Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC VILL CHHOTO CHAND GHAR PO BARA CHAND GHAR DIST NADIA PIN 741196 | 741196 | L1 | Accepted-AOC Quoted rate found Lowest (L1) | |
| 2 | L2₹23.3 L+₹1.3 L (5.83%)Rejected-Finance RAJA SARAT CHANDRA ROAD PURATULI ENGLISHBAZAR DIST MALDA PIN 732101 | MALDAH | WEST BENGAL | 732101 | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹26.0 L+₹4.0 L (18.3%)Rejected-Finance | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). | |
| 4 | L4₹26.2 L+₹4.3 L (19.3%)Rejected-Finance 4 4 FAIRLIE PLACE ROOM NO 630A HMP HOUSE KOLKATA 700001 700001 CALCUTTA CENTRAL DIVISION WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | L4 | Rejected-Finance Quoted rate found 4th Lowest (L4). | |
| 5 | Rejected-Technical 22 IIIRD FLOOR MAIN MARKET MOTI NAGAR DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | - | Rejected-Technical Technically disqualified. |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Aug 2021, 4:00 pmClosed
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Providing Electrical Power and SITC of 250 KVA Diesel Generator set for 1000 LPM PSA Plant in the premises of Malda Medical College and Hospital-Supply, Installation, Testing and Commissioning of 250 KVA DG Set.
2021_WBPWD_336883_1
WBPWD/EE/MED/e-NIQ-15/2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
75 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹50,000
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECT DIVN
27 Aug 2021
17 Jul 2021
11 Aug 2021
19 Jul 2021
9 Aug 2021
29 Jul 2021
28 Jul 2021
Amount
Supply, delivery at site on foundation, commissioning of 250 KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure including transportation, loading and unloading of the DG set, having following specifications :
ENGINE : -
Make : CUMMINS / VOLVO.
Engine Type : 4 Stroke Diesel Engine
Rated Output : 335 BHP or Higher
Duty : PRIME
Cooling : Water cooled with radiator
Cylinder : 6
Aspiration : Turbo Charged
Type of Governer : Electronic
Fuel Tank Capacity : Minimum capacity 360 Ltrs.
Fuel Consumption at 75% rated Load with Radiator or Fan : 42 Ltr./ Hr. or Less.
Fuel Consumption at 100% rated Load with Radiator or Fan : 58 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better.
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning / Shutdown, High Engine Water Temp. warning / Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V / 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning.
ALTERNATOR : -
Make : STAMFORD / LEROY SOMER.
Rating : 415 V., 3Ph. 50 Hz., 250 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : Screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : < 5%
AMF & DG PANEL : -
Cubical type floor mounted AMF panel panel from the manufacturer / OEM / having CPRI approved Manufacturer made of 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 250 KVA DG set having following specification/features.
i) 2 No. 400A, AC1 duty, 4 Pole power contactor & U/V release etc. [Make: ABB, Legrand, Schneider].
ii) 2 Nos. 400A, 4 Pole 50 kA MCCB with Microprocessor based LSIG protection (Make: Make: ABB, Legrand, Schneider).
iii) 400A on load front operated TPN change over switch with necessary Cu Bus bars and Cable connections to bypass the AMF system in emergent conditions.
iv) In Built By-Pass switch for rated capacity
v) On -delay timer for load change over
vi) On-delay timer for engine shut off
vii) Engine On-Off switch (Push button type)
ix) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
x) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
xii) Microprocessor based relay with composite meter for digital display of following.
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications.
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
ACOUSTIC ENCLOSURE : -
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-II norms.
BASE FRAME : -
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
Making 5400mm x 2400mm x 750mm (250mm below & 500mm above the ground level) foundation of 300mm PCC block on top (ratio 1:2:4), 150mm RCC block in middle & Soling compound in remaining with 3mm thick smooth cement finish including construction of blue scope roofing shade supported onsteel structure consisting of atleast 4(four) vertical supports and adequate horizontal support made up of iron pipes with water prof painting on primer, capable of providing protection against rain for the DG having following dimension 4800mm x 1890mm x 2800mm (height).
Supply & fixing of exhaust gas piping of suitable dia welded black 200mm dia MS class B pipe incl. all necessary bend supports and clamps anti vibration mounting insulation of exhaust system with 50mm thick mineral wool covered with wire mesh and aluminium cladding (from DG sets to top of the building plus 3mtr or as per CPCB) for 250 KVA DG set as per direction of EIC.
TERMS & CONDITIONS
(1) Rate should be inclusive of all taxes, duties & CESS etc including GST which will not be paid extra.
(2) All materials, equipments & accessories must conform to relavent IS / IEC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(3) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(4) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-II).
(5) Circuit Diagram for AMF Panel must be submited from the Manufacturer / OEM / CPRI approved Manufacturer.
(6) The entire set must be warranted atleast 15 months from the date of Delivery / 12 months / 5000 running Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years / 5000 running Hrs, whichever is earlier.
(7) The contractor will have to supply, deliver, install & satisfactory commission of the DG Set at the specific location as mentioned in the BOQ. After satisfactory commissioning of the DG the generator should be run for five (05) hours in full load capacity including over load of 10% for testing purpose. Fuel & Load Box (if required) for testing will be arranged by the agency in his own arrangement. No extra cost other than the quoted rate in BOQ will be entertained.
ARGHYA BHATTACHARYA
M/S N. C. HORE
Sohum Industrial Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .