| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹29.2 L+₹1.5 L (5.36%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L2 | Rejected-Finance Reject | |
| 3 | L3₹32.1 L+₹4.4 L (15.8%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Reject | |
| 4 | L4₹32.6 L+₹4.8 L (17.4%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | L4 | Rejected-Finance Reject | |
| 5 | L5₹33.7 L+₹6.0 L (21.6%)Rejected-Finance PR CDA SC PUNE 01 THROUGH AO GE DEHU ROAD | L5 | Rejected-Finance Reject |
Tender Value
₹34.9 L
EMD Value
₹69,800
Closing Date
25 Mar 2020, 6:00 pmClosed
GE Dehu Road, Pune
GE Dehu Road, Pune
REWIRING AND REPAIRS TO FITTINGS FIXTURES OF MD OTM ACCN OF 323 AD REGT 950AD WK SHOP UNIT 763 DEMPSY ROAD ASC SUPPLY POINT UNDER GE DEHU ROAD
2020_MES_334239_1
8421
Open Tender
Civil Works
Item Rate
180 days
GE Dehu Road
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Dehu Road, Pune
₹69,800
Yes
24 Jun 2020
16 Mar 2020
27 Mar 2020
16 Mar 2020
25 Mar 2020
18 Mar 2020
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
M&L for point wiring with 1.5 sqmm single core multistranded copper conductor FRLS cable of PVC insulated and unsheathed type alongwith 1.5sqmm PVC insulated unsheathed single core multistranded copper conductor cable for continous earthing in & incl PVC casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/ (MS steel strips if required) including hard PVC boards/Boxes of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator etc for Note:-color coding to be followed as given R-Phase,B-Neutral & G- Earthing
One light point controlled by one switch
One fan point controlled by one switch & regulators
One light point controlled by two way switches
One bell point controlled by one switch
One socket 5 pin 5 Amps flush type on same board
One socket 5 pin 5 Amps flush type on independent board
M&L for point wiring with 2.5 sqmm single core multistranded copper conductor FRLS cable of PVC insulated and unsheathed type alongwith 2.5sqmm PVC insulated unsheathed single core multistranded copper conductor cable for continous earthing in & incl PVC casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/ (MS steel strips if required) including hard PVC boards/Boxes of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator etc for Note:-color coding to be followed as given R-Phase,B-Neutral & G- Earthing
S&F switch piano flush type single pole one way 5 Amps
S&F switch piano flush type single pole two way 5 Amps
S&F bell push, flush type single pole 5 Amps
S&F bell electric, AC 230 volts, single pole
S&F lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings
S&F switch socket combination 2 in 1, 5 Amps flush type
S&F switch socket combination 2 in 1, 3 pin 5 Amps and 3 pin 15 Amps flush type universal.
S&F ceiling rose surface type 65 X 50mm, isolated body with 3 terminals to be fixed on PVC block
supply and fix in repair regulator electronic step type for ceiling fans suitable for AC 230 volts 50 Hz 1200 / 1400mm sweep
Supply and fix in repair LED Fitting 18 Watts LED MODEL:LUMILINEBS18WLED830SPCWH MAKE :Havells or Equivalent in Philips/Luker/Bajaj/HPL
Supply and fix in repair LED Fitting 9 Watts LED MODEL:LUMILINEBS9WLED830SPCWH MAKE :Havells or Equivalent in Philips/Luker/Bajaj/HPL
Supply and fix in repair LED T-5 Fitting 20 Watts LED MODEL:HLPT51820PCGWW MAKE :HPL or Equivalent inPhilips/Luker/Bajaj/Havells
S&F in repair 45 W LED LOW BAY luminaire complete of CAT No SZHWGMX045 of Shakti or Equivalent in Crompton/bajaj/havells
S&F in repair LED Recess mounted LED fitting 18 Watts CAT NO LCTLSNE-18-FO-WW of CROMPTON orPLUTO1XIPLR15WLED840S of HAVELLS
S&F in repair LED Recess mounted LED fitting 28/36 Watts CAT NO LCTLSNE-36-FO-WW of CROMPTON or PLUTONEO2X2PLR34WLED840S of HAVELLS or HPLLEDEPN36WWS of HPL
S&F in repair LED Recess mounted LED fitting 15 Watts CAT NO LCDEP-15-WW of CROMPTON or EDGEPRORDDLR15WLED840S of HAVELLS or HPLLEDINS015WWR of HPL
S&F in repair LED Recess mounted LED fitting 15 Watts CAT NO LSDEP-15-WW of CROMPTON orEDGEPROSQDLR15WLED840S of HAVELLS or HPLLEDINS015WWS of HPL
S&F in repair LED DRIVER CAT NO LEDDRIVER36V28/36WS of HAVELLS or Equivalent for LED Recess mounted LED fitting 28/36 Watts.
S&F in repair LED floodlight 100 watt integrated fitting with high luminous output and mounting bracket flood light with Die cast housing all as required at site IP 66 Rating CAT NO :LFLN-120-CDL/60-M of Crompton or Eqivalent in Havells/Bajaj
S & F in repair sheet metal enclosure single pole and neutral with two pin earth plug and socket complete with double pole MCB 20 amp 240 volt AC supply
S & F in repair submain wiring with cable insulated single core multistranded copper conductor FRLS cable 1100 volts 2x 4 sqmm drawn through & incl PVC casing caping / PVC conduit of suitable size alongwith 2.5 sqmm copper conductor cable for earth continuity. (Note : 2 runs of 4 sqmm cable, one run of 2.5 sqmm cable and one run of PVC casing capping will be measured as one RM).
S & F in Repair submain wiring with cable insulated single core multistranded copper conductor FRLS cable 1100 volts 4x 6 sqmm drawn through & incl PVC casing caping / PVC conduit of suitable size alongwith 4 sqmm copper conductor cable for earth continuity . (Note 4 runs of 6 sqmm cable, one run of 4 sqmm cable and one run of PVC casing capping will be measured as one RM).
supply and fix in repair MCB DB SPN sheet metal enclosure double door suitable for mounting MCB 240 volts with 200 Amps rated busbar 12 way
-ditto- as per item No 23 above but 8 way
-ditto- as per item No 23 above but 6 way
-ditto- as per item No 23 above but 4 way
supply and fix in repair MCB DB TPN sheet enclosure double door Vertical type suitable for mounting MCB with 415 volts with 200 Amps rated busbar 12 way
-ditto- as per item No 23 above but 6 way
-ditto- as per item No 23 above but 4 way
supply and fix in repair MCB SP 240 volts 6-32 Amps
supply and fix in repair MCB SP 240 volts 40 Amps
supply and fix in repair isolator SPN 40 Amps 240 volts
supply and fix in repair MCB TP 40 Amps 240 volts
supply and fix in repair isolator TPN 32 Amps 240 volts
supply and fix in repair isolator TPN 63 Amps 240 volts
supply and fix in repair isolator TPN 100 Amps 240 volts
M&L for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick burried burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level duly connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel including excavation and earth work in any strata,PCC Chamber with cover,Charcoal and Salt as required & 15 mm Light Grade GI pipe from steel plate to DB in order to ensure satisfactory earth resistance result to the entire satisfaction of Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3 ) mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level duly connected to galvanised earth strip 25 X 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel including excavation and earth work inany strata,PCC Chamber with cover,Charcoal and Salt as required in order to ensure satisfactory earth resistance result to the entire satisfaction of Engr-in-Charge .
Supply and Fix strip 25 X 4 mm allumnium with saddles and fixing screws for roof and down conductors
supply and fix in repair LED Bollard pressure die cast powder coated housing with diffuser of IP 65 protection CAT NO LBLA2-10-CDL of of CROMPTON or Equivalent in havells/bajaj
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth for removing / laying underground cables etc and getting out in :
Soft soil
Hard soil
Returning, filling in incl spreading,levelling watering and well ramming in layer n exc.25 cm in soil.
Removing excavated surplus material to a distance n.exc 50 m and deposting where directed at a level n exc. 1.5 m above the starting point in any type of soil
Taking out LT Cable of any size all as specified and directed by Engr in Charge. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
Relaying of LT Cable of any size obtained from item no 35 as per site requirment as specified and directed by Eng in charge. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
Supply,laying,jointing , testing and commisioning in repair XLPE cable 1100 volts grade PVC insulated armoured & PVC sheathed with stranded aluminium conductor heavy duty ISI marked incl cable glands lugs bolts nuts washers etc to suit the cable size to be laid in trenches fixed along pole, LT pannel floor bore or through GI pipe laid under floors, Fixed, concealed in wall enclosed in GI pipe etc complete of following sizes
6 sqmm 2 core
10 sqmm 2 core
10 Sqmm 4 Core
16 sqmm 4 core
Taking out HDPE DWC Pipe of any size fall as Specified and directed by Engr in Charge. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
Relaying Only of HDPE DWC pipe of any size obtained from item no 38 as per site requirment as specified and directed by Eng in charge. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
Supply, laying HDPE DWC flexible type of size 40 mm dia for protection of LT cable laid in trenches including insertion of the cable complete all as specified and directed by Engr-in -Charge
S&F in replacement of old conventional type post top lantern to LED Post top lantern of maximum luminous flux 2500 lm, 6H100%+6H50%, CCT=4000K, CRI>70, column length above ground 4 mtr, aluminium bottom part 2 mtr, IP-68, complete with Light pole & CE certified all as specified & directed by Engr-in-charge. Make :- Philips cat Pat No. BGP161 or equivalent in CG/ Bajaj/ Havells
S&F in repair On load change over switch 415V,4 pole in sheet metal enclosure with current capacity 160 amp. MAKE:- C01604PEAV of HPL/Standard/Havellsor Equivalent
S&F in repair On load change over switch 415V,4 pole in sheet metal enclosure with current capacity 125 amp. MAKE:- C01254PEAV of HPL/Standard/Havellsor Equivalent
S&F in repair On load change over switch 415V,4 pole in sheet metal enclosure with current capacity 100 amp. MAKE:- CDC01004PEAV of HPL/Standard/Havellsor Equivalen.
S&F inrepair On load change over switch 415V,4 pole with in sheet metal enclosure current capacity 63 amp. MAKE:- CDC00634PEAV of HPL/Standard/Havellsor Equivalen.
Supply / fixing in repair looping in box PVC with internal size of 240 x 130 x 110mm mounted with porcelain insulators , connector and porcelain fuse cut out 16 Amps including mounting arrangements.
Supply & fix in repair MCCB 200 Amp, 4 pole, 415 V,with breaking capacity 36 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
Supply & fix in repair MCCB 160 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
Supply & fix in repair MCCB 125 Amp, 4pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
Supply & fix in repair MCCB 100 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
Supply & fix in repair MCCB 63 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
M&L in repair Fan capacitor 2.5 mfd for ceiling fan all as specified.
M&L in repair Fan capacitor 4 mfd for exhaust fan 9",12",15"all as specified and as directed by Engr-in-Charge.
Om Sai Enterprises
metro electrical services
Shri Sai Electricals
S Y Itkar Construction and Company
M/S kirpan Enterprises
Preeti Enterprises
shri yash enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .