Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L1 | Accepted-AOC Ok | |
| 2 | L2₹36.2 L+₹2.4 L (7.00%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹37.5 L+₹3.7 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹38.7 L+₹4.9 L (14.6%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹42.4 L+₹8.6 L (25.4%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
29 Aug 2022, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR/ REPLACEMENT AND MAINTENANCE OF CENTRAL AC PLANT AIR HANDLING UNIT COOLING TOWER AND CONNECTED MISCELLANEOUS E/M WORK AT CGDA UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
2022_MES_539162_1
GE/BH-44/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category c(i)
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹99,000
Yes
22 Nov 2022
25 Jul 2022
31 Aug 2022
25 Jul 2022
29 Aug 2022
10 Aug 2022
Amount
M&L MS pipe 40 mm bore heavy grade with all fittings laid in floors or fixed to walls and ceiling etc including PUF insulation and aluminium cladding including taking out/ down of existing pipe complete all as specified and directed by Engr-in-Charge.
All as per item No. 1.00 here-in-before but size of pipe 50mm dia.
All as per item No. 1.00 here-in-before but size of pipe 100mm dia.
All as per item No. 1.00 here-in-before but size of pipe 200mm dia.
All as per item No. 1.00 here-in-before but size of pipe 250mm dia.
S&F in repair POT stainer size 250-300mm dia of Iron body flanged ends with stainless steel strainer, existing rusting pipe cutting with nut bolt etc complete all as specified & directed. Make- Valson/ Sant/ Kartar/ Zoloto
S&F in repairs, cast Iron butterfly valve of 50 mm bore, ISI marked, PN - 1.6 pressure grade, having Nitrile/ EPDM rubber lining, SS stem, CS/ SS disc. Lever operated type, with hand wheel including all jointing material i.e, nut, bolt, washer, packing material etc, duly insulated, complete all as specified & directed.
All as per item No. 7.00 but bore size of 40 mm.
All as per item No. 7.00 but bore size of 200 mm.
All as per item No. 7.00 but bore size of 250 mm.
All as per item No. 7.00 but bore size of 100 mm.
S&F in repairs Poly-F Plus PB classical Belts of size B-82. Make- Fenner/ Dunlop or conforming to IS as approved by GE complete all as specified & directed.
All as per item No.12.00 but size B-116.
All as per item No.12.00 but size B-124.
All as per item No. 12.00 but size B-146.
M&L for dismantling of existing Air Handling Unit of any capacity, cleaning, servicing, overhauling to all component of AHU, with and including cleaning of heating & cooling coil with caustic soda solution, including welding/ brazing, wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages, fabrication of bottom GI tray of existing size with drain pane made out of 16 gauge thick GI Sheets duly painted with bituminous paint over interior surface of tray, re-assembling all the dismantled components to its original position using new nut, bolt, washer and other packing material etc, with and including testing, commissioning of Air handling Unit at optimum efficiency, complete all as specified and as directed.
M&L for applying one coat of synthetic enamelled spray paint of existing colour on steel/iron surfaces of pipes, LT panel boards, Pump Set, Steel Iron Pipe complete plant with and incl preparing of surface by scratching/ removing rust, dust and old paints etc with wire brush, emery paper, grinder etc and making surfaces smooth for achieving better grip between surface and primer, complete all as specified and directed.
S&F in replacement of Pressure gauge dial type range between 0 to 10 kg/cm2 with siphon assembly with on/ off knob including necessary welding cutting complete all as specified and as directed.
S&F in replacement of industrial type mercury thermometer complete all as specified and directed.
S&F in replacement of unserviceable 2/3 way modulating motorized valve including actuator, Thermostat, LED Display with temperature display, GI globe body, Brass seating, SS-304 spindle, Telflon gland, with linear movement actuator 24 V AC input supply, 0-10V input signal with modulating thermostate & transformer of size 40mm complete all as specified and as directed.
All as per item No. 20.00 but of size 50mm.
Taking Down of unserviceable Copper Coil with aluminium fins 4 Rows Deep of size 1016x2790 mm, for Existing Air Handling unit including all welding, cutting and other machine works including re-assembling all component with new coil and testing the AHU for satisfactory operation, complete all as specified & directed.
S&F Copper Coil with aluminium fins with 4 Rows Deep of size 1016x2652 mm for Existing Air Handling unit including all necessary connected items as per existing sample complete all as specified & directed.
S&F Copper Coil with aluminium fins with 4 Rows Deep of size 762x1330mm for Existing Air Handling unit including all necessary connected items as per existing sample complete all as specified & directed.
Supply, fixing and laying, in replacement of GI duct fabricated from 24 Gauge GI Sheet of any dimension/cross-section with and including all necessary fixing arrangement and support to roof and connected accessories i. e. nut, bolts, fastener, flat iron strip, clamps etc and taking down of old duct alongwith accessories, complete all as specified & directed.
Supply, fixing and laying, in replacement of GI duct fabricated from 22 Guage GI Sheet of any dimension/cross-section with and including all necessary fixing arrangement and support to roof and connected accessories i. e. nut, bolts, fastener, flat iron strip, clamps etc and taking down of old duct alongwith accessories, complete all as specified & directed.
M&L for thermal insulation on new / existing ducts and plenum chamber, comprise of preparation of surface and fixing of new cross linked closed cell polythene, plane, fire retardant insulation of 19 mm thick nitrile rubber insulation with aluminium foil of the duct having a tow stable K value of 0.027-0.029 Kcal/hr/m at 0-23°C with minimum density of 33 Kg/cum, fire retardant self extinguishing on dripping, good ozone resistance, including fixing the insulation to the duct surface with help of adhesive paste and closing the gap with self adhesive tape of 3mm thick, complete all as specified & directed.
M&L for superior quality canvas cloth with Zip, having depth not more than 75 cm with GI frame suitable to connect both AHU and duct including taking down of old material all as per directed.
S&F in repair pre filter having HDPE media with GI frame & filter as per the existing size of (610x610x50)mm Make : Athlete/ Tanacity/ Purulater/ Spectrum
All as per item No. 29.00 but size 610x305x50mm.
All as per item No. 29.00 but size 305x305x50mm.
S&F in repair with anchor fastener angle iron, MS flat to support duct with angle iron, flats, nut bolts washers etc. Necessary welding work involved is also deemed to be included in quoted rate include cutting fabrication welding of angle iron/ MS Flat, repair to RCC wall, cost of anchor fastener etc complete all as specified and as directed.
M&L for taking out Cooling Tower Motor 10HP Capacity 720 rpm 3 phase 415 volt opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enamelled copper winding of suitable size including, bearing insulating materials, varnishing, drying, replacement of both driven end. non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by Engr-in-Charge. Note: The quoted rates are including for loading & unloading with to and fro transportation from site to workshop and vice versa.
S&F in repair 10HP, 720 rpm 3 phase 415 volt 10HP Cooling tower electric motor complete all as specified & directed.
M&L for dismantling AHU induction electric motor from AHU base plate inside and arranging the necessary adjusting from fan belt, and then repairing /servicing AHU Fan Motor of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enamelled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed. Note: The quoated rates are including for loading & unloading with to and fro transportation from site to workshop and vice versa.
15 HP AHU fan motor, 1450 RPM, HX+160MLE4 Make- ABB
12.5 HP AHU fan motor, 1455 RPM, HX+160MLB4 Make- ABB
20 HP AHU fan motor, 1450 RPM, HX+160MLE4 Make- ABB
10 HP AHU fan motor, 1450 RPM, HX+132MLE4 Make- ABB
7.5 HP AHU fan motor, 1454 RPM, HX+132MLE4 Make- ABB
M&L for rewinding of electric motor 2 HP, 415 volts, single/three phase, using Super enamelled copper winding wire of gauges equal to or more than existing including replacement of sheet 'E' class insulation and sleeve Including the following jobs:- (a) Reassembling the motor & refixing. (b) Cleaning washing ball bearing with kerosene Oil, greasing with new grease of make Castrol Refixing to its original position testing and Commission complete all as specified and Directed by Engr-in-Charge.
M&L for rewinding of electric motor 1.5 HP, 415 volts, single phase, using Super enamelled copper winding wire of gauges equal to or more than existing. Including Replacement of sheet 'E' class insulation and sleeve Including the following jobs:- (a) Reassembling the motor & refixing. (b) Cleaning washing ball bearing with kerosene Oil, greasing with new grease of make Castrol Refixing to its original position testing and Commission complete all as specified and Directed by Engr-in-Charge.
S&F in replacement, Installation, Testing and commissioning of FRP Induced draft counter flow top discharge type Cooling Tower (Rectangular) of total capacity 225 TR water flow 900 USGPM (3375 LPM) complete with water distribution by PVC spray header, branch pipes & non clogging splash cups. FRP basin , Virgin PVC fillings both edge folded, Direct driven balanced Aerodynamic Type Axial Propeller Fan with 750 RPM speed, weather proof TEFC, IP-55, Flange mounted, extended shaft motor, suction screen, make up & quick fill arrangement, over flow & drain connection, float valve, suitable steel ladder etc.& Confirming to standard specification complete all as specified & directed.
M&L for descaling, servicing, repair of cooling tower of cap 225 TR to AC plant of any make and type including dismantling of cooling tower for removing of top cover and fills, replacement of unserviceable nozzles/ sprinkle, rusted nuts, bolts, studs , washers etc and cleaning bottom tank to remove mud and dust complete all as specified and directed. Note:- Spare parts required to be replaced shall be measured and paid separately.
S&F in repair float valve assembly of any size as required in cooling tower complete all as specified and directed.
S&F in repair PVC spray assembly / Nozzels of any size in cooling tower as required complete all as specified and directed.
S&F in repair fan blade assembly of cooling tower of cooling tower 225TR capacity as per existing assembly including dismantling old unserviceable blades complete all as specified and directed.
S&F in repair PVC Fills complete all as specified and directed.
S&F in repair Spray Header for 225TR Cooling tower complete all as specified and directed.
S&F in replacement MCCB 415 Volts 50 Hz, Three Pole, 100 Amps capacity 25 kA with thermal release range upto 63 Amps complete all as specified & directed.
S&F in replacement MCCB 415 Volts 50 Hz, Three Pole, 160 Amps capacity 25 KA, with thermal release range upto 63 Amps complete all as specified & directed.
S&F in replacement Next Generation Indicator Lamp (R, Y, B led type) as required at site. Make: L&T/Siemens/ ABB
S&F in replacement Start/ stop Button for Starter Panels as required at site. Make: L&T/ Havells/ Crompton
S&F in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 9-15A. Model MN2 complete all as specified & directed. Make- Havells/ L&T/ HPL/ Legrand
S&F in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 14-23A. Model MN2 complete all as specified & directed. Make- Havells/ L&T/ HPL/ Legrand
S&F in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 20-33A. Model MN2 complete all as specified & directed. Make- Havells/ L&T/ HPL/ Legrand
S&F in replacement Power Contactor type MNX of size Fr1, suitable for existing starter panel. Model MNX 12 complete all as specified & directed.
S&F in replacement Power Contactor type MNX of size Fr1, suitable for existing starter panel. Model MNX 25 complete all as specified & directed.
S&F in replacement Power Contactor type MNX of size Fr1, suitable for existing starter panel. Model MNX 32 complete all as specified & directed.
S&F in replacement Power Contactor type MNX of size Fr1, suitable for existing starter panel. Model MNX 18 complete all as specified & directed.
Supply, Laying Jointing and testing of under electric cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor of size 4 core, 10 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed for the following:-
All as per item No. 56.00 here-in-above but for Cable size 4 core 16 Sqmm
All as per item No. 56.00 here-in-above but for Cable size 4 core 25 Sqmm
All as per item No. 56.00 here-in-above but for Cable size 3.5 core 70 Sqmm
All as per item No. 56.00 here-in-above but for Cable size 3.5 core 95 Sqmm
Dismantling of main electrical LT panel and Air conditioning LT panel and refixing of above panel in M.S structure height upto 1 mtr and make functional of electrical panel by reconnection of electrical wire, earthing strip connection etc. as required
S&F Mild steel frame work as in foundation below existing main LT Panel and main AC electrical panel for raising foundation height of existing panel upto 1 mtr including painting new MS work with 2 coat of synthetic enamel paint over and including one coat of red oxide paint including preparation of surface all as specified as directed. Note: Raising/ Lifting of existing electrical panel and provision of PCC for foundation work shall deemed to included in quoted rate.
Flint India
M/s Birja Nand
RUCHIKA ENGG.WORKS
SANJEEV ENTERPRISES
Vishal Traders
M/S Rohit Enterprises
J.P. Enterprises
Saini Enterprises
Shiv Enterprises
New Era Engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .