| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | ₹20.0 L Quoted ₹20.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.0 L+₹1.4 L (6.58%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | ₹22.0 L+₹1.4 L (6.58%) | L2 | Rejected-AOC L2 |
| 3 | L3₹29.2 L+₹8.6 L (41.7%)Rejected-AOC | ₹29.2 L+₹8.6 L (41.7%) | L3 | Rejected-AOC L3 |
| 4 | L4₹30.2 L+₹9.6 L (46.5%)Rejected-AOC 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | ₹30.2 L+₹9.6 L (46.5%) | L4 | Rejected-AOC L4 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
16 Oct 2024, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION SYSTEM, LT PANEL BOARDS, UG CABLE, LT SWITCHGEAR, APFC PANELS AND CONNECTED ALLIED WORKS AT AFS CAW UNDER GE (AF) HAKIMPET
2024_MES_675122_1
8704/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CAW
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Hakimpet
₹66,000
Yes
16 Dec 2024
18 Sept 2024
18 Oct 2024
18 Sept 2024
16 Oct 2024
2 Oct 2024
Amount
NOTES:- 1. The contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safely measures are to be adopted by contractor on site. 3. The contractor shall provide and deploy sufficient electrician (as approved by GE / Engineer in charge) shall report at 9:00 hrs to JE E/M / Engineer in Charge to collect the complaints job card in working days and complete the same completed within 24 Hrs. 4. The complaints shall be rectified within 24 Hrs if the complaints is/are not attended / not completed within 24 Hrs (Except repair/replacement of major items) recovery will be done at Rs 500 per complaint per day. 5. For major parts like replacement of MCB, DBs, MCCBs etc should be rectified within 3 working days, if the contractor not rectify within time then recovery will be done at Rs 1000 per complaint per day. 6. After completion of job work complaint, the contractor has to produce job card duly signed by user & JE / Engineer in Charge. 7. If contractor failed to provide their electrician to attend the complains then recovery will be done at Rs 1000 per day. 8. The contractor should procure minimum 50% of the materials for all items as per BOQ (Other than paints) mentioned in this CA, within 20 days after getting sample approval and kept in safe custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of work. If contractor fail to complete the work within contract due to lack of fittings a penalty of 20% shall be applicable on quoted rates by the contractor. 9. In repair works, rate quoted for demolition /dismantling /taking down is deemed to be inclusive of removing the same from site and station. 10. In maintenance works, the contractor should maintain separate registers for repair works. Day to day complaints should be noted in those registers with SI nos of complaints, location qty of work, status of complaints and signature of in charge and stamp of the office. Formal will be given from concern AGE office. The contractor should obtain the signature of in charge on the same day of work. These register to be submitted to JE (E/M) on every weekend without fail. 11. The contracts involving working at elevated locations of buildings, contractor should ensure proper safety arrangements as per norms. Wearing safety belts and helmets are mandatory. A penalty of Rs 1000 per day will be recovered from contractor if safety norms are not followed. 12. The plumbing complaints resulting wastage of water should be rectified within 12 working hours and if contractor fail to fulfill this, a recovery of 10% of rate quoted for relevant item will be charged from contractor in this regard. 13. After completion of work, no stores/debris/ loose items be kept at work site or dumped inside station . Entire area to be cleared and waste material be taken outside from the station .
Taking down copper / aluminum point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc, including paint tuch up to match with the existing surface as per site requirement, complete all as specified and directed.
M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn thorough and including non metalic, med. grade rigid PVC conduit with all conduit accessories and including provisoin of 1.5 sq mm PVC indulated copper cable FRLS as earth continiuty conductor, fabricated steel teminal box made of MS sheet and cover & base frame sheet for fixing switches, socket outlets, fan regulators etc, all as specified and directed.
One light point controlled by one way switch.
One light point controlled by two way switch.
One ceiling fan/ exhaut fan point controlled by one one way switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on the Independent board.
One bell/ buzzer point controlled by one push button n the same board with other switches or independent.
All as per item No. 2 here-in-before but conductor drawn through stove enamelled 20 mm dia medium grade steel conduit for one light point controlled by one flame proof switch, complete all as specified and directed.
All as per item No. 2 here-in-before but with 4 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor, complete all as specified and directed.
M&L for Point wiring complete with 1.5 Sqmm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn thorough and including double locking type PVC casing and caping and its accessories of suitable size and including provisoin of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated steel teminal box made out of MS sheet and cover sheet for fixing the switches /sockets/ regulators etc, all as specified and directed.
One light point controlled by one way switch
One light point controlled by two way switch
One ceiling fan/ exhaut fan point controlled by one way switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on the Independent board.
One bell/ buzzer point controlled by one push button on the same board with other switches or independent.
All as per item No. 5 here-in-before but with 4 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor, complete all as specified and directed.
S&F Switch piano flush type, single pole one way 6 Amps 240 volts, complete all as specified and directed.
Supply and fix Switch Piano flush type two way 6 Amps, complete all as specified and directed.
Supply and socket piano flush type Socket outlet 2 in 1, 3 pin, 6A complete all as specified and directed
Supply and fix Switch socket combination 2 in 1, 5 Pin, 6 Amps flush type, complete all as specified and directed.
Supply and fix Switch socket combination, 3 pin, 6 and 16A, 5 in 1 flush type, complete all as specified and directed.
Supply and fix Switch bell push 6 Amps flush type, complete all as specified and directed.
S&F Stepped type electronic fan regulator flush type, complete all as specified and directed.
Supply and fix Modular switch 6A, 1 way, complete all as specified and directed.
Supply and fix Modular switch 16A, 1 way, complete all as specified and directed.
Supply and fix Socket outlet, 5 pin, 6A modular, complete all as specified and directed.
Supply and fixing Modular Socket outlet, 6/16A modular, complete all as directed.
Supply and fixing switch bell push modular, complete all as directed.
Supply and fixing Fan regulator, 2 modular, complete all as directed.
Supply and Fixing bell Ding Dong AC, 230 Volts, SP, complete all as specified and directed.
Supply and replacement in repairs, Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V.
Supply and fixing in repair LED light fitting 2 x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with and LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
Suppy and fix in repairs, wall mounted 1 x 10 W LED 220V, AC, 2' batten type with extruded Al, heat sink, integral driver, energy efficient, ready to use pack etc, complete with all accessories internally pre-wired and fixing the same on and including two Nos. PVC blocks and connecting up with twin core twisted flexile copper conductor cable of suitable size upto ceiling rose including taking down old one.
Suppy and fix in repairs, wall mounted 1x 20W LED 220V, AC, 4' batten type, with extruded Al, heat sink, integral driver, energy efficient, ready to use pack etc., complete with all accessories internally pre-wired and fixing the same on and including two Nos. PVC blocks and connecting up with twin core twisted flexile copper conductor cable of suitable size upto ceiling rose including taking down old one.
Taking down the old unserviceable recess mounted fitting of any type, supply and fix, new ultra modern architectural 2'x2', recess mounted, 36W LED light fittingwhich provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling. including modification of the false ceiling as required, complete all as specified and directed.
Taking down the old unserviceable recess mounted fitting of any type, supply and fix, Square/round recess mounted 15 W LED light fitting, with high quality aluminium die cast body, high efficient constant current LED driver, including modification of the false ceiling as required at site, complete all as specified and directed.
Supply and replacement of retrofit LED tube light, cool white, 18/20 watt, suitable for T8/T12 frame, 2000 lumens, including modification of wiring to suit LED tube and taking down old one, complete all as specified and directed.
Taking down of unserviceable building security lights of any type, Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.complete all as specified and directed.
Taking down unserviceable sub main wiring of any description and M&L for sub main wiring with 3x1.5 Sqmm, (Ph+E+N) , FRLS PVC insulated, unsheathed, multi stranded,1100 volts grade copper conductor cable , single core, drawn through and including rigid PVC conduit of suitable size with all conduit accessories complete all as specified and directed. Note: Three runs (P+N+E) of 1.5 Sqmm copper cable and one run of 20 mm dia, rigid PVC conduit with all conduit accessories shall be measured as one unit length.
Description all as per item here-in-before but with 3x2.5 Sqmm, complete all as specified and directed. Note: Three runs (P+N+E) of 2.5 Sqmm copper cable and one run of 20 mm dia, rigid PVC conduit with all conduit accessories shall be measured as one unit length.
Description all as per item here-in-before but with 3x4.0 Sqmm, complete all as specified and directed. Note: Three runs (P+N+E) of 4.0 Sqmm copper cable and one run of 20 mm dia, rigid PVC conduit with all conduit accessories shall be measured as one unit length.
Description all as per item here-in-before but with 3x6.0 Sqmm, complete all as specified and directed. Note: Three runs (P+N+E) of 6.0 Sq mm copper cable and one run of 25 mm dia, non metallic, med. gr. rigid PVC conduit with all conduit accessories shall be measured as one unit length.
Description all as per item here-in-before but with 4x6.0 Sqmm (3Ph+1N) + 1x6.0 Sqmm (Earth), complete all as specified and directed. Note: five runs of 6.0 Sqmm copper cable and one run of 25 mm dia, rigid PVC conduit with all conduit accessories shall be measured as one unit length.
Description all as per item here-in-before but with 4x10.0 Sqmm (3Ph+1N) + 1x10.0 Sqmm (Earth), complete all as specified and directed. Note: Six runs of 10.0 Sqmm copper cable and one run of 32 mm dia, rigid PVC conduit with all conduit accessories shall be measured as one unit length.
Taking down unserviceable sub main wiring of any description and M&L for sub main wiring with 3 runs of 4.0 Sqmm, FRLS PVC insulated, unsheathed, multi-stranded, 1100 Volts grade copper conductor calbe, single core, drawn through and including double locked type PVC casing & Capping and its all accessories of suitable size on wall/ roof surfaces, complete all as specified and directed. Note: Three runs 4.0 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.
Desrciption all as per item here-in-before but with 3x6.0 Sqmm, complete all as specified and directed. Note: Three runs 6.0 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.
Desrciption all as per item here-in-before but with 4x10.0 Sqmm (3Ph+1N) + 1x 10.0 Sqmm (Earth), complete all as specified and directed. Note: Six runs 10.0 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.
Supply and fix in repairs including taking down the following unserviceable Items:-
(a) Lamp holder PVC/ Polycarbonate type with back plate suitable for batten/ angular type.
(b) Ceiling rose PVC/ Polycorbonate insulated body with three terminals.
(c) Switch Piano, Flush type single pole, one way 6 Amps
(d) Switch Pian flush type two way 6 Amps
(e) Socket outlet 2 in 1, 3 pin, 6A
(f) Switch Socket Combination 2 in 1, 5 Amps flush type
(g) Switch Socket combination 3 Pin, 5 and 15 Amps 5 in 1 flush type
(h) Switch Bell push 5 Amps flush type
(j) Stepped type electronic fan regulator flush type
(k) Modular Switch 6A 1 Way
(l) Modular Switch 16 A 1 Way
(m) Socket outlet 6 A Modular
(n) Socket outlet 16 A modular
(o) Switch Bell push modular
(p) Fan Step regulator modular
(q) Bell Ding Dong AC 230 Volts
(r) Lamp Pin type 9 Watt
(s) Surface mounting PVC/Poly carbonate Box of 6 Amps Socket with switch
(t) Surface mounting PVC/Poly carbonate Box combined 2 hole for 6/16 Amps Socket with Switch
(u) Plug top polycarbonate 3 Pin 5 Amps
(v) Plug top Polycarbonate 3 Pin 15 Amps
M&L for Taking down ceiling fan of any description, sealing cable ends, dismantling blades, cleaning all dust, applying grease, filling cavaties with fillet, including reassembling blades and hanging ceiling fan after getting repaired and connecting up including provision of cable from ceiling rose to connector of fan, complete all as specified and directed.
All as per item here-in-before but exhaust fans of any sweep.
All as per item here-in-before but wall mounted fans/ Pedestal fans of any sweep.
Disconnect and remove unserviceable capacitor and Supply and fix capacitor 2.5 MFD suitable for ceiling fan / exhaust fan, complete all as specified and directed.
All as per item above but of 4 MFD suitable for ceiling fan / exhaust fan, complete all as specified and directed.
Dismantle the unserviceable shackle assembly and supply and fixing new shackle assembly comprising GI bolts, nuts, rubber bush and split pin, complete all as specified and directed.
M&L for removing the defective fan winding and rewinding with super enamelled copper wire of existing gauge, applying insulation varnish, pre heating and binding with empire tubes, crimple sheet etc. as required for rewinding, complete all as specified and directed for the following:-
Ceiling fan of size upto 1400 mm sweep.
Wall mounted/ Pedestal fan of size upto 450 mm sweep.
Exhaust fan of size upto 300 mm Sweep.
Exhaust fan of size 350 to 450mm Sweep.
Disconnect and remove unsv PCB and supply and fix PCB suitable for BLDC Fan of 1200mm sweep of any make or model, complete all as specified and directed
M&L for remove unsv bearing and supply and fix bearing suitable for fan of 1200mm sweep of any make or model, complete all as specified and directed
Taking down unserviceable louvers and supply and fix new louvers suitable for exhaust fans of size upto 450 mm sweep, complete all as specified and directed.
Taking down the electric Geyser of capacity 25 ltrs/ 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, electrical connections,taking out the inner leaking copper tank, brazing the leaking portion of copper tank, testing for leaks, re-assembling the geyser including provision of additional glasswool as required, refixing in position, testing and reconnecting the inlet/ outlet water pipes and testing on completion, complete all as specified and directed.
Supply and fixing of following items in repairs, suitable for single phase, 230 Volts, 50 Hz for existing type electric Geyser of capacity 25/50 Litres incl taking down the old one :-
(a) Heating element 1500/2000 watts push/ thread type porcelain / Circular / triangular type as required at site.
(b) Thermostat as per the existing type.
(c) Indication lamp red/ green.
(d) Fusible plug
Taking down unserviceable PVC connection of any description and supply and fix new PVC connection 15mm dia 450mm long with brass nuts, and rubber washers on both sides suitable for cold/ hot water, complete all as specified and directed.
Taking down unserviceable PVC connection of any description and supply and fix new PVC connection 15mm dia 600mm long with brass nuts, and rubber washers on both sides suitable for cold/ hot water, complete all as specified and directed.
Taking down old UNSV DB and Supply and fixing Vertical distribution board for incoming MCCB upto 250 A and MCBs for outgoing to be used, VTPN 8 Way, 415 Volts having earth bar & neutral link double door as in repairs complete all as specified and directed. Note. MCCB and MCB will be measured and paid seperately under relevant items. Make Havells, HPL, Indo Asian, Standard, Legrand.
Taking down old UNSV DB and Supply and fixing Vertical distribution board for incoming MCCB upto 250 A and MCBs for outgoing to be used, VTPN 4 Way, 415 Volts having earth bar & neutral link double door as in repairs complete all as specified and directed. Note. MCCB and MCB will be measured and paid seperately under relevant items. Make Havells, HPL, Indo Asian, Standard, Legrand
Taking down old UNSV DB and Supply and fix in repair, MCB distribution board, double door type, TPN 4 way, sheet steel powder painted, with bus bar, neutral link & earth bar etc, including taking down existing DB complete all as specified and directed.
Taking down old UNSV DB & Supply and fix in repair, flush to wall, MCB distribution board, double door type, SPN 12 way, sheet steel powder painted, with bus bar, neutral link & earth bar etc, incl taking down existing DB complete all as specified and directed.
Taking down old UNSV DB & Supply and fix in repair, flush to wall, MCB distribution board, double door type, SPN 8 way, sheet steel powder painted, with bus bar, neutral link & earth bar etc, including taking down existing DB complete all as specified and directed.
Taking down old UNSV DB & Supply and fix in repair, flush to wall, MCB distribution board, double door type, SPN 4 way, sheet steel powder painted, with bus bar, neutral link & earth bar etc, including taking down existing DB complete all as specified and directed.
Taking down old UNSV Metal Clad enclosure & Supply and fix Single Pole & Neutral Metal clad enclosure with a two pin and earth plug and socket including one single pole MCB of 20 Amps in repair complete all as specified and as directed by Engineer-in-Charge
Taking down old UNSV MCCB & Supply & fix in repairs, MCCB 3 pole, 415V, Adjustable /fixed type, follwing size suitable for load line DBs with terminating cables by using lugs as required, complete all as specified and directed.
MCCB TP 160A, 36KA. Adjustable type
MCCB TP 125A, 16KA. fixed type
MCCB 3 Pole 25A to 100A, 16KA. fixed type
Taking down old UNSV MCB & Supply and Fix in repairs, MCB FP/ TPN, DP/ SPN, SP ''C'' curve, 415V, including provision of copper lugs for cable termination, terminating cables by using lugs as required, complete all as specified and directed.
MCB TPN/FP 16 to 32 Amp
MCB TP 25 To 63 AMP
MCB SPN 32 AMP
MCB SPN 40 to 63 AMP
MCB SP 5 To 32 AMP
MCB FP 40 to 100 AMP
Taking down exisiting service cable and supply and fixing 1100 volts grade, heavy duty cable, PVC insulated, stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable of size 4.0 Sqmm, complete all as specified and directed.
Taking down exisiting service cable and supply and fixing 1100 volts gr. heavy duty cable, PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable of size 6.0 Sqmm, complete all as specified and directed.
Taking down exisiting service cable and supply and fixing, 1100 volts gr. heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable of size 10 Sqmm, complete all as specified and directed.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to wall or any other indicated situation for loop earthing etc. as required 4.0mm dia galvanised iron or steel wire, complete all as specified and directed.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover Single phase, 230 V, 10 to 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete including taking down old unsv electric meter complete all as specified and directed. Make: HPL Model:SPPB1321120000ME03 (Gurgaon) 'OR' equivalent in Secure/ L&T / AE.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 3 Phase, 415 volt, 10 to 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete including taking down old unsv electric meter complete all as specified and directed. Make: HPL, Model:TPPB1521130000ME01 (Gurgaon) 'OR' equivalent in Secure/ L&T / AE.
Supply and replacing of TP, 3x240V, 50Hz, CT operated, digital Multi-function Energy meters of accuracy class 0.5 with backlit LCD display. Measures and displays trivector energy, load survey, TOD, Tamper detection & logging, power on / off events, instantaneous parameters of rating -/5A with transperant hinged type box, including taking down the old, complete all as specified and directed. Make: L&T 'OR' equivalent in Secure/ HPL/ AE.
Taking down unserviceable Fire Alarm control panel and Supply, Installation, Testing and commissioning of New Addressable Fire Alarm control panel with power supply & battery back up at normal condition and 15 minutes alarm operation with battery charger etc. 2 Zone panel, complete all as specified and directed. Make: EST-3/Notifire/ Honey well/ Ravel
Taking down unserviceable multi-sensor (smoke & heat) and Analog addressable type multi-sensor (smoke & heat) detector with dual optic's technology to distinguish and differenciate between real fire, steam and dust to avoid any false alarm & built-in isolator with multiple algorithms setting with base powder, including other accessories as required, complete all as specified and directed. Make: EST-3/Notifire/ Honey well/ Ravel
Servicing the Analog / Addressable type multi sensor fire alarm system by removing the faulty detectors, cleaning all the detector, ensuring the power supply and battery back up to the panel, minor repair to the power cord and cable, clearing all the faults, detected by the system and bring it to normal mode complete all as specified and directed by Engineer in Charge. Note. Replacement of detectors and battery will be measured and paid separately.
Taking down unserviceable battery from the Fire Alarm control Panel and Supply and fixing new Battery of 12 Volt DC lead acid battery 7 AH complete all as specified and directed by Engineer in charge.
Servicing of solar geyser panel using mild cleaning agent, removing and replacing of rusted nuts and bolts with GI nuts and bolts, complete all as specified and directed.
Repairs of copper tube with dia 8 to 10mm from inlet/ outlet of Solar Panel by cutting the worn out portion and replace with new copper tube of suitable dia upto 3mtr by welding/ turning/ fusing and matching with existing, complete all as specified and directed.
Supply and replacement of geysor element, 3.0 KW, SP, suitable for Solar water heater backup including taking down the old element, complete all as specified and directed.
Supply and replacement of geysor element, 2.0 KW, SP, suitable for Solar water heater backup. including taking down the old element, complete all as specified and directed.
Disconnecting the electrical, water supply connections of Solar geyser, repairs to leaking Solar geyser inner tank by removing glass wool, cutting/disconnecting the rusted inlet and outlet nipples, supply and connect new nipples of size as existing by brazing/ welding, leak testing, refilling the glass wool including additional glasswool as required, fixing in position, testing and commissioning, complete all as specified and directed.
Disconnecting the electrical, water supply connections of Solar geyser, Supply and replacement of Solar geyser storage water tank of capacity 100litres, made of EN 304 SS steel sheet of thickness 0.8mm, suitable for flat plate collector along with with stand, complete all as specified and directed.
Supply and fixing Heavy duty Battery 12 V, not less than 150 AH, having polypropylene container with ribs, recharging capability (suitable for DG set/solar liights), complete all as specified and directed. Make: EXIDE / AMARON
Supply and fixing Heavy duty Battery 12 V, not less than 88 AH, having polypropylene container with ribs, recharging capability (suitable for DG set/solar liights), complete all as specified and directed. Make: EXIDE / AMARON
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
Supply and Fix , bed side night lamp, adjustable arm decorative type as per existing model fixed on wall complete on PVC base blocks and connecting with suitable size of flexible cable from connector all as specified and directed by Engineer-in-charge. Make : Philips/Halonix/Bajaj
Supply and Fix in repair, booster pump cylender (pressure tank) threading type suitable for pressure pump of capacity 0.5 HP 220 volt AC or existing type, including testing all as directed by Engineer-in-charge.
Supply and Fix in repair, booster pump Pressure switch threading type suitable for pressure pump of capacity 0.5 HP 220 volt AC or existing type, including testing all as directed by Engineer-in-charge. Model No. KP-35 Pressure switch of Danfoss or equivelent in ocean star/Amazor.
Rewinding of electrical motor(booster pump) by taking out burnt copper winding from stator, cleaning the casing & slots with wire brush & washing with water under pressure, cleaning with CTC, dried and rewinding the motor using same gauge of insulated copper wire as existing & making the winding leak proof by applying warnish, drying etc. and re-connecting at its original position of capacity of motor upto 0.5 HP including testing of motor after installation for satisfactory functioning/running all as specified and as directed by the Engineer-in-charge.
PVC insulated Tape 20 mm width, 25 m length, assorted colour Make: Grippex or equivalent as approved.
Dismantling damaged PCC poles / steel tubular poles/struts of any size complete and supply & erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) including painting of poles with two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and black bituminous paint on embedded portion complete all as specified and directed.
M&L for painting the external exposed surfaces of steel tubular sewaged/ rail pole of 9/11 mtrs long alongwith cross arm, brackets and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and pasting radium red stickers / paint with 3 line around the pole and numbering of pole with synthetic enamel white paint on black base complete all as specified and directed
Excavation in trenches not exceeding 1.5 m in wide and not exceeding 1.5m in depth for laying of cables / stay assembly / pipe lines and getting out in the following types of soil complete all as specified and as directed.
(a) Soft / loose soil
Excavation in trenches in hard/ dense soil not exceeding 1.5 m in wide and exceeding 1.5m in depth for laying of cables / stay assembly / pipe lines and getting out complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
Supply and spreading clean, fine, dry river sand in trenches for cushioning of under ground cable / inside transformer yard complete all as specified and directed by Engineer-in-Charge. Note: Only punned thickness shall be measured for payment purpose.
Supply and lay common burnt clay building bricks sub class 'B' of designation 75 laid in trenches as protection to cables complete all as specified and as directed.
M & L for Road cutting / hard standing for taking up or laying of LT UG cable upto a depth of 15 cm, after laying of cable, well ramming to the excavated soil and repair the exvcavated portion of road as existing or by providing suitable mixture of PCC all as specified and as directed.
Supply and fixed in repairs Danger Notice board of 1.6 mm thick mild steel sheet vitreous enamelled white with letter, figures and conventional skull and bones in a single Red colour anf fixed with MS Clamp ,bolts and nuts of approved size for LT 20 cm X 15 cm Size complete all as specified and as directed.
Taking down unsv GI tubing and M&L for new galvanized steel tubing, light grade, with all fittings for protection of cable complete all as specified and as directed of the following sizes :-
(a) 100mm bore.
(b) 80mm bore
(c) 50mm bore
(d) 40 mm bore
M&L Locating and pin point electric Fault precisely on LT UG cable Under Ground Cable ( 1.1 KV ) Fault, Locating System which is the most Advanced system in power cable fault detection combining the best-in market technologies in to a single fully automatic centralized setup with high reliabiliy and Multi-level safty standards
LTUG cable 2core x 10Sqmm to 4core x 16sqmm
LTUG cable 3.5core x 25Sqmm to 3.5core x 50sqmm
LTUG cable 3.5core x 70sqmm to 3.5core x 300Sqmm
Cutting and removing the damaged portion of the LT cable, supply, prepare and connect cable jointing kit for 1.1KV grade cable for heat shrink type straight through joint complete with jointing material and accessories suitable for XLPE, armoured aluminium conductor cable of size upto 4x16 Sqmm complete all as specified and as directed. Note: Earth work will measured and paid seperately under relevant items.
All as per item here-in-before but for cable of size 3.5/4 x 25mm² to 3.5x70mm².
All as per item here-in-before but for cable of size 3.5 x 95 mm² to 3.5x300mm².
Supply &Laying LT UG Cables , XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, of following cross-sectional area complete all as specified and as directed.
(a) 10Sqmm, 2 Core
(b) 16Sqmm, 4 Core
(c) 35Sqmm, 4 Core
(d) 50 Sqmm, 3.5 Core
(e) 70 Sqmm, 3.5 Core
(f) 95 Sqmm, 3.5 Core
(g) 120 Sqmm, 3.5 core
(g) 150 Sqmm, 3.5 core
(g) 185 Sqmm, 3.5 core
(g) 300 Sqmm, 3.5 core
Taking out unserviceble Earthing from Sub stns , M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including 32x6 mm galvanized iron strip as earth lead, extended upto 7.5 m 'or' upto test terminal point, drawn through 40mm dia light grade GI pipe for protection of galvanized iron strip in the ground, further connecting with suitable size of earth strip to LT Panel, Transformer, DBs etc., including excavation, earth work, magnesium sulphate-50 Kg and charcoal in alternate layers on all sides sorrounding the earth plate, bentonite-25 Kg clay mixed with water and loomy soil sorrounding the plate on all sides, all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, wire net, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt-I, including breaking and removing the old unsv earth materials complete all as specified and as directed. Note :- Excvation earth work and GI strip upto 7.5 mtr incl in the job.
Taking down change over switch and S&F new onload change over switch with sheet metal enclosure of capacity 200 Amps, TPN, 415 volts, 50 Hz, AC of the following sizes complete all as specified and as directed. Make: L&T / Siemens / Havells / CG.
Taking down MCCBs of any description from the panel board and S&F new thermal adjustable MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity 200 Amps with breaking capacity 36 KA complete all as specified and as directed. Make: Havells/Siemens / L&T / Schneider / GE Controls.
Taking down MCCBs of any description from the panel board and S&F new thermal adjustable MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity 250 Amps, breaking capacity 36 KA complete all as specified and as directed. Make: Havells/Siemens/L&T/Schneider/GE Controls.
Taking down MCCBs of any description form the panel board and S&F new MCCBs, 3 pole, 415 volts, of existing type and model suitable for panel mounting of capacity 320 Amps, breaking capacity 36 KA complete all as specified and as directed. Make: Havells/Siemens / L&T / Schneider / GE Controls.
Taking down MCCBs of any description form the panel board and S&F new MCCBs, 4 pole, 415 volts, of existing type and model suitable for panel mounting of capacity 400 Amps, breaking capacity 36 KA complete all as specified and as directed. Make: Havells/Siemens / L&T / Schneider / GE Controls.
Taking down MCCBs of any description form the panel board and S&F new MCCBs, 4 pole, 415 volts, of existing type and model suitable for panel mounting of capacity 630 Amps, breaking capacity 50 KA complete all as specified and as directed. Make: Havells/Siemens / L&T / Schneider / GE Controls.
M&L for PCC 1:3:6, type C-2 mix using 40 mm graded stone aggregate as in filling and mass concrete foundation to pole etc., including breaking and removing the old concrete and necessary form work complete all as specified and as directed.
M&L for PCC 1:2:4, type B-1 mix using 20 mm graded stone aggregate as in coping to poles etc including breaking and removing the old concrete and necessary form work complete all as specified and as directed.
M&L for GI earth Strip 32 mm x 6 mm layed in ground / fixed on walls including taking out unserviceable earth strip complete all as specified and as directed.
Rahul Enterprises (BID ID -3133968)
SRI LALITHA CONSTRUCTIONS (BID ID -3133546)
DPS sales and services india (BID ID -3133769)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .