Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹1.1 L+₹6,222 (5.82%)Rejected-AOC SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L2 | Rejected-AOC 2ND LOWEST BIDDERS |
| Sl No | Description | Qty | Unit | RAMKRISHNA ELECTRONICS L2 | GOSWAMY BROTHERS L1 |
|---|---|---|---|---|---|
| 1.00 | Supply & delivery of Inverter type split Air-conditioner machine having cooling capacity not less than 5000W, ISSER 3.8 to 4.39,BEE rating not less than 3 star, Noise level not more than 50db. This Split Air Conditioning machine fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A. (O-General /Daikin/Hitachi/Mitsubishi Electric/Mitsubishi Heavy Industries as per approved by EIC/authority). | 2 | Each | 43,000 ₹86,000 | 37,412 ₹74,824 Lowest |
| 2.00 | Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC. | 15 | Mtr. | 100 ₹1,500 Lowest | 500 ₹7,500 |
| 3.00 | Installation, testing & commissioning of the above-said split ACs incl. supply & fixing required Angle Iron Structure on wall for placing outdoor unit & mending good the damages as per direction of E.I.C. | 2 | nos | 1,800 ₹3,600 | 1,500 ₹3,000 Lowest |
| 4.00 | Supply & Laying of 4 core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/KEI/Polycab as approved by E.I.C) | 18 | Mtr | 120 ₹2,160 | 112 ₹2,016 Lowest |
| 5.00 | Supply & Laying 20 mm hard PVC pipe (heavy type) for water drainage. | 20 | Mtr | 60 ₹1,200 Lowest | 60 ₹1,200 Lowest |
| 6.00 | Charges for dismantling of existing Split AC machines including existing indoor /outdoor unit, cu.pipes & wires etc. including all others accessories incl. mending good damages as per GS and clearing/removing from the site as per direction of EIC. | 2 | nos | 250 ₹500 Lowest | 600 ₹1,200 |
| 7.00 | Add. G.S.T.@ 18% on total value. | 1 | Item | 17,093 ₹17,093 | 16,153 ₹16,153 Lowest |
| 8.00 | Add. LWC.@ 1% on total value | 1 | Item | 1,121 ₹1,121 | 1,059 ₹1,059 Lowest |
Tender Value
Refer Docs
EMD Value
₹2,337
Closing Date
10 Jun 2025, 1:00 pmClosed
AE NSESD, PWD
GOVERNMENT OF WEST BENGAL OFFICE OF THE ASSISTANT ENGINEER New Secretariat Building Electrical Sub-Division PUBLIC WORKS DIRECTORATE New Secretariat Building, C Block, 4th floor 1, K.S Roy Road, Kolkata 700001
Replacement of old room Air-Conditioning machines installed at the Office Chamber of the Joint Secretary and Sr. Deputy Secretary of Labour Department at A Block, 12th Floor of New Secretariat Building, Kolkata-700001
2025_WBPWD_852798_1
WBPWD/AE-NSESD/NIQ-03/2025-26 (2ND CALL)
Open Tender
A/C ORG
Item Rate
7 days
NS BUILDING
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,337
16 Jun 2026
26 May 2025
12 Jun 2025
26 May 2025
10 Jun 2025
26 May 2025
Amount
Supply & delivery of Inverter type split Air-conditioner machine having cooling capacity not less than 5000W, ISSER 3.8 to 4.39,BEE rating not less than 3 star, Noise level not more than 50db. This Split Air Conditioning machine fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A. (O-General /Daikin/Hitachi/Mitsubishi Electric/Mitsubishi Heavy Industries as per approved by EIC/authority).
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.
Installation, testing & commissioning of the above-said split ACs incl. supply & fixing required Angle Iron Structure on wall for placing outdoor unit & mending good the damages as per direction of E.I.C.
Supply & Laying of 4 core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/KEI/Polycab as approved by E.I.C)
Supply & Laying 20 mm hard PVC pipe (heavy type) for water drainage.
Charges for dismantling of existing Split AC machines including existing indoor /outdoor unit, cu.pipes & wires etc. including all others accessories incl. mending good damages as per GS and clearing/removing from the site as per direction of EIC.
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
RAMKRISHNA ELECTRONICS (BID ID -6462540)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .