Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 CrAccepted-AOC | ₹20.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹20.6 CrRejected-Finance | ₹20.6 Cr | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹23.7 CrRejected-Finance | ₹23.7 Cr | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹25.2 CrRejected-Finance | ₹25.2 Cr | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹25.5 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹25.5 Cr | L5 | Rejected-Finance Other than L1 |
Tender Value
₹19.4 Cr
EMD Value
₹12.9 L
Closing Date
4 Jan 2022, 6:00 pmClosed
Chief Engineer Pune Zone Dakshin Kaman Marg Camp
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
CONSTRUCTION OF NEW TRAINING BLOCK AT DEOLALI
2021_MES_485485_1
84487/E8
Open Tender
Civil Works
630 days
Deolali
Class SS Category a(i)
Refer NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE Deolali
₹12.9 L
Yes
2 Feb 2022
1 Nov 2021
6 Jan 2022
1 Nov 2021
4 Jan 2022
21 Dec 2021
8 Nov 2021 - 25 Nov 2021
Amount
SCH 'A PART-I: BUILDING/STRUCTURES Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Construction of Block of “New Training block” for FOG (consisting of Block ‘A’, ‘B’ & ‘C’) including Stilt floor (parking for 60 Motor cycle and 15 cars) complete all as shown in drawing and as specified.
NOTES:
(a) In construction of New Training block (item No. 1.10 of Sch ‘A’ Part I of BOQ), “Green Building Norms” shall be adhered to achieve minimum “3 Star GRIHA rating” as per advice/direction of Consultant and GE. In this connection refer Notes under the heading “ADDITIONAL REQUIREMENTS AS PER GRIHA-III’ on ‘Schedule of Finishes’ drawing No. CEPZ/2021/DEO/05 Sheet 25R/35, Note No. 27 on srl page No. 35(R) and Appendix 'E' on srl page Nos 256 to 261 of tender document.
(b) For fixing of roof mounted type ‘Solar Photo Voltak Modules’ on roof top of Block ‘C’, Reinforcement bars of the columns are to projected beyond the roof slab in the portion of Block ‘C’ as per location shown in drawing No. CEPZ/2021/DEO/05 sheet 35/35. However cost of fixing arrangement (apart from projecting reinforcement bars) shall be measured and paid under ‘Provisional Sum’ as per manufacturer’s instruction/direction of consultant/GE.
Construction of Block of “Sentry Post” complete all as shown in drawing nos CEPZ/2021/DEO/06 sheet 1/1 and CEPZ/2021/DEO/STR/06 sheet 1/1 and as specified.
Construction of "Septic tank for 150 users" complete all as shown on drawing No. CEPZ/88/TD/19M sheet 1/1 and as specified.
Construction of "Soakage well for 150 users" of size 2.4m dia and 6.0 metre depth complete all as shown on drawing No. CEPZ/2019/TD/03 Sheet 1/2 & 2/2 and as specified.
NOTE: Schedule ‘A’ Part II to XII tems which are Prepriced by MES, Bidders shall insert their lumpsum amount in the Green coloured field under Col-7 only.
Total amount of Sch 'A' Part-II (Internal Water Supply)
Total amount of Sch ‘A’ Part III (Internal Electirc Supply)
Total amount of Sch ‘A’ Part IV (Covered shed for Path)
Total amount of Sch ‘A’ Part V (Road, Path, Culverts and Hard Standing for Car parking)
Total amount of Sch ‘A’ Part VI (Area Drainage)
Total amount of Sch 'A' Part-VII (Sewage Disposal)
Total amount of Sch 'A' Part-VIII (Compound wall)
Total amount of Sch ‘A’ Part IX (External Water Supply)
Total amount of Sch ‘A’ Part X (External Electrification)
Total amount of Sch ‘A’ Part XI (Lightening Protection)
Total amount of Sch ‘A’ Part XII (Site Clearance, Excavation & Earthwork)
NOTE: Schedule ‘A’ Part II to XII tems which are not Prepriced by MES, Bidders shall insert their rate in Column-7 only and the Estimated rate indicated as "0.0" are for that purpose..
SCHEDULE 'A' PART-XIII (MISC B/R, E/M WORKS AND SOLAR PV PLANT)
S&F two way bib cock with wall flange quarter turn (Low-flow) 15 mm dia. Make- Jaguar Model No KUP-35041PMGE or equivalentmodel in makes as per Appendix 'C' complete all as specified and directed.
S&F Pillar Cock (Low-flow) 15 mm dia. Make- Jaguar Model No KUP-35001PMG or equivalentmodel in makes as per Appendix 'C' complete all as specified and directed
S&F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) Make- Jaguar model No ALD-579 or equivalentmodel in makes as per Appendix 'C' complete all as specified and directed.
S&F Angular Stop Cock 15 mm bore of pipe with Wall Flange chromium plated Stop valves Make- Jaguar model No KUP-35053PM or equivalentmodel in makes as per Appendix 'C' complete all as specified and directed.
S&F Urinal valve auto closing system 15 mm bore pipe chromium plated Make- Jaguar model NoPRS-CHR-077 or equivalentmodel in makes as per Appendix 'C' complete all as specified and directed.
S&F Modular type 25/32 Amp SP MCB conforming to IS- 60898: 2002 complete all as specified in IS 732: 2019 and directed. (Make: Legrand Mylnc Cat. Part No. 6759 74 or equivalent model of L&T or ABB).
S&F Modular type 3 pin 25/32 Amp socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed. (Make: Legrand Ekinox³ Cat. Part No. 5734 66 or equivalent model of L&T or ABB).
S&F Modular type 1 module RJ 11 telephone socket with shutter complete all as specified and directed. (Make: Legrand Ekinox³ Cat. Part No. 5734 26 or equivalent model of L&T or ABB).
S&F Factory made screwless, dust proof cover plates of 12 module having superior finish, rounded corners, and solid strength supported by plastic frame behind with flexible wall alignment, horizontal adjustment facility complete all as specified and directed. (Make: Legrand Arteor Cat-Part No. 5757 70 or equivalent model of L&T or ABB).
S&F Factory made screwless, dust proof cover plates of 18 module having superior finish, rounded corners, and solid strength supported by plastic frame behind with flexible wall alignment, horizontal adjustment facility complete all as specified and directed. (Make: Legrand Arteor Cat-Part No. 5757 90 or equivalent model of L&T or ABB).
S&F Factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure of 8 module having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates complete all as specified and directed. (Make: Legrand Arteor Cat-Part No. 6890 42 or equivalent model of L&T or ABB).
S&F Factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure of 12 module having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates complete all as specified and directed. (Make: Legrand Arteor Cat-Part No. 6890 11 or equivalent model of L&T or ABB).
S&F Factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure of 18 module having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates complete all as specified and directed. (Make: Legrand Arteor Cat-Part No. 6890 12 or equivalent model of L&T or ABB).
S&F Floor box made of powder coated CRCA sheet, adjustable 3 compartments (264 mm x 264 mm), heihgt 86 mm complete with accessories all as specifed and directed. (Make: Legrand Arteor Cat-Part No. 6896 38 or equivalent model of L&T or ABB).
M&L Sigle compartment raceway made of GI of size 50 mm x 38 mm (W x H) complete with accessories all as specified and directed. (Make: Legrand Arteor Cat-Part No. 6895 00 or equivalent model of L&T or ABB)
S&F Pop-up type flush mounting box, equipped with push and slide locking system, 6 (2 x 3) modules, matt aluminium finis brushed brass complete with accessories all as specified and directed. (Make:- Legrand Arteor Cat-Part No. 0540 12 or equivalent model of L&T or ABB)
S&F Vertical triple pole & neutral, double door DB, 12 way, metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 250 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed (Make: Legrand, Schneider, L & T).
S&F Vertical triple pole & neutral, double door DB, 8 way, metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 250 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed (Make: Legrand, Schneider, L & T).
S&F Vertical triple pole & neutral, double door DB, 6 way, metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 250 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed (Make: Legrand, Schneider, L & T).
S&F Vertical triple pole & neutral, double door DB, 4 way, metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 250 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed (Make: Legrand, Schneider, L & T).
Note for item No. 13.17 to 13.20 : FP MCCB and SP/TP MCBs shall be measured and paid seperately.
S&F Moulded case circuit breaker (MCCB) FP; 63-100 Amp, 25 KA, 415 Volts, 50 Hz, in single frame following size with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 1.5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% Icu = 16 kA as per IEC 60947-2 complete all as specified and directed. (Make: Schneider, Legrand, L & T)
S & F suspended LED of 38/40 W capable of delivering 3900 lumen, having PC diffuser, luminous efficacy of > 100 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. (Make: Philips Cat-Part No. SP680P LED39S 6500 PSU WH L120 S1 or equivalent model of Havells Cat-Part No. DESTELLO50LP /S36WLED840SPMMAWH or Wipro Cat-Part No. LE11-491-XXX-57-XX).
S&F 20 W surface / wall mounted LED batten capable of delivering 2100 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. (Make: Philips Cat-Part No. BN 021C LED20S- PSU CW GR S2 or equivalent model of Havells Cat-Part No. LHEXAPP7IN1W020 or Wipro Cat-Part No. LL20-281-XXX-65AL1).
S & F 25 W recessed mounted square shape 2' X 2' LED panel capable of delivering 3000 lumen, 6500K having high efficiency long life LED package in integral module with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, high transmittance polystyrene opal diffuser, housed in white powder coated pressure die-cast aluminium heat sink having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. (Make: Philips Cat-Part No.RC 380 B LED30S-6500 G4 L60W60 PSU/PSD OD or equivalent model of Havells Cat-Part No. VENUSNEOHE2X2R28WLED857PIRSENSOR or Wipro Cat-Part No. CRCO10R038HP57G1).
S&F 10 W surface / wall mounted LED batten capable of delivering 1150 lumen, having PC diffuser, luminous efficacy of > 110 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. (Make: Philips Cat-Part No.BN 021 LED10S- 6500 PSU GR S1 or equivalent model of Havells Cat-Part No. LHEXACP7FN1W010 or Wipro Cat-Part No. LL20-111-XXX-65-NE).
S&F 11/14 W surface mounted round shape LED downlight capable of delivering 1200 lumen. having minimum luminous efficiency > 100 lumen/W, CCT 6500K, CRI > 80, high quality polycarbonate diffuser, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection complete all as specified and directed. (Make: Philips Cat-Part No. SM250C LED12S- 6500 PSU WH or equivalent model of Havells Cat-Part No. LHEAABP7IL1W012 or Wipro Cat-Part No. LD80-101-XXX-60-SM).
S&F 26 W street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 2600 lumen/W, 5700K, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete in all respect as specified and directed. (Make: Philips BRP042 LED 26 CW MR S1 PSU GR or equivalent model of Havells Cat-Part No. ENDURAPEARLSL25W LED757 SASYTOPCMP or Wipro Cat-Part No. LR02-291-XXX-57-XX).
Supply and laying in trenches , in any length centrifugally cast (spun) ductile iron (DI) pressure pipes, nominal dia meter 100mm class K-9 classification, suitable for push on type rubber gasket joints testing complete all as specified and as directed.
Supply and fixing sluice valve,100 mm complete, PN 1.6 all as specified and directed.
Supply and laying in trenches , in any length centrifugally cast (spun) ductile iron (DI) pressure pipes, nominal dia meter 150mm class K-9 classification, suitable for push on type rubber gasket joints testing complete all as specified and as directed.
M & L Construction of brick masonry valve pit chamber 90 cm x 90 cm and 90 cm deep (internal size) with 15 cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore, chamber constructed with 23cm thick brick wall using old size fly ash bricks built in cement and sand mortar 1:4 and finished with 15 mm thick internal plaster including top of masonry, plaster finished with a floating coat of neat cement, 2.0 mm thick MS sheet cover with 40mm x 40mm x 6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25mmx6mm flat iron hold fasts, hinges, handles, locking arrangements and applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including necessary excavation and earth work in any type of soil and disposal of surplus soil to a distance of n. exc. 50 m etc. complete all as per CEPZ TD drawing and all as specified and directed.
Supply, installation,testing and commissioning new LT feeder piller box “CPRI Approved” cubicle type,with angle & frame, free standing, floor mounted, outdoor, weather proof type, pedstral mounted feeder pillar working on 440V 3-phase, 50 Hz, AC supply with and 4 Nos stepped aluminium bus bars for looping & branch connection system, weather proof dust proof and vermin proof with canopy on top 3mm thick CRCA sheet steel enclosure painted as per the 7 tank process and painted for outdoor weather proof IP-55 protection installation, the bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust proof bus bar chamber shall be provided with better ventilation facility in the form of louvers for better heat dissipation as per specification with and including the following components complete all as specified and as directed.
(a) Incomer: ACB 4 Pole,415V, with (Manual drawout type) of 630Amps overload protection, no-volt release with necessary CT’s meter and Cable box- 01 No. (Make: Legrand/L&T/ABB/Seimens)
(b) Outgoing : 4 Pole MCCB having 400 Amp, 36kA -01 Nos Ics= 100%Icu, MCCB 4 PoLe 250 Amps, 36KA,-02 Nos Ics=100% Icu, MCCB TP 32 Amps with breaking Capacity 16 KA-01, Ics=100%Icu (Make: Legrand/L&T/ABB/Seimens), Contractor of three phase 20 Amps, 415 V, 20 Amps with 0-24 hrs timer swich 230 V (Make: Legrand/L&T/ABB/Seimens).
Supply, installation, testing and commissioning new LT feeder pillar box “CPRI Approved” cubicle type, with angle iron frame, free standing, floor mounted, outdoor, weather proof type, pedestal mounted feeder pillar working on 440 Volts 3-phase, 50 Hz, AC supply with and 4 Nos stepped aluminium bus bars for looping & branch connection system, weather proof dust proof and vermin proof with canopy on top, 3mm thick CRCA sheet steel enclosure painted as per the 7- tank process and painted for outdoor, weather proof IP-55 protection installation, the bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust proof, bus bar chamber shall be provided with better ventilation facility in the form of louvers for better heat dissipation as per specification with and including the following components complete all as specified and as directed.
(a) Incomer : MCCB 4 Pole, 400A, beaking cap 36 kA -01 Nos . Ics=100% Icu Make: Legrand/L&T/ABB/Seimens.
(b) Outgoing : 4 Pole MCCB having 100Amp, 25kA -06 Nos Ics= 100% Icu Make: Legrand/L&T/ABB/Siemens
Supply, installation, testing and commissioning new LT feeder pillar box “CPRI Approved” cubicle type, with angle iron frame, free standing, floor mounted, outdoor, weather proof type, pedestal mounted feeder pillar working on 440V 3-phase, 50 Hz, AC supply with and 4 Nos stepped aluminium bus bars for looping & branch connection system, weather proof dust proof and vermin proof with canopy on top 3mm thick CRCA sheet steel enclosure painted as per the 7 tank process and painted for outdoor weather proof IP-55 protection installation, the bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust proof bus bar chamber shall be provided with better ventilation facility in the form of louvers for better heat dissipation as per specification with and including the following components complete all as specified and as directed.
(a) Incomer : MCCB 4 Pole, 250A, beaking cap 36 kA -01 Nos . Ics=100% Icu Make: Legrand/L&T/ABB/Seimens.
(b) Outgoing : 4 Pole MCCB having 100Amp, 25kA -05 Nos Ics= 100% Icu. Make: Legrand/L&T/ABB/Siemens
S&F Endura Pearls plus of LED street light made of pressure die cast housing with toughed glass and individual high power 70W 5700K LEDs with secondary optical, IP-66 protection and impact of IK 07 Make:- Havells cat pat : L70W LED 757SASYTOPC or equivalent model in Wipro/ Philips as approved by GE.
M&L Making underground boring (Manually /Mechanically) through existing bituminous road/PCC/Floor along cross section of the road for laying of GI tubing for encasing of cable all as specified and directed by site.
M&L Bracket made out of GI tubing 40 mm dia, light grade 1.5 metre long and MS clamps - 2 Nos made our of 50 mm x 5 mm flat iron and fixing and assembling with and including MS nuts, bolts 75 mm long 12 mm dia - 4 Nos and flat washers (3 mm thick) including preperation of steel surfaces and painting with two coars of aluminium paint over one coat of red oxide to MS clamps and bracket etc. complete all as specified and directed.
Supply & fix Thermo plastic street light Sintex box of size 280 x 170x 130 mm Cat No GS-JB-2817 top Hinged (or equivalent make of National) with 4 way connector mounted on epoxy insulators for looping the cable for 3 phase and 1 neutral fixed on pole with the help of MS nut bolts and MS clamps-1 No of size 40 mm x 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box.
Supply and fix New generation, Post-top, energy saving environmental friendly, long life aesthetically designed with symmetrical light distribution, Spun aluminium landscape luminaire with IP-65 25LED as light source all as per Philips Cat Part No. BGP 161 LED 2500/ NW PSU 220-240V 7043IN or of equivalent make as per Appx 'C'.
S&F 10 KVA Online UPS having three phase input and three phase output power KW CAPACITY= 80% OF rated KVA, voltage= 400 V AC (-/+)1%, Power factor 0.8 Lag to unity within the specified KW rating, It should have a electronic protection such as input over/under voltage, battery over/under voltage, overload, short circuit, output over/under voltage, over temperature, over heat, battery should be 42 AH Capacity=20 Nos it should be lead acid sealed maintenance free with minimum 30 minutes backing including Racks & links. Makes as per Appendix 'C'.
Supply and install AC 2TR hi wall split units, inverter type indoor/outdoor complete with cordless remote control unit and in built air ionizer and plasma filter for better indoor air quality with minimum 4star rating and EER 3.2 of capacity 2 TR with copper condenser and cooling coil.
Supply and install AC 1.5 TR hi wall split units, inverter type indoor/outdoor complete with cordless remote control unit and in built air ionizer and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR with copper condenser and cooling coil.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx. storage capacity is of 150 liters and nominal cooling capacity is 150 Ltrs. (Make:- Voltas / Blue Star / Usha).
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx. storage capacity is of 80 liters and nominal cooling capacity is 40 Ltrs. Makes:- Voltas / Blue Star / Usha)
Supply install testing and commissioning Silent type Diesel Engine Generating set 415 volt, 320 KVA, 3 phase 4 wire, 0.8 power factor, 50 Hz, 1500 RPM self excited self regulated brushless AC generator installed including acoustic enclosure suitable for ambient condition at Deolali (Nasik) and confirming to condition under IS 4722, 10001/10002, 13364, BS 5514/2613/5000 consisting of the following :-
(A). Alternator :- Standard design alternator rated at 320 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000, IS: 13364 and shall be in position to generate supply with frequency regulation within + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722.
i) Insulation class - 'H'
ii) Temperature rise Class - 'H'
iii) Excitation : Self Excited
iv) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5%.
v) Frequency regulation + 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS -10001/10002/ 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-
i) Fly wheel with housing
ii) Cooling system :- Moulded radiator with fan & belts.
(m) Lifting lugs.
iii) Cooling Water pump :
iv) Exhaust System :- Exhaust System complete with exhaust piping upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.
Exhaust gas turbo charger type
Exhaust manifold
Silencer : Residual type
Bellows
iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governor electronic operated/ (as recommended by OEM) for 1% speed /frequency regulation.
Fuel filters
Fuel hoses
v) Lub oil System :-
Lubricating oil filter
Lubricating oil pump
vi) Air Intake System :-
Air intake Manifold
Air cleaner dry type
vii) Governor electronic / (as recommended by OEM)
viii) Starting System :- Electric Self starter with and including battery charging alternator.
ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and directed.
x) Starter gear ring
Start and stop push button
Ignition key / Switch
xi) Handling and operation : Salient features of accessories shall be as under:
Radiator with blower fan
Corrosion inhibitor coolant
Paper element filters for fuel, lub oil and by pass.
xii) Governor electronic (as recommended by OEM) controlled direct fuel injection system
xiii) Fly wheel housing and fly wheel.
(C) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display.
i) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine.
ii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling.
iii) Accessories :- AVM Pads built or separately mounted to manufacturer base frames as per (as recommended by OEM)
iv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes.
v) Fuel Tank :- Daily service fuel tank (as recommended by OEM) with calibrated level indicating arrangement, stop cock, drain plug, complete on a common base in side the acoustic enclosure.
vi) Rubber Matting of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel shall be provided.
(D) Acoustic Enclosure:- Manufactured by OEM suitable for 320 KVA DG Set.
(i) NAL approved as per CPCB
(ii) It shall be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.
(iii) The generating set batteries and control panel shall be inside the enclosure.
(iv) Fuel tank shall be in side the enclosure.
(v) Construction Details/specification are as follows : -
a) Outer body :- CRCA Sheet of 1.6mm thick.
b) Doors :- CRCA sheet of 1.6 mm thick
c) Sound Insulation :- 100 mm thick rock wool (64kg/Cum)
(vi) The acoustic shall be composite in construction and fully assembled integral unit.
(vii) The batteries shall be placed inside the enclosure beside the DG Set on a suitable insulated plat form.
(viii) The DG Set shall be provided with external Emergency stop push button.
(ix) The enclosure shall be suitably illuminated by CFL/FTL Lamp fittings.
(x) The noise level shall be 75 Db at 1m under free field conditions.
(xi) The acoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade shall be Genset Green. The base frame shall be painted with epoxy based black shade.
(E) AMF Control Panel : Factory fabricated, Cubical type, free standing, floor mounted, AMF Control Panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0 mm thick CRCA Sheet including two coats of powder coated paint over a coat of red oxide primer etc., and comprising of following:
(i) AMF with relay based control circuit, four pole MCCB 630 Amp 415 V 50 KA. for main supply and DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating Engine start, stop three attempt starting facility and failure to start etc.
(iii) Digital frequency meter
(iv) Digital KWH meter
(v) Digital Power Factor meter (-1.0 to +1.0)
(vi) Current Transformers of suitable CT ratio.
(vii) Indicating lamps for supply 'ON' and load 'ON'
(viii) Instrument fuses ( HRC type)
(ix) Push button 01 No each for start, stop, and re-set
(x) Copper bus bar of capacity 1000 Amp for phases and neutral (xi) Bottom gland plate including glands for incoming and outgoing LT cables
(xii) Circuit diagram plate
(xiii) KWH meter Digital type
(xiv) Instrument fuses HRC type
SOLAR PV PLANT Supply, installation, testing and commissioning of Roof Mounted type Solar Photo Voltak Modules minimum rating of 330 Wp,poly Crystalline type,with module efficiency, more than 16.99 % at Standard test conditions with anti reflective coating and anti dust coating confirming to IEC 61215 and IEC 61730 complete including electrical connection and mounting on GI structure frame all as specified and directed. Makes: Waaree, Vikram, Tata solar
NOTES:-
(a) Design for fixing/mounting on roof for roof mounted Solar modules shall be provided by the department through consultant during execution.
(b) However GI structure frame with foundation, fixing arrangements etc. shall be measured and paid separately under Provisional Sum.
Supply, installation, testing and commissioning of 35kW of String Inverter (DC to AC 415 Volt, 35 KW at given load condition) IP 65 out door wall mountaing, with efficiency not less than 97% confirming to IEC 600682-2/vde standards with multifunctional LED indications with alarm and complying the following:- (1) Nominal Voltage-415 V +/-10 % ,3 Ph ,50 Hz (2) Micro Processor /Dsp micro Controller based system (3)Total Hormonics Distrotion <3 % (4)Inverter should be capable of Synchronisation with grid supplyt and DG set supply.complete all as specified and directed by the engineer- in- charge. Makes: FIMER (ABB) , Hitachi.
S&F Outdoor type IP 55, powder coated, 1 In 1 Out LT Panel configuration with 63 A MCB, AC SPD Type 2 complete, minimum Size of Enclosure shall be 400 mm x300 mm x155 mm (IP 55) along with 4 pole MCB 63 Amps, AC Surge Protection Device-3 ph of 40 kA (as per IEC 60364-5-53), 4 Indication Lamp- R, Y, B.,with multi functional meter 3 phase, 415 Volt (Voltage , Current, Power and Energy unit measurement (KWH)), including Copper Busbar with NVR and contactor including connecting lugs and Double compression glands etc complete as specified and directed. Make: Switchgear: Siemens, L&T, Legrand , Schneider, SPD: Citel/ Phoenix/ OBO. (Note:- Rate quoted is inclusive of integration & synchronisation with existing three phase LT panel supply source.)
M&L 1.1 kV grade 4 core 16 mm² Copper Armoured Cable , XLPE insulated armoured cable conforming to IS 7098 (Part 1) all as specified and directed.
M&L 4 Sq mm single core DC copper flexible Solar Multi Stranded Sheathed Cable (Photovoltaic power cables, halogen free, flame retardant, As per EN50618 approval) flexible Solar Cable complete as all specified and directed. Makes : Leoni, Lapp.
M&L DWC HDPE Conduit (Double Walled Corrugated (DWC) HDPE Conduit Pipe 63 mm Outer diameter, 50 mm Inner Diameter ) for DC Cable laying with required accessories like bend, L Connectors Clamps as per site requirement laid on structure / fix on wall with GI support complete all as specified and directed. Make: Tirupati or any reputed Indian Manufacturer as approved by GE
S & F Male & Female pair of MC4 connectors compatible with 4 mm2 DC solar cable. Make: Staubli or any reputed Indian Manufacturer as approved by GE
S & F Copper Strip 20 mm x 3 mm all as specified and directed.
M&L Chemical earthing in any type of strata (hard/loose) with Material/ Backfill compound shall be Highly Conductive Compound, maintenance free. The watering shall be required at the time of its installation only. No re-charging with water, salts or any other chemical shall be required and it shall maintain almost constant earth resistance during its life cycle without manual watering.(Earthing Rod of 19 mm D X 2m Long 250 micron Cu bonded rod with chemical material) with Laying of Earthing copper Strip of 25x3 mm complete all as directed.
M & L Spike type Lightning Arrestor with 3 air terminals, material should be copper coated, air terminal diameter should be greater than 15 mm, size should not less than 01 meter, voltage - 12 kV, frequency 50 Hz, ball diameter should be greater than 40 mm, pipe should be greater than 24 mm and complete with all accessories as specified and directed.
M & L for painting lines, dashes, letters, arrows etc of any width or girth on road pavement (parking etc) providing and applying 2mm thick road marking strips (reflective) of specified shade, colour using hot thermoplastic material fully/semi automatic application machine fitted with profile shoe heater driven by experienced operator on road surface including preperation of new surfaces, cleaning surfaces of all dirt scales, oils, grease and foreign materials all as per manufacturer instructions and traffic diversion arrangement, if required complete all as specified and as directed.
M&L for MS Delenators SVD-3, 1200 mm long, 76.1 mm dia (OD) MS pipe light grade(3.25mm thick) filled with PCC 1:2:4 with HIP 76.1mm around including taking down old delineator . Three strips 50mm width with blue, white, red or any other colour directed by Engineer-in-Charge, HI reflective tape and with MS jali/ mesh 2mm dia aperature 25mmx25mm in pipe shape as guard bar(Mesh having size centre to centre dia 120mm, ht 250mm) mounted on 1.25mm thick MS circular plain sheet and top closed with same circular sheet including necessary excavation and foundation in PCC 1:2:4 size 30cmx30cmx30cm including preperation of steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-In-Charge. Make of delenators : Siddhi Vinayak Enterprises, / Road Safety Mark / 3M / Dark Eye / Alaxius).
S&F informatory reflective sign board with 2mm thick aluminum sheet of size not less than 0.60 Sqm each enclosed with stainless steel frame of section not less than 40x40x1.6mm thick writing of letters on both sides with size of letters not less 10cm in height and 2cm in width and Nos of letters exc 6 Nos but not exc 25 Nos each side with high intensity prismatic reflective tape, including 02 Nos of stainless steel post in each board not less than 50mm dia 1.6 mm thick duly polished for best shine fitted round glove at height of 2.10m above ground level, SS poles shall be embedded in and including necessary excavation and PCC 1:3:6 type C-2 (using 40mm graded aggregates) foundation and coping complete all as specified and directed.
PROVISIONAL SUM Provide Provisional Sum for Solar Panel Module platform and GI structure framework to be provided as per requirement of OEM and as designed by Consultant or as directed by GE at site.
M.R.Mutha Engineers
SHRE GURMUKHDAS CONTRACTOR PVT. LTD.
M/s Gujarat Construction Company
SOOD ASSOCIATES PVT LTD
nhsaluji and associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid