Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-Finance 10 CRP GARDEN 4TH STREET KODAMBAKKAM CHENNAI TAMIL NADU 600024 | CHENNAI | TAMIL NADU | 600024 | ₹24.4 L | L1 | Accepted-Finance Qualified for the award of contract |
| 2 | Not Admitted-Fee/PreQual/Technical 3 WOOD STREET ASHOK NAGAR BANGALORE KARNATAKA 560025 | BENGALURU URBAN | KARNATAKA | 560025 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹52,000
Closing Date
27 May 2024, 3:00 pmClosed
The Senior Manager (Project Purchase)
The Senior Manager (Project Purchase) ICSR, IITM, Chennai-36
PRECISION AIR CONDITIONING UNITS DX TYPE UNITS WITH EC FAN MOTORS and DIGITAL SCROLL COMPRESSORS
2024_IITM_195023_1
CY/PRAD/018/2024/PREAIRCOND
Open Tender
Miscellaneous Goods
Supply
21 days
The Department of Chemistry, IIT Madras
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹52,000
Yes
2 Jul 2024
7 May 2024
28 May 2024
7 May 2024
27 May 2024
8 May 2024
HVAC Supply,loading unloading lifting, installation, commissioning and testing of High Precision package type DX air cooled unit with top/ side discharge, air cooled condenser with fan and motor, with filter section, EC motor with plug type axial fan, air cooled condenser coil with anti corrosive paint, twin scroll compressor motor set with R 407C/R 410A refrigerant, condensate drain pan, in built data logger, power monitor relay, liquid receiver, thermostatic expansion valve, vibration absorber for compressor, HP/ LP cutouts, Water detector sensor, fire tripping relay, in built auto sequencing program, micro processor panel, digital display, programmable control and recording unit, alpha numeric display, function keys, cursor keys, free programmable keys, multi color LEDs, Humidifier, Heater, battery back up supply at 24 V/ 50 cycles/sec etc. The unit shall be suitable for operation on 415 V, 3 phase supply. The display panel shall display date, time, actual & set values, fault timing values,. Controls shall be suitable for linking to Building Automation System Modbus open protocol.
Capacity 28 KW (8 TR) temperaure 20 +/- 0.8 deg C, Relaitve humidity 50% +/- 5% RH.
MS painted pedestal for both outdoor & Indoor Units
Supply and laying of 18/19G copper refrigeration piping with all fittings should be long bend (no elbow) with proper insulations, supports, nylon tape wrapping etc
34.9 mm copper pipe
22.2 mm copper pipe
Supply and laying of copper conductor cable from main panel to control panel as required.
Supply and laying of copper conductor power cable between indoor and outdoor as required
Supply and laying of copper conductor communication cable between units for sequencing as required.
Supply and laying of GI ducting, complete with anchor fasteners and GI supports, bracings as required, nut, bolt & gasket etc
22 G ducting:
Supply and installation of powder coated Aluminium Supply air grills and return air outlets:
Supply air grille with damper
Return air grille with motorized damper
Supply and installation of powder coated Aluminium fresh air damper and cowl:
Supply and installation of fusible link type fire damper: Frames 18 G Aluminium Louvres 20 G Aluminium
Supply and laying of fresh water and drain piping for the units with nitrile rubber insulation , with PVC piping of 4 Kg rating, complete with bends, fittings and supports
25 NB (Drain)
Supply and fixing of Perforated Cable tray with cover with horizontal & vertical bends, reducers, Tee's, cross over , suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr . incl cover. The rate shall inclusive of necessary theaded rods,nuts & bolts, making clamp in the Z perlin/Truss, cable tray clamps etc,(8 mm threaded rod shall be provided at every alternative purlin appx. 2 mtr length)
300 x 50mm x1.6mm
100 x 50mm x1.6mm
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .