Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC AT KHARJARBARI DIST GIRIDIH | GIRIDIH | GIRIDIH | JHARKHAND | L1 | Accepted-AOC As per lowest quoted rate than L2 bidder | |
| 2 | L2₹4.8 L+₹4,567.78 (0.95%)Rejected-Finance AT P O DAKRA DIST RANCHI | DAKRA | RANCHI | JHARKHAND | 829210 | L2 | Rejected-Finance As per Highest Quoted rate Than L1 bidder | |
| 3 | L3₹5.8 L+₹97,379.50 (20.3%)Rejected-Finance BACHRA RAY KHALARI RANCHI JHARKHAND 829210 | RAY | RANCHI | JHARKHAND | 829210 | L3 | Rejected-Finance As per Highest Quoted rate Than L1 bidder |
Tender Value
₹4.6 L
EMD Value
₹5,750
Closing Date
29 Oct 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM Rajhara Area
CCL GM Office Rajhara Area
Extension of 3.3KV OHL about 800m length for dewatering of mines at Rajhara OCP under Rajhara Area
2022_CCL_259298_1
GM(RA)/CHANDWA/EnM/22-23/21 DATED 10.10.2022
Open Tender
Electrical and Maintenance Works
Item Rate
21 days
Rajhara ocp Rajhara Area Chandwa
As per NIT
2 documents required · 2 mandatory
₹5,750
8 Dec 2023
14 Oct 2022
31 Oct 2022
15 Oct 2022
29 Oct 2022
15 Oct 2022
15 Oct 2022 - 22 Oct 2022
Amount
Erection of metallic pole of above 10 mtr. and upto 12 mtr length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Dismantling of pole / street light standard / strut embedded in cement concrete foundation etc. as required
Supplying of 50 mm X 8 mm M.S. flat iron pole top bracket/ cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of pole top / straight two wire / v shape two wire , angle iron / channel iron , cross arm on steel tubuler / rail / PCC pole of 11 / 22 / 33 KV as required
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Erection of ACSR conductor of 7/2.11mm to 7/3.00 mm dia and including binding etc. as required
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
8 SWG GI wire
Erection of GI wire no. 8 SWG including binding etc. as required
Erection of hexagonal type guard as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with aluminium paint of approved brand and manufacture over a priming coat of ready mixed zinc chromate yellow primer on new work : 125 mm diameter pipes/pole, channels, angles etc.: 24 no. x 10m avg height ( marking with red paint and numbering ) board making 2m x 3m x2 no.
Supplying of 800A, 11KV grade Horizontal type GOAB Switch
Total impact of GST for the purpose of CTC
M/s DILIP ELECTRICAL WORKS
SHREE RAM ELECTRICALS
stage.html
html • 0.04 MB
techsummary_268132.pdf
PDF • 1.93 MB
finsummary_268132.pdf
PDF • 1.93 MB
LOA222321.PDF
PDF • 4.16 MB
finance_268132.pdf
PDF • 0.17 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .