Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC 23 6 C LAL VIHAR EAST END BAMRAULI PRAYAGRAJ 211012 U P | PRAYAGRAJ | UTTAR PRADESH | 211012 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.1 L+₹2.6 L (6.02%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹45.2 L+₹2.6 L (6.21%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
₹44.9 L
EMD Value
₹89,840
Closing Date
4 Apr 2023, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
SPECIAL REPAIRS TO ELECTRICAL WIRING AND ALLIED SERVICES OF SMQs AT HAPPY HOME AND OTHER SANCTION WORKS AT AF STN UNDER GE (AF) BAMRAULI
2023_MES_580375_3
8769
Open Tender
Civil Works
Works
180 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹89,840
Yes
12 May 2023
16 Mar 2023
11 Apr 2023
16 Mar 2023
4 Apr 2023
22 Mar 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for light shade vitrified ceramic tiles (Premium quality)10 mm thick (square/ rectagular) polished,area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade tiles including 15mm thick screed bed layer in CM (1:6) complete all as specified and directed.
Providing and fixing in repair false ceiling of 16 mm thick fine fissurred RH-99 prime Make-Armstrong Tegular and accoustic purpose of size 600x600x16mm thick fixed in GI grid powder coated snap grid ceilling of l section 25 mm x25mmx1.5mm thick and Tsection 25mm x25mm x1.mm with suspender of 10 gauge GI wire of required length, fixed with dash through fastener bolt of approved quality 04 Nos for per sqm including necessary cuting, securing and making good to disturbed surface complete all as specified and directed
M&L for complete removal of existing treatment of old plastered surfaces of walls and applying two coats of plastic emulsion paint over a coat of primer with a thin layer of 1.5 mm thick wall care putty complete all as specified.
Demolition of brick work stone boulder masnary built in cement mortar including all quoins arches pillars, etc complete all as directed by Engineer –in-charge
S&F in repairs vitreous china wash basin, flat back of size 550x400 mmm etc complete all as specified & directed.
S&F in repairs PVC connection 600mm long with check nut etc complete all as specified.
S&F in repair V/C pedestal pan( EWC) and trap incl connection to drain or out going pipe & to flush pipe , anti syphonage piipe etc complete all as specified.
S&F in repair fancy type CP bib cock long body 15mm bore with wall flange alloy with crutch handle screwed down for iron pipe chromium plated fixed in 15mm bore pipe complete all as specified and directed.
S&F in repair PVC wast pipe of 32mm dia suitable for WHB,kitchen sink complete all as specified and directed.
S&F in repairs low level flushing cistern 10 ltrs capacity PVC ISI marks with complete fitting all as specified & directed.
S& F in repairs 15mm dia CP pillar taps, fency type, with capstan heads, screwed down high pressure with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 300x450x7 mm thick in set and jointed in neat cement slurry and pointed to white cement to match on the wall over 15 mm thick 1:4 screed bed etc complete all as specied and directed.
M&L for 300x300 mmx7-8 mm thick coloured non skid ceramic tiles in floor, set & jointed in neat cement slurry and pointed in white or colured cement to match over 20mm thick screed bed in cement morta 1:6 complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked including cutting and chasing and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets / fan regulator etc and making good surface as original by plastering and whitewash/ colour/ distemper etc, complete all as directed for one light point / fan point / exhaust fan point / bell / buzzer controlled by one 1-way switch/ bell push. (Note : The cost of modular type Metal boxes and modular accessories like inner/outer cover plates etc will be included in quoted rate.)
All as per srl item No. 17 here in before but point wiring for one socket outet point 5 amps on the independent board.
All as per srl item No. 17 here in before but point wiring for one socket outet point 5 amps on the Same board with other switchs complete
All as per srl item No. 17 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp light point.
Supply & fixing of Modular switch 6 Amp, 1 way, 1 module size complete all as directed.
Supply and fixing of Modular switch 16 Amp, 1 way, 1 module size complete all as directed.
Supply and fixing of Modular socket 6 Amp, 2/3 pin, multipurpose shuttered type, 2 module size complete all as directed.
Supply and fixing of Modular socket 16 Amp mulipurpose shuttered type, 3 module size complete all as directed.
Supply and Fix calling bell AC ding dong 220 volt multi music type as specified and directed.
Supply and fix Modular bell push AC 220 volt single phase
Supply and fix electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type
S & F Wall/surface mounted type LED light fitting batten type complete with LED lamp 9 - 10 watt (2 feet long), extruded aluminium heat sink provide for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper conductor cable, including taking down of existing light fitting etc complete all as specified and as directed.
Supply and fix polycarbonate ceiling rose surface mounted
Supply and fix Modular neon lamp indicator indicator(one module) 220 volt single phase
Supply and fixing of MCB 'C' Curve, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed.
All as per srl item No. 33 above here in before but SPN 40-63 amps capacity
Supply and fixing of Distribution Board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB's and isolators etc and making all necessary connections complete all as directed. Note: The cost of removing old wooden box and making good of surface as original i.e. brick work, plastering, white washing etc is included in quoted rate.
Supply and fix Verticle type TPN DB MCCB 125 Amp as incommer 4 way with three phase and single phase (TP/SP) MCB out going comprising 200 Amp insulated bus bar (Tinned electrolight copper) arrangement, shrouded neutral bar and earth bar, top and bottom removable gland plates, IP-43 protection, 440 volt 50 Htz Complete as all directed as specified by Engineer-in-Charge Note : MCCBs shall be measured and paid for separately under respective item of this schedule.
Supply and fix MCCB four pole 125 Amp rating 16 KA 415volt 50 Htz adjustable type including spreader link for both side incomer and out going.
Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as directed. Note : 1. The conduit and conduit accessories shall be deemed in quoted rate no extra payment will be made in this account. 2. The two run of 6 Sqmm wire and one run of 4 Sqmm wire will be measured as one unit.
Material and labour for earthing complete with GI earth plate electrode 600 mmx 600mm x 6mm thick burried directly in ground not less than 2.25 mtrs below ground level, with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B 1 pit, cover frame, GI pipe 15mm dia light grade for protection of earthing lead and GI pipe 20 mm dia for watering pipe with funnel, wire mesh, salt, charcoal dust and excavation, as given in SSR-I complete all as directed.
Taking down carefully existing ceiling fan and M&L for rifixing the same with nuts, with lock type split pin spring & plate washers etc after paining and oiling/greesing as specified and directed.
M&L for point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly One light/fan/bell point controlled by one by one way switch.
S&F switch piano flush type 5 Amp SP one way .
S&F LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, system lumen efficiency >90 lumen/watt, 6500k and including connecting from ceiling rose to fitting incl taking down old unsv light complete all as specified and directed.
S&F LED batten luminaire surface mounted,2 feet system wattage of 10 Watts, system lumen efficiency >90 lumen/watt, 3200k and including connecting from ceiling rose to fitting incl taking down old unsv lightcomplete all as specified and directed.
Supply and fix in replcement flood light 30 watt 240 volt 50 Htz 3000/6500K 120 lumen/watt IP-65 complete all as spd and directed.
Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 1.5 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 1.5 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 1.5 sqmm cable and one run of 1.5 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Supply and Fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
Supply and fix 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix LED 2 X 2 ft backlite surface mounted fitting 36 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed.
S & F sheet metal enclosure with socket and plug top and MCB single pole and neutral enclosure with two Pin and earth plug and socket complete with one single pole MCB, 240 V, 20 Amp.
Supply and fix wall mounted fan 400mm size, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system complete all as specified and directed.
M& L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
All as per item No 17 here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4.0 sq mm size as earth conductor for one 16 Amp switch socket outlet on independent board.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items of this schedule. The same shall be recovered from various payment to contractor before handing over old material.
M/S Rakesh Singh
M/S Shivam Industries
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .