| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC 0 PRAGATIPUR DHARMA SARMA PATH BIRUBARI KAMRUP ASSAM 781016 | KAMRUP METRO | ASSAM | 781016 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹11.6 L+₹2,095 (0.18%)Rejected-Finance 1ST FLOOR P R COMPLEX AT ROAD GUWAHATI 781 001 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹12.0 L+₹38,504 (3.33%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹12.8 L+₹1.3 L (10.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹12.9 L+₹1.3 L (11.3%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
29 Aug 2020, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015 Tele 0361 - 2840127
Repair/Replacement of MCB DB, MCCB DB, Submain Wiring, replacement of Energy meter and allied Electricals fitting/fixtures at certain areas under GE (AF) Borjhar.
2020_MES_365756_1
8763/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE (AF) Barjhar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹30,000
Yes
15 Oct 2020
31 Jul 2020
31 Aug 2020
31 Jul 2020
29 Aug 2020
17 Aug 2020
Amount
Taking down existing sub main wiring of any type/size complete from wall and making good the disturbed surface complete all as specified and as directed by Engineer-in -charge.
S&F for Sub main wiring two single core PVC insulated unsheathed FRLS multistranded copper conductor cable of size 6.0 Sqmm (Nominal area), 1100 V grade and one run of 6.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed muti stranded copper conductor cable as in earth continuity conductor drwan through in and including PVC Casing-in-Caping of required size (ISI marked) with all accessories on roof/wall/ceiling and making good the disturbed surace with cement sand plaster (1:6) and white washing/distempering to match the existing surface complete . Note:- Two runs of 6.0 Sqmm cable and one run of 6.0 Sqmm earth wire and one run of PVC casing-in-caping shall be measured as one unit length.
All as per Item No 2.00 here in before but sub main wiring with two run multi standard FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of size 4 Sqmm for continuous earthing.
Taking down unserviceable rusted/damaged sheet metal enclosure DBs of any size/type/ways from wall carefully and making good to disturbed surface of wall complete all as directed.
Supply and fixing powder coated sheet metal enclosures MCB DB TPN 4 way double door, made out of CRCA mild steel surface with insulated material like polyster with epoxy surface stove enameled dust and vermin proof 4 way 415 Volt fitted with bus bar, DIN channel, neutral link suitable for incorporation of MCB's and isolator etc complete all as specified and directed by Engr-in-charge.
S & F for Sheet metal enclosure double door (IP-43) for load line DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy surface mounting SPN, 8 way, 240 volt, suitable rated copper bus bars, stove enameled dust and vermin proof suitable for incorporation of MCB’s and isolator etc complete all as specified and as directed by Engineer-in -charge.
S & F for Sheet metal enclosure double door (IP-43) for load line DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy surface mounting SPN, 12 way, 240 volt, suitable rated copper bus bars, stove enameled dust and vermin proof suitable for incorporation of MCB’s and isolator etc complete all as specified and as directed by Engineer-in -charge.
S & F for Sheet metal enclosure double door (IP-43) for load line DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy surface mounting SPN, 16 way, 240 volt, suitable rated copper bus bars, stove enameled dust and vermin proof suitable for incorporation of MCB’s and isolator etc complete all as specified and as directed by Engineer-in -charge.
S&F for MCB, SP, 240V, 6 to 32 Amps breaking cap 10 KA; C-series, 240 Volt as in repair complete all as specified and as directed by Engineer-in-Charge.
All as per item No 9.00 above but MCB SPN 6 to 32Amps, 240 volts.
All as per item No 9.00 above but MCB SPN 40 to 63Amps, 240 volts.
All as per item No 9.00 above but MCB TPN 6 to 32Amps, 415 volts.
Excavating in trenches not exceeding 1.5m wide and not exceeding1.5 mtr in depth for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick each layers complete all as specified and as directed by Engineer-in-Charge.
Removal of surplus spoil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.by Engineer –in-charge.
M&L for fine sand (River sand) spread in trenches for cushioning of cable 8cm thick under the cable and 15cm over the cable and punned down gently to 18 cm for protection complete all as specified and as directed.by Engineer–in-charge. Note :- Compacted thickness shall be measured and paid
M&L for brick protection with sub-class ‘B’ bricks laid dry flat (23cm width) cross the cable for protection to cable after sand cushioning complete all as directed by Engineer-in-Charge.
Taking down old XLPE LT Underground Cable complete all as specified and directed by Engineer-in-Charge. Note:- Earth work will be measured and paid separately under respective items.
Supply and Laying LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 2 core 10 Sqmm aluminium conductor in trenches/poles and connecting with all accessories lugs & glands complete.
All as per item No.19 above but of cable 4 core 16 Sqmm complete.
All as per item No.19 above but of cable 3.5 core 25 Sqmm complete.
S&F MCCB 100 amps, 4 pole,415 Volt fixed type with breaking capacity 16 KA complete all as specified and directed. Make : Havells Cat No. IHLGNF0100 or equivalent make as sepcified in PS
All as per item No.22 Above but 63 Amps complete.
All as per item No.22 Above but 160 Amps complete.
All as per item No.22 Above but 200 Amps complete.
All as per item No.22 Above but 250 Amps complete.
S&F MCCB 160 amps, 4 pole,415 Volt adjustable type with breaking capacity 36 KA complete all as specified and directed. Make : Havells Cat No. IHLCNF0160 or equivalent make as sepcified in PS
All as per item No.27 Above but 250Amps complete.
All as per item No.27 Above but 400 Amps complete.
S&F change over switch 63 amps 4 pole 415 volt front operated inside the panel with cable connection and accessories after taking down the old unserviceable one complete all as specified and directed . Make Havells Cat No. IHCNFE0063 or equivalent make as sepcified in PS
S&F change over switch 100 amps 4 pole 415 volt front operated inside the panel with cable connection and accessories after taking down the old unserviceable one complete all as specified and directed . Make Havells Cat No. IHCNFE0063 or equivalent make as sepcified in PS
Taking down unserviceable service wire of any size any type all as directed.
S&F 1100 volts grade heavy duty cable PVC insulated Stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1metre apart including 4mm suspension wire, one twin core cable flat or circular of 6 Sqmm, complete all as specified and directed .
All as per item No.33 Above but of size 10 Sqmm complete.
All as per item No.33 Above but of size 16 Sqmm complete.
Supply and fixing Energy meter, Single phase, 230V, 50Hz LCD display with sheet metal enclosure complete all as directed.
Earthing complete with Copper earth plate electrode 600×600× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to Copper earth lead of size 25x3mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
M/S PANKAJ SUPPLY SYNDICATE
M/s Beekey Seekey Traders
M.S. Construction
M/s Rawat Enterprises
M/S Kiran Chandra Das
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .