Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
7 Oct 2023, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
SPECIAL REPAIR TO BLDG NO. E-23, E-28 AND 28 AT ARTY CENTRE UNDER AGE B/R-I OF GE GOLCONDA
2023_MES_618616_1
8723/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
As Per Tender
8 documents required · 8 mandatory
₹500
GE GOLCONDA
₹97,000
Yes
9 Oct 2023
13 Sept 2023
9 Oct 2023
13 Sept 2023
7 Oct 2023
27 Sept 2023
Amount
Dismantling of AC sheets / Galvolume sheet / GI Sheet of corrugated or semi-corrugated sheets in roof coverings etc complete all as directed.
Dismantling of boarding, any description fixed in any position with nails complete all as specified and as directed
M & L pre-painted galvalume aluminium zinc coating GI based corrugated mangalore profile sheet 0.50 mm thick having tensile strength 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed
M&L pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick, having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
S & F for MS framed structure roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc complete all as specified and as directed
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and as directed
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed
M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to anin half brick thick walls built in cement mortar 1: 4 complete all as specified and as directed
Taking down cement plaster of any description and in any position of brick/concrete surfaces on walls / celing etc. including racking out joints, hacking for key, scrubbing down with water etc & prepared to receive new plaster and disposing off the rubbish off the premises of cantonment complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces, applied in two layers i.e. Ist layer of 10 mm thick rendering in CM 1:6 and 2nd ( top ) layer of 5 mm thick rendering in CM 1:4( top layer mixed with water proofing compound as per manufacturer's instructions) finished even and smooth without using extra cement complete all as specified and directed. (Note: Water Proofing Compound shall be measured and paid separately under relavent item of this schedule )
Supply only integral water proofing compound
M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed
M&L for preperation of newly plastered surfaces of wall and applying 1.5mm thick wall care putty and two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed
M&L for preparing newly plastered surfaces of wall and applying Two coats of cement based paint over a coat of alkali resistant primer complete all as specified and directed
M&L for complete removal of existing treatment on old surface of walls and applying 1.5mm thick wall care putty and two coats of oil bound distemper over a coat of alkali resistant priming paint complete all as specified and directed
M&L for complete removal of existing treatment on old surface of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed
Dismantling Stone slabs and tiles of any description or thickness in floors, plinth Protection, aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 CM thickness ( below or above ground level complete all as specified and as directed.
M&L for Pre-polished Machine cut kota stone slab flooring 20 -25mm thick laid over and including 20mm thick cement screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Pre-polished Machine cut kota stone slab 20 -25mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick cement backing coat in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L 75mm thick plain cement concrete (1:4:8), Type D2 (using 40mm graded stone aggregate) as in sub base of floors laid in alternative bays including necessary form work complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4 Type B1 (using 12.5 mm graded stone aggregate) below tiles for levelling of existing surface complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets and S & F true or horizontal level 600mmx600mm panels, false ceiling, hot dipped galavnised steel sections exposed suface with precoated capping, main tee of size 24x32mm at every 1200mm c/c and cross tee of size 24x27mm (1200mm & 600mm long) at every 600mm c/c and wall angle of size 19x19mm fixed to perimetere wall, as per manufacturer's instructions, grid to be suspended at every 1200mm c/c in both directions by using 3mm dia pre-straightened GI wire at every 1200mm internal at the main tee, including 9mm thick gypsum board of size 600mm X 600mm with rear size aluminium foil and front side PVC lamination, complete all as specified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and as directed.
M&L for non skid coloured ceramic floor tiles 7-8 mm thick (square/ rectanglar) area of each tile exc 0.11 sqm but n. exc 0.18 sqm , set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including screed bed or bedding layer 15 mm thick CM 1:6 for laying floor finishes complete all as specified and directed.
S&F for glazed ceramic coloured tiles of size 350x250x7mm/450x350x7 mm thick for vertical surfaces as in dado/skirtings set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM 1:4 of fair faces of brick work or concrete surface complete all as specified and directed
Taking down carefully existing point wiring of any description for (light, fan ,sockets bells etc) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets ,fittings, pendants, fan regulartors etc and making good the disturbed surface of walls, floors etc. all as specified and directed.
Taking down existing sub main wiring /Service wire of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc.
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including PVC rigid conduit with all fittings for concealed type on stone / brick, masonary walls, roof etc including new CI/MS sunken box of required size and all as directed by Engineer-in-Charge & 3 mm thick plastic laminated sheet for housing switches sockets, regulators etc. including cutting/running chases, pinning in and making good the disturbed surfaces to match with the existing specification, complete all as specified and directed.
All as per item No.32 but One 5 pin 5/6 Amps switch socket outlet on independent board complete all as specified and directed
All as per item No.32 but One 5 pin 5/6 Amps switch socket outlet on same board complete all as specified and directed
All as per item No.32 but for One 5 pin 15 / 16 Amps switch socket outlet point on independent board with 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed
S&F switch piano flush type single pole one way 5/6 Amps complete all as specified and directed
S&F switch socket combination flush type 5 Amps Multipurpose 2 in 1, 3 pin/5 pin with porcelain base complete all as specified and directed
S&F for switch piano flush type single pole one way 15/16 Amps complete all as specified and directed
S&F Switch socket combination 2 in 1 flush type universal 3 pin 5 & 15 Amps complete all as specified and directed
S&F lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed
S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminals complete all as specified and directed
S&F Fan Regulator (Rotary step type, Switch/Socket type Dimmer) 230/240V, AC complete all as specified and directed.
S&F in repair 9 W LED bulb of base B22d with color temp 6500K complete all as specified and directed.
Supply and fixing LED street light fitting 35/36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F Wall mounted indoor decorative 20W LED 6000K (4 ft.), polycarbonate body with minimum 100 lumens/watt. THD less than or equal to 20 with inbuilt surge protection up to 2.5KV and integrated electronic driver, lamp color white, temp 6500K complete set including necessary connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
Fixing only LED lights fittings of any type and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F LED light fittings, 1x10 watts bulk head luminaires etc complete with all accessories and including connecting up with twin core twisted flexible PVC copper conduct cabe of 23/0.0076 from ceiling rose complete all as specified and directed.
S&F Sheet metal enclosure MCB distribution board including 100 Amps bus-bar single pole and neutral 240V, 8 Ways, double door including taking down of existing sheet metal enclosure complete all as specified and directed.
All as per item No.48 above but TPN 4 way, 415 V complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 6-32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP of current carrying capacity 40 to 100 AMP in the DB complete with connection testing and commissioning complete all as specified and directed.
Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 4.00 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in and including PVC conduit medium grade with all fittings suitable for concealed type and making good the disturbed wall surfaces to match with existing specification all as required at site complete with all as specified and directed.
S&F in repair bracket suitable for fixing of building security light fitting made out from 40 mm bore GI pipe, medium grade 2 metre in length, made to shape as required, fixed to pole with MS flat iron clamp of size 25x4mm duly welded, bent to shape and making holes etc complete including necessary nuts, bolts & washer etc as required and complete all as specified and directed.
Taking down Ceiling fan, sealing cable end, dismantling blades and removing fan and blades and refixing ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
M&L fabricated of iron bands,straps,supports or stays for rain water ,ventilating pipes including bolts if required hooks(stay) heavy for large gates ,hook and pintle hinges,large hasps and staples ,chains,hand made slidings bolts clamps hold fasts,wall ties hook for hanging fans,plain angles cleats for securing purlins to wood trusses or rafters ,knee piece inserts two way and three way straps plate washers and similar small articles conforming to Fe 290 Gde E-165, including clamps nuts,bold,fixing and old one complete all as specified and directed at site.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq mm X 3.5Core complete all as specified and directed.
All as per Item No. 58 above but 25 Sqmm X 3.5 Core
All as per Item No. 58 above but 10 Sqmm X 4 Core
M & L for cutting of hard standing made of concrete ,soiling and morrum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 Mtr wide and not exceding 1.5 Mtr in depth and getting out for taking out / laying of cables, erection of poles / strut / stays etc and not exceeding 10 sqm on plan complete all as specified and directed.
Returning, filling in the any type of soil including spreading, levelling, watering and ramming in layers not exc. 25 cms complete all as specified and directed.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread approved M-Sand / Robo Sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed.
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 115 x 75mm for cable protection complete all as specified and directed.
Supplying, installing, commissioning and testing in repairs factory made LT Kiosk box with canopy of size 1000x600x450mm with 4 Nos 100 Amps aluminium bus bar and 4 Nos aluminium lugs of size 40x5mm of length 75mm made out of 3.15mm thick CRCA sheet duly powder coated and locking arrangement duly tested/approved by CPRI including grouting in PCC (1:3:6), type C-1 complete all as specified and as directed.
M&L Earthing complete with galvanized steel with eartg plate electrode 600 X 600 X 6mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32x6mm as earthing lead connected by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point including necessary earth work and excavation, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia light grade all as specified and directed.
M/s Bhavani Constructions
M/s Amit Associates
RAM CHARAN CONSTRUCTIONS
BSA INFRA
Sri Associates
DWARKA PERSHAD RADHEY RAMANLAL
Sri Lakshmi Enterprises
RAHUL CONSTRUCTION
M/S Veerabhadra Constructions
NAVANAND ENTERPRISES
m/s s indra reddy constructions
STANDARD AGENCIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .