| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAdmitted-Finance | ₹22.0 L | L1 | Admitted-Finance |
| 2 | L2₹26.8 L+₹4.9 L (22.2%)Admitted-Finance 355 85 GALI NO 16 ASHOK VIHAR PHASE II BHIM GARH KHERI ASHOK VIHAR PHASE II GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | ₹26.8 L+₹4.9 L (22.2%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical G 4 106 107 1ST FLOOR SECTOR 11 ROHINI NEW DELHI 110085 | NORTH WEST | DELHI | 110085 | - | - | Rejected-Technical Submitted MSE certificate against EMD submission is not acceptable as per tender annexure 1 i.e. ITB cl. 17.2.b for work contract and rejected against BEC Cl. no. B.2.4.a |
| 4 | Rejected-Technical | - | - | Rejected-Technical Submitted MSE certificate against EMD submission is not acceptable as per tender annexure 1 i.e. ITB cl. 17.2.b for work contract and rejected against BEC Cl. no. B.2.4.a |
| 5 | Rejected-Technical 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | - | - | Rejected-Technical Not submitted catalogue against BEC clause B.1, satisfactory execution certificate against PO against BEC cl.B.2.a., undertaking B.5.,B.6,B.7 and B.8 from OEM |
| Sl No | Description | Qty | Unit | Sri Bhavani Enterprises L1 | Mark Engineering Inc. L2 |
|---|---|---|---|---|---|
| 1.00A.VRF SYSTEM -EQUIPMENTS | |||||
| 1.01 | Supply of Outdoor units consists of 100% inverter scroll compressor, DC fan motor with aero-spiral fan blade, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator, Supports and necessary works etc. The Outdoor units shall be selected for 390C ambient conditions without any Deration and ODU selection (Ambient Deration Chart) Capacity details to be submitted. The outdoor unit heat exchanger Fins to be provided with Hydrophilic coating and additional Epoxy Coating for anti-corrosive protection. Top discharge outdoor unit above 16 HP should be with multi compressor. The Outdoor Units shall be suitable to operate in an ambient temperature range up to 530C in Cooling mode. The compressors should have Oil level sensors for real time oil sensing. The capacities are as mentioned below: -
-------------------------------------------------------------------------------
The Selected Outdoor units should deliver minimum COP of 3.4 at 100% Load at ARI Condition and COP of minimum 6.9 at 50% load at ARI Condition20 HP
-------------------------------------------------------------------------------
20 HP | 2 | Nos | 6,32,160 ₹7,45,948.8 Lowest | 7,37,000 ₹8,69,660 |
| 1.02 | Supply installation, testing and commissioning of following minimum capacity VRF Hi-wall mounted single throw cassette type Indoor unit equipped with washable synthetic media pre filter fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet cord less remote control, drain pan necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required . (including installation Kit if any)
-------------------------------------------------------------------------------
Hi-Wall Units with wireless remote
-------------------------------------------------------------------------------
2.0 TR | 8 | Nos | 1,84,000 ₹2,17,120 Lowest | 1,93,600 ₹2,28,448 |
| 1.03 | Supply installation, testing and commissioning of following minimum capacity VRF Floor Standing Tower Type Indoor unit equipped with washable synthetic media pre filter fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet cord less remote control, drain pan necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required . (including installation Kit if any)
-------------------------------------------------------------------------------
8.0 TR Floor Standing Tower Type IDU | 2 | Nos | 2,60,000 ₹3,06,800 | 2,15,600 ₹2,54,408 Lowest |
| 1.04 | Supply of Touch Screen Central Remote Controller as Specified. The Controller should be capable to Monitor and Control up to 128 Indoor Units, Scheduling, Interlock Control, Drawing View, Multi Level Grouping, Web Access, Emergency Stop & Alarm, Error Alarm by E-mail, Compatible for Power Consumption Monitoring and Energy Management, BMS Integration through BACnet IP/Modbus TCP, History/Operation Trend including cable, necessary supports etc. | 1 | RO set | 55,000 ₹64,900 Lowest | 1,48,500 ₹1,75,230 |
| 2.00B.VRF - LOW SIDE WORK | |||||
| 2.01 | Supply, Installation, Testing and Commissioning of the VRF units.
-------------------------------------------------------------------------------
Outdoor units | 2 | Nos | 30,000 ₹35,400 Lowest | 1,19,600 ₹1,41,128 |
| 2.02 | Supply, Installation, Testing and Commissioning of the VRF units.
-------------------------------------------------------------------------------
Indoor units | 10 | Nos | 20,000 ₹23,600 | 11,500 ₹13,570 Lowest |
| 2.03 | Supply and installation of Refrigerant copper piping, fittings with suitable closed cell nitrile rubber insulation covering with FRP tape. And scope includes all refrigerant pipes shall be properly supported and anchored to the building structure using anchors, brackets and supports etc | 125 | Rmt | 2,25,000 ₹2,65,500 Lowest | 2,41,500 ₹2,84,970 |
| 2.04 | Supply and charging of R410 additional refrigerant gas | 24 | kg | 20,400 ₹24,072 Lowest | 23,460 ₹27,682.8 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
21 Apr 2026, 3:00 pmClosed
S.PRASANNA - EE(Mech)
SCM Section - ONGC ,CMDA Tower 1, , Chennai , Egmore (7710092421 / [email protected])
Supply Installation Testing and Commissioning of VRV VRF Air Conditioner 20 HP Outdoor Unit with 8 TR 2 Nos and 2 TR 8 Nos for Datacenter and UPS Room Cauvery Basin ONGC CMDA Tower 1 Egmore Chennai
2026_ONGC_273356_1
M25PC26005
Open Tender
Civil Works
Works
56 days
ONGC office CMDA Tower 1 Egmore
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹50,000
Yes
14 Aug 2026
31 Mar 2026
22 Apr 2026
31 Mar 2026
21 Apr 2026
31 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1A.VRF SYSTEM -EQUIPMENTS | |||||
| 1.01 | Supply of Outdoor units consists of 100% inverter scroll compressor, DC fan motor with aero-spiral fan blade, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator, Supports and necessary works etc. The Outdoor units shall be selected for 390C ambient conditions without any Deration and ODU selection (Ambient Deration Chart) Capacity details to be submitted. The outdoor unit heat exchanger Fins to be provided with Hydrophilic coating and additional Epoxy Coating for anti-corrosive protection. Top discharge outdoor unit above 16 HP should be with multi compressor. The Outdoor Units shall be suitable to operate in an ambient temperature range up to 530C in Cooling mode. The compressors should have Oil level sensors for real time oil sensing. The capacities are as mentioned below: -
-------------------------------------------------------------------------------
The Selected Outdoor units should deliver minimum COP of 3.4 at 100% Load at ARI Condition and COP of minimum 6.9 at 50% load at ARI Condition20 HP
-------------------------------------------------------------------------------
20 HP | - | Nos | - | - |
| 1.02 | Supply installation, testing and commissioning of following minimum capacity VRF Hi-wall mounted single throw cassette type Indoor unit equipped with washable synthetic media pre filter fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet cord less remote control, drain pan necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required . (including installation Kit if any)
-------------------------------------------------------------------------------
Hi-Wall Units with wireless remote
-------------------------------------------------------------------------------
2.0 TR | - | Nos | - | - |
| 1.03 | Supply installation, testing and commissioning of following minimum capacity VRF Floor Standing Tower Type Indoor unit equipped with washable synthetic media pre filter fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet cord less remote control, drain pan necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required . (including installation Kit if any)
-------------------------------------------------------------------------------
8.0 TR Floor Standing Tower Type IDU | - | Nos | - | - |
| 1.04 | Supply of Touch Screen Central Remote Controller as Specified. The Controller should be capable to Monitor and Control up to 128 Indoor Units, Scheduling, Interlock Control, Drawing View, Multi Level Grouping, Web Access, Emergency Stop & Alarm, Error Alarm by E-mail, Compatible for Power Consumption Monitoring and Energy Management, BMS Integration through BACnet IP/Modbus TCP, History/Operation Trend including cable, necessary supports etc. | - | RO set | - | - |
| 2B.VRF - LOW SIDE WORK | |||||
| 2.01 | Supply, Installation, Testing and Commissioning of the VRF units.
-------------------------------------------------------------------------------
Outdoor units | - | Nos | - | - |
| 2.02 | Supply, Installation, Testing and Commissioning of the VRF units.
-------------------------------------------------------------------------------
Indoor units | - | Nos | - | - |
| 2.03 | Supply and installation of Refrigerant copper piping, fittings with suitable closed cell nitrile rubber insulation covering with FRP tape. And scope includes all refrigerant pipes shall be properly supported and anchored to the building structure using anchors, brackets and supports etc | - | Rmt | - | - |
| 2.04 | Supply and charging of R410 additional refrigerant gas | - | kg | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
Tenderr.rar
Tender Documents • 0.41 MB
BOQ_319054.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .