| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC First Lowest |
| 2 | L2₹1.3 CrRejected-AOC GURDASPUR | GURDASPUR | GURDASPUR | PUNJAB | ₹1.3 Cr | L2 | Rejected-AOC Second Lowest |
| 3 | L3₹1.4 CrRejected-AOC SHOP NO 20 CHEEMA CHOWK MITHAPUR ROAD JALANDHAR 144001 | JALANDHAR | PUNJAB | 144001 | ₹1.4 Cr | L3 | Rejected-AOC Third Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
16 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B AND R BR JALANDHAR CANTT
CONSTRUCTION OF URBAN PRIMARY HEALTH CENTRE (UPHC) AT SHEIKHE, REHABILIATION CENTRE IN DISTRICT JALANDHAR
2026_CEPW_162714_1
Re-Bid No 53 of 05/03/2026
Open Tender
Civil Works - Buildings
180 days
JALANDHAR
Please refer Tender documents.
13 documents required · 13 mandatory
₹10,000
₹2.8 L
Yes
18 May 2026
5 Mar 2026
17 Mar 2026
5 Mar 2026
16 Mar 2026
5 Mar 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR
Name of Work :- DNIT FOR CONSTRUCTION OF URBAN PRIMARY HEALTH CENTRE (UPHC) AT SHEIKHE, REHABILIATION CENTRE IN DISTRICT JALANDHAR
Contract No: Civil Works
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 i) CIVIL WORKS:- 2
2 Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m and Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres 3 Cum Excess(+) Full Conversion INR
3 Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type 4 Cum Excess(+) Full Conversion INR
4 Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth 5 Cum Excess(+) Full Conversion INR
5 Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) 6 Sqm Excess(+) Full Conversion INR
6 First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth 7 Cum Excess(+) Full Conversion INR
7 Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in super-sturcture. 8 Cum Excess(+) Full Conversion INR
8 Extra rate for First Floor 9 Cum Excess(+) Full Conversion INR
9 Extra rate for Second Floor 10 Cum Excess(+) Full Conversion INR
10 Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. 11 Sqm Excess(+) Full Conversion INR
11 Extra rate for First Floor 12 Sqm Excess(+) Full Conversion INR
12 Centering and shuttering for columns (Square or rectangular or poly gonal in plain) 13 Sqm Excess(+) Full Conversion INR
13 Extra rate for First Floor 14 Sqm Excess(+) Full Conversion INR
14 Extra rate for Second Floor 15 Sqm Excess(+) Full Conversion INR
15 Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. 16 Sqm Excess(+) Full Conversion INR
16 Extra rate for First Floor 17 Sqm Excess(+) Full Conversion INR
17 Extra rate for Second Floor 18 Sqm Excess(+) Full Conversion INR
18 Centring and shuttering for stair cases with sloping with soffits including risers and stringers. 19 Sqm Excess(+) Full Conversion INR
19 Extra rate for First Floor 20 Sqm Excess(+) Full Conversion INR
20 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 21 Sqm Excess(+) Full Conversion INR
21 Extra rate for First Floor 22 Sqm Excess(+) Full Conversion INR
22 Extra rate for Second Floor 23 Sqm Excess(+) Full Conversion INR
23 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete 24 Qtl Excess(+) Full Conversion INR
24 Extra rate for First Floor 25 Qtl Excess(+) Full Conversion INR
25 Extra rate for Second Floor 26 Qtl Excess(+) Full Conversion INR
26 First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. 27 Cum Excess(+) Full Conversion INR
27 Extra rate for First Floor 28 Cum Excess(+) Full Conversion INR
28 Extra rate for Second Floor 29 Cum Excess(+) Full Conversion INR
29 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure 30 Sqm Excess(+) Full Conversion INR
30 Extra rate for First Floor 31 Sqm Excess(+) Full Conversion INR
31 12.5mm thick cement plaster 1:5. 32 Sqm Excess(+) Full Conversion INR
32 Extra rate for First Floor 33 Sqm Excess(+) Full Conversion INR
33 Extra rate for Second Floor 34 Sqm Excess(+) Full Conversion INR
34 20mm thick cement plaster 1:5 in two coats work. 35 Sqm Excess(+) Full Conversion INR
35 Extra rate for First Floor 36 Sqm Excess(+) Full Conversion INR
36 Extra rate for Second Floor 37 Sqm Excess(+) Full Conversion INR
37 12.5mm thick cement plaster 1:4. 38 Sqm Excess(+) Full Conversion INR
38 Extra rate for First Floor 39 Sqm Excess(+) Full Conversion INR
39 Extra rate for Second Floor 40 Sqm Excess(+) Full Conversion INR
40 20mm thick cement plaster 1:4 in two coat work. 41 Sqm Excess(+) Full Conversion INR
41 Extra rate for First Floor 42 Sqm Excess(+) Full Conversion INR
42 Extra rate for Second Floor 43 Sqm Excess(+) Full Conversion INR
43 Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. 44 Sqm Excess(+) Full Conversion INR
44 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia. 45 Rmt Excess(+) Full Conversion INR
45 Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in- charge. UPVC 110 mm bend 46 Each Excess(+) Full Conversion INR
46 Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. a) UPVC 110 mm Coupling /Sockets 47 Each Excess(+) Full Conversion INR
47 Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. 48 Each Excess(+) Full Conversion INR
48 Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating 49 Each Excess(+) Full Conversion INR
49 Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on- edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. 50 Each Excess(+) Full Conversion INR
50 Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg./Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing 51 Sqm Excess(+) Full Conversion INR
51 Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. 52 Rmt Excess(+) Full Conversion INR
52 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead 53 Cum Excess(+) Full Conversion INR
53 Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres 54 Cum Excess(+) Full Conversion INR
54 Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material 55 Sqm Excess(+) Full Conversion INR
55 Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material 56 Sqm Excess(+) Full Conversion INR
56 Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. 57 Sqm Excess(+) Full Conversion INR
57 Extra rate for First Floor 58 Sqm Excess(+) Full Conversion INR
58 Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing 59 Sqm Excess(+) Full Conversion INR
59 Extra rate for First Floor 60 Sqm Excess(+) Full Conversion INR
60 Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) 61 Sqm Excess(+) Full Conversion INR
61 Extra rate for First Floor 62 Sqm Excess(+) Full Conversion INR
62 Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. 63 Sqm Excess(+) Full Conversion INR
63 Extra labour for projected nosing of stair case of any shape and design 64 Rmt Excess(+) Full Conversion INR
64 Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. 65 Sqm Excess(+) Full Conversion INR
65 Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. b) Door and window frame of size 113mmx60mmx with 35mm wide single rebate 66 Rmt Excess(+) Full Conversion INR
66 c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. 67 Rmt Excess(+) Full Conversion INR
67 Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area 68 Sqm Excess(+) Full Conversion INR
68 Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer- in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) 69 Kgs. Excess(+) Full Conversion INR
69 Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. 70 Sqm Excess(+) Full Conversion INR
70 Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position 71 Qtl Excess(+) Full Conversion INR
71 Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick 72 Sqm Excess(+) Full Conversion INR
72 Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm 73 Sqm Excess(+) Full Conversion INR
73 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm 74 Each Excess(+) Full Conversion INR
74 Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. 75 Rmt Excess(+) Full Conversion INR
75 Providing and fixing of 30mm thick factory made Polyvinyl Chloride (PVC) door shutter (without chowkhat) made of styles and rails of a UPVC Plug profile section of size 30mm x 60mm and wall thickness 2mm ±0.2mm with inbuilt decorative molding edging on one side. The styles and rails with plastic brackets of size 75x220mm meter and welded at the corners. The- stiles of the shutter reinforced by inserting galvanized MS tube of size 25x20mm and 1mm ± 0.1mm wall thickness. The lock rail made up of ‘H’ section, a UPVC Plug profile section of size 30mm x 100mm and 2mm±0.2mm wall thickness welded to the shutter style with a UPVC Plug profile section single panel of size not less than 620mm, having overall thickness of 20 mm and 1 mm±0.1 mm wall thickness with 20 mm panel beading of suitable size /Glass(4mm thick plain glass)/louver section, louver frame of suitable size, as per manufactures specification and direction of Engineering- charge. (For WC and bathroom door Shutter) 76 Sqm Excess(+) Full Conversion INR
76 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 77 Sqm Excess(+) Full Conversion INR
77 Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface 78 Sqm Excess(+) Full Conversion INR
78 Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade 79 Sqm Excess(+) Full Conversion INR
79 Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm 80 Sqm Excess(+) Full Conversion INR
80 Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti ncluding finishing the surface to required finish complete. 81 Sqm Excess(+) Full Conversion INR
81 Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. 82 Sqm Excess(+) Full Conversion INR
82 Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. 83 Sqm Excess(+) Full Conversion INR
83 Applying priming coat with metal primer on new steel or iron work including preparation of surface. 84 Sqm Excess(+) Full Conversion INR
84 Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T,bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 85 Sqm Excess(+) Full Conversion INR
85 Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M- 35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge. 86 Sqm Excess(+) Full Conversion INR
86 Dismentalling of wall in Brick work 87 Cum Excess(+) Full Conversion INR
87 Credit of Old Bricks @ 60% 88 Each Excess(+) Full Conversion INR
88 Credit of Bricks Bats @ 40 % 89 Cum Excess(+) Full Conversion INR
89 Iron grated doors, including pintle hinges & arrangements 90 Qtl Excess(+) Full Conversion INR
90 ii) PUBLIC HEALTH WORK:- 91
91 Sub Head-1 Internal Sewerage System 92
92 Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B 93
93 110mm o/d single socket SWR UPVC pipe lines laid complete 94 Mtr Excess(+) Full Conversion INR
94 90mm o/d single socket SWR UPVC pipe lines laid complete 95 Mtr Excess(+) Full Conversion INR
95 Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. 96
96 For 110mm o/d pipes 97
97 Elbow 90 Degree (All side socketed) 98 Each Excess(+) Full Conversion INR
98 Vent Cowls 99 Each Excess(+) Full Conversion INR
99 Coupler 100 Each Excess(+) Full Conversion INR
100 Single Tee With Door 101 Each Excess(+) Full Conversion INR
101 Floor Trap 110mm x 110mm 102 Each Excess(+) Full Conversion INR
102 For 90mm o/d pipes 103
103 Elbow 90 degree (all side socket) 104 Each Excess(+) Full Conversion INR
104 Coupler 105 Each Excess(+) Full Conversion INR
105 Single Tee With Door 106 Each Excess(+) Full Conversion INR
106 Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) 107
107 110mm o/d 108 Each Excess(+) Full Conversion INR
108 90mm o/d 109 Each Excess(+) Full Conversion INR
109 Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. 110
110 M.S. Holder bats clamps for 100mm i/d as per table-1 111 Each Excess(+) Full Conversion INR
111 Core cutting in RCC slab 125mm dia or 150mm dia withe the help of core cutting machine as per requirement at site & as desired by Engineer-in-Charge. 112 Each Excess(+) Full Conversion INR
112 Providing and fixing galvonised hanging clamp 100mm dia chimney type for PVC pipe, 12mm galvonised fully thread bar with nut bolt as per requirement at site & as desired by Engineer-in-Charge. 113 Each Excess(+) Full Conversion INR
113 Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 114
114 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm as per table-1 115 Each Excess(+) Full Conversion INR
115 Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 116
116 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal 117 Each Excess(+) Full Conversion INR
117 Sub Head-2 Internal Water Supply System 118
118 CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. 119
119 CPVC SDR 11 Pipe & fitting 16mm o/d 120 Mtr Excess(+) Full Conversion INR
120 SDR 11 CPVC pipes & fittings 20mm o/d 121 Mtr Excess(+) Full Conversion INR
121 CPVC SDR 11 Pipe & fitting 25mm o/d 122 Mtr Excess(+) Full Conversion INR
122 CPVC SDR 11 Pipe & fitting 32mm o/d 123 Mtr Excess(+) Full Conversion INR
123 CPVC SDR 11 Pipe & fitting 50mm o/d 124 Mtr Excess(+) Full Conversion INR
124 Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm 125 Mtr Excess(+) Full Conversion INR
125 Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. 126
126 Through wall 11.43 cm thick 127 Nos Excess(+) Full Conversion INR
127 Through wall 22.86 cm thick 128 Nos Excess(+) Full Conversion INR
128 Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete. 129
129 20mm i/d Brass Ball valves 130 Each Excess(+) Full Conversion INR
130 25mm i/d Brass Ball valves 131 Each Excess(+) Full Conversion INR
131 32mm i/d Brass Ball valves 132 Each Excess(+) Full Conversion INR
132 50mm i/d Brass Ball valves 133 Each Excess(+) Full Conversion INR
133 Sub Head - 3 Sanitary Installation 134
134 Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. 135 Each Excess(+) Full Conversion INR
135 Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut 136 Each Excess(+) Full Conversion INR
136 Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. 137 Each Excess(+) Full Conversion INR
137 Providing and fixing in position vitreous Chinaware white Indian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. 138 Each Excess(+) Full Conversion INR
138 Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm 139 Each Excess(+) Full Conversion INR
139 Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineerin-charge) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect. 140 Each Excess(+) Full Conversion INR
140 Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. 141
141 size 44cm dia (under counter round) 142 Each Excess(+) Full Conversion INR
142 Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineerin- charge) consisting of a pair of brackets, C.P. brass waste 40mm complete in all respect. 143
143 Size 470mmx370mmx180mm 144 Each Excess(+) Full Conversion INR
144 Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. 145
145 Double bowl Sink without drain board Overall size 1330x515 bowl size 560x410x200mm 146 Each Excess(+) Full Conversion INR
146 Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut 147 Each Excess(+) Full Conversion INR
147 Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. 148 Each Excess(+) Full Conversion INR
148 Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-in-charge) complete in all respect. 149 Each Excess(+) Full Conversion INR
149 Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. 150
150 C.P brass towel ring 151 Each Excess(+) Full Conversion INR
151 Providing and fixing in position C.P. Acryli shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-incharge ) fixed in with rawl plugs and C.P brass screws complete in all respect. 152
152 CP brass Acrylic Shelf size 560mmx130mm 153 Each Excess(+) Full Conversion INR
153 C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm 154 Each Excess(+) Full Conversion INR
154 Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. 155 Each Excess(+) Full Conversion INR
155 Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge ) complete in all respect. 156
156 C.P. brass Bib cock long nose/ long body without flange 157 Each Excess(+) Full Conversion INR
157 C.P Brass bib cock foam flow without flange 158 Each Excess(+) Full Conversion INR
158 Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. 159
159 C.P.brass 15mm Angle valve without flange 160 Each Excess(+) Full Conversion INR
160 C.P.brass 15mm Concealed stop cock with flange 161 Nos Excess(+) Full Conversion INR
161 Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. 162 Each Excess(+) Full Conversion INR
162 Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long 163 Each Excess(+) Full Conversion INR
163 Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) 164 Each Excess(+) Full Conversion INR
164 Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories: 165
165 C.P. brass Bib cock with Wall flange 166 Each Excess(+) Full Conversion INR
166 C.P.brass 15mm Angular stop cock with Wall flange 167 Each Excess(+) Full Conversion INR
167 C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body) 168 Each Excess(+) Full Conversion INR
168 C.P. brass toilet roll holder with flap 169 Each Excess(+) Full Conversion INR
169 C.P. brass towel rack 600mm long with lower hangers 170 Each Excess(+) Full Conversion INR
170 Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs 171 Each Excess(+) Full Conversion INR
171 Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. 172 Each Excess(+) Full Conversion INR
172 Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks 173 Litre Excess(+) Full Conversion INR
173 Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball 174
174 Brass Ball Cock with rod and Plastic Ball 32mm i/d 175 Each Excess(+) Full Conversion INR
175 Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. 176
176 G.I. tank nipple 25mm i/d 177 Each Excess(+) Full Conversion INR
177 G.I. tank nipple 50mm i/d 178 Each Excess(+) Full Conversion INR
178 Construction of Plateform complete as per specification & as desired by Enginer-in-charge 179
179 For 1000 ltr Water Tank 180 Each Excess(+) Full Conversion INR
180 For 2000 ltr Water Tank 181 Each Excess(+) Full Conversion INR
181 Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect. 182
182 35mm dia 900mm (36”) long 183 Each Excess(+) Full Conversion INR
183 35mm dia 1200mm (48”) long 184 Each Excess(+) Full Conversion INR
184 Foldable U Type 762mm long 185 Each Excess(+) Full Conversion INR
185 Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects 186 Each Excess(+) Full Conversion INR
186 Sub Head-4 Flooring and Wall Tile 187
187 Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material 188 Sqm Excess(+) Full Conversion INR
188 Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material 189
189 Total All Floor 190 Sqm Excess(+) Full Conversion INR
190 Extra rate for First Floor 191 Sqm Excess(+) Full Conversion INR
191 Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. 192
192 Total All Floor 193 Sqm Excess(+) Full Conversion INR
193 Extra rate for First Floor 194 Sqm Excess(+) Full Conversion INR
194 Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi att/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS :15622 (thickness to be specified by the manufacture of approved make in all colours,shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry@ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 195 Sqm Excess(+) Full Conversion INR
195 Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. 196 Sqm Excess(+) Full Conversion INR
196 Providing and fixing 10mm thick acid and/or alkali resistant tiles 300 mm x 300 mm of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge, in flooring or in dado / skirting on a bed of 12 mm thick mortar 1 : 4 (1 acid proof cement: 4 coarse sand). 197 Sqm Excess(+) Full Conversion INR
197 Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) 198 Rmt Excess(+) Full Conversion INR
198 Sub Head -5 Water Cooler 199
199 Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge) including carriage complete in all respect. 200
200 Water Cooler Full Steel Body 80/120 ltr without Stablizer Detail as per Table-3 201 Nos Excess(+) Full Conversion INR
201 Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- 202
202 Automatic Voltage Stablizer 2 KVA (For Water cooler) 203 Nos Excess(+) Full Conversion INR
203 Automatic Voltage Stablizer 4 KVA (For AC's) 204 Nos Excess(+) Full Conversion INR
204 Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. 205 Nos Excess(+) Full Conversion INR
205 Providing & Installing & Erection split type wall mounted air conditioner with inverter technology capacity 1.5 tonne 5 Star having nature friendly R32 or equivelant 230 volts single phase supply witht MCB arrangement for installing OD units on terrace/Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects. 206
206 As per detail attached in table 207 Each Excess(+) Full Conversion INR
207 Providing & Installing & Erection split type wall mounted air conditioner with inverter technology capacity 1.0 tonne 5 Star having nature friendly R32 or equivelant 230 volts single phase supply witht MCB arrangement for installing OD units on terrace/Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects 208 Each Excess(+) Full Conversion INR
208 Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. 209 Mtr Excess(+) Full Conversion INR
209 Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 10 Kgf/cm2 25mm i/d 210 Mtr Excess(+) Full Conversion INR
210 Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm 211
211 qty same as GI P 15mm i/d to 25 mm (Table-2) 212 Mtr Excess(+) Full Conversion INR
212 Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 213
213 Overall size 4.0sq.mm (84/0.3mm), 3Core 214 Mtr Excess(+) Full Conversion INR
214 Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. 215
215 Through wall 11.43 cm thick 216 Nos Excess(+) Full Conversion INR
216 Through wall 22.86 cm thick 217 Nos Excess(+) Full Conversion INR
217 Sub Work :- 2 218
218 Sub Head -1:- Detail of Tube well 219
219 Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , quipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. 220
220 Boring with 200mm id Housing Pipe Upto 150 m depth BGL. 221 Mtr Excess(+) Full Conversion INR
221 Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – incharge. 222
222 150 mm nominal size dia. 223 Mtr Excess(+) Full Conversion INR
223 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 224
224 150 mm nominal size dia. 225 Mtr Excess(+) Full Conversion INR
225 Supplying & Fixing of M.S pipe bail plug suitable for 150 mm dia UPVC casing pipe having thickness of socket as 12 mm ,length 100 mm & base plate of 8 mm thick complete in all respect. 226 Each Excess(+) Full Conversion INR
226 Supplying and fixing well cap having threads to fix on housing pipe complete in all respect 150mm id. 227 Nos Excess(+) Full Conversion INR
227 Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis) 228 Nos Excess(+) Full Conversion INR
228 Supplying at site wooden box of suitable size with lid and locking arrangement for preserving strata sample received from the bore 229 Nos Excess(+) Full Conversion INR
229 Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, Urainium etc.) 230 Nos Excess(+) Full Conversion INR
230 Development and stabilizing of the Tubewell with submersible pumping set of required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge. 231 Hrs Excess(+) Full Conversion INR
231 Providing sterlization of tubwell as per IS 2800-1991 232 Job Excess(+) Full Conversion INR
232 Providing and Installing Testing & Commiissioning of 1 Nos Electrically driven submersible Pump set of capable of delivering 70 LPM against a head of 72 mtr. (Minimum 3BHP) 233 Each Excess(+) Full Conversion INR
233 Providing and Installing Electric Control panel board consisting of electrical appliances such as automatic star Delta Push Button or oil immersed starter, Main switch, VM, Ampere Meter, ELCB, shut capacitor. Single phase, preventer, indicating laps, Kit-Kat etc. complete in all respets. (Minimum 3BHP) 234 Each Excess(+) Full Conversion INR
234 Providing and Fixing 50 mm G.I. Column Pipe (in 3mtr lengths each with flnages, screwed and welded on both sides) rubber gaskets, nuts and bolts 235 Mtr Excess(+) Full Conversion INR
235 Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 236
236 Overall size 2.5sq.mm (84/0.3mm), 3Core 237 Mtr Excess(+) Full Conversion INR
237 Construction of Gravel Pit outside the Pump Chamber. (0.90m Dia.) as per standard design & drawings of public health department. 238 Each Excess(+) Full Conversion INR
238 Supplying & Fixing of Well cap having thread to fix on housing pipe complete in all respects 239 Job Excess(+) Full Conversion INR
239 Supplying & Fixing of MS clamp of size 150mmx12mm made out of MS flat 1.52 mtr long suitable to fit housing pipe including the cost nut & bolts of suitable size complete in all respects 240 Job Excess(+) Full Conversion INR
240 Sub Head-3 :- Disinfection Unit 241
241 Providing, installing, testing and commissioning one no. electrically actuated diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 ltr. o f bleaching powder solution/ sodium hypo solution per hour under maximum delivery pressure up to 7kg cm2, and suction lift not less than 1.5m, as per DWSS standard specification ( Make: Milton Roy or equivalent Make) 242 Nos Excess(+) Full Conversion INR
242 Sub Head 2.4 243
243 Estate Water Supply 244
244 Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. 245
245 Earth work upto 1.5 m. Depth All classes of soil except rocky For 100mm pipe line 246 Cum Excess(+) Full Conversion INR
246 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 247
247 SDR 11 CPVC pipes & fittings 50mm o/d 248 Mtr Excess(+) Full Conversion INR
248 Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. 249
249 50mm i/d Sluice Valves flanged 250 Nos Excess(+) Full Conversion INR
250 Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. 251
251 Size 0.6 m. x 0.6 m. 252 Nos Excess(+) Full Conversion INR
252 Sub Head-1 Estate Sewerage 253
253 Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 254
254 110 mm o/d pipes 255
255 For Sewer Line GT to IC 4mtr each 110mm 256 Mtr. Excess(+) Full Conversion INR
256 160 mm o/d pipes 257
257 For Sewer Line IC to IC and IC to MH 4mtr each For Sewer Line as per Detail attached 258 Mtr. Excess(+) Full Conversion INR
258 Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. 259
259 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 260 Cum Excess(+) Full Conversion INR
260 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 261
261 For covering Sewer Line Type II 262 Cum Excess(+) Full Conversion INR
262 Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard 263
263 Inside size 75x120 cm 264
264 Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. 265
265 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 266
266 up to depth of Sewerline 267 Cum Excess(+) Full Conversion INR
267 PCC below Man hole 268 Cum Excess(+) Full Conversion INR
268 Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type 269 0.000 Cum Excess(+) Full Conversion INR
269 First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth 270 0.999 Cum Excess(+) Full Conversion INR
270 Cement Concrete 1:2:4 with stone ballast or shingle.using concrete mixing volumetric type 271 0.000 Cum Excess(+) Full Conversion INR
271 Floating coat of 1:5mm thick neat cement laid in one operation to the topping 272 0.000 Sqm Excess(+) Full Conversion INR
272 12.5 mm thick cement plaster 1:3 273 0.000 Sqm Excess(+) Full Conversion INR
273 Cement rendering on plaster 1mm thick 274 0.000 Sqm Excess(+) Full Conversion INR
274 Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. 275 0.000 Cum Excess(+) Full Conversion INR
275 Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete 276 Qtl Excess(+) Full Conversion INR
276 Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design 277 Nos Excess(+) Full Conversion INR
277 Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). RCC Man hole cover with Frame 560mm i/d RCC man hole cover with frame as per ISI 278
278 Heavy duty 279 Nos Excess(+) Full Conversion INR
279 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. For pipes 100 to 250 mm Diametre 280 One connection Excess(+) Full Conversion INR
280 Construction of Septic Tank size 2.00 Mtr x 1.50 Mtr. Internal size with 2.0 Mtr. Internal depth in RCC, 3 no. Chambers medium duty man hole cover complete as per drawing / specification and to the entire satisfaction of Engineer-in-charge. (Note :- Payment will be made as per CSR Based Rates Plus Minus Quoted rates). (Note :-To be provided near by Male Toilet Block) 281 Job Excess(+) Full Conversion INR
281 Making soak pit 2.5 m outer Diametre 3.0 metre deep 230 mm thick 1:5 brick work honey comb with bricks of 1st Class and S.W. drain pipe 100mm diametre, .8m long complete as per standard design with F.P.S 282 Each Excess(+) Full Conversion INR
282 Sub Work-4 283
283 Fire Fighting Arrangements 284
284 Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity 285 Nos Excess(+) Full Conversion INR
285 Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity 286 Nos Excess(+) Full Conversion INR
286 iii) ELECTRICAL WORK:- 287
287 Providing Internal Electrical Installations: 288
288 POINT WIRING: 289
289 RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 290
290 Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). 291 Each Excess(+) Full Conversion INR
291 RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): 292
292 Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 293
293 Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. 294 Each Excess(+) Full Conversion INR
294 RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 295
295 Wiring Networking socket point RJ45 (one module) 296 Each Excess(+) Full Conversion INR
296 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 297
297 Wiring fan point (with fan box ) 298 Each Excess(+) Full Conversion INR
298 Wiring light point 299 Each Excess(+) Full Conversion INR
299 Wiring call-bell point 300 Each Excess(+) Full Conversion INR
300 Wiring 6 Amp. wall socket point 301 Each Excess(+) Full Conversion INR
301 Wiring 6 Amp. Plug control comprising wall socket point 302 Each Excess(+) Full Conversion INR
302 Wiring 16/20 amp. power plug control point 303 Each Excess(+) Full Conversion INR
303 SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- 304
304 Ceiling Rose (Flush Piano type) 305 Each Excess(+) Full Conversion INR
305 Call Bell 220/230 volts AC Ding Dong 306 Each Excess(+) Full Conversion INR
306 COPPER WIRES & CONDUIT PIPE: 307
307 PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 308
308 Overall size 1.5sq.mm (Un-sheathed) 309 Mtr. Excess(+) Full Conversion INR
309 Overall size 2.5sq.mm (Un-sheathed) 310 Mtr. Excess(+) Full Conversion INR
310 Overall size 4sq.mm (Un-sheathed) 311 Mtr. Excess(+) Full Conversion INR
311 Overall size 6sq.mm (Un-sheathed) 312 Mtr. Excess(+) Full Conversion INR
312 Overall size 10sq.mm (Un-sheathed) 313 Mtr. Excess(+) Full Conversion INR
313 Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 314
314 Overall size 1.5sq.mm (48/0.20mm), 3Core 315 Mtr. Excess(+) Full Conversion INR
315 COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL ERVICES: 316
316 Supply and erection of Cat 6 with 23AWG Solid bare copperconductor special grade PE insulation with star separator 4 pair unsheathed twisted, class E, 250MHz of bandwidth,supporting data transfer speed of upto 10Gbps(10GBASE-T) for dstae upto approxymately 180 feet cables are manufactured and tested t meet the ANSI/TIA 568-C.2 and ISO /IEC 11801 Class E standards left bare in pipe or casing suitable size complete in all respect as desired by the Engineer-in-charge:- 317
317 CAT 6 LAN cable 318 Mtr. Excess(+) Full Conversion INR
318 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 319
319 Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed 320 Mtr. Excess(+) Full Conversion INR
320 Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed 321 Mtr. Excess(+) Full Conversion INR
321 Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- 322
322 PVC flexible pipe 40mm dia. 323 Mtr. Excess(+) Full Conversion INR
323 PVC Flexible Pipe 25mm dia. 324 Mtr. Excess(+) Full Conversion INR
324 HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- 325
325 Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. 326 Mtr. Excess(+) Full Conversion INR
326 G.I. EARTHING :- Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). 327
327 Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) 328 Each Excess(+) Full Conversion INR
328 G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- 329
329 Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) 330 Mtr. Excess(+) Full Conversion INR
330 Copper Earthing 331
331 Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation ha 332
332 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long 333 Each Excess(+) Full Conversion INR
333 Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- 334
334 Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 335 Meter Excess(+) Full Conversion INR
335 MCB'S & MCB DISTRIBUTION BOARDS: 336
336 MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 337
337 MCB Single Pole 6-32amp. (10kA, Curve-C) 338 Each Excess(+) Full Conversion INR
338 MCB Double Pole 40amp. (10kA, Curve-C) 339 Each Excess(+) Full Conversion INR
339 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 340 Each Excess(+) Full Conversion INR
340 MCB Four Pole 50, 63amp. (10kA, Curve-C) 341 Each Excess(+) Full Conversion INR
341 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: 342
342 Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- 343
343 SP&N Double Door Distribution Board 12 way each 344 Each Excess(+) Full Conversion INR
344 TP&N Horizontal Double Door Distribution Board 8 way each 345 Each Excess(+) Full Conversion INR
345 Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- 346
346 TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp) 347 Each Excess(+) Full Conversion INR
347 SHEET METAL IRON CLAD CHANGEOVER SWITCHES: 348
348 Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:- 349
349 IC Four Pole Changeover Switch 100amp., 415volts 350 Each Excess(+) Full Conversion INR
350 LT CABLES 351
351 XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- 352
352 Overall size 35sq.mm (3½ Core) Un-armoured (Loose) 353 Mtr. Excess(+) Full Conversion INR
353 DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 354
354 Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) 355 Mtr. Excess(+) Full Conversion INR
355 MCCB's (FOR PANELS & SHEET ENCLOSURE): 356
356 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 357
357 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 358 Each Excess(+) Full Conversion INR
358 Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- 359
359 Aluminium thimble cable Core size 4 - 6sq.mm 360 Nos Excess(+) Full Conversion INR
360 Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:- 361
361 Copper thimble cable Core size 4 - 6sq.mm 362 Nos Excess(+) Full Conversion INR
362 Copper thimble cable Core size 10 - 16sq.mm 363 Nos Excess(+) Full Conversion INR
363 LED'S FIXTURES & FANS: 364
364 Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. 365 Each Excess(+) Full Conversion INR
365 Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. 366 Each Excess(+) Full Conversion INR
366 Supply and erection of Surface mounted 36/40watt LED 1x4 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards), surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ±3% 5 year warranty including their drivers and hanging Gl wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. 367 Each Excess(+) Full Conversion INR
367 Supply and erection of LED Flood Light 50 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded luminium housing with control gear (IP 66 protection), THD<10%, CRI inimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. 368 Each Excess(+) Full Conversion INR
368 Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. 369 Each Excess(+) Full Conversion INR
369 Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. 370 Each Excess(+) Full Conversion INR
370 Supply and erection of wall Fan 400 mm Swing 16 inch including flexible wire & petty material etc. for connections and testing complete in all respect as approved by the engineer in charge at site. 371 Nos Excess(+) Full Conversion INR
371 Networking System : 372
372 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 373
373 Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed 374 Mtr. Excess(+) Full Conversion INR
374 Supply, Installation, Testing & Commissioning of 16-Port Gigabit Unmanaged Switch ,10/100/1000Mbps Gigibit Ethernet ,16 ,76W ,External Input 54V 3.7A(200W) Input 54V 2.4A(130W) Input 54V 1.66A(90W) ,Metal ,Desktop, wall & rack mount ,Power, Link/Activity ,Fanless ,Yes ,Yes ,Yes ,4K ,1MB ,32Gbps ,IEEE 802.3az complaint ,2,088,514 hours ,Yes ,Yes ,1:3:5:7:8:10:12:15 Weighted Fair Queue (WFQ) ,Input 54V 1.66A (90W) External ,90W ,0 dBA (Fanless) ,0° to 40°C (32° to 104°F) ,Class A ,11.26 x 4.02 x 1.06 in ,0.88 kg (1.94 lb) ,47 CFR FCC Part 15, SubpartB, Class A ICES-003:2016 Issue 6, Class A ANSI C63.4:2014 ,55032:2012+AC:2013, Class A EN 55024:2010 EN 61000-3-2:2014, Class A EN 61000-3-3:2013 ,AS/NZS CISPR 32:2015, Class A ,VCCI-CISPR 32:2016, Class A ,CNS 13438 ,CB. IEC 60950-1:2005(ed.2) + A1:2009 + A2:2013 ,UL/cUL Listed; UL60950-1, 2nd Ed. 2014; CAN/CSA C22.2 No. 60950-1-07, 2nd Ed. 2014 ,EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 ,AS/NZS 60950.1:2015 ,Lifetime Hardware Warranty ,90 Day's Free remote configuration support ,Replacement with new box product. complete in all respects as desired by the Engineer in charge of work at site. 375 Each Excess(+) Full Conversion INR
375 Supply & Erection of POE Powered Indoor Wi-Fi Access Point 1 Gbps Speed having 2.4Ghz and 5Ghz network, omni directional antenna, 01 No. Giga WAN port and, Password Protection, Wide Area Range, Ceiling /Wall Mount Flow Control, App Controlled, IEEE 802.3at PoE, Up to 100 Wi-Fi Users, Security Protocol WPA/WPA2/WPA3™ Personal/ Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control Power Supply Connect 12 V / 2.5 A (optional power adapter not included), IEEE 802.3at PoE, Support Port Forwarding, NAT Etc complete in all respects as desired by the Engineer in charge of work at site. 376 Each Excess(+) Full Conversion INR
376 SITC of CAT 6, 16 Port Fully loaded Patch Panel, Rack Mountable for cable termination complete in all respects as desired by the Engineer in charge of work at site. 377 Each Excess(+) Full Conversion INR
377 SITC of CAT 6 ONE Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps complete in all respects as desired by the Engineer in charge of work at site. 378 Each Excess(+) Full Conversion INR
378 SITC of CAT 6 TWO Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps complete in all respects as desired by the Engineer in charge of work at site. 379 Each Excess(+) Full Conversion INR
379 SITC of Token Calling Display System having screen size 4 inches, Voice calling with Bell System, complete key pad Etc, calling display up to 60 meter cable (15 meter length included), serial communication design, Text Color Red Display Shape Rectangle, Power 5 W, Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital, Cash counter, Tehsil, Courts etc, Warranty 1 Year,220 VAC Operating Voltage character Capacity 3 Character, Power Consumption, Rectangular Metal body complete in all respects as desired by the Engineer in charge of work at site.. 380 Each Excess(+) Full Conversion INR
380 Supply & installation of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks complete in all respects as desired by the Engineer in charge of work at site. 381 Each Excess(+) Full Conversion INR
381 Supply & installation of 1KVA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 382 Each Excess(+) Full Conversion INR
382 Supply and erection of Supply of RJ -45 Connector complete in all respects as per satisfaction of the Engineer in-charge at site. 383 Each Excess(+) Full Conversion INR
383 Supply, Installation, Testing and Comissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. 384 Each Excess(+) Full Conversion INR
384 Supply, Erection, Testing and Commissioning of 3 KVA Double Conversion Online UPS System including Batteries 12V 65ah Amp hrs. True Online Pure Sine wave DSP Controlled online UPS with single phase AC input and single phase AC output with inbuilt Isolation Transformer of same OEM make at Input Including installation & 2 years warranty. Along with battery rack, interconnection cables & 5/7-meter DC wire from UPS to battery bank and other standard accessories of UPS & Battery Bank. UPS is with inbuilt Phase sequence correction & protection feature , TVSS & Cold start feature and emergency power off (EPO) feature & dust filters, manual & automatic bypass inbuilt and UPS should be capable for Parallel operation up to 4 same units with additional optional PRS kit. UPS Rating : KVA 3, Load Power Factor: PF 0.8, Efficiency: 0.9, Nominal DC Voltage: VDC 12Vx no of batteries 8, No of Batteries: 8, End Cell Voltage: 1.75x6: 10.5, DC Watts: = (KVA X 1000 X PF) / (Inv Eff X No. of batt) Watts, DC watts: UPS load DC wattage 444, Backup time: in mins 60, AH Offered: AH rating of SMF battery: 65AH, No of cells/Batteries: 1string of 8 no. of 65AH, Min VAH of bank for 60 min: 1 set of 8 no. of 12V-65AH 10080, Battery AH Wattage: 65AH battery gives Backup calculation: Backup Achieved in min = battery AH wattage x 60 Min / UPS load DC watts: 33.14 min, Backup achieved more than 60 min backup achieved: on SMF battery bank with 10080VAH on 0.8LPF for 3KVA UPS. This 3kVA double-conversion on-line 2U rackmount UPS provides pure sine wave power to support critical electronics during power disruptions. The SRV comes with IEC 320 C20 input, 6x IEC 320 C13 and 1x IEC 320 C19 outlets. The On-Line UPS has a intelligent card slot for optional Network Management Card (AP9544, SRVSMB001, VGL9901l) that enables network-based UPS monitoring and management. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. The Built-in automatic and manual bypass provide seamless power to the load even in the event of an internal detected fault or error in UPS. The SRV UPS is compatible with replacement battery cartridge APCRBCV202. The UPS is compatible with SRVRK1 rail kit sold separately. The UPS and the built-in lead-acid battery has a 2-year warranty. Ideal for small data centers, manufacturing facilities, computer rooms, network storage devices, telecommunication, and healthcare IT. Complete in all respects as desire by the Engineer in-charge of work at site. 385 Each Excess(+) Full Conversion INR
385 Supply, Installation, Testing and Comissioning of industrial grade Emergency Exit Light with LED Sign - 2 Language, inbuilt Battery : 12V,7AH, made of power coated Sheet Metal, work with AC 220v,50Hz(+/15%) and Battery Light Source : 9W x 2 nos – LED Bulbs, Battery operating volts: 11V to 14V, Battery charger : Regulated constant volt constant current Battery charging Time : 7 to 8 Hrs (app) Power consumption : 10W(app) while charging, LED display diffuser : Red/ Green acrylic transparent, Tiltable, Auto lights up while power failure complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. 386 Each Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.20 MB
BOQ_329815.xls
BOQ • 0.77 MB
Technical_Conditions.pdf
Tender Documents • 5.53 MB
SBD.pdf
Tender Documents • 10.11 MB
Download all tender documents and submit your bid