishing, drying, refixing etc complete as reqd.
Replacement / Supplying and fixing 25 Watt LED Street Light Energy saving dust and water proof LED fitting with inbuilt controller suitable for operation on 220 V to 240 Volt etc. on existing duly fixed on the existing GI bracket with nuts & bolts etc reqd.( M/s Havells, Philips, CG, Bajaj, Wipro or SS make)
Replacement / supplying & laying of faulty / burnt LT cable of 1.1 KV grade with 4 x 16 sq mm XPLE insulated aluminum conductor steel armored cable of 1.1 KV grade including laying on surface/ wall etc. complete as required. (Note-Unserviceable / damaged cable shall be property of the agency, Rates shall be quoted accordingly)
Replacement of faulty fan condenser with new one complete as required
Replacement of faulty Step type fan regulator with new one complete as required
Supplying and fixing brass batten/ angle holder including connection etc as required
Supplying and fixing 12- way , Double door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, Single pole, 240 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, Single Pole & Neutral, 240 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, TP&N, 415 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP MCB sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 20 mm size medium class PVC conduit a/w accessories on surface / recess i/c cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25 mm size medium class PVC conduit a/w accessories on surface / recess i/c cutting the wall and making good the same in case of recessed conduit as required.
Supplying & drawing of 1-run of cable of UTP 4-pair CAT-6 LAN cable in the existing surface/recessed steel/PVC conduit as required.
Supplying & drawing of 2-run of cable of UTP 4-pair CAT-6 LAN cable in the existing surface/recessed steel/PVC conduit as required.
Supplying & drawing following 3X1.5 sqmm FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required.
Supplying and fixing of 5/6 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required
Supplying and fixing of 3 pin 5/6 A modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required
Supplying and fixing of 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required
Supplying and fixing of 6 pin 15/16 A modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing 16"(400mm) sweep 5-star rating wall mounted oscillating type fan having 3 speed regulator i/c all accessories suitable for 230 volt AC single phase supply i/c connections etc complete as required ( M/s Havells make or similar superior model of Crompton/Usha/Ortem/ Khaitan make).
Supplying and fixing call bell / buzzer suitable for single phase 230 V complete as required
SITC of 600mm x 600mm size surface type prewired 36 W LED Fitting complete with all accessories etc. Directly on ceiling complete with all accessories etc. i/c connections with 1.5 sq.mm. FRLS PVC insulated copper conductor, single core cable and earthing etc. as reqd. (Crompton POLARIS NIO III or similar model of superior make)
Supplying and fixing of 6 Module (200mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required
Supplying and fixing of 8 Module (125mmX125mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required
Carrying out Wet Servicing of 1.5TR / 2TR Window / Split AC unit i/c removing, cleaning all components and filters, de-dusting by high pressure air blower, washing condenser, evaporator i/c chemical cleaning (if required), refixing, tightening electrical connections, minor repairs, if required, testing of AC unit, recording all parameters in service report etc as reqd.
Repairing & Testing of 1.5/2.0 TR Capacity Split AC Units, flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vacumising, removal of leakage in Indoor unit & out door unit including supply & charging of refrigerant gas (R-22) and oiling, greasing of motors, testing commissioning etc. complete as reqd.
Replacement of faulty /defective 1.5 TR capacity compressor with new Sealed compressor i/c dismantling of faulty compressor, cutting refrigerant piping, brazing & making necessary addition/alteration i/c proper mounting on base plate, connection of suction and discharge lines, Leak test , supplying & charging required qty. refrigerant gas i/c testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) (Note - The firm shall submit test certificate or documentary proof towards purchase of New/OEM factory repaired compressor.) The material under replacement shall be similar to existing defective material or as per product directory)
Replacement of faulty /defective 2.0 TR capacity compressor with new Sealed compressor i/c dismantling of faulty compressor, cutting refrigerant piping, brazing & making necessary addition/alteration i/c proper mounting on base plate, connection of suction and discharge lines, Leak test , supplying & charging required qty. refrigerant gas i/c testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) (Note - The firm shall submit test certificate or documentary proof towards purchase of New/OEM factory repaired compressor.) The defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory)
Replacement of faulty damaged Condenser Fan Motor for Split AC unit in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged Indoor Fan Motor for Split AC unit in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged Blower in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged PCB assembly main in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged Fan blade in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged PCB Control card of 1.5 TR inverter type AC unit for I/D unit in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged PCB Control card of 1.5 TR inverter type AC unit for O/D unit in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of existing faulty / unserviceable1.5 TR indoor unit of Split type Air conditioner unit including removing the faulty and supplying new indoor unit suitable for operation on 230 A supply complete with blower, cooling col, filter, controls ad all accessories and remote control etc. fixing the new one, connection of copper pipes, soldering / welding etc. testing and commissioning as required.
Replacement of faulty damaged Copper piping for Hot & cold lines in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required. (NOTE- The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of choked / faulty 20 mm dia PVC flexible drain pipe in recess or on surface for drainage of split AC units i/c connections etc complete as reqd.
Replacement of faulty starting capacitor along with relay with new one for split/ window type AC unit complete as required
Replacement of faulty running capacitor with new one for split / window type AC unit complete as required
Replacement /supplying and fixing of fire extinguishers of 4.5 Kg CO2 type complete with delivery hose horn, squeeze grip/ wheel type release valve, locking arrangement, operating manual and hanging arrangement complete with installation at site complete as required (ISI)
Replacement /supplying and fixing of fire extinguishers of CO2 trolley mounted type Fire Extinguisher ISI marked conforming to IS: 2878. Capacity 9 Kg. Complete with delivery hose horn, trolley, handle wheel type release valve, locking arrangement.
Refilling of fire extinguishers of CO2 type 4.5 Kg type with CO2 Gas complete shifting from site to workshop, refilling and reinstallation at site alongwith providing minor repairs/ replacement of hose pipe, painting with Fire red colour paint etc. complete as required.
Rewinding of 1 HP motor complete using suitable gauge copper wire as required
Replacement of faulty heating element of Geyser of all sizes complete as required
Replacement of faulty thermostat of Geyser of all sizes complete as required
Dismantling of the existing 15-30 KVA rating LT Panel complete with disconnection of cable connections, earth connections etc. and loading into the vehicle, transportation to new location ( Distance upto 40 KM) as per requirement complete with unloading at destination on foundation/ floor, including manual dragging complete with Installation , testing commissioning , cable connections, earth connections etc. as per site requirement.
Dismantling of the existing 15/20 KVA DG complete with disconnection of cable connections, earth connections, loading into the Load carrier, transportation with all accessories to new location (Distance of cartage upto 40 KM) as per requirement complete with unloading at destination site on foundation, including manual dragging complete with Installation, testing commissioning, cable connections, earth connections etc. as per site requirement.
Dismantling of the existing 30-50 KVA DG complete with disconnection of cable connections, earth connections, loading into the Load carrier, transportation with all accessories to new location (Distance of cartage upto 50 KM) as per requirement complete with unloading at destination site on foundation, including manual dragging complete with Installation, testing commissioning, cable connections, earth connections etc. as per site requirement.
Dismantling of the existing 15-30 KVA Servo motor operated ONAN cooled Automatic Voltage Regulator complete with all accessories, oil etc. disconnection of cable connections, earth connections, loading into the Load carrier, transportation to new location (Distance of cartage upto 50 KM) as per requirement complete with unloading at destination site on foundation/ room, including manual dragging complete with Installation , testing commissioning , cable connections, earth connections etc. as per site requirement.
Dismantling of the existing 31-50 KVA Servo motor operated ONAN cooled Automatic Voltage Regulator complete with all accessories, oil etc. disconnection of cable connections, earth connections, loading into the Load carrier, transportation to new location (Distance of cartage upto 50 KM) as per requirement complete with unloading at destination site on foundation/ room, including manual dragging complete with Installation , testing commissioning , cable connections, earth connections etc. as per site requirement.
Supplying and errection of 11 KV Disc insulator for 11 KV overhead lines complete with G.I. fittings, ball & sockets type and complete with Galvanised strain clamps, bolts, nuts washers etc as required.
Supplying and errection of 11 KV Pin insulator for overhead lines complete with G.I. pin, nuts, washers etc as required
Supplying of 7.77 mm. dia. ACSR conductor (Weasel -- 6/1 x 2.59) having tensile strength of 1136 Kgs. and approx. weight of 128 Kg / Km complete as required.
Providing & fixing of 100mm x 50mm PVC Trunking with top cover for laying of cables/ Electrical wiring complete as required at site ( ISI )
Dismantling /shifting/installation of the existing 1.5 / 2 TR AC unit complete with disconnection of hot & cold gas pipes, cable connections and shifting to desired location within building complex including installation of indoor & out door units, testing and commissioning at destination location complete with laying of piping, cables etc. Complete as per site requirement.
AKHTAR ELECTRICALS (BID ID -846802)
VEE GEE ENGINEERS (BID ID -853496)
Jaima Electricals (BID ID -854056)
FAIRDEAL ENTERPRISES (BID ID -846356)
M/S SHANDAR ENTERPRISES (BID ID -852940)
FAVOURITE ELECTRICALS (BID ID -849222)
M.O.S ELECTRICALS (BID ID -852775)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .