Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.4 LAccepted-AOC F A ROAD KUMARPARA HOUSE NO 1ST FLOOR KUMUDINI APARTMENT PO BHARALUMUKH PS BHARALUMUKH DIST KAMRUP M GUWAHATI 781009 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹72.5 L+₹10,000 (0.14%)Rejected-AOC | L2 | Rejected-AOC Not awarded | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Manual Tender Documents not submitted |
Tender Value
₹72.5 L
EMD Value
₹1.5 L
Closing Date
3 Feb 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, PWD(R), City Road Circle
Bamunimaidam, Guwahati
(1) Construction of Rehabari bani Nagar bye-Lane 1 (2) Construction of Rehabari Kali Mandir Path (3) Construction of Rehabari Sani Mandir Bye Lane path (4) Construction of Rehabari Vebakananda Path near Sarada Girls School under Mukhya Mantrir Paki
2024_PWD_35723_2
CS/GC-NGTRD/1/MMPNA-FM/2023-24
Open Tender
Civil Works
Works
120 days
Kamrup
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,176
Yes
₹1.5 L
Yes
21 Mar 2024
29 Jan 2024
3 Feb 2024
29 Jan 2024
3 Feb 2024
29 Jan 2024
29 Jan 2024 - 3 Feb 2024
Amount
Rehabari bani Nagar bye-Lane I : Construction of Subgrade and Earthen Shoulders : Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2) (a), ( Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) from private land
Dismantling of Structures : Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Construction of granular sub base by providing coarse graded materials, spreading in uruiorrn layers With motor grader on prepared surface, mixing by mix in place tnethod with rotavator, contplete as per cl an jnltjal lead of 5 km). Foc Grading - II materials
Water Bound Macadam : Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km.) (A) (iii), WBM , Grading-III (b)Using Screening Type-B (11.2mm Agg.)
Providing and laying Interlocking Concrete Block Pavement (ICBP) conforming to IS:15658-2006 including all lead and lift complete as per technical specification as directed. (a) 80mm thick interlocking precast blocks having compressive strength of 40N/sq.mm.
Construction of RCC Drain Load Bearing (0.90m x 0.90 m) : Earthwork in exavation for foundation of structure as per drawings and technical specification clause 307 including setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approved material. (i) Ordinary soil (A) manual means (Depth upto 3m)(Without de-watering)
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A) With crushed stone PCC Grade M15
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork RCC M20 (a) Height upto 5m
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe complete as per drawing and technical specification
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification (B) Clause 1204.3.8
Construction of Slab Culvert (0.60 m clear water) : Earthwork in exavation for foundation of structure as per drawings and technical specification clause 307 including setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approved material. (i) Ordinary soil (A) manual means (Depth upto 3m)(Without de-watering)
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A) With crushed stone PCC Grade M15
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe complete as per drawing and technical specification
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification (B) Clause 1204.3.8
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoRT&H specifications
Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on RCC Posts 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
1st Year Routine Maintenance
2nd Year Routine Maintenance
3rd Year Routine Maintenance
4th Year Routine Maintenance
Rehabari Kali Mandir Path : Construction of Subgrade and Earthen Shoulders : Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2) (a), ( Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) from private land
Dismantling of Structures : Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Construction of granular sub base by providing coarse graded materials, spreading in uruiorrn layers With motor grader on prepared surface, mixing by mix in place tnethod with rotavator, contplete as per cl an jnltjal lead of 5 km). Foc Grading - II materials
Water Bound Macadam : Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km.) (A) (iii), WBM , Grading-III (b)Using Screening Type-B (11.2mm Agg.)
Providing and laying Interlocking Concrete Block Pavement (ICBP) conforming to IS:15658-2006 including all lead and lift complete as per technical specification as directed. (a) 80mm thick interlocking precast blocks having compressive strength of 40N/sq.mm.
Construction of RCC Drain Load Bearing (0.90m x 0.90 m) : Earthwork in exavation for foundation of structure as per drawings and technical specification clause 307 including setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approved material. (i) Ordinary soil (A) manual means (Depth upto 3m)(Without de-watering)
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A) With crushed stone PCC Grade M15
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe complete as per drawing and technical specification
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification (B) Clause 1204.3.8
Construction of Slab Culvert (0.60 m clear water) : Earthwork in exavation for foundation of structure as per drawings and technical specification clause 307 including setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approved material. (i) Ordinary soil (A) manual means (Depth upto 3m)(Without de-watering)
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A) With crushed stone PCC Grade M15
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork RCC M20 (a) Height upto 5m
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe complete as per drawing and technical specification
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification (B) Clause 1204.3.8
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoRT&H specifications
Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on RCC Posts 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
1st Year Routine Maintenance
2nd Year Routine Maintenance
3rd Year Routine Maintenance
4th Year Routine Maintenance
Construction of Rehabari Sani Mandir Bye Lane path : Construction of Subgrade and Earthen Shoulders : Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2) (a), ( Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) from private land
Dismantling of Structures : Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Construction of granular sub base by providing coarse graded materials, spreading in uruiorrn layers With motor grader on prepared surface, mixing by mix in place tnethod with rotavator, contplete as per cl an jnltjal lead of 5 km). Foc Grading - II materials
Water Bound Macadam : Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km.) (A) (iii), WBM , Grading-III (b)Using Screening Type-B (11.2mm Agg.)
Providing and laying Interlocking Concrete Block Pavement (ICBP) conforming to IS:15658-2006 including all lead and lift complete as per technical specification as directed. (a) 80mm thick interlocking precast blocks having compressive strength of 40N/sq.mm.
Construction of RCC Drain Load Bearing (0.90m x 0.90 m) : Earthwork in exavation for foundation of structure as per drawings and technical specification clause 307 including setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approved material. (i) Ordinary soil (A) manual means (Depth upto 3m)(Without de-watering)
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A) With crushed stone PCC Grade M15
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe complete as per drawing and technical specification
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification (B) Clause 1204.3.8
Construction of Slab Culvert (0.60 m clear water) : Earthwork in exavation for foundation of structure as per drawings and technical specification clause 307 including setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approved material. (i) Ordinary soil (A) manual means (Depth upto 3m)(Without de-watering)
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A) With crushed stone PCC Grade M15
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe complete as per drawing and technical specification
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification (B) Clause 1204.3.8
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoRT&H specifications
Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on RCC Posts 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
1st Year Routine Maintenance
2nd Year Routine Maintenance
3rd Year Routine Maintenance
4th Year Routine Maintenance
Construction of Rehabari Vebakananda Path near Sarada Girls School : Dismantling of Structures : Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Construction of RCC Drain Load Bearing (0.90m x 0.90 m) : Earthwork in exavation for foundation of structure as per drawings and technical specification clause 307 including setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approved material. (i) Ordinary soil (A) manual means (Depth upto 3m)(Without de-watering)
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A) With crushed stone PCC Grade M10
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork RCC M20
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe complete as per drawing and technical specification
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification (B) Clause 1204.3.8
Construction of Slab Culvert (0.60 m clear water) : Earthwork in exavation for foundation of structure as per drawings and technical specification clause 307 including setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approved material. (i) Ordinary soil (A) manual means (Depth upto 3m)(Without de-watering)
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A) With crushed stone PCC Grade M10
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork RCC M20
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe complete as per drawing and technical specification
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification (B) Clause 1204.3.8
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoRT&H specifications
Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on RCC Posts 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
1st Year Routine Maintenance
2nd Year Routine Maintenance
3rd Year Routine Maintenance
4th Year Routine Maintenance
Maruti Enterprise
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .