Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 248 1 CHHEDIPURWA STATION ROAD BEHIND GURU NANAK SCHOOL GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Reject |
| 4 | Rejected-Technical | Rejected-Technical Reject |
Tender Value
₹48.9 L
EMD Value
₹48,900
Closing Date
16 May 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC GONDA
EDC GONDA
127/EDC(G)/2023-24
2024_MVVNL_923784_3
NVS-125-128/EDC(G)/2023-24
Open Tender
Electrical Works
Item Rate
90 days
EDC GONDA
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
SE EDC GONDA
₹48,900
Yes
EDC GONDA
22 May 2024
1 May 2024
17 May 2024
1 May 2024
16 May 2024
1 May 2024
4 May 2024
Amount
All these below items/materials from S.N. 1.01 to 1.17 will be given and errected by the contractor on his own cost as per estimate/Resspo Norms.
F- Bracket
CLAMP FOR TOP, DROPPER AND T-OFF
BATTERY SET 24 volt
LT CLAMP
LT SHACKLE INSULTER
M.S. NUT & BOLT
11 V TYPE X-ARM HOLDING CLAMP
33 KV V TYPE X-ARM HOLDING CLAMP
Guarding Angle Holding Clamp
Stone Pad
Substation Angle Bolt 12'' Long
EYE HOOK
G.I. Pipe 6" Dia
DROPPER ANGLE (L/A)
SUSPENSION Clamp
DEAD END CLAMP
STAY INSULATOR
Loading, Unloading and safe cartage of the following materials (S.N. 2.01 to 2.41) from Electricity Store Centre, Gonda to the work site/dump site (Distance up to 70 km)
PCC Pole 8.5 METER
PCC Pole 9.00 METER
ST POLE 11 METER
25 KVA T/F
63 KVA T/F
100 KVA T/F
250 KVA T/F
ABC CABLE 1x16/ 1x25
ABC CABLE 3×50
ABC CABLE 3×95
ABC CABLE 3×120
ACSR Weasel Conductor
ACSR Dog Conductor
11 KV V-Type X-Arm
33 KV V-TYPE X-ARM
TOP CHANNEL
DROPER CHANNEL
SUB STATION BASE
T-Off Channel
PIN INSULATER WITH PIN
DISC INSULATER WITH FITTING
33 KV POLYMERIC PIN INSULATOR WITH PIN
EARTHING COMPLETE
STAY SET COMPLETE
11 KV XLPE CABLE 3 × 300
33 KV XLPE CABLE 3 × 300
11 KV JOINTING KIT I/D FOR 3 × 300
11 KV JOINTING KIT O/D FOR 3 × 300
33 KV JOINTING KIT O/D FOR 3 × 300
O.D. Cable box for 11 kv XLPE cable 3x300 sqmm
G.I. Wire 10 SWG
Stay Wire
Guarding Angle
DISTRIBUTION BOX 3 PHASE WITH HOLDING CLAMP
33 KV LINE ISOLATOR
33 KV FUSE SET
33 KV Circuit Brakers
33 KV CT 200/100/1-1-1A OUT DOOR
33 KV Transformer Control Pannel For Single Feeder
LIGHTING ARRESTOR
Other material
Erection of single PCC/ST Poles (8.5/9/11 Mtr Long) for 11 KV/L.T. line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site (All decentralize material shall be given by the contractor on his own cost.)
Erection of sectional double pole sectional PCC/STP pole (8.5/9/11 mtr long) alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. (All decentralize material shall be given by the contractor on his own cost.)
Earthing of pole.
Erection and Grouting of stay sets alongwith complete fittings. Cement, Sand & Brick ballast provided by the contractor at his own cost.
Grouting of Poles with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely.All required materials provided by the contractor at his own cost.
Construction of 11/0.4 KV S/S for following capacity of T/F with mounting and fitting of T/F on plinth/double pole with proper fitting of all acessories and connecting with all circuit including earthing of T/F fitting with all accessories.
25 KVA T/F
63 KVA T/F
100 KVA T/F
250 KVA T/F
Dismounting of following capacity T/F and Loading, Unloading and safe cartage of the following materials from the work site/dump site to Electricity Store Centre, Gonda (Distance up to 70 km)
10/16 KVA T/F
25 KVA T/F
63 KVA T/F
100 KVA T/F
Laying, Stringing & Sagging of ABC Cable up to proper sag for the following size cable as per estimate/resspo norms
ABC CABLE 1x16/ 1x25
ABC CABLE 3×50
ABC CABLE 3×95
ABC CABLE 3×120
Laying Stringing sagging & Binding of All size XLPE cable wher is required as per estimate/Resspo norms.
11 KV XLPE CABLE 3 × 300
33 KV XLPE CABLE 3 × 300
Laying, stringing, sagging & binding of conductors of 11 KV in 3 phase, 3 wire line with jumpering (where as required)
Installtion/Errection/Laying/stringing of the following items as per estimate/resspo norms.
33/11 KV different size Jointing kit
DISTRIBUTION BOX 3 PHASE WITH HOLDING CLAMP
33 KV LINE ISOLATOR
33 KV FUSE SET
33 KV Circuit Brakers
33 KV CT 200/100/1-1-1A OUT DOOR
33 KV Transformer Control Pannel For Single Feeder
LIGHTING ARRESTOR
O.D. Cable box for 11 kv XLPE cable 3x300 sqmm
PIN INSULATER WITH PIN
DISC INSULATER WITH FITTING
33 KV POLYMERIC PIN INSULATOR WITH PIN
G.I. Pipe 6" Dia
BORE TYPE DELTA EARTHING depth 40 feet for control room with GI strip as per Estimate/Resspo Norms. (All the required material shall be given by contractor on his own cost.)
CONSTRUCTION OF PLINTH WITH FENCING as per Estimate/Resspo Norms. (All the required material shall be given by contractor on his own cost.)
Cutting of tree branches for cleaning route of 11 KV/LT line at the work site (25 mtr.= 1 Job)
Carrage of scrap/conductor from site to store
Dismentaling old material
Dismentaling old line
Guarding of line
S.R. Infraconstruction Pvt Ltd
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .