Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC 387 DARIA U T CHANDIGARH 160101 | CHANDIGARH | CHANDIGARH | 160101 | ₹7.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.8 LRejected-Finance CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹7.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹7.9 LRejected-Finance 109 MALOYA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹7.9 L | L3 | Rejected-Finance L3 |
| 4 | L4₹8.3 LRejected-Finance BLOCK B SECTOR 26 CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹8.3 L | L4 | Rejected-Finance L4 |
| 5 | L5₹8.3 LRejected-Finance | ₹8.3 L | L5 | Rejected-Finance L5 |
Tender Value
₹12.2 L
EMD Value
₹24,500
Closing Date
9 Feb 2026, 12:00 pmClosed
Er. Chander Shekhar
Office of the Executive Engineer, Electrical Division No. 3 Sector-4, Chandigarh.
Renovation of EI 6 nos. type V new house no.1010, 1010/1, 1010/2, 1011, 1011/1, 1011/2 Doctor accommodation sector-39, Chandigarh.
2026_CHD_90402_1
E3/47W/205
Open Tender
Electrical Works
60 days
Chandigarh
as per NIT
2 documents required · 2 mandatory
₹0
₹24,500
12 Mar 2026
3 Feb 2026
9 Feb 2026
3 Feb 2026
9 Feb 2026
3 Feb 2026
DSR Item No.1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor\ single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group-B
DSR 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group-B
DSR 1.16 Rewiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
DSR Item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
2 way 5/6 A switch
Bell push
3 pin 5/6 amp. socket outlet
DSR Item No.1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
DSR 1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module
4 Module
6 Module
8 module
12 module
DSR item no. 1.33Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
DSR item no. 1.38Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
DSR 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
DSR 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
DSR 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
DSR 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
4 way (4 + 12), Double door
DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole and neutral
DSR 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
DSR 2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR 1.14 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
DSR 5.1 Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
DSR 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
DSR 9.2 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supply and Erection of B.L. Holder of ISI marked on the existing junction box/ wooden block including making the connection etc. as required. The job includes the all labour and petty material charges required to complete the job to the entire satisfaction of E.I.C. of work.
Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole in existing wall suitable size of above fan making in original shape of wall. The size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC.
Size 12 inches (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells make (Turbo Force SP)/ Crompton make ( EXHD300-6-1)/ Bajaj make (Supreme Plus)/ Orient make (Industrial Heavy Duty)/ Usha Make (Turbo HDEF) make only.
S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA/ PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen at 100 lm/ watt (minimum) and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The fitting should be of Philips/ Bajaj/ Wipro/ Havells/ Jaquar/ Crompton/ Panasonic/ Surya/ Lauritz Knudsen/ Trilux make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD<15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge.
S/E of fresh air fan high speed motor with copper would 10” sweep with louver and plastic body complete with speed motor, blades, epoxy powder coated of Havells make Ventilator Ventil Air-ZX/ Orient make ventilator/ Crompton make Brisk Air Neo/ Usha Crisp air/ Bajaj Supreme maxima DXI only. The cost includes the connection with adjacent light points and installed on wall with suitable arrangement by providing frame of required size made out 6mm thick water proof plywood to be installed with suitable size rag bolts, nuts after making suitable size hole in the wall if required at site to the entire satisfaction of Engineer-in-charge.
DSR 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
100 A,30KA,FPMCCB
S/E of sheet metal 3 phase bus-bur chamber on existing surface with required no. of bus-bar strips of suitable 1.6 mm thick with detachable cover fitted with dust excluding gasket and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with GI bolts and nuts/rag bolts and nuts etc. complete with all accessories including connections with suitable size tin coated copper thimbles, bonding to the existing earth & painting etc as desired by the EIC.
Sheet metal bus-bar chamber 100 amp 415 V capacity with 4 copper strip 3 feet long
DSR 8.10 LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness >0.50 mm) 18- 22 Watt
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 27.55 MB
BOQ_110561.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid