Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.9 LAccepted-AOC FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹66.4 L+₹4.0 L (6.46%)Rejected-Finance MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹67.5 L+₹5.2 L (8.34%)Rejected-Finance | L3 | Rejected-Finance Higher Bidder | |
| 4 | L4₹68.2 L+₹5.8 L (9.33%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L4 | Rejected-Finance Higher Bidder | |
| 5 | L5₹69.6 L+₹7.2 L (11.6%)Rejected-Finance FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L5 | Rejected-Finance Higher Bidder |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
19 Jul 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO JUNIOR SAILORS BLOCK BUILDING Nos P 72 AND P 73 AT INS GOMANTAK UNDER GE GOMANTAK VASCO
2021_MES_453235_1
85426/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE GOMANTAK VASCO
₹1.2 L
Yes
27 Nov 2021
21 Jun 2021
22 Jul 2021
21 Jun 2021
19 Jul 2021
12 Jul 2021
Amount
Schedule 'A' Part I - B/R portion
Demolition of cement concrete in floor and pavings not exceeding 15 cm thickness (below or above ground level complete all as specified and directed.
M&L for 25 mm thick PCC type B-0, 1:2:4 (12.5 mm graded aggregate) as in levelling course in floors complete all as specified and directed.
M & L for screed bed or bedding layer or mortar 20mm thick for laying floor finishes in cement mortar 1:3 complete all as specified and directed.
M & L for 20 -22 mm thick kota stone, machine cut kota stone slab flooring over cement screed base laid in cement mortar, and jointed in neat cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete (mirror polished) complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc., including racking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M&L for rendering cement plaster 15 mm thick in cement mortar 1:6 on fair faces of brick/concrete faces (internal walls) finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering in cement 1 : 4 (10+5)=15mm thickness on brick/cement/stone surfaces and finishes the surface even and smooth without using extra cement including mixing with liquid WPC on top 5 mm thick only complete all as specified and as directed. Note :- Liquid Water proofing compound will be paid separately
M&L for rendering 5mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling complete all as specified and as directed.
Supply only integral liquid water proofing compound of approved make (ISI marked) for addition in cement mortar/concrete complete all as specified and as directed.
M&L for two coats of acrylic emulsion exterior paint (anti fungal painting of approved make) over a coat of acrylic emulsion primer including preparation of new concrete/plastered surface of any description complete all as specified and as directed
M&L for one coat of acrylic emulsion exterior paint (weather proof, anti fungal painting of approved make) including preparation of old treated concrete/plastered surface of any description all as specified and directed
M&L for providing two coats of oil-bound distemper over a coat of alkali-resistant primer on new plastered surfaces including necessary preparation to surfaces complete all as specified and as directed.
M & L for complete removal of existing treatment on walls and applying two coats of oil-bound distemper on old plastered surfaces including necessary preparation to surfaces complete all as specified and as directed
M&L for providing two coats of oil-bound distemper over a coat of alkali-resistant primer on new plastered ceiling surfaces including necessary preparation to surfaces complete all as specified and as directed.
M & L for complete removal of existing treatment on ceiling and applying two coats of oil-bound distemper on old plastered surfaces including necessary preparation to surfaces complete all as specified and as directed
Taking down chowkhats or frames exceeding 1.5 sqm not exceeding 4 sqm each with shutters (without taking off shutters from the frames(,wooden doors) complete all as specified and as directed.
S & F 2nd class hard wood plain solid straight chowkhats frames wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S & F 35 mm thick plain framed panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces complete all as specified and as directed.
S & F gauzed skeleton shutter, 35 mm thick, divided into squares plain chamfered open rebated and prepared to received glass guaze etc, edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) complete all as specified and as directed.
S&F Aluminium alloy anodised wire mesh of size 1.5 mm x 3 mm mesh 20 Gauge thick complete all as specified and as directed.
S & F 150mm Aluminium, anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S & F Extruded anodised aluminium alloy handles, fabricated type, of 150mm long complete all as specified and as directed.
S & F Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed of 300mm long complete all as specified and as directed.
S & F Stainless steel butt hinges, 100mm long, medium weight, complete all as specified and as directed.
S & F Bends straps support or stays for rainwater ventilating pipes including bolts if required, hook and eye, Hold fasts wall ties hooks for hanging fans, plain angle etc complete all as specified and as directed.
M&L for treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkhats, etc., area not exceeding 0.1 sq. m each, all as specified and directed.
M & L for PCC type C-1 1:3:6 (using 20 mm graded aggregate) for filling the holes after inserting the hold fast complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over coat of pink primer complete all as specified and as directed.
Taking down chowkhats or frames not exceeding 1.5 sq.m. each with shutters (without taking off shutters from the frames)( aluminium windows) complete all as specified and as directed.
S&F Powder coated aluminium window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the approved standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S&F Aluminum powder coated deco grill make DG 104 (10 mm thick section ) with frame of section not less than 0.136 kg/rm complete all as specified and as directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 05 sqm in each pane complete all as specified and as directed.
Taking up or down 20mm steel tubing and connections, fixed to wall /floor complete all as specified and as directed.
Supplying and laying of 20 mm dia. CPVC pipes SDR 11 & Plain CPVC SDR 11with all fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Dismantling water tanks and removing to store of capacity exceeding 1000 & not exceeding 2000 ltr.
S & F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, for 2000 ltrs capacity complete all as specified and as directed.
S & F 25 mm dia Ball brass valves, high pressure, with polythene float and fly- nut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
S&F in repair vitreous china wash basin (WHB) , white , flat back , size 550mmx400mm including CI cantilever brackets, 32 mm dia brass Chromium plated waste fittings with long screw shanks and fly nuts , flange end embedded in red lead cement , including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply pipe and supply of taps complete all as specified and as directed.
S&F in repair pillar taps, fancy type with long nosecast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe, high pressure with long screwed shanks and fly-nuts , screwed for iron pipe ISI Marked complete all as specified and as directed.
S & F in repair 15mm chromium plated , fancy type, stop valves / angle cock screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S & F in repair swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) fixed with Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms complete all as specified and as directed.
S & F in repair 15mm bib taps, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F Towel rail 450mm long with and including chromium plated brass screws wooden / plastic cleats min wt 170 gm complete all as specified and as directed.
S&F in repairs CP Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S&F in repairs 15mm size PVC connection with PTMT nuts 450mm length complete all as specified and as directed.
M&L for 75mm thick PCC type C-1, (1:3:6) using 20 mm graded stone aggregate as in plinth protection finished even and smooth using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even & smooth (without using extra lime or cement) with WPC 200ml per bag complete all as specified and as directed. Note WPC will be measured and paid separately all as specified and directed.
Removing of APP treatment from roof surface cleaning of roof tops including removing the existing treatment by brooming down with steel wire brushing scrapping down with steel scrapper and roughening the existing surfaces to receive plaster and Supply & Laying water proofing treatment using 4mm thick APP modified membrane consisting five layer membrane with features as specified, weighing not less than 4.5 kg per Sqmm laid over a coat of cold applied bituminous primer @ 0.20 Kg per sqm by torching the membrane including sealing the over lap while torching with 100mm on length side and 100mm wide side as per manufacturer’s instructions including joints and changes in direction the curved with cement mortar 1:3 mixed with SBR Latex @ 200 Ml/bag of cement cured well before laying of membrane all as per manufacturer instructions and to the satisfaction of Engineer -in-charge including two coats of bituminous aluminium paint Note (i) irrespective of lap the net covered area will only be measured for payment . (ii) The quoted rate is deemed to be inclusive of primer APP membrane & SBR Latex all as specified and directed.
M&L for PCC 1:2:4 type B-0 25 mm aggregate laid on roof floor mixed with WPC finished even and smooth complete all as specified and as directed. Note:WPC will be measured and paid separately.
Schedule 'A' Part II - Internal Electrification
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed
M&L for point wiring complete with 1100 volts grade PVC insulated and unsheathed multi stranded 1.5 Sq mm FR-LSH single core copper conductor cable drawn through and including PVC casing and capping (surface) ISI marked with all accessories, & sunken pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket, regulator etc including 1.5 Sq mm PVC insulated and unsheathed multi stranded copper conductor cable as earth continuity wire all as specified for one light, fan, socket outlet etc and making good disturbed surface of walls and floors to match with existing surfaces complete all as specified and as directed
All as per item No 52 here in before but for One light point controlled by two Nos two way switches.
All as per serial item No 52 here-in-before but one 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
All as per item No 52 above but one 6 pin socket outlet 15 Amps independent/metal plug and socket with cables 4 sq mm size copper PVC insulated cable multi stranded and 4 sqmm cable conductor for earth wire.
S&F Switch piano flush button single pole one way 05 Amps complete all as specified and as directed
S&F Switch socket combination 2 in 1, 3/5 pin, 5 Amp flush type universal complete all as specified and as directed
S&F Switch socket combination 2 in 1, 3/5 pin, 15 Amp flush type universal complete all as specified and as directed
S&F Stepped type electronic fan regulator electronic flush type 300 watt on existing phenolic laminated sheet etc including removal of old complete all as specified and as directed
Taking down carefully existing ceiling fan of any sweep & make, complete with down rod and opening greasing, oiling including replacement of nut bolt, washer, rubber bush, pin replacement of PVC flexible wire not less than 1 m from the ceiling rose to fan complete & re fixing and testing complete all as specified and as directed
S&F 25W 4ft long LED batten light fitting with 2.5 KV voltage surge protection PF >0.9 complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed Note: if 25 W LED T/L fitting not available than next higher wattage will be provided by the contractor without any extra cost
S&F 3-Watt LED bedside light fitting complete all as specified and as directed
S&F in repairs exhaust fan 250 mm sweep plastic body. 230 volts including dismantling of old one and making existing hole in wall suitable as per new fan size complete all as specified and as directed Note: Dismantled exhaust fan shall be deposited in MES store.
M&L for sub main wiring with single core 1100 V grade conforming to relevant IS, PVC insulated unsheathed cables two run of 4 Sq mm multi stranded copper conductor drawn through and including 25 mm wide non metallic PVC casing & capping including all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 4 sq mm copper wire earth continuity conductor connecting to existing main switch board \ distribution board and testing on completion etc including taking down old sub main wiring of any type with conduit/casing and capping and making good disturbed surfaces to match existing one complete all as specified and as directed. Note: Three runs of 4 sqmm cable and one run of PVC casing and capping not less than 25mm width shall be measured as one run.
M&L for sub main wiring (three phase) with single core 1100 V grade conforming to relevant IS, PVC insulated unsheathed cables four runs of 6 Sq mm multi stranded copper conductor drawn through and including 32mm mm wide non metallic PVC casing and capping including all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 6 sqmm copper wire earth continuity conductor connecting to existing main switch board distribution board and testing on completion etc including taking down old sub main wiring of any type with conduit/ casing and capping casing and making good disturbed surfaces to match existing all as specified and directed. Note: five runs of 6 sqmm cable and one run of PVC casing and capping 32mm width shall be measured as one run.
S&F Sheet metal enclosure (DB) for MCCB (Suitable for 160 Amps), vertical type,8 way, triple pole and neutral, 415 volts, double door with 200 Amps rated bus bar with IP 54- IK 09 complete all as specified and as directed
S&F Flush type sheet metal enclosure DB, VTPN, 4 way, 415 volts, IP 54 ,double door with 100 amp rated copper bus bar for each phase,2 No neutral bar, 2 No earth bar including provision for 4 pole MCB as incomer and SP/TP MCB's as outgoing complete all as specified and as directed
S&F MCB TPN, 32 Amp, 415 Volts, 'C' series 10 KA complete all as specified and as directed
S&F MCB TP, 32 Amp, 415 Volts, 'C' series 10 KA complete all as specified and as directed
S&F MCB, single pole & Neutral, 6-32 Amp, 240 Volts, 'C' Curve 10KA complete all as specified and as directed
S&F MCB, single pole, 6-32 Amp, 240 Volts, 'C' Curve 10KA complete all as specified and as directed
M&L for earthing complete with GI steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground S level) with top edge of the plate not less than 1.5m below normal ground level, connected to Gl wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including necessary earth work and excavation of in any type of strata, PCC 1:3:6 type C-2 GI tubing 20 mm dia for watering and 15mm dia Gl tubing for protection of wire etc all as per electrical plate No.3 of SSR part I including connecting to electrical equipments and testing on completion. Note: GI earth wire upto 7.5 RM is included in the unit rate quoted
S&F 50mm GI tubing (light grade) with all fittings, laid in trenches/floors or fixed along with walls /poles complete all as specified and as directed
S & F in ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S & F LED Bldg Security Street light 30W ,IP 65 with 10KV surge protection including suitable size of Gl pipe 1.2 m long bent to required shape, clamps, nut, bolts and making electrical connection to the fitting with suitable size of service wire complete all as specified and as directed.
S&F MCB 4 pole,63 Amps, 415V, C series 10 KA complete all as specified and as directed.
S&F MCCB 160 Amps,415V,4 pole,50 HZ with breaking capacity 16 KA,ICS=100% ICU, thermal magnetic type,with OL*SC protection complete all as specified and as directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .