Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC STATION ROAD P O UKHRA DIST BURDWAN PIN 713363 W B | UKHRA | BURDWAN | WEST BENGAL | 713363 | ₹6.0 L | L1 | Accepted-AOC TC recommendation |
| 2 | Rejected-Technical PANDADESWAR BARDHAMAN 713346 WEST BENGAL INDIA | PANDAVESWAR | BARDHAMAN | WEST BENGAL | 713346 | - | - | Rejected-Technical TC recommendation |
| 3 | Rejected-Technical GOPALMATH DURGAPUR DIST PASCHIM BARDHAMAN PIN 713217 W B | PASCHIM BARDHAMAN | WEST BENGAL | 713217 | - | - | Rejected-Technical TC recommendation |
| Sl No | Description | Qty | Unit | ANNAPURNA ENTERPRISE L1 |
|---|---|---|---|---|
| 1.00Discription of items | ||||
| 2.00 | Power transformer from old Sub-station to newly Construction sub-station | 1 | ls | 5,800 ₹5,800 |
| 3.00 | Installation, testing and commissioning of 1MVA 11KV/500V power transformer including placement. making connection of both side etc. providing insulating tape etc. with inpulse legal test | 1 | no | 30,000 ₹30,000 |
| 4.00 | Transportation of 11KVx400Anmops VCB from 11KV old Sub-station to 11KV Sub-station with making disconnection, loading, unloading etc. Unskilled 4 heads @ 892/- Supervision 1head @ 926/- | 1 | no | 5,200 ₹5,200 |
| 5.00 | Installation, testing and Commissioning of 11KV x 400Amps VCB at news Sub-station including placement making cable connection of both Primary & secondary side Priming H.T. insulator etc. Unskilled 6 heads @ 892/-, Skilled 1 head @ 960/- | 1 | ls | 12,500 ₹12,500 |
| 6.00 | Disconnection of 2nos. 550Vx400Amps ACB at old sub-station transporting the same at new Sub-station and installation, transportation, commissioning of the same for each Unskilled 4 heads @ 892/- | 7 | no | 5,300 ₹37,100 |
| 7.00 | Loading, unloading and transportation of 250KVA 11KV/550V Power transformer from old Sub-station to news Sub-station after making disconnection of primary and secondary cable Unskilled 5heads@ 892/- | 1 | ls | 5,100 ₹5,100 |
| 8.00 | Installation, testing & commissioning of 250KVA 11KV/550V Power transformer including placement, making connection of both primary & secondary side with providing H.T insulation. Unskilled 6heads @926/- | 1 | ls | 13,800 ₹13,800 |
| 9.00 | Laying and erection of 50-120 Sqmm 11KV/3.3KV/1.1KV 100 grade PVC/XLPE cable from 11KV G.O.S. to 11KV VCB to 1MVA transformer to busbar to 550V switch gear and 11KV G.O.S. to 250KVA transformer to 550V OCB to Busbar chamber to 550V ACB/OCB 100Mtr. | 100 | mtr | 185 ₹18,500 |
| 10.00 | Making terminal kit joint of 50-120Sqmmm PVC/XLPE cable with supply of 3m make 11KV grade O/D type heat shrink terminal kit joint | 1 | no | 26,200 ₹26,200 |
Tender Value
₹6.0 L
EMD Value
₹7,500
Closing Date
9 Oct 2025, 6:00 pmClosed
General Manager Bankola Area
Office of The General Manager Bankola Area, PIN-713363
Installation, testing and commissioning of H.T. and L.T. electrical devices at new 11KV substation of VK unit of Khandra Colliery under BAnkola Area.
2025_ECL_344644_1
ECL/GM/BA/E TENDER/25-26/ENM/131 Dt 26.09.2025
Open Tender
Electrical and Maintenance Works
30 days
Khandra Colliery
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,500
10 Apr 2026
26 Sept 2025
10 Oct 2025
26 Sept 2025
9 Oct 2025
26 Sept 2025
26 Sept 2025 - 3 Oct 2025
Amount
Discription of items
Power transformer from old Sub-station to newly Construction sub-station
Installation, testing and commissioning of 1MVA 11KV/500V power transformer including placement. making connection of both side etc. providing insulating tape etc. with inpulse legal test
Transportation of 11KVx400Anmops VCB from 11KV old Sub-station to 11KV Sub-station with making disconnection, loading, unloading etc. Unskilled 4 heads @ 892/- Supervision 1head @ 926/-
Installation, testing and Commissioning of 11KV x 400Amps VCB at news Sub-station including placement making cable connection of both Primary & secondary side Priming H.T. insulator etc. Unskilled 6 heads @ 892/-, Skilled 1 head @ 960/-
Disconnection of 2nos. 550Vx400Amps ACB at old sub-station transporting the same at new Sub-station and installation, transportation, commissioning of the same for each Unskilled 4 heads @ 892/-
Loading, unloading and transportation of 250KVA 11KV/550V Power transformer from old Sub-station to news Sub-station after making disconnection of primary and secondary cable Unskilled 5heads@ 892/-
Installation, testing & commissioning of 250KVA 11KV/550V Power transformer including placement, making connection of both primary & secondary side with providing H.T insulation. Unskilled 6heads @926/-
Laying and erection of 50-120 Sqmm 11KV/3.3KV/1.1KV 100 grade PVC/XLPE cable from 11KV G.O.S. to 11KV VCB to 1MVA transformer to busbar to 550V switch gear and 11KV G.O.S. to 250KVA transformer to 550V OCB to Busbar chamber to 550V ACB/OCB 100Mtr.
Making terminal kit joint of 50-120Sqmmm PVC/XLPE cable with supply of 3m make 11KV grade O/D type heat shrink terminal kit joint
Making terminal kit joint of 50-120Sqmmm PVC/XLPE cable with supply of 3m make 11KV grade I/D type heat shrink terminal kit for 2nos. transformer 4nos.
Supply and erection of 11KV x 400Amps x 3Post G.O.Switch with accessories
Supply and erection of fuse system unit
Socketing of cable with 50-90Sqmm
Construction of chemical earth pit with supply of 2nos.x50mm G.I. pipe, Earth spike,alies copper wire bentonite soil with electrode
Brick works earth pit with Kilbum bricks, cement etc.
Making connection from electrical installation to earth pit with 25x3mm G.I strip G.I bolt nut etc.
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
techsummary_357272.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.82 MB
Tendernotice_2.pdf
PDF • 1.25 MB
Tendernotice_3.pdf
PDF • 0.16 MB
BOQ_357272.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid