Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 CrAdmitted-Finance | ₹31.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹32.1 CrAdmitted-Finance 286 2 PARAG STATION ROAD BUDHWAR PETH KARAD SATARA | PUNE | MAHARASHTRA | 412206 | ₹32.1 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Reject |
| 4 | Rejected-Technical ASHOK BAG PLOT NO 16 GAJANAN HOUSING SOCIETY 100 GHUTI ROAD DHAMANI CHOWK SANGLI | SANGLI | SANGLI | MAHARASHTRA | - | - | Rejected-Technical Reject |
| 5 | Rejected-Technical | - | - | Rejected-Technical Reject |
| Sl No | Description | Qty | Unit | Shah EPC Services & Projects Private Limited L2 | Madhukamal Construction Pvt. Ltd L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means | 2,109.29 | Cubic Metre | 231 ₹4.9 L | 227 ₹4.8 L |
| 2.00 | Excavation for foundation in hard murum including removing the excavated materials upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. By Mechanical Means (Lift from 1.5 metre to 3.0 metre) | 612.47 | Cubic Metre | 316 ₹1.9 L | 313 ₹1.9 L |
| 3.00 | Excavation for foundation in soft rock and old cement and lime masonry foundations including removing the excavated materials upto a distance of 50 metre beyond the building area and stacking as directed including dewatering, preparing the bed for the foundation and necessary back filling, with available earth, murum, ramming, watering including shoring and strutting excetra complete. By Mechanical Means (Lift from 1.5 metre to 3.0 metre) | 403.36 | Cubic Metre | 591 ₹2.4 L | 584 ₹2.4 L |
| 4.00 | Excavation for foundation in hard rock by chiselling wedging, line drilling excetra including trimming and levelling the bed, removing the excavated materials upto a distance of 50 metres beyond the building area and stacking as directed, dewatering and back filling with available earth / murum, ramming, watering complete. (Lift upto 1.5 metre) By Mechanical Means | 440.84 | Cubic Metre | 1,468 ₹6.5 L | 1,453 ₹6.4 L |
| 5.00 | Dewatering on brake horse power basis by using water pump including diversion of stream, providing coffer dams, earthen bunds, excetra as may be necessary for foundation and other parts of the works and pumping out water during and after excavation as may be required by using 10.0 BHP to 19.0 BHP pump, excetra complete. | 450 | Hour | 253 ₹1.1 L | 245 ₹1.1 L |
| 6.00 | Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete. | 1,389.22 | Cubic Metre | 2,267 ₹31.5 L | 2,223 ₹30.9 L |
| 7.00 | Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete. | 291.1 | Cubic Metre | 135 ₹39,298.50 | 134 ₹39,007.40 |
| 8.00 | Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. | 1,566.95 | Cubic Metre | 1,142 ₹17.9 L | 1,126 ₹17.6 L |
| 9.00 | Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides for excavation at the rate of 5 liters of emulsion concentrates of 1.0 percent of clorophyriphoas per square metre of surface area covering ten years guarantee on bond paper | 642.74 | Square Metre | 121 ₹77,771.54 | 118 ₹75,843.32 |
| 10.00 | Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyriphoas per square metre of surface area covering ten years guarantee on bond paper. | 642.74 | Square Metre | 120 ₹77,128.80 | 119 ₹76,486.06 |
Tender Value
₹30.2 Cr
EMD Value
₹15.1 L
Closing Date
10 Oct 2024, 6:00 pmClosed
Executive Engineer PWD Miraj
Executive Engineer PWD Miraj Opp Prant office Miraj Tal. Miraj Dist. Sangli
PROPOSED CONSTRUCTION OF 100 BEDDED WOMENS AND NEW BORN CHILD HOSPITAL AT -MIRAJ , TAL.-MIRAJ , DIST. SANGLI
2024_PWDRP_1093463_1
E-Tender Notice No. 41 for 2024-25
Open Tender
Civil Works
730 days
TAL.-MIRAJ, DIST. SANGLI
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,540
₹15.1 L
Chief Engineer Public Works Region, Pune (Online)
27 Jan 2025
26 Sept 2024
11 Oct 2024
26 Sept 2024
10 Oct 2024
26 Sept 2024
26 Sept 2024 - 1 Oct 2024
1 Oct 2024
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated materials upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. By Mechanical Means (Lift from 1.5 metre to 3.0 metre)
Excavation for foundation in soft rock and old cement and lime masonry foundations including removing the excavated materials upto a distance of 50 metre beyond the building area and stacking as directed including dewatering, preparing the bed for the foundation and necessary back filling, with available earth, murum, ramming, watering including shoring and strutting excetra complete. By Mechanical Means (Lift from 1.5 metre to 3.0 metre)
Excavation for foundation in hard rock by chiselling wedging, line drilling excetra including trimming and levelling the bed, removing the excavated materials upto a distance of 50 metres beyond the building area and stacking as directed, dewatering and back filling with available earth / murum, ramming, watering complete. (Lift upto 1.5 metre) By Mechanical Means
Dewatering on brake horse power basis by using water pump including diversion of stream, providing coffer dams, earthen bunds, excetra as may be necessary for foundation and other parts of the works and pumping out water during and after excavation as may be required by using 10.0 BHP to 19.0 BHP pump, excetra complete.
Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete.
Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete.
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides for excavation at the rate of 5 liters of emulsion concentrates of 1.0 percent of clorophyriphoas per square metre of surface area covering ten years guarantee on bond paper
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyriphoas per square metre of surface area covering ten years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the backfill in immidiate contact with foundation at the rate of 5 litres of emulsion concentrates of 1.0 percent of clorophyriphoas per square metre of vertical surface area covering ten years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 centimetre to 1.5 centimetre diameter about 30 centimetre to 60 centimetre deep at 15 centimetre center to center as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. (For Ground Floor)
Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for bed blocks, foundation blocks and such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Providing and laying cast in situ / Ready Mix cement concrete in M-15 of trap / granite / quartzite / gneiss metal for coping to plinth or parapet moulded or chamfered as per drawing or as directed including steel centering, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra complete. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 5th Floor) (using ARTIFICIAL SAND).
Providing and laying Cast in situ / Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Providing and laying cast in situ / Ready Mix cement conrete M-30 of trap metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying cast in situ / Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying cast in situ / Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying cast in situ /Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND).
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying cast in situ / Ready Mix Cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing expansion joints in reinforced cement concrete framed structure (at floor level) with premoulded filler 25 milimetre thick and 3 milimetre thick aluminium plate as required, bitumen poured filler and fixing teak wood battens on rear faces, excetra complete as directed. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing expansion joints in reinforced cement concrete framed structure (at terrace level) with premoulded filler 25 milimetre thick and 3 milimetre thick aluminimum plate as required, bitumen poured filler, fixing lead, flashing on upper side and teak wood battens and inner face finishing, excetra complete as directed. (For 5th Floor)
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying Cast in situ / Ready mix cement concrete M-20 of trap / granite / quartzite / gneiss metal for steps including steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Providing first class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in plinth including bailling out water manually, striking joints on unexposed faces and pointing with cement mortar 1:3 on exposed faces and watering, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Providing first class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 including scaffolding, racking joints pointing in cement mortar 1:3 and watering in pillars of rectangular or square shape as shown on the drawing or as directed, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and applying texture plaster with finishing with texture material approved make in 3 milimetre to 4 milimetre thickness on previously finished plastered surface including plaster groove 6 milimetre thickness or tape grooves 35 milimetre to 45 milimetre thickness or as required, in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing patti / band 75 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in cement mortar 1:3 in line and level including neet finishing, scaffolding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Labour charges for providing groove in external plaster having width and spaced at as directed by Engineer in-charge, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10 percent and oil 15 to 20 percent with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with emery paper 180 and wipe clean. Applying wall primer with brush with mineral turpentine 8 to 10 percent and oil 15 to 20 percent with roller. Scrapping emery paper 320 and wipe clean, interior wall finish luster first coat with brush/ rubber/ spray with mineral turpentine 7 to 9 percent and Oil with roller 19 to 21 percent. After 8 hours of activity, applying second coat or wall finish Lustre with mineral turpentine 7 to 9 percent with brush and Oil with roller 19 to 21 percent after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and applying two Coats of high quality acrylic copolymer matt latex low VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approved make. Paint should have good flow levelling property with good colour retention and incan antibacterial property. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC and Odour putty. This surface should be primed with water based low VOC acrylic copolymer based primer sealer that has incan antibacterial property. The work activity should cover all aspects of applying paints from surface preparation, filling to erecting and dismantling of scaffolding, finishing the surface etc as directed by Engineer in charge. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and applying epoxy paint primer with middle coat and top coat to superstructure including scaffolding, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for reinforced cement concrete / cementitious surface for terrace waterproofing on burnt brick coba / reinforced cement concrete, after application of TP-42 primer on perfectly clean surface (free from loose dust and foreign matter) application of first coat of Polydee-LM at the rate of 700 grams per square metre, applying second coat of Polydee-LM at the rate of 700 grams per square metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25 milimetre cement plaster for protection with fibrillated 6 milimetre Plyplast fibre at the rate of 125 grams per square metre to be paid in separate item.) covering seven years gaurantee on court fee stamp paper of Rs. 100/- excetra complete. (For 5th Floor)
Providing and applying top coat exterior paint to terrace of approved make, shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by throughly cleaning of oil, grease, dirt and other material and fine aggregate (natural sand/crushed sand VSI grade finely washed, excetra) preparing as required, excetra complete. (For 5th Floor)
Waterproofing Treatment to new Toilet / bathroom by using Polymeric Cementitious Membrane as approved by Engineer in-charge, followed by 112 milimetre thick brick bat coba covered with 20 milimetre mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl) -1-propene-Butyl -2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in-charge. Provide and lay 112 milimetre average thicknes of brick bat coba in cement mortar 1:5 over 12 milimetre thick centimetre 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50Kilogrambag of cement and finishing with 20 milimetre thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50Kilogrambag of cement,including all lead, lifts and laid to proper slope to drain off water entirely preparing bell (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and Fixing matt finish stainless steel of 302 grade railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter excetra complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying vitrified matt finish tiles having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick stainless steel hand railing in stainless steel 304 grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing Modular false ceiling of 600 milimetre X 600 milimetre center to center and 13 milimetre thick square mineral fiber board to be fixed on frame work of aluminium sections for suspended false ceiling consisting of aluminium T 2” X 1 ½” (50 milimetre X 40 milimetre) weighing 0.39 kilogram per running metre at 60 centimetre center center and fixed with ½” X ½” (15 X 15 milimetre) flanges weighing 0.19 kilogram per running metre suspended on 6 milimetre diameter mild steel rod weighing 0.22 kilogram per running metre, fixed on wall and beams including rounding of the edges with alluinium T of 2” X 1 ½” (50 milimetre X 40 milimetre) weighing 0.39 kilogram per running metre excetra (all aluminium sections shall be anodized) including all labour, material, lifts, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing of Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles With 15 milimetre Exposed Grid. The tiles should have Humidity Resistance (RH) of 95 percent, NRC 0.9 - 1.0, Light Reflectance .85 percent, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 X 600 X 15mm , suitable for Green Building application, with Recycled content of 66 percent GW and 74 percent RW. The tile shall be laid on precoated G.I channel 32 with 15 milimetre wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 milimetre and 600 milimetre Cross Tees with a web height of 32 milimetre and a load carrying capacity of 7 Kgs/M2 with a minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing factory made solid core flush door shutters in double leaves 35 milimetre thick, decorative types, of exterior grade, as per detailed drawings, conforming to Indian Standard : 2202 - 1962 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastenings, stoppers and finishing with french polishing, excetra (excluding door frame). Commercial hard wood shutter. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing in position, double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 milimetre X 44.75 milimetre, 3.18 milimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 milimetre X 44.5 milimetre, 3 milimetre thick top rails 47.62 milimetre X 44.45 milimetre, 3 milimetre thick, vertical style 47.62 milimetre X 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels excetra, Indian Standard Institution mark, heavy duty, Hydraulic floor spring of 150 kilogram capacity, having heavy duty concealed lock, necessary beeding, glazing clips, poly vinyl chloride gaskets, 250 milimetre length tower aluminium bolts, 150 milimetre diameter pad handle, excetra as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipments, excetra complete. (For Ground Floor)
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 milimetre X 9 milimetre X 3 milimetre minimum size, crossings of mild steel flats of size 18 milimetre X 5 milimetre T or E section for runner of minimum 40 milimetre X 6 milimetre size for flange, mild steel flat for top runner of minimum size 40 milimetre X 12 milimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 milimetre, maximum spacing of vertical channels be 100 milimetre enclosed gate position and clear space of 150 milimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting, excetra complete. (Indian Standard : 10521-1983). (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing factory made single leaf 2 hour fire rated door as per Indian Standard : 3614 Part 2 and British Standard 476 Part 20 and 22, tested to UL 10 C and conforming to NFPA 80, tested at NTL / CBRI / Automobile Research Association of India of plain steel finish type with a) Frame of size 143 milimetre X 58 milimetre and thickness of 1.6 milimetre thick skin pass galvanized iron sheet (conforming to Indian Standard : 277) formed to single or double rebate profile. b) Shutter of 46 milimetre thickness and constructed from 1.2 milimetre thick skin pass galvanized iron sheet (conforming to Indian Standard : 277) infill Rockwool / Mineral wool / Honey comb craft paper. c) Vision glass of 5 milimetre thick clear / wired glass circular or rectangular. d) Finish : Primed with zinc phosphate stoving primer and finished with polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron. e) Accessories : Minimum 8 anchor fastener of HILTI make, minimum 3 stainless steel ball bearing butt hinges, Mortise sash lock with lever handle, Mortise dead bolt, Mortise latch, door closer and flush bolts complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing Indian Standards Institute marked double swing flush door shutters conforming to Indian Standard : 2202 (Part I) Non-decorative type, core of block board construction with frame of first class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 milimetre thick including Indian Standards Institute marked stainless steel L-hinges with necessary screws, fittings and fixtures per leaf, stainless steel kick plates on both sides of the door of 300 milimetre height, heavy duty satin finish butt stainless steel Hinges (100 milimetre X 75 milimetre X 3 milimetre in size) 4 Nos., stainless steel finished lever handle with mortise lock 1 No., floor spring 1 No., 100 milimetre X 100 milimetre safety glass at the specified location. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing 30 milimetre thick both side prelaminated solid panel polyvinyl chloride door shutter consisting of frame made out of mild steel tube of 19 gauge thickness and size 19 milimetre X 19 milimetre for styles and 15 milimetre X 15 milimetre for top and bottom rails, mild steel frame shall have a coat of metel primer of approved make and manufacture. Mild steel frame shall be covered with heat mouled polyvinyl chloride "C" channel made from 5 milimetre (+/0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles; and 5 milimetre thick, 95 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/0.25) thick polyvinyl chloride strip of 20 milimetre width is to be stuck on the bottom side of the "C" channel prelaminated paneling of 5 milimetre (+/0.25) thick polyvinyl chloride sheet to be fitted inside the mild steel frame welded / sealed to the styles and rails with 5 milimetre (+/0.25) X 30 milimetre polyvinyl chloride sheet beading on either side and joined together with solvent cement adhesive, excetra 10 milimetre thickness (5 milimetre (+/0.25) X 2 numbers) 20 milimetre wide cross polyvinyl chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 numbers mild steel powder coated butt hinges of size 100 milimetre X 25 milimetre X 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the mild steel tube. Other hardwares should be fixed with 19 milimetre X 6 milimetre size steel screws including fixture fasting. Complete as per direction of Engineer in-charge. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing factory made steel door of single leaf external embossed wood finish type with a) frame of size 100 milimetre X 58 milimetre conforming to Indian Standard : 4351-2003, 1.2 milimetre thick pre-galvanized sheet with mitred and welded cones, frame stretches, hinge reinforcing plates, fixing plates and hardware mounting plates and polyurethane foam infill. b) Shutter of thickness 46 milimetre made of 0.8 milimetre thick slip coated pre-galvanized steel sheet on both sides conforming to ASTM A527 / ASTM A525, British Standard 2989 1994, Indian Standard 277, zinc coating 120 grams per square metre. Lock formed panels with internal stiffeners of 3 milimetre thick made of galvanized sheet, 3 milimetre thick hinge reinforcing hardware mounting plates and lock protection with honeycomb craft paper infill of thickness 150 grams per square metre of load bearing capacity 500 Kg/Sqm. c) Finish : Powder coated surface finished with thermosetting polyurethane paint of Aliphatic grade of thickness 60 micron. d) Accessories : Minimum 8 anchor fastener of HILTI make, minimum 3 stainless steel ball bearing butt hinges of Dorset make, Dorset Mortise lock, stainless steel Tower bolt of 200 milimetre size, eye hole, door stopper, complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing partitions made up of country cut teak wood frame of size 75 milimetre X 50 milimetre at 60 centimetre center to center with 9 milimetre thick commercial ply and 4 milimetre thick veneer on both side with french polish, excetra complete. (For Ground Floor)
For 5th Floor
Providing and fixing factory made door/Window frames of required colour made with wood Polymer composite (WPC) extuded internal ribbed sections conforming to American Society for testing and materials (ASTM) in regard with density, tensile strength, flexural strength, Izod impact, water absorption and screw withdrawal strength with wall thickness of 5milimetre (+/1 milimetre) and with frames having mitred joints at each corner, joined together by two nos. of 10 milimetre X 8 milimetre and 40 milimetre long polyvinyl chloride dovetail keys including hard wood piece support along the full vertical and horizontal length in rebate portion hole for fixing hinges and fixtures and the frames fixed to Walls/columns with 15 milimetre long dash fasteners/holdfasts (dash fasteners/holdfasts to be paid separately), excetra complete as per the direction of Engineer in charge,with prior approval of concerned Superitending Engineer - For Profile size of 125 milimetre X 50 milimetre with 38 milimetre X 12 milimetre rebate (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing of factory made unplasticized polyvinyl chloride Sliding window and door (White Colour) complete, comprising unplasticized polyvinyl chloride multi-chambered frame having in-built unplasticized polyvinyl chloride roller track on top and unplasticized polyvinyl chloride sash with wall thickness of 2.3mm (+-0.2 milimetre), duly reinforced with galvanised iron section 1.5 milimetre, wherever required. unplasticized polyvinyl chloride window and door profile shall be made in India and shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 milimetre Float Annealed glass in the sash, unplasticized polyvinyl chloride glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers and proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. unplasticized polyvinyl chloride Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.- 3 Track with Mesh-2 Glass Sash (Each sash shall be half of width of window) (Big Series) window frame of size 122 milimetre X 54 milimetre and Sash of size 64 milimetre X 47 mm (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing of factory made unplasticized polyvinyl chloride Louver window (White Colour) comprising of unplasticized polyvinyl chloride multi-chambered with wall thickness of 2.3 milimetre (+-0.2 milimetre ), duly reinforced with 1.5 milimetre thick galvanised iron Section. unplasticized polyvinyl chloride window and door profile shall be made in India and shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 milimetre Frosted Annealed glass. Window will be fixed to the wall with 100 milimetre long and 8 milimetre dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. unplasticized polyvinyl chloride Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration,wrapping and rotting under general use. - Louver Window (Big Series) frame of size 67 milimetre X 62 milimetre and Mullion (if required) of size 67 milimetre X 78 milimetre. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections including necessary fixtures and fastening such as 5 milimetre thick clear float glass, excetra complete. - Powder Coated. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing in position powder coated aluminium openable window of any size as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections including necessary fixtures and fastenings with 5 milimetre thick clear float glass, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing 45 centimetre wide mild steel ladder of 40 milimetre X 6 milimetre mild steel flat stringers and steps of 18 milimetre diameter mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre X 30 centimetre X 30 centimetre and painting the ladder with anticorossive paint complete. (For 5th Floor)
Providing, supplying, fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 milimetre thick aluminium composite panel sheet material consisting of 3 milimetre thick FR grade mineral core following NBC part IV fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS : 476 part 6 and 7 class-O sandwitched between two aluminium sheets (each 0.5 milimetre thick of AA 5005/AA3105 grade). The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF / Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and shade on top face and polymer (service) coating of bottom face as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicon sealent, backer rods, excetra Overall weight of the aluminium composite panel shall not be less than 7.5 kg/sqm). (For Ground Floor)
Providing and preparing kitchen otta up to 75 centimetre width, made up from 30 milimetre thick and 75 centimetre high vertical support for Kadappa at one metre center to center of 25 milimetre thick both side polished Kadappa middle shelf and bottom of 20 milimetre thick one side polished Kadappa with facia patti of 20 milimetre X 50 milimetre Kadappa including all material, labour, cutting, fixing with cement mortar and araldite, all material labour cutting fixing with cement mortar and araldite curing polished and cleaning excetra complete. (For 5th Floor)
Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and fixing crimped wire galvanised iron mesh of size 20 milimetre X 20 milimetre, 10 gauge to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its origional position and oil painting, excetra complete. (Excluding cost structural steel) (For 2nd Floor)
Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and laying 18 milimetre thick ADONI BROWN LEATHER FINISH stone for flooring, machine cut in required size, approved shade, color and texture laid using white cement slurry over 20 milimetre (average) thick base of cement mortar 1:4 followed by laying, fixing and jointed with white cement slurry mixed with matching pigment, including rubbing and curing moulding and polishing to edge to give high gloss finish, etc complete. The application rate for tile adhesives shall be as per manufacturer's recommendations. as per detail drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels and as directed by Engineer in charge. Complete. a) Flooring (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates, excetra as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete. (For 5th Floor)
Providing of 120 minutes Fire rated lead lined doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the Indian Standard : 3614 Part 2 and British Standard : 476 part 22 with standard heating conditions as specified in Indian Standard : 3614 Part II 1992 and British Standard : 476 part 20 and 22 1987 to achieve the required integrity, insulation and stability (that is to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with Non Combustible by Nature technology and tested for radiation at NTH in accordance to AERB norms. - Door Frame : Providing and fixing Frames for Lead Lined Fire resistant door shutters first class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 pounds per inch pressure as per Indian Standard : 401 and kiln seasoned to moisture below 15 percent as per Indian Standard : 1141 of section 140 milimetre X 70 milimetre with 45 milimetre thick two layered 3 milimetre Lead Line Sheets with 10 milimetre overlap from either side and spray coated with 2 coats of in-tumescent paint of minimum 200 micron, with 1 row of Brush-Type Astroflame® intumescent strip (imported) of size 10 milimetre X 4 milimetre concealed in the groove of the Frame for fire and hot and cold smoke sealing, excetra complete as per direction of Engineer in Charge. (For Ground Floor)
For First Floor
For 2nd Floor
Providing of 120 minutes Fire rated lead lined doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the Indian Standard : 3614 Part 2 and British Standard : 476 part 22 with standard heating conditions as specified in Indian Standard : 3614 Part II 1992 and British Standard : 476 part 20 and 22 1987 to achieve the required integrity, insulation and stability (that is to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with Non Combustible by Nature technology and tested for radiation at NTH in accordance to AERB norms. - Shutter : Providing and fixing of 57 milimetre thick asbestos free composite, 'TUFWUD' brand - 3 criteria - fire, heat and smoke check Lead Lined Door Shutter with flame guard of 120 minutes Indian Standard : 3614 part -II comprising of 2 milimetre X 9 milimetre Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 pounds per inch pressure as per Indian Standard : 401 and kiln seasoned to moisture below 15 percent as per Indian Standard : 1141 frame work of 100 milimetre X 30 milimetre with 30 milimetre thick infill of ceramic fibre (density 128 kilogram per cubic metre) vermiculite mix, 3 milimetre thick Lead Sheet on one side faced and 3 milimetre Fire retardant High Density Fibreboard, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray coated with 2 coats of in-tumescent paint of minimum 300 micron and with 1 row of Brush-Type Astroflame® intumescent strip (imported) of size 10 milimetre X 4 milimetre concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. (For Ground Floor)
For First Floor
For 2nd Floor
Providing and fixing vertical blinds of approved make and shade of 100 milimetre regular fabric with powder coated aluminium channel with telting polyvinyl chloride chain and bottom weight plate with all necessary fixtures and fitting, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing rollar blinds of approved make and shade of 38 milimetre round aluminium channel with blackout fabric and telting with chain (ball) system with all necessary fixtures and fitting, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Fire exit and floor identification signage as per manufacturer's specifications, ADA compliant and modular system. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
ADA compliant modular multilingual and tactile emergency evacuation map of each floor indicating the current position of the viewer saying "YOU ARE HERE" of 15 milimetre height letters in red with white background, indicating the emergency exits, locations of fire extinguishers, excetra Signs shall have a solid header with the text “EVACUATION PLAN” in contrasting uppercase letters no less than 3/4 inch in height. The size of the board shall be 2 feet X 2 feet and shall be installed at a height of 1200 milimetre from finished floor level and shall be oriented to the position of the viewer as per the direction of the site engineer. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
For 5th Floor
Providing and installing bio digester unit based on Defence Research and Development Organisation technology made of fibre reinforced plastic having composition and following technical specifications and including necessary pipe and accessories up to 3 metre length, excluding the necessary excavation for installing the bio digester. - Percentage of fibre glass (glass content in fibre glass should be minimum 30 percent) : 33.33 percent, Percentage of polyester resin : 66.67 percent, Water absorption (as per ASTM) : 0.30 percent, Flammability as per ASTM, Tensile strength : 115 MPA, Specific Gravity at 25 degree centigrade : 1.45, Izod impact strength : 65 kJ/sqm, Heat defection / distort temperature : 65 degree Centigrade, Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid polyvinyl chloride : 100 milimetre, Outlet pipe size rigid polyvinyl chloride : 80 milimetre, Gas outlet rigid polyvinyl chloride with valve : 20 milimetre, Bacteria immobilization polyvinyl chloride mattes (on all partition). With Defence Research and Development Organisation TOT licensee and latest batch certificate(month and year of supply) and capacity as below - Up to 500 user - size 6.0 metre X 2.0 metre X 1.6 metre, Capacity of biodgester : 20000 liters, Area of top, bottom and side walls : 50.72 sqm, Area of partition walls : 13.36 sqm, Total weight of fibreglass reinforced polyster : 917.86 kg, Bacteria inoculums quantity : 7000 litres, Minimum thickness of side walls / top and bottom : 9 milimetre, Number of inside partitions : 4, Minimum thickness of partition wall : 4 milimetre.
Providing and installing bio digester unit based on Defence Research and Development Organisation technology made of fibre reinforced plastic having composition and following technical specifications and including necessary pipe and accessories up to 3 metre length, excluding the necessary excavation for installing the bio digester. - Percentage of fibre glass (glass content in fibre glass should be minimum 30 percent) : 33.33 percent, Percentage of polyester resin : 66.67 percent, Water absorption (as per ASTM) : 0.30 percent, Flammability as per ASTM, Tensile strength : 115 MPA, Specific Gravity at 25 degree centigrade : 1.45, Izod impact strength : 65 kJ/sqm, Heat defection / distort temperature : 65 degree Centigrade, Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid polyvinyl chloride : 100 milimetre, Outlet pipe size rigid polyvinyl chloride : 80 milimetre, Gas outlet rigid polyvinyl chloride with valve : 20 milimetre, Bacteria immobilization polyvinyl chloride mattes (on all partition). With Defence Research and Development Organisation TOT licensee and latest batch certificate(month and year of supply) and capacity as below - Up to 150 user - size 3.2 metre X 2.0 metre X 1.25 metre, Capacity of biodgester : 8000 liters, Area of top, bottom and side walls : 25.80 sqm, Area of partition walls : 10.0 sqm, Total weight of fibreglass reinforced polyster : 397.08 kg, Bacteria inoculums quantity : 3200 litres, Minimum thickness of side walls / top and bottom : 7 milimetre, Number of inside partitions : 4, Minimum thickness of partition wall : 4 milimetre.
Providing and constructing recharge pit of 2.0 metre deep and 1.0 metre diameter of pre-cast reinforced cement concrete rings with 6.5 Inch diameter X 25 metre deep borewell at the floor of recharge pit including installation of combination of solid / perforated polyvinyl chloride casing pipe wrapped around with netlon mesh including 300 milimetre thick sidefilling around outside of reinforced cement concrete rings (annular space) with 40 milimetre size boulders including filling of recharge pit up to 0.5 metre depth with 25-75 milimetre clean washed gravels from bottom up followed by 0.5 metre depth of 10-25 milimetre of clean washed stones followed by 0.5 metre of washed river fine aggregate (natural sand / crushed sand VSI grade finely washed excetra) including netlon mesh between each gravel / fine aggregate (natural sand / crushed sand VSI grade finely washed, excetra) media layer including covering with reinforced cement concrete slab, manhole frame and cover, polyvinyl chloride rungs, polyvinyl chloride end-caps, fittings, excetra including arrangement for inlet and outlet pipe excavation and backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Providing and laying in situ cement concrete M-30 with tremix treatment for 200 milimetre thickness for concrete road including laying plastic sheet of 125 micron thickness with groove cutting of 4 milimetre wide and 20 milimetre deep with necessary refilling with bitumen (excluding reinforcement) with coarse and fine aggregate (V.S.I. grade finely washed crushed sand) excetra complete.
Providing and fixing heavy duty inter locking concrete rubber mould glossy paving blocks of 80 milimetre thickness of having a strength of 400 kilogramme per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning, excetra complete.(using 100 percent crushed sand)
Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).
Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.)with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Providing and laying cast in situ / Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Providing and fixing reinforced cement concrete cover of size 90 centimetre X 45 centimetre with frame over inspection chamber, excetra complete. - heavy duty (225 kilogramme)
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailling out water manually, striking joints, racking out joints and watering, excetra complete. (using ARTIFICIAL SAND).
Construction of dry lean cement concrete sub-base over a prepared sub-grade with coarse and fine aggregate (V.S.I. grade finely washed crushed sand) conforming to Indian Standard : 383, the size of coarse aggregate not exceeding 25 milimetre, cement content not to be less than 150 kilogram per cubic metre, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant / weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor / by suitable means as approved by Engineer in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required, excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.
Providing and laying of hot applied thermoplastic compound 2.5 milimetre thick including reflectorizing glass beads at the rate of 250 grams per square metre area, thickness of 2.5 milimetre is exclusive of surface applied glass beads as per Indian Road Congress : 35. The finished surface to be level, uniform and free from streaks and holes complete.
Painting line, dashes, arrows, excetra on roads in two coats on new work with ready mixed road marking paint confirming to Indian Standard : 164 on bituminous surface including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control. - Over 10 centimetre wide on new surface.
Providing and fixing in position thermo mechanically treated FE 500, tie bars precoated with anticorrosive epoxy paint, of 12 milimetre diameter 70 centimetre long and at 30.00 centimetre center to center and wherever directed including handling, straightening, wrapping with paper of approved quality for half length, necessary cutting, handling, supported by assembly of thermo mechanically treated FE 500 chairs with proper alignment, excetra complete.
Providing waterproof plaster in water closet and bath 20 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of one kilogram per bag of cement of approved make and manufacturer and curing and filling joints of nahani trap and any outlet properly, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Providing and fixing kerbstone with led lighting system as per following specifications: dimensions with vertical mounting legs with 10 milimetre horizontal square shape mild steel reinforcements. Illuminated kerb stone having visible dimensions :- 500 milimetre X 150 milimetre X 150 milimetre.(as per Indian Road Congress - 86-1983 ) 80 milimetre legs having mild steel reinforcements shal be embedded in black topped / concrete road surface. The kerb stone should have kerb angle of 45 degree, with rubber plugs at both ends of the kerbstones (2 Nos) having load carrying capacity - vertical : 1465 Kg, horizontal : 2349 Kg (certified by govt. Recoganized bodies) having thermal stability -: -40 to +120 degree celcius (certified by govt. Recoganized bodies. Illuminated kerb stones including : ingrace protection and connector rating IP-67, electrical wire -(as per Indian Standard : 694), led strip (as per lm:80) standard. Including for electrical fixing -fibreglass reinforced polyster junction box consisting of - 10 amp. Switch module power supply (SMPS) having input voltage - 230 V AC, output voltage 36 V DC, 2 pole M.C.B. Illuminated kerb stones having warranty for 3 years. illuminated kerbstone shall be fixed into cast-in-situ cement concrete of M-20 grade at base, back filling and grooves, including dismantling, fixing, removal of dismantled material and cleaning excetra Complete. The colour of kerb stone shall be provided as directed by engineer in charge.
Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fiber glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 square metre per kilogram with two coats Using approved chemicals for masonry and concrete surface by brush, covering seven years gaurantee on stamp paper, excetra complete. (For Ground Floor)
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fiber glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 square metre per kilogram with two coats Using approved chemicals for masonry and concrete surface by brush, covering seven years gaurantee on stamp paper, excetra complete. (For 5th Floor)
Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND).
Providing and fixing white Opal series European type wall-hung, of size 400 milimetre X 370 milimetre X 575 milimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 milimetre diameter cast iron plug bend inlet pipe all fittings, cutting and making good walls, floors, excetra as directed by Engineer in charge. (For Ground Floor)
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve having flow rate up to 4.0 litre per minute of Jaquar/ Cera/ Hindware/ Perryware or equivalent make with polyvinyl chloride waste pipe with fitting arrangement, excetra complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) (For Ground Floor)
Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/ Cera/ Hindware/ Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) (For Ground Floor)
Providing and fixing chromium plated two way bib cock of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor)
C.P. Handshower (Health Faucet) 1m. polyvinyl chloride Tube with wall hook Jaquar Make Continental (Cat number ALD-563)
Providing and fixing chromium plated towel rod 16 milimetre diameter and 75 centimetre in length including all accessories complete. (For Ground Floor)
C.P. Soap Dish (Polyurethane) Jaquar Make Continental (Cat number AQN-7733)
Providing and fixing 450 milimetre X 550 milimetre size superior type belgium mirror with 16 milimetre diameter nickel plated towel rod, excetra complete. (For Ground Floor)
Providing and fixing table top white wash basin of size 120 milimetre X 635 milimetre X 405 milimetre rubber plugs and brass chain, with pillar cock, C.P. angular stop cock long thread, continental including stainless steel bottle trap of approved make having necessary pipe connection up to theoutside face of the wall, excetra complete as directed by Engineer in charge. (For First Floor)
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 milimetre X 590 milimetre X 195 milimetre size with pillar cock, C.P. Angular stop cock, long thread of approved make continental including stainless steel bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, excetra Complete as directed by Engineer in charge. (For Ground Floor)
Providing and fixing wall hung white wash basin of size 550 milimetre X 400 milimetre X 195 milimetre with pillar cock having flow rate up to 6.0 Litr/Minute, C.P. Angular stop cock long thread of Jaquar/ Cera/ Hindware/ Perryware or equivalent make including stainless steel bottle trap of approved make, etc. complete as directed by Engineer in charge. (For Ground Floor)
Bib Tap - 12 milimetre Brass Medium
Providing and fixing stainless steel sink 600 milimetre X 510 milimetre X 200 milimetre of approved make including coupling, outlet pipe, elbo and other necessary fitting, finishing excetra complete. (For First Floor)
Providing and fixing chromium plated sink cock with raised J shaped swinging casted spout of approved make including necessary sockets / union nut, excetra complete. (For First Floor)
Providing and fixing chromium plated angular stop cock with wall flange of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor)
Providing and fixing 50 milimetre diameter water metre with non-return value including stainer, sockets / union nut including water metre box making locking arrangement and lock. [Without chamber].
Providing and fixing 15 centimetre rigid poly vinyl chloride nahani trap including poly vinyl chloride grating, bend, connecting piece of unplasticized poly vinyl chloride pipe upto the outside face of the wall, making good damaged surface and testing, excetra complete.( Prior approval of sample and brand by Ex. Engr.is necessary before use) (For Ground Floor)
Providing stainless steel grab bars set for accessible toilets comprising of 4 numbers grab bars as specified below. (1 number wing grab bar + 1 number L shaped grab bar + 2 numbers straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a stainless steel 304 SWING HANDICAP GRAB BAR - 700 milimetre and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing stainless steel 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness milimetre of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 milimetre),32MM DIA. and thickness 1.5mm of the approved brand and make. (For Ground Floor)
Providing and fixing 100 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps, excetra complete. (For Ground Floor)
Providing and fixing 75 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps excetra complete. (For Ground Floor)
Providing, laying and fixing polyvinyl chloride pipe of 50 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete. (For Ground Floor)
Providing, laying and fixing polyvinyl chloride pipe of 40 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete. (For Third Floor)
Providing, laying and fixing polyvinyl chloride pipe of 32 milimetre diameter with fittings, such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete. (For Ground Floor)
Providing and fixing on walls / celling / floor, 20 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
Providing and fixing on walls / celling / floor, 25 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
Providing and fixing on walls / celling / floor, 32 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
Providing and fixing on walls / celling / floor, 40 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
Providing and fixing on walls / celling / floor, 50 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete. (For Ground Floor)
Providing and fixing heat insulation by wrapping the pipes with glass wool / asbestos fibre rope or tape / videoflex 25 milimetre as directed by Engineer in charge. (For First Floor)
Providing and fixing heat insulation by wrapping the pipes with glass wool / asbestos fibre rope or tape / videoflex 32 milimetre as directed by Engineer in charge. (For Ground Floor)
Ball cock for 25 milimetre dia
Ball cock for 32 milimetre dia
Ball cock for 40 milimetre dia
Ball Valves for 50 milimetre dia
Providing and fixing 40 milimetre diameter ball cock medium type with polyvinyl chloride float including sockets and necessary fittings and tested as per municipal requirements, excetra complete. (For Terrace Floor)
Strainer for 50 mm
Strainer for 40 mm
Providing and fixing poly vinyl chloride rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 milimetre to 2.7 milimetre confirming to Indian Standard : 13592-1992 including proper rain water receiving recess with poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40 milimetre from face of wall affixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge excetra complete. (For Ground Floor)
Providing, constructing and fixing 450 milimetre diameter Inspection chamber made up of polypropylene / polyethylene material of thickness 3.5 milimetre and height of 388 milimetre with 160 milimetre or 200 milimetre main inlet(s) and outlet 110 milimetre and / or 160 milimetre branch inlets, with 450 milimetre diameter Ultra shaft pipe of high density polyethylene material having height of 460 milimetre, having reinforced cement concrete cover and frame fixing in 150 milimetre thick in cement concrete 1:2:4, having crushed sand bed of 150 milimetre thick of size 750 milimetre dia, including excavation and refilling the sides of chamber by sand crushed cushioning 150 milimetre thickness, connecting all required unplasticized poly vinyl chloride fittings with rubber lubricant, excetra complete. (For Ground Floor)
Providing, constructing and fixing 600 milimetre diameter Inspection chamber made up of Polypropylene / polyethylene material having 315 milimetre diameter inlet(s) / outlets and with eccentric reducers as per requirement to connect 160 milimetre and 200 milimetre pipes having thickness of 5 milimetre and 600 milimetre in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 milimetre having reinforced cement concrete cover and frame fixing in 150 milimetre thick in cement concrete 1:2:4, having crushed sand bed of 150 milimetre thick of size 750 milimetre diameter including excavation and refilling the sides of chamber by sand crushed cushioning 150 milimetre thickness, connecting all required unplasticized poly vinyl chloride fittings with rubber lubricant, excetra complete. (For Ground Floor)
Providing and constructing recharge pit of 2.0 metre deep and 1.0 metre diameter of pre-cast reinforced cement concrete rings with 6.5 Inch diameter X 25 metre deep borewell at the floor of recharge pit including installation of combination of solid / perforated polyvinyl chloride casing pipe wrapped around with netlon mesh including 300 milimetre thick sidefilling around outside of reinforced cement concrete rings (annular space) with 40 milimetre size boulders including filling of recharge pit up to 0.5 metre depth with 25-75 milimetre clean washed gravels from bottom up followed by 0.5 metre depth of 10-25 milimetre of clean washed stones followed by 0.5 metre of washed river fine aggregate (natural sand / crushed sand VSI grade finely washed excetra) including netlon mesh between each gravel / fine aggregate (natural sand / crushed sand VSI grade finely washed, excetra) media layer including covering with reinforced cement concrete slab, manhole frame and cover, polyvinyl chloride rungs, polyvinyl chloride end-caps, fittings, excetra including arrangement for inlet and outlet pipe excavation and backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Providing and fixing 15 centimetre X 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting Green colour earth with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting Green colour earth with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(with note 3)
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting Green colour earth with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG_x0002_MA/BW(with note 3)
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting Green colour earth with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG_x0002_MA/BW(with note 3)
Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting Green colour earth with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG_x0002_MA/BW(with note 3)
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell-push with indicator 2 modules 6A / 10A, duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16/18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG_x0002_PW/CW
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+2E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG_x0002_PW/CW(With note 3)(Two Way Control)
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG_x0002_PW/CW
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG_x0002_PW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG_x0002_PW/CW
Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification no. APWCR/ WC
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 4 Pole MCCB, 415V, 100 A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB (with note1)
Providing & erecting 4 Pole MCCB, 415V, 200 A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB (with note1)
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 8 ways Four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
Design, fabrication, assembling, supply,installation, testing and commissioning of cubicle type LT panels as per IEC 61439 -Part 1 & 2 suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates l/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports, with bottom base channel of MS section not less than 75mm X 50 mm x 5 mm thick, entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable,cable alleys,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels. Rate shall inclusive of all required all accessories circuting indication lamps, MFM & all other as shown in SLD. MAIN LT PANEL,INCOMER :500 A FP MCCB - 1 Nos.500 A MCCB SPREADER LINK - 1 Nos.Surge Protection device ( TPN Type 1+2 ),CT 500A/5A 10 VA CL 0.5 - 3 Nos.,Indicating lamp 240V AC R/Y - 2 Nos.Indicating lamp 240V AC B -1 Nos.Indicating lamp 240V AC On/Off/trip - 3 Nos.Multifunction Meter - 1 Nos.2A SP MCB - 6 Nos.Bus Bar Support,Outgoing Section,200 A FP MCCB Feeder - 5 Nos.200 A MCCB SPREADER LINK - 5 Nos.Indicating Lamp 240 V AC ON -5 Nos.Indicating Lamp 240 V AC Trip - 5 Nos.160 A FP MCCB Feeder - 2 Nos.160 A MCCB SPREADER LINK - 2 Nos.Indicating Lamp 240 V AC ON - 2 Nos.Indicating Lamp 240 V AC Trip - 2 Nos.100 A FP MCCB Feeder - 6 Nos.100 A MCCB SPREADER LINK - 6 Nos.Indicating Lamp 240 V AC ON - 6 Nos.Indicating Lamp 240 V AC Trip - 6 Nos.Aluminum Bus Bar Size with 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm.50 mm X 10 mm,50 mm X 10 mm,50 mm X 5 mm
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware.
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA (UPS, X-Ray room, OT-1 to 5, server)
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP (Main LT panel, Electrical room 1 & 2 )
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA_x0002_EP.
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 10 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW
Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying, erecting & commissioning 30 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.(with note -Add Rs. 38159.00 for additional 16 extension card for digital (hybrid) type EPABX -two numbers)
Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.
Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC
Supplying and erecting LSZH armoured multimode optical fibre cable with 12 fibres, core dia 50/125 µm (OM4) suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG_x0002_NWC/GBS
Supplying, fixing, and configuring 1-port mini - GBIC SX MM fibre transceiver (up to 550m, support 3.3V power) erected in provided rack complete.
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAK
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 2 way Indoor/outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 1 no. feeder with 1 LBS and 1 no. feeder with 1 VCB compliant to IEC 62271 -100,2 00 and 102, as per specification no. SW_x0002_HTS/RMU SCADA
Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A, VA10 or 15, Class 0.5S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.5 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.
Supplying and erecting 75 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 315 kVA, mineral oil immersed and naturally cooled indoor type, Copper wound ,without gas cushioning ,hermetically Sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%,having 7 number of tap positions, with standard accessories complete with test certificate with losses below 1025 Watts at 50% load, 3100 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL (With Note 1) (Indoor Type)
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram)
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA_x0002_EP.
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 320 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 54.89 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 480 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 250 kVA up to 320 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Excavating soft murum / soft soil road by chiselling for preparing pit for polesstay or earth plates or for laying cables, pipes & clearing the site by removingdebris & making the site good complete. (320KVA = 5.35m X 2.30m)
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). (320KVA = 5.35m X 2.30m X 0.3m )
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Providing and back filling ground enhancing compound 25 kg bag complete.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected
Supplying and erecting 15m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
Supplying & erecting HDMI Extender Over RJ45 Ethernet Cable Cat 6, 60m/200ft complete
Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of 0.5 hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS (For CCTV System)
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying and erecting G.I. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP
Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole)
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed,FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM.
Supplying & erecting of High definition 4/5 Megapixel IP IR PTZ Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS Video Resolution: minimum 2880 x 1620 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame Rate : minimum 30 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant. Auto Tracking, Pre-set Tour Settings, Pan : 360° endless, Tilt : From -15° to 90° (auto-flip 180°), minimum Pan Speed - from 0.1°/s to 160°/s, minimum Preset Speed: 240°/s, minimum Tilt Speed - from 0.1°/s to 120°/s, minimum Preset Speed : 200°/s, Min Presets- 250, Min IR distance :150m, Lens Type : minimum 4.3 - 12.5mm Lens min 16 x digital zoom, min 30 x optical Zoom. Focus Mode : Auto/Zooming/One Push Manual, Lux sensitivity- minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance Min IR- 150m, Power Supply : support 12/24 VDC, 24 VAC & PoE, IP67/IP66, IK10, built in micro SD/SDHC/SDXC card slot minimum 256 GB, built in microphone. minimum Input/Output : Audio in × 1, Audio Out × 1, Alarm in× 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security : User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed, FTP disabled. Protocol-DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP),Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no CCTV-CAM.
Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps self_x0002_adaptive Ethernet interface, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR
Supplying & erecting 55" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV (15 Pole x 6 mtr = 90 +Flood light cable 12 x 12.5 mtr =150 + Flood light cable 4 x 9 mtr =36 )
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED flood light fitting Max. 120W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting Gate/garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG_x0002_ODF/GLT
Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OH_x0002_PL/HM (excluding luminaries)
Supply and erecting 9m (clear height) Fixed type high-mast (Top-100mm, Bottom- 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. OH-PL/OPL (excluding luminaires).
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, , IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole)
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole).
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing and commissioning MCB type change over switch 4 pole, 25A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying, erecting & terminating FR- XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR- XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete.
Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 475 LPM discharge at 36 to 10 m head & discharge & delivery Pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP (Borewell Pump)
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (Drinking pump, Domestic Pump -1&2, Flushing pump)
Supplying & erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
Supplying & erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos)
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
Supplying, installing, testing and commissioning FR- XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete.
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG_x0002_PW/CW (with Note 3)(Two way point)
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
SITC of Electric Traction Passenger Lift with Rated capacity :- 16 Passenger/1088Kg , Floors :- G+ 5 floor (6 Stops/6 Landings) , Travel :- 3.9 to 24 mtrs , Location of Lift Machine:- MR/MRL , Rated speed :- 1.0mps VS , Car/Landing door clear opening of 1000mm wide x 2000 mm high, Clear Car size of 2000mm wide x 1300 m deep x 2250mm high , Lift shaft available having clear size of 2500 mm wide x 2100 mm deep, 2100 mm Pit depth, 3900 mm Overhead. Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with Rated capacity :- 20 Passenger/1360Kg ,Floors :- Floors :- G+ 5 floor (6 Stops/6 Landings) , Travel :- 3.9 to 24 mtrs ,Location of Lift Machine:- MR/MRL , Rated speed :- 1.0mps VS ,Car/Landing door clear opening of 1100/1200 mm wide x 2000 mm high , Clear Car size of 1300 mm wide x 2400 mm deep x 2250mm high, Lift shaft available having clear size of 2200 mm wide x 3000 mm deep, 2400 mm Pit depth, 3900 mm Overhead. Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Lift having 1200mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.
For Full Collective control system, add as below. For Lift travelling above First floor & up to Sixth floor
Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 150 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.
Supplying, installing, testing and commissioning of Commercial Heat pump, having dimension: 1020 x 846 x 1840 (mm), Input power: 6.02 kW, 400 V, 3 Ph, 50 Hz, Output power: 19.8 kW having hot water temperature range 35°C to 52°C and ambient temperature range for max. efficiency 7°C to 43°C, centrally controlled operation, operational noise level: 65 dBA with necessary accessories complete with 5 years ON-SITE warranty
Supplying, installation and testing and commissioning of storage type Mild Steel mixing water tank of capacity 3000 ltrs. tested to a pressure of 8 kg/cm2 insulated with 50 mm thick rock wool with wire mesh around and cladded with 26 SWG aluminium of dish end type with working pressure of 6 kg/cm2, fabricated with 6 mm thick MS plate and dished ends with 8 mm thick plates complete with man hole cover, inner side of the tank coated with FRP coating of 3 mm thickness withstand temperature of 90°C provided with collars of 2" BSP for provision to install 6 numbers of electrical heating coils if required with thermal sensors for automatic operation and integrated into the electrical circuits of the circulation pumps and the heat pump with safety valve drain, inlet and outlet nozzle, pressure gauge with all necessary accessories complete (storage Tank)
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 75/80 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 200 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia cast iron double flange NRV completewith PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV ( 12 Qty For Six floor & 1 Qty For Pump Room)
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF_x0002_FFA/NZ
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF_x0002_FA/FMC
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) ( For Fire Shaft)
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (Note increase rate by 2% for FRLS)
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF_x0002_AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.0 sq. mm speaker wire complete.
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF SPR
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Providing Round bottom FIRE Bucket of 9 Litres capacity as per IS 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark on provided stand/ wall hook.
Supplying & installation auto glow (Viewing upto 15 mtr length) fire signages viz fir hydrant Fir Extinguishers Fire Exit Fire door Fire house box ect. Size of 600x200 mm
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. (as per note 2 - For drain piping refer rates of PVC pipes from chapter no. 1)
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC ( Ground floor -Consulting room 1 to 5)
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC (Ground floor - minor OT & X-ray)
Supplying, installing, testing & commissioning split type room air conditioning unit 2.8TR to 3.2TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC (First floor - OT 1 & 2, Second floor - OT 3 &4, NICU area)
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. (with note 2)
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Shah EPC Services & Projects Private Limited (BID ID -6261790)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid