Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC | L1 | Accepted-AOC L1 accepted | |
| 2 | L2₹11.7 L+₹1.2 L (11.1%)Rejected-Finance 73 5 NANAK NAGAR JAMMU 180004 J K | JAMMU | JAMMU | J K | 180004 | L2 | Rejected-Finance Other than L1 after deducting Sch of Credit Rs 50325.00 | |
| 3 | L3₹12.4 L+₹1.9 L (18.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 after deducting Sch of Credit Rs 50325.00 | |
| 4 | L4₹13.5 L+₹3.0 L (28.7%)Rejected-Finance | L4 | Rejected-Finance Other than L1 after deducting Sch of Credit Rs 50325.00 | |
| 5 | L5₹15.1 L+₹4.6 L (44.0%)Rejected-Finance | L5 | Rejected-Finance Other than L1 after deducting Sch of Credit Rs 50325.00 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
21 Oct 2021, 6:00 pmClosed
GE North Akhnoor
GE North Akhnoor C/O 56 APO
REPAIR MAINT OF SOLAR WATER HEATER AND CONNECTED ITEMS UNDER GE NORTH AKHNOOR
2021_MES_454984_3
GE(N)/AKH-34/2021-22
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
Class cat b (i)
8 documents required · 8 mandatory
₹500
Yes
GE North Akhnoor
₹28,000
Yes
27 Nov 2021
30 Sept 2021
23 Oct 2021
30 Sept 2021
21 Oct 2021
7 Oct 2021
Amount
Dismantling each panel of solar water heater capacity 1000 LPD (each panel of 100 LPD = 10 Nos) including hot and cold pipe line network,collection water tank located between the bldgs at 89 Armd Regt and shifting entire system on the bldg roof (double storey) and reassembling, reinstallation after replacement of serviceable parts, servicing, all as specified and dirceted by Engr-in-charge. Note: 1 Any damage caused during shifting of panels on roof shall bear by the contractor with replacement. 2 All Civil work replacement and servicing shall be measured and paid separetly
Supply only solar panel glass 5 mm thick toughened of size 6'x4'
Supply only heating element 3KW
Supply only insulation glass wool
Supply only complete panel of capacity 100 LPD. Make: Intersolar/TATA BP or equivalent
Supply only CPVC pipes SDR 11 having 25mm dia and plain CPVC SDR 11 fittings on walls/ceiling or laying in floor complete all as specified. Make: Supreme/Astral or equivalent.
Supply only CPVC pipes SDR 11 having 20mm dia and plain CPVC SDR 11 fittings on walls/ceiling or laying in floor complete all as specified. Make: Supreme/Astral or equivalent.
M & L for descaling of the collectors and hot water tank 1000 Ltrs Cap with the chemical solvent for removing all silt/rust complete and making the whole system leak proof complete all as specified and directed.
M & L for descaling of the collectors and hot water tank 500 Ltrs Cap with the chemical solvent for removing all silt/rust complete and making the whole system leak proof complete all as specified and directed.
M & L for descaling of the collectors and hot water tank 200 Ltrs Cap with the chemical solvent for removing all silt/rust complete and making the whole system leak proof complete all as specified and directed.
M & L for descaling of the collectors and hot water tank 100 Ltrs Cap with the chemical solvent for removing all silt/rust complete and making the whole system leak proof complete all as specified and directed.
M&L for complete collector panel of capacity 100 LPD incl all fittings and fixtures Make TATA BP,Intersolar or equivalent.
Supply and laying of CPVC pipes SDR 11 having 40mm dia and plain CPVC SDR 11 fittings in trenches complete all as specified
Supply and laying of CPVC pipes SDR 11 having 25mm dia and plain CPVC SDR 11 fittings on walls/ceiling or laying in floor complete all as specified
Supply, fabrication and fixing feeder pillar box of size 500x 450x500 mm made out of MS sheet of 2.0mm thick bent to shape & size factory made with welding, bending works suitable for including 200 Amps rated aluminium bus bars ( length of bus bar not less than 40 cm) 4No's ,making holes of any size and mounted on porcelain/epoxy based post insulators of appropriate size with suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and length of angle iron not less than 1 mtr, 0.5 mtr to be embeded in PCC below G.L and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping. Make DVEPL, Jaimaa, Electricfield
Material and labour for heating element ISI marked capacity 3 KW all as specified and directed.
Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 6 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Finolex/ Gloster/ Polycab
Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Finolex/ Gloster/ Polycab
Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Finolex/ Gloster/ Polycab
Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size 25mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP25SMIV Make Anchor or equivalent in Kalinga, supreme
Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size 32 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP32SMIV Make Anchor or equivalent in Kalinga, supreme
Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size 40 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP40SMIV Make Anchor or equivalent in Kalinga, supreme
Construction of PCC block around iron structure in the PCC 1:2:4 Type B1 size 1'x1'x1.5' for shifted 1000 LPD Solar water heater for srl item No 1 for embedded steel structure associated with installation of Solar heater including demolition of existing PCC all as specified and directed.
Material and labour for solar panel glass 5 mm thick toughned of size 6'x4' all as specified and directed.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation laying of pole stay assembly and laying of LT/HT cable and getting out in any type of soil complete all as specified and directed by the Engr-in-Charge
Returning filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in any type of soil complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
M & L for dry coarse sand as cushioning to cable 8 cm before laying HT/LT cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and directed.
M&L for aluminium sheet cladding over hot pipe for insulation incl binding clamp all as specified and directed.
M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. Make of Cable Havells, KEI, Anchor
Allied Technologies
M/S SAHNI CONSTRUCTION CO
Jiwan Singh
M/s Adikarah Construction Company
m/s vishkarma construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .