Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.8 CrAccepted-Finance | ₹61.8 Cr | L1 | Accepted-Finance 1STLOWEST |
| 2 | L2₹64.3 CrRejected-Finance A 3 338 SECTOR 8 ROHINI DELHI 110085 | NORTH WEST | DELHI | 110085 | ₹64.3 Cr | L2 | Rejected-Finance 2NDLOWEST |
| 3 | L3₹65.3 CrRejected-Finance | ₹65.3 Cr | L3 | Rejected-Finance 3RDLOWEST |
Tender Value
₹47.6 Cr
EMD Value
₹57.6 L
Closing Date
5 Mar 2026, 5:00 pmClosed
Chief Electrical Engineer
5th Floor,CSC,Vidhyut Bhavan
Work of conversion of overhead LT line to underground cable in Sankhali Municipality area, in the jurisdiction of Section Office Sankhali under Sub Division II(R ) Sankhali
2026_ED_27894_1
Tender 33(2025-26)
Open Tender
Electrical Works
365 days
sankhali
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,500
₹57.6 L
Yes
5th Floor,CSC,Vidhyut Bhavan
6 May 2026
24 Feb 2026
6 Mar 2026
24 Feb 2026
5 Mar 2026
27 Feb 2026
26 Feb 2026
Cost of Material
Supply XLPE cable Single core 300 sq.mm unarmoured
Supply of XLPE cable armoured 3 ½ C X 300 sq.mm 1.1 KV Grade
Supply of XLPE cable armoured 3 ½ C X 185 sq.mm 1.1 KV Grade
Supply of XLPE cable armoured 3 ½ C X 95 sq.mm 1.1 KV Grade
Supply of XLPE cable armoured 4 C X 16 sq.mm 1.1 KV Grade
Supply of XLPE cable armoured 4 C X 10 sq.mm 1.1 KV Grade
Supplyof XLPE cable armoured 2 C X 6 sq.mm 1.1 KV Grade
Supply of 415 V Straight through joint 3.5 core X 50 -95SQMM
Supply of 415 V Straight through joint 3.5 core X 150-300SQMM
Supply 6-way, TP&N, 3 phase, 415V, 2 nos. of 315Amps incomings and 6nos.of 200Amps outgoing rating type suitable for outdoor installation, made out of CRCA sheet with PU painted complete with all accsesories and HDGI mounting channels. (6 Way Feeder Pillar)
Supply of 3 phase, 415V, 2nos of 200Amps incoming 3 TPN MCCBs and fitted with 12 Nos. 63 Amps SP, MCBs, 24nos. 32Amps SP, MCBs, 12 Nos.16 Amps SP, MCBs Distribution Service Pillar suitable for outdoor installation ,of CRCA sheet with PU painted complete with all accesories and HDGI mounting channel (48 way Distribution Service Pillar).
Supply of 3 phase and N, 415V, 200Amps MCCB'S incoming,3 phase and N,415V 200 Amps outgoing. 12 nos. 32Amps SP MCBs, 12 nos 16A,SP, SP,MCBs Distribution service Pillar suitable for Outdoor installation of CRCA sheet with PU painted complete with all accesories and HDGI mounting channel (24 way Distribution Service Pillar).
Supply of Street light Service pillar made out of CRCA sheet with PU painted complete with TPN incoming and outgoing MCCB'S , TP contactors,Electronic /Digital /mechanical Timer , connectors etc.complete (street light Pillar)
Supply of Outdoor, LV Main Switchboard for 200KVA Transformer centre made of CRCA sheet with PU painted and complete with all accsesories metering and HDGI mounting channels.
Supply of LV switch board suitable for 400KVA transformer incuding foundation erection,comissioning inclusive of 1600a ACB for incomer and 4nos of 400A MCCB for outgoing feeders with separate compartment for metering arragment and energy meter including foundation
Supply of underground cable protective cover as per specification as given below: PCC precast cable protective cover of size 480mmx 250mmx 50mm casted by confined mold vibratory cast of concrete mix M30, having strength of 30N/mm2 at 28 days. The concrete slab shall be machine made using semi- dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mmx 250mmx 50mm. (+/-2mm) and the concrete grade shall he M30 adhering to 15 456: 2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.
Supplyof 11KV/433V, 200 KVA outdoor type oil immersed aluminium wound Level II Distribution transformer.
Supply erection, testing and commissioning of 400Kva 11/0.433KV delta star,copper wound, oil cooled outdoor type distribution transformer including plinth foundation and terminal boxes at both LV and HV sides.
Removing and Re-Erection of 11KV/433V, 200 KVA Distribution transformer.
Removing of 11KV/433V, 100 KVA Distribution transformer.
Removing and re-erection of Metering Unit sutaible for Distribution Transformer.
Supply of Enamelled danger board.
Supply of Class B HDGI pipe of diameter 50 mm dia.
Supply of Class B HDGI pipe of diameter 100 mm dia.
Supply of RCC Hum pipewith collars of diameter 150 mm dia. For road crossing
Supply of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith Batonite complete with brick masonary.
Supply of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
Supply of GI Flat 25 x 5 mm.
Supply of 8 Mtrs Octoganal Tapered H.D.G.I pole made out of 4 m.m. thick plate and heavy provision for cable entry, having weight not less than 97kg. 4 Nos of J type M24x 750mm long foundation bolts of grade EN 8
Supply of 6 Mtrs Octoganal Tapered H.D.G.I pole made out of 4 m.m. thick plate and heavy provision for cable entry, having weight not less than 97kg. 4 Nos of J type M24x 750mm long foundation bolts of grade EN 8
Supply of 1.5 mts long singal arm brackets HDGI,3.25mm thick for mounting of outer diameter 40mm.
Supply of 1.5 mts long double arm brackets HDGI,3.25mm thick for mounting of outer diameter 40mm.
Supply 1.5 mts long four arm brackets HDGI,3.25mm thick for mounting of outer diameter 40mm.
Supply of LED lights ( 80 Watt )
Supply of LED lights ( 50 Watt )
Removing of old 9.00 mts. Long RCC pole/rail pole
Removing of old 7.5 mts Long RCC pole
Removing of LT Shackle insulators with metal parts
Removing of LT pin insulators with GI pin
Removing of GI 4 pin LT cross arm
Removing of GI 2 pin LT cross arm
Removing of AA ANT conductor
Removing of AA GNAT conductor
Removing of GOAB Switch
Removing of H.G.FUSE UNIT
Removing of Distribution box
Removing of Structure material
Removal of 30 Watts LED Fixtures
Cable Rasing Channel (75X40X5) For Transformer HT Side,structural material
copper bus-Bar Box for service connection to building 3phase 4 way 100A
Al. 300 sq.mm Lugs
Al. 185 sq.mm Lugs
Al. 150 sq.mm Lugs
Al. 95 sq.mm Lugs
Al. 70 sq.mm Lugs
Al. 50 sq.mm Lugs
Copper cable of size 3 core 1.5sq mm for LED fixtures.
CIVIL estimate-I
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) All works upto plinth level
Centering & shuttering including Strutting, Propping & removal of forms for: Foundations, Footings, Bases for columns
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
12mm cement plaster 1:4 (1 cement : 4 coarse sand)
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
Supplying of laterite stone soling of size 150-200 mm size and murrum having P.I. Value not more than 6 and laying including packing with smaller stones and consolidation with power road roller including spreading, watering and consolidation of binding material etc.(Measurements shall be considered on finished item) .
Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint. In R.S. joists, channels, angles, tees
Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint. In flats of all sizes
Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
Painting three or more coats of arcyllic exterior paints of approved brand and manufacture (such as weather shield, APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete
Providing and fixing G.I. chain link mesh 6.35cm x 6.35 cm x 10 gauge (2.5” x 2.5” x 10 gauge) fixed with angle iron posts and struts by G.I. or M.S. staples at 20cms apart with welding with the iron posts (placed at 3 meters centre to centre) including providing barbed wire stiffeners (shall weigh 9.33 kg. per 100 meters minimum) at top and bottom with barbed wire stiffers by binding wires at 50cms centre to centre complete as per the direction of the Engineer – in – charge (angle iron posts struts, earthwork and concrete for fencing posts and struts to be paid separately)
Supply and spreading of 40 mm/20 mm of basaltic stone aggregates in the swichyard.
Providing and fixing prefabricated compound gate of G.I. pipes 40 – 50 mm dia (medium) with 12mm M.S. square bars of G.I. pipes grill work as per drawing including providing & fixing locking arrangements, pintals, hold fast embedded in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 granitic or basaltic aggreate 20mm nominal size) including applying priming coat with ready mixed red lead paint and painting 2 or more coats with superior ready mixed paint of approved brand and manufacture in all shades as per direction complete.
CARRIAGE OF MATERIALS (A) Lime,building rubbish, manure sludge, moorum excavated rock (B) By mechanical transport including loading, unloading and stacking (ii) Earth (upto 5km)
Civil estimate-II
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) All works upto plinth level
Centering & shuttering including Strutting, Propping & removal of forms for: Foundations, Footings, Bases for columns
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
12mm cement plaster 1:4 (1 cement : 4 coarse sand)
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
Supplying of laterite stone soling of size 150-200 mm size and murrum having P.I. Value not more than 6 and laying including packing with smaller stones and consolidation with power road roller including spreading, watering and consolidation of binding material etc.(Measurements shall be considered on finished item) .
Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint. In R.S. joists, channels, angles, tees
Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint. In flats of all sizes
Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
Painting three or more coats of arcyllic exterior paints of approved brand and manufacture (such as weather shield, APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete
Providing and fixing G.I. chain link mesh 6.35cm x 6.35 cm x 10 gauge (2.5” x 2.5” x 10 gauge) fixed with angle iron posts and struts by G.I. or M.S. staples at 20cms apart with welding with the iron posts (placed at 3 meters centre to centre) including providing barbed wire stiffeners (shall weigh 9.33 kg. per 100 meters minimum) at top and bottom with barbed wire stiffers by binding wires at 50cms centre to centre complete as per the direction of the Engineer – in – charge (angle iron posts struts, earthwork and concrete for fencing posts and struts to be paid separately)
Supply and spreading of 40 mm/20 mm of basaltic stone aggregates in the swichyard.
Providing and fixing prefabricated compound gate of G.I. pipes 40 – 50 mm dia (medium) with 12mm M.S. square bars of G.I. pipes grill work as per drawing including providing & fixing locking arrangements, pintals, hold fast embedded in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 granitic or basaltic aggreate 20mm nominal size) including applying priming coat with ready mixed red lead paint and painting 2 or more coats with superior ready mixed paint of approved brand and manufacture in all shades as per direction complete.
CARRIAGE OF MATERIALS (A) Lime,building rubbish, manure sludge, moorum excavated rock (B) By mechanical transport including loading, unloading and stacking (ii) Earth (upto 5km)
Civil estimate-III
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) All works upto plinth level
Centering & shuttering including Strutting, Propping & removal of forms for: Foundations, Footings, Bases for columns
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
12mm cement plaster 1:4 (1 cement : 4 coarse sand)
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
Supplying of laterite stone soling of size 150-200 mm size and murrum having P.I. Value not more than 6 and laying including packing with smaller stones and consolidation with power road roller including spreading, watering and consolidation of binding material etc.(Measurements shall be considered on finished item) .
Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint. In R.S. joists, channels, angles, tees
Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint. In flats of all sizes
Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
Painting three or more coats of arcyllic exterior paints of approved brand and manufacture (such as weather shield, APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete
Providing and fixing G.I. chain link mesh 6.35cm x 6.35 cm x 10 gauge (2.5” x 2.5” x 10 gauge) fixed with angle iron posts and struts by G.I. or M.S. staples at 20cms apart with welding with the iron posts (placed at 3 meters centre to centre) including providing barbed wire stiffeners (shall weigh 9.33 kg. per 100 meters minimum) at top and bottom with barbed wire stiffers by binding wires at 50cms centre to centre complete as per the direction of the Engineer – in – charge (angle iron posts struts, earthwork and concrete for fencing posts and struts to be paid separately)
Supply and spreading of 40 mm/20 mm of basaltic stone aggregates in the swichyard.
Providing and fixing prefabricated compound gate of G.I. pipes 40 – 50 mm dia (medium) with 12mm M.S. square bars of G.I. pipes grill work as per drawing including providing & fixing locking arrangements, pintals, hold fast embedded in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 granitic or basaltic aggreate 20mm nominal size) including applying priming coat with ready mixed red lead paint and painting 2 or more coats with superior ready mixed paint of approved brand and manufacture in all shades as per direction complete.
CARRIAGE OF MATERIALS (A) Lime,building rubbish, manure sludge, moorum excavated rock (B) By mechanical transport including loading, unloading and stacking (ii) Earth (upto 5km)
Cost of Erection
Supply and Erection of XLPE cable Single core 300 sq.mm unarmoured
Supply and Erection of XLPE cable armoured 3 ½ C X 300 sq.mm 1.1 KV Grade
Supply and Erection of XLPE cable armoured 3 ½ C X 185 sq.mm 1.1 KV Grade
Supply and Erection of XLPE cable armoured 3 ½ C X 95 sq.mm 1.1 KV Grade
Supply and Erection of XLPE cable armoured 4 C X 16 sq.mm 1.1 KV Grade
Supply and Erection of XLPE cable armoured 4 C X 10 sq.mm 1.1 KV Grade
Supply and Erection of XLPE cable armoured 2 C X 6 sq.mm 1.1 KV Grade
Supply and Erection of 415 V Straight through joint 3.5 core X 50 -95SQMM
Supply and Erection of 415 V Straight through joint 3.5 core X 150-300SQMM
Supply and erection 6-way, TP&N, 3 phase, 415V, 2 nos. of 315Amps incomings and 6nos.of 200Amps outgoing rating type suitable for outdoor installation, made out of CRCA sheet with PU painted complete with all accsesories and HDGI mounting channels. (6 Way Feeder Pillar)
Supply and erection of 3 phase, 415V, 2nos of 200Amps incoming 3 TPN MCCBs and fitted with 12 Nos. 63 Amps SP, MCBs, 24nos. 32Amps SP, MCBs, 12 Nos.16 Amps SP, MCBs Distribution Service Pillar suitable for outdoor installation ,of CRCA sheet with PU painted complete with all accesories and HDGI mounting channel (48 way Distribution Service Pillar).
Supply and erection of 3 phase and N, 415V, 200Amps MCCB'S incoming,3 phase and N,415V 200 Amps outgoing. 12 nos. 32Amps SP MCBs, 12 nos 16A,SP, SP,MCBs Distribution service Pillar suitable for Outdoor installation of CRCA sheet with PU painted complete with all accesories and HDGI mounting channel (24 way Distribution Service Pillar).
Supply and erection of Street light Service pillar made out of CRCA sheet with PU painted complete with TPN incoming and outgoing MCCB'S , TP contactors,Electronic /Digital /mechanical Timer , connectors etc.complete (street light Pillar)
Supply and Erection of Outdoor, LV Main Switchboard for 200KVA Transformer centre made of CRCA sheet with PU painted and complete with all accsesories metering and HDGI mounting channels.
Supply and erection of LV switch board suitable for 400KVA transformer incuding foundation erection,comissioning inclusive of 1600a ACB for incomer and 4nos of 400A MCCB for outgoing feeders with separate compartment for metering arragment and energy meter including foundation
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : a) All kinds of soil
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b) All types of Ordinary rock including all types of laterite rock, blasting prohibited
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. a) Sand (Deduct for LT cable)
Supply and laying of underground cable protective cover as per specification as given below: PCC precast cable protective cover of size 480mmx 250mmx 50mm casted by confined mold vibratory cast of concrete mix M30, having strength of 30N/mm2 at 28 days. The concrete slab shall be machine made using semi- dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mmx 250mmx 50mm. (+/-2mm) and the concrete grade shall he M30 adhering to 15 456: 2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.
Supply,Testing and Erection of 11KV/433V, 200 KVA outdoor type oil immersed aluminium wound Level II Distribution transformer.
Supply erection, testing and commissioning of 400Kva 11/0.433KV delta star,copper wound, oil cooled outdoor type distribution transformer including plinth foundation and terminal boxes at both LV and HV sides.
Removing and Re-Erection of 11KV/433V, 200 KVA Distribution transformer.
Removing of 11KV/433V, 100 KVA Distribution transformer.
Removing and re-erection of Metering Unit sutaible for Distribution Transformer.
Supply and Erection of Enamelled danger board.
Supply and laying of Class B HDGI pipe of diameter 50 mm dia.
Supply and laying of Class B HDGI pipe of diameter 100 mm dia.
Supply and laying of RCC Hum pipewith collars of diameter 150 mm dia. For road crossing
Supply and erection of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith Batonite complete with brick masonary.
Supply and erection of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
Supply and erection of GI Flat 25 x 5 mm.
Supply and erection of 8 Mtrs Octoganal Tapered H.D.G.I pole made out of 4 m.m. thick plate and heavy provision for cable entry, having weight not less than 97kg. 4 Nos of J type M24x 750mm long foundation bolts of grade EN 8
Supply and erection of 6 Mtrs Octoganal Tapered H.D.G.I pole made out of 4 m.m. thick plate and heavy provision for cable entry, having weight not less than 97kg. 4 Nos of J type M24x 750mm long foundation bolts of grade EN 8
Supply and erection of LED lights ( 80 Watt )
Supply and erection of LED lights ( 50 Watt )
Removing of old 9.00 mts. Long RCC pole/rail pole
Removing of old 7.5 mts Long RCC pole
Removing of LT Shackle insulators with metal parts
Removing of LT pin insulators with GI pin
Removing of GI 4 pin LT cross arm
Removing of GI 2 pin LT cross arm
Removing of AA ANT conductor
Removing of AA GNAT conductor
Removing of GOAB Switch
Removing of H.G.FUSE UNIT
Removing of Distribution box
Removing of Structure material
Removal of 30 Watts LED Fixtures
Cable Rasing Channel (75X40X5) For Transformer HT Side,structural material
copper bus-Bar Box for service connection to building 3phase 4 way 100A
Al. 300 sq.mm Lugs
Al. 185 sq.mm Lugs
Al. 150 sq.mm Lugs
Al. 95 sq.mm Lugs
Al. 70 sq.mm Lugs
Al. 50 sq.mm Lugs
Copper cable of size 3 core 1.5sq mm for LED fixtures.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 21.51 MB
Tendernotice_2.pdf
PDF • 3.26 MB
Tendernotice_3.pdf
PDF • 7.80 MB
BOQ_28340.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid