Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC INDEX NO B 132 HQ ADG P CHENNAI NO 229 ANGAPPAN STREET MITTANAMALLI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.8 L+₹33,848 (1.39%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹25.6 L+₹1.2 L (4.86%)Rejected-AOC NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹27.2 L+₹2.8 L (11.3%)Rejected-AOC NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹28.9 L+₹4.5 L (18.4%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
29 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Avadi
Garrison Engineer, Muthapudupet, Avadi, Chennai-55
ADDITION/ ALTERATION TO GUARD ROOM IN DOMESTIC AREA MAIN GATE AT OD AVADI AND REPAIR TO DRAIN WALLS, PATHWAY TO PRIMARY IN KV AFS UNDER GE AVADI
2022_MES_528121_2
8934
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer, Muthapudupet, Avadi, Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Avadi
₹48,000
Yes
28 Sept 2022
5 Jul 2022
5 Aug 2022
5 Jul 2022
29 Jul 2022
12 Jul 2022
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specfied and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth,etc and getting out hard/dense soil for foundation etc n exc 10 sqm on plan and not exceeding 1.5m depth complete all as specifed and directed.
All as per item No 2 above but depth exceeding 1.5m and not exceeding 3m depth.
M&L treating the bottom and sides of excavation at the rate of 5litres of emulsion per square metre of surface area complete all as specified and as directed.
M&L for Pre Antitermite treatment to the backfill in contact with foundation at the rate of 7.5ltrs of emulsion per sqm of vertical surface (Area of sub structure in concat with backfill to be measured) complete all as specified and as directed.
M&Lfor treating the top surface of filled earth at the rate of 5ltrs of emulsion per sqm of surface complete all as specified and as directed.
M&Lfor treating the soil under plinth protection at the rate of 5ltrs of emulsion per sqm of surface area complete all as specified and as directed.
M&L for PCC 1:5:10, typeE2, using 40 mm graded aggreage as in foundation filling and mass concrete complete all as specified and as directed. Note: Reinforcement and form work shall be measured and paid seperately.
M&L for Reinforced cement concrete design mix M-30 using 20mm graded stone aggregates for rafts,footings ,foundation beams , plinth beams,base for columns etc and mass concrete complete all as specifed and directed. Note: Reinforcement and form work shall be measured and paid seperately.
M&L for Reinforced cement concrete design mix M-30 using 20mm graded stone aggregates as coloumns, pillars, piers, post and struts complete all as specified and directed. Note: Reinforcement and form work shall be measured and paid seperately.
M&L for Reinforced cement concrete design mix M-30 using 20mm graded aggregates as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. Note: Reinforcement and form work shall be measured and paid seperately.
M&L for Reinforced cement concrete design mix M-30 using 20mm graded stone aggregates as in slab supported on walls, beams and colums in floors,roofs ,landing ,balconies,canopies,deck slabs and in shelves and the like complete all as specified and directed. Note: Reinforcement and form work shall be measured and paid seperately.
M&L for Reinforced cement concrete design mix M-30 using 20mm graded stone aggregates in chajjas complete all as specified and directed. Note: Reinforcement and form work shall be measured and paid seperately.
M&L for use and waste of formwork to sides of concrete foundations, footing ,bases of columns, raft and raft beams, sides and soffits if any of foundation and plinth beams and similar work; vertical to batter make rough finished surfaces complete all as specifed and as directed.
M & L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions and similar work; make rough finished surfaces complete all as specifed and as directed.
M & L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc, also splays between floors and beams; make rough finished surfaces complete all as specifed and as directed.
M & L for use and waste of formwork to suspended slabs such as roof slabs, floor slabs, floor slabs landings and similar work; not exceediing 200mm thick; make rough finished surfaces complete all as specifed and as directed.
M & L for use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openngs in concrete walls, floors and roofs n exc 20cm wide sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed.
M & L for use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
M&L for mild steel TMT bar of 10mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing clips complete all as specifed and as directed.
All as per item No 20 above but 5mm dia and over upto and including 10mm dia in stirrups, spacer and binder complete all as specifed and as directed.
Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
M&L for brick work with fly ash bricks, straingt or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specifed and as directed.
M&L brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM1:4 complete all as specified and as directed.
M & L for rendering 15mm thick in CM 1:4 in two layers 5mm thick using wpc over 10mm thick on brick work/ concrete wall surface and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick in CM 1:6 on brick work/concrete wall surface and finished even and smooth without using extra cement complete all as specifed and as directed.
M&L for rendering 5mm thick on concrete surfaces of ceiling in cement mortar 1:3 including finished even and smooth with out using extra cement all as specified and as directed.
Earth filling under floors or in foundations including watering and consolidation all as specified and as directed. Note: The earth obtained from excavation shall be used.
M&L for broken stone hard core of gauge not exceeding 63mm, deposited , spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface all as specified and as directed.
M&L for 100mm thick cement concrete, 1:4:8, type D2 using 40mm graded stone aggregate as in floor/sub base complete all as specifed and as directed.
M&L for 22mm thick PCC 1:2:4 type B0, using 12.5mm graded stone aggregate as in flooring, finished even and smooth without using extra cement all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C2, using 40mm graded stone aggregate as in plinth protection, finished fair and even all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for Non skid ceramic tiles coloured of size 400x400x 7 to 8mm thick (squar/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed in CM 1:4 all as specified and as directed.
M & L for Non-skid ceramic tiles coloured of size 300x300x7mm thick laid in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM 1:6 all as specified and as directed.
M & L for glazed ceramic tiles coloured of size 450x300x6-7mm thick fixed in verticle surfaces, set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick rendering in CM 1:4 all as specified and as directed.
Material and labour for Preparation of newly plastered surfaces of ceilings and applying three coats of white wash all as specified and as directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over the coat of alkali resistant priming paint complete all as specified and as directed.
M&L for preparing new surface of wall and applying two coats of Oil bound Distemper over a coat of alkali resistant primer and 3mm putty on new plastered surface complete all as specified and as directed.
M&L for preparation of old ceiling surfaces and applying two coats of white washing complete all as specifed and directed.
M&L for complete removal of existing treatment and applying two coats of cement base paint over the coat of alkali resistant priming paint complete all as specified and as directed.
Complete removal of existing treatment and treating with two coats of oil bound distemper over a coat of primer & 3mm putty to wall surfaces including preparation of old surface of wall all as specified
M&L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as directed.
M&L brushing neat cement slurry with 3.0kg of cement per sqm complete all as specified
M&L for 10 mm thick screed bed in cm 1:4 over levelling course, finished surface even/smooth without using extra cement with WPC all as specified and as directed.
Supply only Integral Water Proofing Compound conforming to IS all as specified.
M&L priming surfces and applying normal treatment (for moderate conditions) using glass fibre base bitumen felt , grade 2 complete all as specified.
M & L for applying evenly a tack coat of industrial bitumen 85/25 grade at the rate of 1.2 kg per sqm applied on the cleaned surfaces complete all as specified & directed.
M & L for APP based polymeric membrane with overlap of 100mm minimum weighing minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified.
M & L for applying one coat of bituminous aluminium paint @100gms/sqm complete all as specified and as per manufaturer's instructions.
Taking down chowkats or frames not exc 1.5Sqm each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Taking down chowkats or frames exc 1.5Sqm and not exc. 4Sqm each with shutters (without taking off shutters from the frames), complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification and drawings
S&F Factory made soild PVC profiled panel door shutter 28mm thick withintegral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as , with 'C type Gl or 40 x 20 x19 of MS pipe as stiffner & supplying & fixing in frame at site incl all fittings(handles/tower bolt/sliding bolt/hinges etc as per specifications & drawing.
M&L 18mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all as specified and as directed.
M&L fixed in repairs 18/19mm thick Block boards, grade 2quality, interior grade, commercial type, fixed with screws to timber frame-work all as specified and directed
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, of brass polished finish all as specified.
S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 all as specified and as directed.
S&F 100mm long Aluminium handles, cast type, anodised, all as specified and directed.
S&F mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and as directed.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed
Supply and fix Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified
S & F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminimum section weighing 0.55kg/m including necessay joining cleats, glazing clips, rubber packing, anodised aluminimum snap beading, screws etc. complete all as specified and as directed.
S&F for 100mm length aluminum, anodised, barrel tower bolts of extruded section and fixed all as specified and as directed.
S & F anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws, etc. complete all as specified and directed.
S&F aluminium (Die cast) body door closer hydraulically regulated designation No.3 universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg & fixed complete all as specified and directed.
M & L for 12mm thick prelaminated particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to aluminium frame work shutter.etc all as specified and as directed by Engr-in-charge
S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.50 Sqm in each pane complete all as specified and as directed
S & F aluminium rebated mortice lock vertical type size 100mm four lever complete all as specified and directed.
Taking up or down steel water tubings and connections of 15mm bore pipe complete all as specified and directed.
Taking up or down steel water tubings and connections of 20mm bore pipe complete all as specified and directed.
S & F 15mm Tubes, medium grade' galvanised, with all GI fitting and fixed complete to walls and ceilings or laid in floors all as specified and as directed.
S & F 20 mm Tubes, medium grade' galvanised, with all GI fitting and fixed complete to walls and ceilings or laid in floors all as specified and as directed.
S&F in repairs 15mm bore stop valve/Angle valve, chromium plated fancy type cast copper alloy, screwed down high pressure, with crutch or butter fly handle, screwed both ends for iron pipes or for unions and fixed of,complete all as specified and directed.
S&F in repairs 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe , all as specified and directed.
S&F 15mm bore Pillar taps bore cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe, complete all as specified
S&F in repairs 15mm bore Bib taps, cast copper alloy chromium plated with crutch or butter-fly handle screwed down, screwed for iron pipe or for brass ferrules, complete all as specified and directed.
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks (Cylinderical vertical with closed top) and fixed in position, all as specified in SSR Part-I, including dismantling of old water tank of any description, complete all as specified and directed.
S&F in repairs 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 142gms) complete all as specified and directed.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm,complete all as specified and directed.
S&F in repairs 125mm Chromium plated shower roses with or without swivel joints, including fixing to steel pipe or union all as specified.
S&F in repairs Tubular towel rail, brass chromium plated 20mm dia D type, 60cm long between flanges, complete all as specified and directed.
S&F in repairs Vitreous China squatting pan of 'Orissa' pattern of size 580 x 440mm, white, with integral foot rests, complete including provision of lime concrete bedding all as directed.
S&F in repairs 10 ltr capacity PVC valveless symphonic action type flushing cistern low level white with inlet ball valve, float and handle/push including brackets and PVC flushing pipe 32mm bore, complete all as specified.
S&F in repairs Vitreous China wash Basin (flat back or angle back type) , of size 550x400mm including brackets, waste coupling PTMT, and waste pipe PVC 32mm dia including cutting for and pinning in ends of brackets or erecting stand etc, complete all as specified.
S&F in repairs 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed
Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid dry or laid dry and pointed completed all as specified and directed.
M&L 100mm thick plain Cement concrete 1:5:10 type E2 using 40 mm graded stone aggregate thick as in sub base in path / hardstanding all as specified and as directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with Grey cement and no pigment over 15mm thick screed bed of CM1:4 all as specified and as directed.
M & L for 100mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and as directed.
All as per Item No. 93 above, but for 150mm dia pipe
M & L for PCC 1:3:6, type C2, using 40mm graded stone aggregate for concrete bed to drain pipe including packing under and haunching against the sides of pipes laid and tested for 100mm dia pipes, all as specified and as directed.
All as per Item No. 95 above, but for 150mm dia pipe
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding. 1.5m above the starting point complete all as specified and all as specified.
M & L for pre cast man hole cover slab in RCC 1:2:4, type B1, using 20mm graded stone aggregate, set in cement mortar 1:6 including necessary form work complete all as specified. Note : Reinforcement steel will be measured and paid separately.
M & L for brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified.
M & L for providing PCC 1:3:6, type C1, using 20mm graded stone aggregate as in coping including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified.
M & L for providing PCC 1:3:6, type C2 using 40mm graded stone aggregate as in surface channel complete all as specified.
M & L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick concrete surfaces and finished fair and even complete all as specified.
M & L PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation filling and mass concrete complete all as specified and as directed.
M & L for Screed bed or bedding layer of 10mm thick in cement mortor 1:3 for floor finishes all as specified and as directed.
M & L for PCC 1:2:4 type B1 using 20mm graded stone aggregate 80mm thick finished even and smooth w/o using extra cement
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor all as specified and as directed.
PVC (SWR) vent cowl 110mm all as specified and as directed.
PVC (SWR) junction single, single T equal or unequal all as specified and as directed.
M & L for Loose filling with aggregate of gauge 80 to 150mm all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified.
Cleaning of drains of any description and size not exc 1 Mtr on Width and not exc 1 Mtr depth including lifting up and removing sludge, accumulated solid sludge and other foreign materials and wash down with water for smooth functioing of drainage complete all as specified and as directed . Note : sludge and other material obtained from cleaning shall be removed from site and burried into the ground where directed.
Preparing black top surfaces by brushing with wire brushes for removing caked mud, loose materials etc., sweeping with mechanical blower or brooms to remove all loose dirt, materials etc., complete all as specified and as directed.
Applying evenly using pressure sprayer a priming / tack coat with bituminous primer of paving bitumen of Grade VG-10 at 5 kg / 10 Sqm over bituminous surfaces complete all as specified and as directed.
Bituminous premix semi-dense asphaltic concrete (SDAC), 40mm consolidated thickness with 5.5% minimum binder content by weight of total mix, (paving bitumen VG-30) and filler of 2 % cement, rolled and compacted to required camber and gradient complete using mechanical paver and rolled to a uniform, smooth surface using Tandem vibratory roller complete all as specified and as directed.
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia fixed on walls ,ceiling / roof trusses with suitable clamps and accessories etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls/fixed in wall, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for the following:-
(a) one light point controlled by one switch.
(b) one fan point controlled by one switch with regulator
(c) One Exhaust fan point controlled by one switch.
(d) One switch socket outlet 3 pin 5 Amps on same board along with other switches
(e) One switch socket outlet 3 pin 5 Amps on independent board.
All as per item No 140 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded FRLSH cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed.
S&F Switch piano flush type, single pole,5 Amps, 240 volts complete all specified.
S&F Switch socket 3 pin 5 amps , multi pin , flush type,complete all specified.
S&F Switch socket 3 pin 15 Amps, multipurpose, flush type complete all specified.
S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all specified.
S&F MCB single pole 5-40 Amps, 230V complete all as specified.
S&F MCB SPN 40Amps, 230V complete all as specified.
Surface and wall mounted LED tube light fitting, 20 W, batten type, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with all accessories , suitable for operation on AC, single phase 220 / 230 Volts , 50 Hz supply, and including connecting up with PVC sheathed 1.0sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed. Make:- C&S (LTTB4F20WLED/W) /Crompton :- CCS-103-20-65-SL-DP-NWH / Havells :-LUMILINEPLUSSBS20WLED865SPCSS
Supply and fixing Surface and wall mounted LED tube light fitting ,2 feet, 10 watt 220 V AC decorative, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with all accessories , suitable for operation on AC, single phase 220 / 230 Volts , 50 Hz supply, and including connecting up with PVC sheathed 1.0sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and as directed. Make:- C&S (LTTB2F10WLED/W) Crompton :- CCS-103-10-65-SL-DP-NWH / Havells :-LUMILINEPLUSSBS10WLED865SPCSS
Supply and fix Decorative ECO bulkhead luminaire capacity 10W, extruded aluminium housing with polycarbonate diffuser ,environmental friendly ultra modern energy saving surface mounted, LED luminaire comprising of high brightness and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete all as specified. Make:- C&S (LTB10WLED) /Crompton :- LBHP-10-CDL / Surya :-SLE BH 10W
S&F LED building security light fitting 25W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to Bldg etc complete all as specified and as directed. Make:- C&S (LTESSI25WLED) /Bajaj :- BCLST 25W LED I V2 /Crompton :- LSTS-25-CDL-M
S&F MCB DB SPN 8 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
S&F MCB DB SPN 4 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
Exhaust fan, heavy duty, 300mm sweep, 1400 RPM, with louvers, metal body conforming to IS-2312-1967, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing and fixing arrangements like making hole in wall and finishing to shape to match adjoining surface complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on wall/ ceiling / roof trusses etc. and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories all as specified and as directed.
Supply and fix decoractive LED POST TOP Lantern light fitting 20W with robust and reliable LED post top light with transparent diffuser,soft & comfortable uniform light distribution complete with all fitting accessories , suitable for operation on AC, single phase 220 / 230 Volts , 50 Hz supply complete all as specified. Make :- C&S :- CETUS/20W (LTGLC20WHPLED/W)/Havells:- RUBYPT25WLED830SSYMTOPC /Bajaj :- BGCTN 25W LEDWW
Supply and fix Flood light luminaries LED energy saving 50 Watt, LED exlusive innovative designed, long life versatile pressure die-cast aluminium IP 65 flood light with high pressure die cast aluminium housing and impact resistant polycarbonate lens complete with all accessories and glass cover with suitable bracket or with grouted spring pressure fasterner/steel rawal plugs as directed by Engineer in Charge including connection from juction box to lilght fittings with 1.5 Sqmm 2 single core PVC insulated and unsheather, multi stranded FRLS copper conductor cable drawn in flexible conduit complete all specified and directed by the Engineer-in-Charge. Make :- Havells :- JETA QUANTOPLUSFLP50WLED757SYMLENS /Crompton :-LFL-50-CDL/60-M / Bajaj :-BJFL 50W LED I
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and as directed.
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Supply and laid in tranches/floors or fixed on wall for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core with fixing materials like lugs,cable glands etc complete including taking down old unserviceable cable with accessories complete all as specified and directed.
Supply and laid in tranches/floors or fixed on wall for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core with fixing materials like lugs,cable glands etc complete all as specified and directed.
Supply and fix 3 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 10 KA adjustable thermal and fixed magnetic setting with sheet metal enclosuer suitable fixing frame complete all as specified.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cable for cushioning of cable complete all as specified.
Supply and laying for sub class ‘B’ bricks , laid flat and dry perpendicular to the direction of cable adjacent to each other ,in trench over the cable for protection complete all as specified.
M&L for GI tubing light grade laid in trenches, in floors, on wall and road crossing for cable protection fof size 40 mm dia complete all as specified and directed.
Supply and laying of CPVC pipes of sizes 25mm bore (inner dia), grade SDR 13.5 (Class 2) with ISI mark including all fitting and fixture like coupler, Male adapter, plastic threaded, Reducing Male adapter plastic threaded, Union, Female Adapter plastic threaded etc laid in excavated trenches etc all as specified and as directed.
Supply and fixing in replacement of CPVC Ball valvewith brass threaded of sizes 25mm bore (inner dia), grade SDR 13.5 (Class 2) with ISI mark all as specified as directed.
Cutting existing steel tubing for alterations or additions (Each cut measured) all as specified and as directed.
M/s Omm Muruga Enterprises
SAMYDOSS CONSTRUCTIONS
D Subramani and Sons
Jai Sudha & Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .