Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC Accepted due to lowest | |
| 2 | L2₹29.4 L+₹7.5 L (33.9%)Rejected-Finance | L2 | Rejected-Finance Rejected due to not lowest | |
| 3 | L3₹32.5 L+₹10.5 L (47.6%)Rejected-Finance | L3 | Rejected-Finance Rejected due to not lowest |
Tender Value
₹27.7 L
EMD Value
₹55,340
Closing Date
9 Jun 2020, 6:00 pmClosed
COL NK SAH
CWE (AF) LOHEGAON PUNE
SPECIAL REPAIR WORK SERVICES FOR ROOF OF THE HANGAR AT COO SECTION AT MUMBAI UNDER GE AF THANE
2020_MES_333444_1
82583/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF THANE
As per NIT and tender documents
5 documents required · 5 mandatory
₹500
GE (AF) thane
₹55,340
Yes
1 Sept 2020
12 Mar 2020
12 Jun 2020
12 Mar 2020
9 Jun 2020
26 May 2020
Amount
Dismantling plain or corrugated steel sheeting,any gauge,thickness, including Nainital or similar pattern roof covering in any position including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of two colour having tensile strength of 550 Mpa ( red colour @ 50% and white colour @ 50% ) as in roof covering/cladding to wall bent to curve any radius , fixed with self tapping scews including necessary steel double scaffoldingcomplete all as specified and as directed by engineer in charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
S& F mild steel Fe-410-W(Gde-E-250)quality-B, Joist, channel,angle,or tee sections, fixed independently,connecting plates, etc,(cut to ordinary lengths I.e.within 20mm of the length indicated), ornamental and intricate design including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, Fe 410-W (Gde-E-250) quality-B,etc , ornamental and instricate design , including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
S & F 6 mm thick plain transparent polycarbonate sheets (double layered of desired colour and shade ) bent to shape required as in cladding/ roof over steel framed sections including screwing etc. including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
S & F 6 mm thick plain non transparent polycarbonate sheets (double layered of desired colour and shade ) bent to shape required as in cladding/ roof over steel framed sections including screwing etc. including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
M & L for providing, cement concrete type B0 , 1:2:4 (12.50 mm graded aggregate) mixed with water proofing compound @ 3% by weight of cement in roof kerbs or mud stops, rounded or camferedon edges and similar works including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
M&L for preparartion of new surfaces of steel exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
M&L for preparartion of old surfaces of steel exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
M&L for preparartion of old surfaces of steel not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
Taking down cement plaster of any description on brick walls etc including raking out joints, hacking for key, scrubbing down with water including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
M&L for 10 mm thick cement plaster finished even & fair on Brick or concrete surfaces in CM ( 1:6 ) including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
M&L 3mm thick wall care putty on wall including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
M & L for preparation of new surfaces on walls and applying two coats of oil bound distemper over a coat of primer including necessary steel double scaffolding complete all as specified and as directed by engineer in charge.
M&L for 15 mm thick cement plaster on brick or concrete surfaces in CM ( 1:4 ) mixed with water proofing compound @ 3% by weight of cement including steel double scaffolding complete all as specified and as directed by engineer in charge. Note :- WPC shall be measured and paid separately
M & L for preparation of new surfaces on walls and applying two coats of external weather coat emulsion paint over a coat of primer of approved make and shade all as per manufacturer's instructions and directions including steel double scaffolding complete all as specified and as directed by engineer in charge.
M&L for complete removal of existing treatment and appying 3mm thick wall care putty .Thereafter applying two coats of oil bound distemper over a coat of primer including steel double scaffolding complete all as speciofied and as directed.complete all as specified and as directed by engineer in charge.
M & L for preparing old plaster surfaces of wall including washing, rubbing down and stopping of painted surfaces , chajjas in any position and applying two coats of external weather coat emulsion paint over a coat of primer of approved make and shade all as per manufacturer's instructions and directions including necessary steel scaffolding complete all as specified and as directed by engineer in charge.
Supply only water proofing compund complete all as specified and as directed by engineer in charge.
Removing of vegetation / plantation on the wall of building including necessary steel double scaffolding and roots, superficial area not exceeding 2 sqm each and making good of surface by applying chemical treatment with GLYPHOSATE 41% complete all as specified and as directed by engineer in charge.
Cutting opening through brick walls for door , window and other opening or enlarging existing openings, converting window into door opening etc or cutting out defective brick work for under-pinning , including providing , fixing and removing shoring , cleaning and stacking bricks removing surplus serviceable bricks, from site and rubbish outside MOD land complete all as specified and as directed by engineer in charge.
Forming jambs etc to opening ( forgoing item ) including cutting toothing and properly bonding into old work also facing jointing and pointing to match existing work complete new work built in cement mortar ( 1:4 ) complete all as specified and as directed by engineer in charge.
Making good under cills or over arches, lintels and bressummers including all pinning when necessary complete all as specified and as directed by engineer in charge.
Rendering 10 mm thick in CM (1:4) as in backing coat to receive slab complete all as specified and as directed by engineer in charge.
M& L for fixing of 20mm thick cudappa stone slab in opening of ventilators ( Jambs, cills and soffit of lintels) complete all as specified and as directed by engineer in charge.
M & L for Anodised aluminium frame (powder coated )(minimum thickness of power coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by engineer in charge.
M & L for 4 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and as directed by engineer in charge.
Vinod Enterprises
Atharva Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .