Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 441 190 A SIDDIQUI HOUSE MALAPURAM COLONY JAL NIGAM ROAD BALAGANJ LUCKNOW UTTAR PRADESH 226003 | LUCKNOW | UTTAR PRADESH | 226003 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
28 Mar 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer (EWCL)
Type-IV/3, Transmission Staff Colony Dewa Road, Chinhat Lucknow
Increasing capacity of 33/11 KV S/S Sandi 1x10 Plus 1x5 to 2x10 MVA under EDD-I, Hardoi under the Nagar Nikay
2023_MVVNL_781284_1
33/EWCL/2022-23
Open Tender
Electrical Works
Fixed-rate
90 days
33/11 KV S/S Sandi under EDD-I
As per tender documents
2 documents required · 2 mandatory
₹1,180
A/c No. 0758002100009592, IFSC PUNB0586800
₹10,000
1 Apr 2023
4 Mar 2023
28 Mar 2023
4 Mar 2023
28 Mar 2023
4 Mar 2023
Amount
Safe loading, carriage and unloading & proper stacking of following store materials from any Electy. Store of Lucknow Zone to 33/11 KV S/S Sandi, Hardoi site (work site).
Cost of 33 KV Bus Isolator
Cost of Post Insulator
Cost of 33 KV Lightening Arrester
Cost of 33 KV VCB 800 Amp., 750 MVA
11 KV 3x300 Sq.mm XLPE Cable
MS Angles 50x50x6mm for bracing type members of T.G./B.G./Trench
MS Angles 75x75x6mm (6.8 Kg/Mtr.) for Neutral/Cable Stand
Cost of ACSR Panther Conductor
MS Channel 100x50 mm (9.6 Kg/Mtr.) for Cable Stand
11 KV 3x300 SQ MM XLPE Cable Outdoor
11 KV 3x300 SQ MM XLPE Cable Indoor
Single Core PVC Cable, 1x400 sq.mm.
Dismantling & safe shifting of existing & working 33/11 KV 05 MVA T/F from plinth to suitable storage place after opening jumper and cable connections as per instruction of Site Engineer.
Extension and Repairing of Power Transformer Plinth for 10 MVA T/F.
Earthing for power T/F by way of boaring and lowering of 40mm dia, 2.5 mm thick GI Pipe from ground upto the water level (minimum 30 Mtr. deep) as per standard practice as per REC Drg. No.-41
Earthing of 11 KV, 33 KV Switchgears & Equipment: Earthing of 11 KV, 33 KV Switchgears equpiment by lowaring and boring of Chemical Earting outsite of switchyard and connecting through G.I. Strip 50x6mm with indoor/outdoor equipments. (All the matrial provided by the contrartor)
Fabrication and grouting (1:4:8) of MS Angle 75x75x6 mm in L Shape & in proper size and alignment to provide support for the two separate earthing strips (50x6)mm size for power transformer neutral including supply & fixing of two no. flexible copper bonds for neutral earthing as per Drg. No.-41.
Fabrication and erection of cable support made of two pieces of MS channel 100x50mm, 3.0 mtr. long joined to each other by means of 5 no. MS Fat 50x6mm pieces of size 150mm long each by welding at equal intervals as per drawing and grouting in block of size 300x300x700mm (1:4:8) complete with one coat of ready mixed primer and two coats of Al. Paint. This includes providing of four no. MS Clamp made of MS Flat holding the cable including nuts & bolts and fixing of XLPE cable.
Plinth of VCB : Construction of Plinth of size 2.0 mtrx1.5mtrx0.9mtr. suitable for erection of upper structure of 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC 1:3:6 (cement, find sand & brick ballast) 1st class brick work in cement mortor ratio 1:4:8 (cement, coarse sand and stone grit of 20mm gauge).
Installation of Isolators: Dismantling and replacment of old amd damged existing 33 KV Isolators by new 33 KV bus isolator and assembling and installation of line/ bus isolator on the isolator structure adjusting of opening mechanis in proper alignment so as to ensure smooth operation of the same. In case of line isolator proper operation of earth links shall also be ensured. The work includes fabrication & proper connection with earthmat/earthing by G.I. earth strip 50x6mm proper fixing if required (All decentralised materials to be provided by Contractor).
Installation of VCB: Installation of 33KV VCB complete work with making earth connections(Earth Mat/earthing) with GI Strip 50x6mm including control wiring, commissioning & testing (All decentralised materials to be provided by Contractor).
Installation of Lightening Arrestors : Assembling, installation & mounting of 3 No.(1set) L.A. on the L.A Structure/complete with making earth connections(separate) and line connections. The work includes fabrication for fixing if required.
Installation of P.I. : Assembling, installation & mounting of Post insulator on the P.I. Structure/complete with making earth connections (separate) with GI Strip 50x6mm. The work includes fabrication for fixing if required. (All decentralised materials to be provided by Contractor).
Fixing and making Bus Bar connections in between all switchgears after cleaning and tapping with H.T. Tape, empire tape and PVC tape properly, providing and fixing of 6 mm thick Bakelite separators and plugging of all opening & holes with plastic compound complete work as per satisfaction of site incharge.
HT Cable Laying : Laying & dressing of 11KV 3x300 Sq.mm XLPE cable (Single circuit) from 10MVA T/F to 11KV incoming Switchgear by excavation of earth in the trench 450 mm wide, 900mm deep providing 150mm fine sand cushion below and above the cable. The cable shall be duly protected by bricks, sand & stone slab. The work includes supplying of fine sand, bricks and stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable.
Hoisting of 11KV Cable to 11 KV switchgear & 33/11KV T/F.
Supply and laying of following size Copper Control Cable through underground/cable trench/trenching SGR interlinking through proper connections to T/F Control panel/protection board/Battery and Battery Charger/Bunch joints, Relay 33/11KV T/F junction Box/33KV VCB, CTs etc. as per site conditions:
4x2.5 Sq.mm
6x2.5 Sq.mm
Control Cable Trey
Painting of all structures and equipments.
Fixing of Single Core PVC Cable, 1x400 sq.mm. & fixing between Transformer incoming 3x300 Sq.mm XLPE Cable and Transformer 11 KV/LV Side Bushing connector for reducing of tension at LV Side Bushing.
Construction of Cable trench of size 300x300mm including brick work 1:4 in wall of the trench, brick ballast work in 1:5:10 on foundation plaster 12mm thick with coarse sand 1:4 and surface finishing with cement, providing MS Strip at an interval of 0.5 Mt. and MS Angle (25x25x5mm) running on both the edges of trench.
Construction of welded frame type control cable trench cover 0.5 Mt. long suitable for trench including cost of MS/Tor Bar.
M/S RUDRACH POWER COMPANY
SINLESS ELECRICAL CO. PVT. LTD.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .