Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC VILL NUTAN PALLY AMMUNITION ROAD PO PS BUD BUD DIST BURDWAN PIN 713403 WB | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹34.5 L+₹62,900 (1.86%)Rejected-Finance MONIRAMPUR DASPARA P O BARRACKPORE | BARRACKPORE | NORTH 24 PARGANAS | WEST BENGAL | 743101 | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹34.8 L+₹1.0 L (3.00%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted | |
| 4 | Rejected-Technical | - | Rejected-Technical Doesnt mee the eligibility criteria |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_486040_2
8400-705/E8
Open Tender
Civil Works
Works
270 days
PANAGARH
Class D, Cat a (ii)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹80,000
Yes
15 Mar 2022
16 Dec 2021
13 Jan 2022
16 Dec 2021
11 Jan 2022
29 Dec 2021
60 days
Amount
Cleaning and desilting of sewge lines up 150mm dia any depth by pumping out/removing liquid waste/sewage, plugging the ends pipes or diverting the flow into drains if necessary, removing silt sludge etc, sprilinkling bleaching powder on the silt to avoid smell including all precautionery and saftey measures, such as saftey belts, ligthing arrangement face mask glouse etc and removing the same ( silt, sludge & other waste material) in leak proof trucks covered with tarpoline to out side of MD land all as per existing rules and regulation of civil authorities and flushing the sewagr lines with frsh water etc complete all as specified and directed by Engineer-in-charge
All as per item No 1.00 mentioned here-in- before but dia exceeding 150mm to 300mm complete all as specified and directed
All as per item No 1.00 mentioned here-in- before but dia exceeding 300mm to 600mm complete all as specified and directed
Attending day to day complaints for cleaning of localaised blokage from floor/nahni trap, soil, waste pipe, WC etc up to including Ist man hole and removing sludge/waste up to 50mtr distance and burning the same in pit complete all as specified
Clleaning and desilting of of manholes depth not exceeding 1.50 meter by pumping out/removing liquid wasteage and plugging the end sewer pipes or diverting the flow in to drains if necessary removing silt, sludge etc, sprinkiling bleaching powder on the silt to avoid bad smell including all precautionery and saftey arrangement such as face mask glouse etc and removing the same (silt, sludge & other waste material) in leak proof trucks covered with tarpoline to out side of MD land all as per existing rules and regulation of civil authorities and flushing the sewagr lines with fresh water etc complete all as specified and directed by Engineer-in-charge measures, such as saftey belts complete all as specified and directed.
All as per item No 5.00 mentioned here-in-above but depth of man hole exc 1.5m and n.exc 3.0m complete all as specified and directed.
M&L for cleaning of septic tank/soakage pit of any size, type and any depth and removing the sludge/solid content fom the septic tank/soakage pit by using honeysucker mechnical method including flushing with fresh water and make the sepic tank/soakage pit fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab complete all as specified and directed. For Sl item No, 1 to 7 above contractor shall adhere Note : 1 Minimum Four sweeper per day with T&P mechanical equipment shall be provided by the contractor on each working day for 8 hours per day for any type of blokage of swer lines with T&P / mechanical equipment (if required jet spray cleaning mechane mounted on truck with adequate pipe arrangement to reach the manhole away from the road as directed by Engineer-in-charge) shall be provided by the contractor on each working day other than Gaztted holiday, for 8 hours per day for any type of blockage incl sewer lines of any dia Note : 2. The contractor/superviser representative alongwith min four sweepers will report at 0900 hrs to the sub division for complaints and submit completion report at 1700 hrs everyday. And also sweeping/cleaning/brooming the office area and office toilets/bathroom as per instruction of concerned JE including required supporting item like broom, Phenyle etc arrange by Contractor.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for cesspits, manholes etc, and getting out in soft/loose soil even in foul position complete all as specified and directed.
All as per item No 8.00 mentioned here-in-above but in any type of soil mentioned here-in-above but depth 1.5 Mtrs but not exceeding 3.00 Mtrs complete all as specified and directed.
All as per item No 8.00 mentioned here-in-above but in hard/dense soil mentioned here-in-above but depth exc 3.0m but not exceeding 4.50 Mtrs complete all as specified and directed.
Returning, filling in and including spreading, leveling, watering & well ramming in layers n.exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing of excavated materials to a distance n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point in oft/loose soil complete all as specified.
Demolition of cement concrete (un- reinforced) not exceeding 15 cm thickness (above or below ground level) complete all as specified and directed.
Demolition of reinforced cement concrete as in cover slabs of manhole or septic tank, soak pit and walls , basement walls and in foundation complete all as specified and directed.
Demolition and breaking up drain pipes of internal dia 150mm (SGSW/PVC/RCC etc) set in cement mortar including bed concrete and removal of debris to low lying area of distance not exceeeding 150m complete all as directed by Engr-inCharge.
All as per Item No 15.00 mentioned here-in-above but internal dia of pipe 300mm complete all as directed by Engineer -in-Charge
All as per Item No 15.00 mentioned here-in-above but internal dia of pipe 450mm complete all as directed by Engineer -in-Charge
Supplying and laying UPVC Eco drain Hi-tech pipe drainage sewer system pipe bearing 160 mm dia minimum 4mm thick incluing jointing with coupler, bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. (Note:-Necessary PCC haunching/benching/ packing shall be measured and paid separately).
M&L for Reinforced concrete pipes, class NP2, dia 300mm laid and jointed complete with collars complete all as specified and directed.
M&L for Reinforced concrete pipes, class NP2, dia 450mm laid and jointed complete with collars complete all as specified and directed.
Supply and Laying 150mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars
M&L for Concrete bed to 150 mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in PCC 1:3:6 type C2 using 40mm graded stone aggregate all as specified and directed.
All as per item No 22.00 mentioned here-in above but internal dia of pipe 300 mm complete all as specified and directed.
All as per item No 22.00 mentioned here-in above but internal dia of pipe 450 mm complete all as specified and directed.
Demolition of brick work built in cement mortar for cracked wall of manholes, sepic tank, soak pit etc in foul position complete all as specified and directed.
M&L for brick work with fly ash bricks straight curved on plan exceeding 6 meter mean radius for manholes/septic tank/sok well etc/ in sewer works with old size bricks in Cement Mortar (1:4) complete all as specified and directed.
All as per item No 26.00 mentioned here-in- above but except Fly ash bricks complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete for bottom of manhole complete all as specified and directed.
M&L for Plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in surface channel aand drain complete all as specified and directed.
Taking down cement plaster from inside/outside of existing septic tank/manholes etc incl raking out joints, hecking for key scrubbing down with water and removal of rubbish off the premises complete all as specified and directed
M&L for 15mm thick rendering in cement mortar (1:4) inside and outside brick wall of manhole /seeptic tank /concrete surfaces even and smooth with out using extra cement complete all as specified and directed.
M&L for Setting coat of 3mm thick of CM (1:2), trowelled to even and smooth finish over rendering 15mm thick in CM 1:4 on fair faces of brick work finished surface even & smooth with using water proofing compound @ 2% complete all as specified and directed.
Supply only integral waterproofing compound
M&L for providing RCC precast cement concrete type B-0 (1:2:4) (using 12.5 mm graded stone aggregate) as in cover slab for manhole and similar article with plain face set in cement mortar (1:4) complete all as specified nd directed
S&F SFRC (Steel Fibre Reinforced Concrete) Manhole Cover with Frame, Shape round/square, (40 to 50 Kg approx ) set at the top of the manhole at site complete as per manufacturer instruction and as directed by Engineer-in-Charge.
M&L for mild steel TMT bar 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for column, hooking end binding with binding wire and including mild steel wire(annealed) not less than 0.9mm dia complete all as specified & directed by Engineer in Charge.
M&L for mild steel TMT bar 6mm to 8 mm dia, cut to length bent to shape required including cranking bending spirally for hooping for column, hooking end binding with binding wire and including mild steel wire(annealed) not less than 0.9mm dia complete all as specified & directed by Engineer in Charge.
M&L for type B-1 (1:2:4) (using 20 mm graded aggregate) providing RCC slab supported in wall beams and column and simillar works complete all as specified and directed.
Taking down rain water pipes (any size or pattern) , including all fittings and removal off the site complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall with clamps and jointed complete all as specified and as directed by EIC.
All as per item No 40.00 mentioned here-in-above but 75 mm bore complete all as speified and directed
S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and as directed by EIC.
All as per item No 42.00 mentioned here-in-above but with access door complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR), junction single, (single T), equal or unequal with access door complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR), junction double, (double T), equal or unequal with access door complete all as specified and directed.
S & F PVC (SWR) reducers of 110 mm bore complete all as specified and directed.
All as per item No 46.00 mentioned here-in-above but 75 mm bore complete all as specified and directed.
S&F 110 mm PVC (SWR) branch piece, single Y equal or unequal complete all as specified and directed
S&F, 75mm bore PVC (SWR) bends with rubber ring joints fixed to wall and jointed complete all as specified and as directed by EIC.
All as per item No 49.00 mentioned here-in-above but with acees door complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR), junction single, (single T), equal or unequal with access door complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR), junction double, (double T), equal or unequal with access door complete all as specified and directed.
S&F, 75mm bore PVC (SWR) branch pipe Y junction single equal or unequal with access door complete all as specified and as directed.
S&F 110mm bore PVC(SWR) vent Cowl complete all as specified and directd.
S&F 75mm bore PVC(SWR) vent Cowl complete all as specified and directd.
Dismantling floor hearth or wall tiling including cement mortar bedding, removing to low lying area and rubbish off the premises complete all as specified and directed.
M&L for 1st quality joints free non skid ceramic colour tiles 7 to 8mm thick (square/rectangular) area of each tiles exc. 0.11 sqm but n. exc 0.18 sqm of approved colour as in floors etc set and joined in neat cement slurry over 15mm thick sreed bed of cement mortar (1:4) complete all as specified and directed by EIC.
M&L for glazed ceramic colour tiles 350X250x 7mm/450x350x7mm thick as in skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over 10mm thick rendering in cement mortar 1:3 complete all as spd and directed.
M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in floor for levelling course.
S&F in repairs closet Vitreous china squatting pan Orissa pattern of size 580x440mm white with integral foot rests (excluding flusing cistern and flush pipe) including connection to trap and to flushing pipe, antisyphonage connection pipe etc complete making good disturb surface with existing finish of floor all as specified & directed by Engineer-in-Charge.
S&F vitreous china wash down water closet pan, pedestal pattern Pedestal pan and trap(excluding flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc and including seat and cover for pedestal pan complete all as specified and directed.
S&F in repairs 10 litres capacity PVC low level flushing cistern complete with all fittings complete all as specified and directed by EIC.
S&F inrepair flush pipe of 32 mm dia polyethylene of low or high density of PVC for low level cistern complete all as specifie and directed.
M&L for plain cement concrete type B0(1:2:4) using 12.5mm graded stone aggregate as in benching, bed block, coping of manhole complete all as specified.
Extra for fair finish drain or channel to any girth in cement concrete, using extra cement, including forms moulds, mitred/stopped ends etc cmplete all as specified & directed by Engr-in-Charge.
Demolition of PCC in any description and in any position or otherwise specified complete all as specified and directed.
M&L for PCC type E-2 1:5:10 (using 40mm graded aggregate) as in filling of sunken floor complete all as specified and directed.
M&L for 10 mm thick cement plastering in cement mortar (1:3) finishing even and smooth without using extra cement mixed with WPC complete all as specified and directed.
M&L for (a) providing and laying water proofing treatment of sunken portion of WCs, bathroom etc by applying cement slurry with acrylic based modified cementious composite compound coating of make as pproved in technical instruction 5/2003 (b) First layer of slurry of cement @ 0.500 Kg/Sqm mixed with acrylc based polymer modified cemmentious compounds @ 0.250 Kg/Sqm. This layer will be allowed to cure for 4 hours. (c) Second slurry of cement @ 0.500 kg/Sqm mixed with acrylic based polymer modified cementious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cur for 4 hours followed with water curing for 48 hours.
S&F 32 mm dia GI spout light grade for sunken portion complete all as directed at site.
S&F in repair grating square or round 150mm size of PTMT (minimum 100 gms) complete all as specified and directed.
Supply & Fix in repair CP health faucet with 1.50 Mtr long tube & hook complete all as specifieed and directed.
Cutting all plant/trees growth at top of roof and outer surface of walls/sanitary/water supply pipe lines pouring of acid on the root removed area and cleaning of surfaces and making good in CM 1:4 or PCC 1:2:4 type B0 using 12,5 graded stone aggregate and finishing the surface smooth including removing all algae and waste materials (the raye is inclusive of formwork/scaffolding required too reach the area of vegitation growth and removing debries to distance n. exc 50m complete all as specified.
Taking up or down 15mm dia bore steel tubing and connection including cleaning for refixing or remove to store complete all as specified and directed.
S& F 15 mm dia bore steel tubing medium grade and connection complete all as specified and directed.
All as per item No 75.00 mentioned here-in-above but fixing only.
M&L for joining / sealing the joints of PVC pipe collar, band, tee eyc with PVC solvent cement or equivalent to prevent the leakage through the respective joints complete all as specified & directed by Engineer in Charge for 110mm bore pipe.
M&L for cement concrete Type B0 (1:2:4 ) using 12.5mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edge.
S & F mild steel work such as Bands, straps, supports or stays for rainwater, ventilating pipes, handmade clamps, hold fasts and similar small articles conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed.
M & L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 40mm graded aggregate) as in plith protection complete all as specified and directed..
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .