Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.2 CrAdmitted-Finance | -18.51% | ₹2.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.3 CrAdmitted-Finance | -14.99% | ₹2.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹2.3 CrAdmitted-Finance | -12.57% | ₹2.3 Cr | L3 | Admitted-Finance |
| 4 | L4₹2.4 CrAdmitted-Finance | -11.29% | ₹2.4 Cr | L4 | Admitted-Finance |
| 5 | L5₹2.4 CrAdmitted-Finance | -11.11% | ₹2.4 Cr | L5 | Admitted-Finance |
Tender Value
₹2.7 Cr
EMD Value
₹5.5 L
Closing Date
14 Jan 2026, 6:00 pmClosed
EXECUTIVE ENGINEER-Water
UDA Office Udaipur
Work of Drinking Water Supply System Development in UDA Residencial Scheme Village-Amberi, Udaipur. 6401
2025_UITUD_521489_1
NIT_64_02
Open Tender
Civil Works - Water Works
180 days
Udaipur
Please Refer Tender Document
3 documents required · 3 mandatory
₹2,360
Refer Tender Document
₹5.5 L
Yes
23 Feb 2026
18 Dec 2025
15 Jan 2026
18 Dec 2025
14 Jan 2026
18 Dec 2025
Item Code [ phed o & m pipe line]:Item Type [Other] :: Maintenance of pipelines irrespective of size & material which includes repairing of bursts & leakages pollution control, survey & removal of choking , disconnection of illegal connections , collection& recording minimum 10 nos residual chlorine samples during daily supply timimgs , interconnections and all works related to pipeline network in existing distribution /rising main pipelines of all sizes by digging out suitable of pit in soft and loose soil/hard soil including cutting of black top , WBM &CC top of road of any size at work site .this will also include cutting of pipe ends , fixing
Item Code [2.15]:Item Type [Other] ::Sub Item Code [2.15 + 2.15.4]: Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 7.5 KW (10 HP) & head above 120 mtr.
Item Code [2.15]:Item Type [Other] :: Sub Item Code [2.15 + 2.15.6]: Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 9.3 KW (12.5 HP) & head above 120 mtr.
Item Code [bib cock phed bsr 1.29]:Item Type [Other] :: P & F Bib cock (IS : 8931 mark), superior quality of approved make, chrome plated with complete brass body including brass handle with wt. 300 to 325 gm.15 mm nominal bore.
Item Code [Cleaning of ohsr O&M 4.3]:Item Type [building] :: Sub Item Code [Cleaning of ohsr O&M 4.3 + 4.3.3]: Cleaning of Over Head Service Reservoir ( OHSR ) of below mentioned capacity including removal of all silt from reservoir, scrapping of walls, disinfection of reservoir after cleaning and disposal of silt up to 1.00 Km lead and painting the date of cleaning on the reservoir. 201 to 300 KL
Item Code [extra mdpe phed bsr]:Item Type [Other] :: Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.
Item Code [other o &m power factor ]:Item Type [Other] :: Providing and fixing of power factor control capacitor panel with Mtc. on monthly rental basis. The responsibility of contractor is to maintain minimum power factor as 0.96 If the contractor is failed to maintain minimum PF, and any surcharge on this account is levied by AVVNL the same shall be deducted from payment of contractor ( Per HP Per Month)
Item Code [PHED BSR 2023 4.1]:Item Type [Other] :: Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
Item Code [PHED BSR 2023 4.3]:Item Type [Other] :: Sub Item Code [PHED BSR 2023 4.3 + 4.3.1]: Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: Ordinary Rock
Item Code [PHED BSR 2023 4.3]:Item Type [Other] :: Sub Item Code [PHED BSR 2023 4.3 + 4.3.3]: Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: Hard Rock (blasting prohibited)
Item Code [phed o&m centrifugal pump]:Item Type [Other] :: Maintenance of centrifugal pump sets and motor/ Monoblock including cost of rewinding of motor, material components & accessories required to repair pumpsets, starters etc. of electric panels, deinstallation and re installation of pumpsets complete in all respect for per Centrifugal pump set with pannel per month. maintenance of histroy sheet as directed by Engineer-in-charge for centrifugal pump set per month . Operated load of Centrifugal Pump sets (HP) 13.0 HP to 20.0 HP
Item Code [phed o&m pump house ]:Item Type [Other] :: Running expenditure of pumphouses which includes complete operation of pumpmotor , maintenance of log-books as directed by Engineer-in-charge, general upkeeping of premises, security arrangements, Regular chemical dosing in CWR, cleaning and desilting of SR/CWR/SUMP once every six months, daily valve operation under the Campus of pump house and all other works as mentioned in scope of work in tender document for per pump house per month. (power supply up to 8 hrs) Upto 50 HP
Item Code [phed o&m tubewell]:Item Type [Other] :: Sub Item Code [phed o&m tubewell + 7.4.3]: Maintenance of tubewells which includes round the clock monitoring of tubewells of all sizes, complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, Lowering and unlowering of pumpsets complete in all respect, maintenance of log-books & Histroy sheet as directed by Engineer-in-charge for tubewell per month. For Urban water supply schemes. 8.0 HP to 10.0 HP
Item Code [phed o&m tubewell]:Item Type [Other] :: Sub Item Code [phed o&m tubewell + 7.4.4]: Maintenance of tubewells which includes round the clock monitoring of tubewells of all sizes, complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, Lowering and unlowering of pumpsets complete in all respect, maintenance of log-books & Histroy sheet as directed by Engineer-in-charge for tubewell per month. For Urban water supply schemes. 11.0 HP to 12.5 HP
Item Code [phed o&m valve]:Item Type [Other] :: Daily / perodical operation of valves at supply times for specified by department per sluice valve per month .(Valve rod and cap to be arranged by contractor)
Item Code [revised bsr 2023 k-9 150 mm]:Item Type [Other] :: Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 150 mm DIA
Item Code [REVISED PHED 2023 4.8]:Item Type [building] :: Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work. "M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)."
Item Code [Revised PHED BSR 2023 , 2.19]:Item Type [other] :: Sub Item Code [Revised PHED BSR 2023 , 2.19 + 2.19.1]: Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 3 core 4.0 Sq.mm
Item Code [Revised PHED BSR 2023 ,2.4]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023 ,2.4 + 2.4.2]: Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. Nominal bore 200 mm dia.
Item Code [Revised PHED BSR 2023 1.25]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023 1.25 + 1.25.1]: "Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC / DI / AC / MS / GI pipe line up to consumer meter/premises by using PP/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including MS/PP saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or ball valve (min. weight 165 gm) and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid separately. " For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
Item Code [Revised PHED BSR 2023 2.11]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023 2.11 + 2.11.2]: Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
Item Code [Revised PHED BSR 2023 6.13]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023 6.13 + 6.13.1.1]: "Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date) PN 1.6 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work." class PN-6 40 mm dia
Item Code [water meter ruidp 2023 19.66.2]:Item Type [Other] :: Supply, fixing, testing and commissioning of Multi jet magnetic type domestic water meter Class-B confirming to IS:779-1996 / EEC/ MDIL with end coupling as per relevant technical specification and the direction of the Engineer 20 mm size
Item Code [Revised PHED BSR 2023, 2.20]:Item Type [Other] ::Sub Item Code [Revised PHED BSR 2023, 2.20 + 2.20.1]: Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessar
y connection, testing etc. as required of size. 10.0 Sq.mm, 4 core
Item Code [Revised PHED BSR 2023, 2.23]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023, 2.23 + 2.23.3]: Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 MM DIA
Item Code [Revised PHED BSR 2023, 1.1]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023, 1.1 + 1.1.2]: "Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately." 100 mm dia
Item Code [Revised PHED BSR 2023, 1.1]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023, 1.1 + 1.1.3]: "Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-ch
Item Code [Revised PHED BSR 2023, 2.24]:Item Type [other] :: Sub Item Code [Revised PHED BSR 2023, 2.24 + 2.24.2]: Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 50 mm dia
Item Code [Revised PHED BSR 2023, 8.1]:Item Type [Other] :: Construction of Pump house of brick/ stone masonry of required size suitable for installation of maximum 4 no. Monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.
Item Code [Revised PHED BSR 2023, 8.3]:Item Type [Other] :: Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints.
Item Code [Revised PHED BSR 2023, 6.3]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023, 6.3 + 6.3.1.2]: "Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work." 100 mm
Item Code [Revised PHED BSR 2023,3.2]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023,3.2 + 3.2.13.4]: Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - "a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type). " "k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, 250KL capacity
Item Code [revised phed bsr 2023,6.1]:Item Type [Other] :: Sub Item Code [revised phed bsr 2023,6.1 + 6.1.1.2]: "Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work." Manually Operated CI Sluice valve of Class PN-1.0 100 mm HW
Item Code [Revised PHED BSR 2023,3.4]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023,3.4 + 3.4.1.1]: Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: - "a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. . b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. " "h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe
s of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. " Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE2,3 & 4 100 KL CAPACITY
Item Code [Revised PHED BSR 2023,4.6]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023,4.6 + 4.6.2]: Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. Granular courses
Item Code [Revised PHED BSR 2023, 6.1]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023, 6.1 + 6.1.1.2]: "Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work."Manually operated CI Sluice valve of class PN-1.0 100 mm HW
arge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately." 150 mm dia
Item Code [Revised phed bsr 2023,6.6]:Item Type [Other] :: Sub Item Code [Revised phed bsr 2023,6.6 + 6.6.1.2]: "Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work." Class PN 1.0 50 mm
Item Code [Revised PHED BSR 2023,4.6]:Item Type [Other] :: Sub Item Code [Revised PHED BSR 2023,4.6 + 4.6.1]: Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. bituminous courses
Item Code [revised phed bsr, 5.7]:Item Type [building] :: Sub Item Code [revised phed bsr, 5.7 + 5.7.3]: "Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ." Discharge 20 to 30 LPS and head 41 to 50 M
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Technical-Bid_02.pdf
Tender Documents • 1.59 MB
Scope_of_Work_02.pdf
Tender Documents • 2.62 MB
Financial-Bid_02.pdf
Tender Documents • 0.50 MB
BOQ_930385.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid