ARC for Replacement of Submersible Pump Set and accessories and Deepening of existing 150 or 200 mm dia Tube well at Urban and Rural Water Supply Schemes of PHED Division Khetri District Jhunjhunu
2026_PHCJA_557729_1
NIB07/2026-27
Open Tender
Civil Works - Water Works
Percentage
365 days
KHETRI
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
EXEN PHED DIVISION
₹1.5 L
Yes
15 May 2026
9 May 2026
19 May 2026
9 May 2026
18 May 2026
9 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
15 KW (20 HP) and above, head above 120 mtr. | - | - | - | - |
| 2 | Up to 5.5 Kw (7.5 HP) and Head above 120 Mtr. | 1 | Kw | 8,159.32 | ₹8,159.32 |
| 3 | 7.5 KW (10 H.P.) & head above 120 Mtr. | 1 | Kw | 7,050.85 | ₹7,050.85 |
| 4 | 9.3 KW (12.5 H.P.) & head above 120 Mtr. | 1 | Kw | 6,400 | ₹6,400 |
| 5 | 11 KW(15.0 HP) & head above 120 Mtr. | - | Kw | 5,573.73 | - |
| 6 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18 and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC | - | - | - | - |
| 7 | Above 5 HP and upto 10 HP | 1 | Each | 20,570.34 | ₹20,570.34 |
| 8 | Above 10 HP and upto 15 HP | 1 | Each | 23,583.9 | ₹23,583.9 |
| 9 | Above 15 HP and upto 20 HP | 1 | Each | 27,217.8 | ₹27,217.8 |
| 10 | Providing & Lowering in tube well ISI marked GI Pipe medium duty ( B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. | - | - | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.24 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
Tendernotice_2.pdf
PDF • 3.24 MB
BOQ_992903.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .