| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹23.5 L+₹2.0 L (9.39%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹25.5 L+₹4.0 L (18.5%)Rejected-Finance JAI DURGA CONSTRUCTION COMPANY SAILI BYEPASS ROAD PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
3 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
REPR TO INT ELCTRFIN SYSTM AT MD ACCN CELING EXHAUST VNTLATN FANS AND LIGTNG PROTCN SYSTM OF BLDG EARTHNG AT MD OTM ACCN AT DAMTAL NANGLBHUR KANDRORI MIRTHAL KAUNTERPUR CMPLX UNDER GES PTK
2022_MES_543635_1
GES/PKT/T-31/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹86,000
Yes
21 Feb 2023
5 Aug 2022
5 Sept 2022
5 Aug 2022
3 Sept 2022
20 Aug 2022
Amount
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1200mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1400mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same(Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
Replacement of old unserviceable gun metal bush of ceiling fan complete all as spd and directed.
Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd ISI marked complete all as spd.
All as per Srl item 4 above but 3.15mfd complete all as spd.
Replacement of old unserviceable ball bearing suitable for 1200/1400 mm sweep complete. Make NBC/SKF (bearing with 8 balls shall only be used) complete all as spd.
Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
Replacement of old unserviceable fan blades, ISI Marked, suitable for 1200/1400mm sweep ceiling fan of any make complete all as spd.
Repalcement of old unserviceable MS down rod of appropriate External dia of ceiling fan complete (length of rod not less than 45cm and not more than 60cm and 15 mm dia) complete all as spd.
S&F Canopy for ceiling fan as per existing sample complete all as specified and as directed.
S&F PVC Two way connector for ceiling fan complete all as specified and directed.
Replacement of old unserviceable steel screw (to be used for fixing of fan blade) as per sample/ site requirement/ Make of fan complete all as spd.
Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/ oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed by Engr-in-Charge. (Unserviceable parts if any will be measured and paid seperately).
S&F cable PVC insulated and overall sheathed with flexible copper conductor Single core of size 1.0 sqmm complete all as specified and directed.
Dismantling and Re-winding of exhaust fan/industrial fan motor 250-300 mm sweep any make of fan with super enameled copper winding wire of suitable gauge as per existing including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections fan complete all as spd and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used).(ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
All as per Srl item 15 above but 350mm-450mm sweep complete all as spd and directed.
Dismantling of wall/pedestal fan of any sweep, repair the same by cleaning, overhauling, necessary lathe work (grinding & polishing) etc and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning and reassembling the wall/pedestal fan after replacement of unserviceable minor parts such as frame nut, knob, regulator switch clamp of cendenser etc as required for smooth functioning of the fan and Replacement of unserviceable major parts like capacitor, bearing, bush etc and testing complete on completion and re-fixing the fan in existing position including provn of twin twisted flexible copper stranded conductor wire of size 23/0.0076 Sqmm of required length complete as directed by the Engineer-in-Charge (Note : (a) Replacement of unserviceable major parts like capacitor, bearing, bush etc shall be measured and paid separately as "Supply only" under respective items of this Schedule. (b) Unit quoted rate shall deemed to be inclusive of transportation of fan to workshop form MES store yard)
S&F louver, suitable for exhaust fan of any make and size upto 300-350 mm, fixed in repair complete all as specified and as directed.
All as per items 18 above but of size 400 mm-450 mm
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to ceiling fan 1200-1400mm sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to exhaust fan/wall mounting fan/Padestial Fan of any sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
S&F in repair ceiling fans 1200 mm Sweep Ceiling Fan, Energy Saving, BLDC Motor without romote complete with canopy, blades, down rod, split pin etc complete of approx wattage 30 to 32 Watt rated suitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard.
S&F in repair Ventilation fan AC sinlge phase 230/240 volts of size 200 to 250 mm sweep PVC body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F Exhaust fan AC sinlge phase 230/240 volts of size 450 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F in repair wall mounted fan 400 mm Sweep Energy Saving, copper wounded Motor, three speed control complete suitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard
M&L for attending routine complaints for fan including retificaiton of minor defects by taking down the existing ceiling/wall mounted/exhaust fan of any size repairing and refixing after changing of defects/unserviceable parts such as changing of capacitors, changing of fan regulators, bypin holdets, shakle assy, fixing of loose connection ect complete all as specifed and directed by Engr-in-Charge. (Note replacement of defect parts such as fan regulator, bipin holder, capacitors, shakel assy atc shall be measured and paid separately under relevant item. Electrician should collect compalint slip on daily basis at 9'O clock from complaint section and resubmit it after rectification at the complaint cell. (Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch 'A' . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the No of points made serviceable.(iii) The area for attending the complaints are Entire Dhangu complex (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.(v) The contractor should deploy the manpower from the day of exceptance of contractor, (vi) Fine for Rs 500 per day shall be chraged to the contractor for not deploying of man power on any day.
M & L for attending routine complaints for geyser including retificaiton of minor defects by taking down the existing geyser of any size repairing and refixing after changing of defects/unserviceable parts such as changing of syphon assembly, element, thermostat, indicators, PVC connection, fixing of loose connection etc complete all as specifed and directed by Engr-in-Charge. (Note replacement of defect parts such as syphon assembly, element, thermostat, indicators, PVC connection, etc shall be measured and paid separately under relevant item. Electrician should collect compalint slip on daily basis at 9'O clock from complaint section and resubmit it after rectification at the complaint cell. (Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch 'A' . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the No of points made serviceable.(iii) The area for attending the complaints are Entire Dhangu complex (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.(v) The contractor should deploy the manpower from the day of exceptance of contractor, (vi) Fine for Rs 500 per day shall be chraged to the contractor for not deploying of man power on any day.
S&F plug top polycarbonate 3 pin, 5Amp all as specified and directed by Engr-in-Charge
S&F PVC insulated and PVC sheathed 3 Core copper conductor flexible round cable of 02 Sq mm all as specified and directed by Engr-in-charge
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB'S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified and directed.
M&L for point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge.( In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
All as per srl item 32 above but for one light point controlled by 2 nos two way switches.
All as per srl item 32 above but for one 3 pin 5A socket outlet independent board.
All as per srl item 32 above but for one 5A socket outlet on the same board
All as per srl item 32 above but for one 5A socket outlet below the board.
All as per srl item No 32 above but for 15/16 Amps socket out let independent with 4.0 sqmm copper conductor.
M & L for replacement of existing un-serviceable switch with switch piano polycarbonate body flush button single pole two way 5 amps, 230 volts.
M & L for replacement of existing un-serviceable switch with switch piano polycarbonate body flush button single pole two way 15 amps, 230 volts.
M & L for replacement of existing old u/s switch with switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts.
M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body 2 in 1, 3 pin, 5 Amp and 15 Amp flush type all as specified and directed.
M&L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body ,5 pin , 5 Amp flush type all as specified and directed.
M&L for replacement of existing old u/s socket outlet with socket outlet Polycarbonate body , 5 pin 5 Amp flush type all as specified and directed.
M&L for replacement of existing old u/s bell push with bell push polycarbonate body type 5/6 Amp, 230 volts.
M&L for bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified.
M&L for replacement of existing old u/s fan regulator with fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed
M&L for replacement of existing old u/s ceiling rose with ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
S&F for replacement of existing old u/s lamp holder with lamp holder batten type polycarbonate body with back plate for batten fitting all as directed.
M&L for Modular point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches/sockets/ regulators/ ceiling roses etc)made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge.( In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Modular inner and outer frame plate shall be included in quoted rates (b) Proper colour coding is to be followed as per IS Specification. (c) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(d) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(e) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
All as per srl item 49 above but for one 3 pin module socket out let 5/6 Amps on same board.
All as per srl item 49 above but for one module socket out let 5/6 Amps on Independent board.
All as per srl item 49 above but for one module socket out let 5/6 Amps on below the board.
All as per srl item 49 above but for 15/16 Amps socket out let independent with 4 sqmm copper conductor.
M&L for replacement of existing un-serviceable switch piano with Modular switch 1 way 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable switch piano with Modular switch 2 way 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable switch piano with Modular switch 1 way 16A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable bell push with Modular bell push 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable socket outlet with Socket, 6A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable socket outlet with Socket, 16A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable fan regulator with modular fan regulator step type 120 watts 2 module complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing old u/s submain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
M & L for replacement of existing old u/s submain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
M & L for replacement of existing old u/s tube light fitting with energy saving decorative batten type fitting with LED tube rod 18/20 watt energy efficient tube light fittings LED complete with 4 feet long channel type made out of CRCA sheet powder coated complete with housing with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting (fittings shall be fitted on two plastic square/ round block. Note power factor should not be less than 0.90.
S&F LED Bulk head light fitting 1 X 13.5watts cool Daylight (CDL) round type premium quality diffuser for even distribution of light complete , connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
M & L for replacement of existing old u/s mirror light fittings with sleek energy efficient decorative LED mirror light 10 watts, 2 feet with diffuser complete with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/ PVC connector to light fittings (fittings shall be fitted on two plastic square/ round block. Note power factor should not be less than 0.90.
M&L for replacement of existing old u/s tube light fitting with energy saving decorative batten type fitting with LED tube rod 18/20 watt energy efficient tube light fittings LED complete with 4 feet long channel type made out of CRCA sheet powder coated complete with housing with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings (fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90.
S&F LED Lamp 230 volts,50 Hz,inverter LED 10 watt ,lumen 900 lm, Charging time 8 to 10 Hours, backup time 04 Hrs, operating temperature -10 to 50 degree celcius, back time 04 Hours, complete all as specififed and direccted.
M & L for replacement LED lamp 7 watt , 230 volts retrofit type complete all as spd and directed.
M & L for replacement LED lamp 15 watt , 230 volts retrofit type complete all as spd and directed.
M & L for replacement LED lamp 12 watt , 230 volts retrofit type complete all as spd and directed.
S&F in replacement sheet metal enclosure 4 way , with SPN DB's (grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in replacement sheet metal enclosure 8 way, with SPN DB's ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in replacement sheet metal enclosure 12 way, with SPN DB's (grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in replacement of existing old u/s MCB SPN with MCB SPN C curve ,240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
S&F in replacement existing unsv distribution board iron clad, with double door 4 way with IP-54,1K-09 protection, cemet spill prptector suitable for MCCB as incommer AC 415 Volts three pole with thermal release adjustable type (80% to 100 % ) and MCB as outgoing ,complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA, AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge.
S&F in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors, geyser, fans etc and other similar electrical items/ fittings etc. including providioning of small pieces of electrical wire if required of size 1.5 sqmm to 2.5 sqmm single core and length not exceding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge. (Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch 'A' . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the No of points made serviceable. (iii) The area for attending the complaints are Entire Station HQ kandrori area (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.(v) The contractor should deploy the manpower from the day of exceptance of contractor, (vi) Fine for Rs 500 per day shall be chraged to the contractor for not deploying of man power on any day.
S&F socket outlet Polycarbonate body 2 in 1, 3 pin 15 Amp flush type all as specified and directed.
S&F socket outlet Polycarbonate body , 5 pin 5 Amp flush type all as specified and directed.
S&F in repair of Hylum sheet 5x5 to 10 x 12 inches for fixing of switches, sockets etc including cutting for fixing on existing or new sunken box with brass screw complete all as specified and directed by Engr-in-charge
Supply & fixing in repair of pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth of size 4x4 to 10 x 12 inches for fixing bakelite sheet of suitable size complete all as specified and directed.
S&F in repair ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm , cut to size all as required at site.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 2.5 sqmm , cut to size all as required at site.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 4.0 sqmm , cut to size all as required at site.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 6.0 sqmm , cut to size all as required at site.
S&F in replacement of old u/s service cable size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as spd and directed.
All as per srl item 88 above but for service cable of size 10 sqmm,complete all as spd and directed.
All as per srl item 88 above but for service cable of size 16 sqmm,complete all as spd and directed.
S&F AC single phase 10-60A Net Meter DLMS compiance of accuracy class 1.0, 240V 50 Hz, with backlit LCD, Optical port (measures Import KWh, Export kWh, net kWh, V,I,kW, 6 month history of Energy), with Rs232 Port including dismatling of existing meter and deposting it yto MES store Yard, making all necessary input and output connection of the new energy meter. Complete all as specified & directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing). and dismantling old defective earthpit.
M&L earthing with steel earth plate electrode of size 60x60cmx6 mm thick buried directly in ground to a depth not less than 2.25m deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing). and dismantling old defective earthpit.
Supply and lay GI tubes 40mm dia bore light grade galvanised with all fittings laid in trenches etc for protection of cable
Cutting the tarmac/ hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
S&F in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and insulators made out of porcelain and fixing screws for roof conductor/ down conductor including nut bolts& washers drilling and riveting for joints of suitable size as required at site all as specified and directed by Engr -in- Charge. Note :- Porcelain insulators are to be fixed at an interval of not more than 75 cm
S&F in repair air termination single pointed aluminium rod 12mm dia and 300 mm long for fixing on GI pipe medium grade 40mm dia pipe duly making suitable fixing arrangement of one end of air termination rod all as specified and directed by engr-in-charge. Note: GI pipe required will measured and paid separately.
S&F in repair air termination single pointed copper rod 12mm dia 12mm dia and 300 mm long for fixing on GI pipe medium grade 40mm dia pipe duly making suitable fixing arrangement of one end of air termination rod all as specified and directed by engr-in-charge. Note: GI pipe required will measured and paid separately.
M&L for plain Cement concrete 1:2:4 type B-1, (Using 20 mm graded aggregate) as in foundation block for fixing GI pipe for installation of air termination rod etc. complete all as specified Note:- Unit rates includes for provn of form work for rough finished surfaces and finishing the exposed surfaces with 5 mm thick rendering in CM 1:3 all specified.
S&F in repair Test point terminal block made aluminum strip 25 x 3.15 mm of size 75x75 drilled and screwed on insulators compleete all as specified and directed.
S&F in repair Porcelain insulators fixied with two number of nuts and fixing of down/roof conductors including taking down of old ones complete all as specified and directed.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/S SATPAL & BROTHERS
JAI DURGA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .