Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND FOUND REASONABLE | |
| 2 | L2₹43.5 L+₹3.6 L (8.97%)Rejected-AOC 266 UTTAMNAGAR NDA ROAD PUNE 411023 | PUNE | MAHARASHTRA | 411023 | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | L4₹44.0 L+₹4.1 L (10.3%)Rejected-AOC | L4 | Rejected-AOC NOT BEING LOWEST | |
| 4 | L4₹44.6 L+₹4.7 L (11.8%)Rejected-AOC | L4 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹46.8 L
EMD Value
₹93,500
Closing Date
26 Aug 2021, 9:00 amClosed
GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
PROVISION OF LAB FACILITY NAMED SHOCK TUBE AND GAS GUN LABORATORY OF MECH ENGG DEPT BLDG NO P-148 INCLUDING PROVISION OF CERTAIN MINOR WORK FOR AFNET DATA SERVICES AT AIT HANGER MILIT GIRINAGAR PUNE -25
2021_MES_462997_1
GE I R AND D GNR TOKEN 28 OF 2021 2022
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE 411025
PROVISION OF LAB FACILITY NAMED SHOCK TUBE AND GAS GUN LABORATORY OF MECH ENGG DEPT BLDG NO P-148 INCLUDING PROVISION OF CERTAIN MINOR WORK FOR AFNET DATA SERVICES AT AIT HANGER MILIT GIRINAGAR PUNE -25
7 documents required · 7 mandatory
₹500
Yes
GE I R AND D GIRINAGAR PUNE 411025
₹93,500
Yes
13 Mar 2022
27 Jul 2021
28 Aug 2021
27 Jul 2021
26 Aug 2021
13 Aug 2021
27 Jul 2021 - 11 Aug 2021
Amount
BUILDING INCLUDING INTERNAL SERVICES B/R (PART -1) Excavation in trenches not exc 1.50mtr wide and not exc 1.50mtr in depth for foundation etc and getting out in soft / loose soil.
Surface dressing not exceeding 15cm deep in soft/loose soil complete.
Surface excavation n.exc 30cm deep and average 15cm and getting out in soft/loose soil.
Rough excavation not exceeding 1.5m deep and getting out in soft/loose soil complete.
Removing excavated material exc. 1.50Km but n. exc. 5Km and depositing where directed complete.
Spreading and levelling of rough excavated soil in layers not exc. 25cm thick complete.
M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete all as specified and directed.
M&L for cement concrete 1:2:4 Tpe B0 using 12.5mm stone aggregate as in damp proof course 40mm thick complete all as specified and as directed.
M&L for precast cement concrete block masonry with solid blocks of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, exc. 10 cm in width and setting in CM 1:6, complete.
M&L for cement concreate 1:2:4 type B1, using 20mm graded stone aggregate as in coping, bed block including necessary form work and finishes the surfaces even without using extra cement complete all as specified.
Rendering 15 mm thick of fair faces of cement concrete block masonry/concrete surface in CM 1:6 finished even and smooth without using extra cement.
M&L for rendering 15mm thick on precast cement concrete block masonry/concete surface in CM 1:4 finished even and smooth without using extra cement.
M&L for preparation of surfaces and applying 2mm thick wall care putty in two layers on walls/concrete over new or old plaster surfaces internally complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of primer on new surfaces of wall complete.
M&L for two coats of external acrylic (100%) weatherproof emulsion paint Apex Ultima or equivalent complete all as specified and directed over a coat of alkali resistant primer on new plastered surfaces of wall including necessary scaffolding required for painting work, safety measures etc.
M&L for moorum/red bajri filling in floors or pavings, laid in layers not exc. 15cm thick, spread, levelled and rammed including wateriing complete.
M&L for Hardcore of broken stone gauge exc. 63mm but n. exc. 100mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type B1 using 40 mm graded stone aggregate as in sub base.
M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection.
M&L for sand cushioning below paver block.
M & L for machine made Rubber moulded precast conctete interlocking paver block (coloured), Glossy finish pre polished of any shape and size with white cement and pigment confirming to IS 15658-2006 of 60mm thickness M-35 Grade complete all as specified and directed.
M&L for 150mm thick PCC (1:1.5:3) type A-2 using 40mm graded stone aggregate as in flooring finished even and smooth without using extra cement including construction joint at each 1m interval. The Joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 grade & two part sand (by volume) complete all as specified and as directed by Engr-in-charge.
M&L for cement concrete type B1,1:2:4 (20mm graded stone aggregate) as in kerb or mud stop, slightly rounded or champhered on edges complete all as specified and directed.
Returning filling in, well watering ramming in layers not exceeding 15cm thick complete all as directed.
Removal of excavated soil to a distance not exc. 50mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting point complete all as specified.
M&L cement concrete type C 2, 1:3:6 ( 40 mm gde stone aggregate) as in filling and mass concrete.
M&L for mild steel angles as in post and struts in fencing incl cutting tops and shape as directed incl drilling holes, notching for wire etc conforming to Fe-410W (Gde E-250) etc of any description complete all as specified.
Fixing only chain link fencing including line wires, any mesh size and type and type of standards, rails, straining bolts etc including provision of binding wire all as specified.
Supply only MS galvanished chain link fencing with 4 mm dia and size 40 mm x 40 mm including line wires including strain bolts, binding wire etc. all as directed.
S&F round bars 10mm dia ( Fe 410 W gde E 250) and over, cut to length, bent to shape required,including binding and welding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F mild steel flat iron (Fe-410-0 or Fe – 310 –0) as in bands / straps / rails for chain link fencing cut required length including necessary drilling holes for fixing bolts all as specified and directed.
M&L for mild steel bolt factory made with hexagonal or square heads at one end and screw the other to be fitted with washer etc and one hexagonal or square not exc 5cm long end dia neck 11 to 15mm etc complete all specified and directed by Engr-in-charge.
S&F steel work in tubular trusses, cantilever, purlin, post including special shaped washer etc. complete using ERW or induction butt welded square/rectangular pipes including necessary cutting, welding complete all as specified and directed by Engr-in-Charge.
S&F Pre-painted coloured galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding/door to wall, height upto 10mtr from floor level fixed with self tapping screws/'J' hook/nessary welding to iron all as directed by Engr-in-Charge, including necessary arrangement of scaffolding/crane for fixing of sheets complete.
M&L for Two coats of synthetic enamel paint over a coat of red oxide on steel surfaces exc 10 cm width or girth etc.
M&L for Two coats of synthetic enamel paint over a coat of red oxide on new/old steel surfaces not exc 10 cm width or girth etc including preparation of rurfaces complete.
Framed MS work as in doors or gates of angle or other section with gusset plates, rails braces etc, complete door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings also fastening and fixing complete all as directed and complete with locking arrangement.
S&F three track sliding window with 4mm thick tinted glass in two shutter and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperature for mosquito proofing including good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. Series of aluminium section as per Jindal is (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
M&L for mild steel framed work such as grills, gratings etc. with ends of bars shouldered or riveted or gorged into spikes framed guard bars barred to windows, iron door,ladders framed balusters, walk ways, railing, frame work for water tank and similar work conforming to Fe-290 Gde E-165 complete all as specified.
M&L for RCC type A1 (1:1.5:3) using 20mm graded stone aggregate as in foundations,including rafts, footing, plinth beams,bases for column etc.
M&L for RCC type A1 (1:1.5:3) using 20mm graded stone aggregate as in columns, pillars, piers etc.
M&L for RCC type A1 (1:1.5:3) using 20mm graded stone aggregate as in Roof beams, lintels, cantilevers etc.
M&L for RCC A1 (1:1.5:3) in slabs supported on walls, chajja, Roof beam, roofs , canopies, shelves & the like.
M & L for granite 18mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Formwork to side of concrete foundations footings,bases of column,raft and beams ,side and soffits of foundation and plinth beams and similar work and finish fair finished to flat surface.
M&L for form work to side of pillars, posts columns etc.
M&L formwork to soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc.
M&L formwork to soffits of suspended slab such as roof slabs , chajja, floor slabs, shelve, landings and similar works n.exc 200 mm thick (horizontal or sloping).
Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incfluding cranking, bendidng etc and binding with and includidng mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified.
Mild steel TMT bars 5 to 10mm dia as in sturrips cut to length bebt to shap required including cranking, bending etc and bindidng and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified.
S&F Steel rolling shutters thickness of laths 1.25mm MS sheet, with necessary ball bearing, as specified including top cover, anchoring rod, hasp and staple erected in position as indicated but gear operated type with bevel gear box and crank handle, complete all as per directed by Engr-in-Charge.
S&F safety lever locks mild steel with 4 levers for rolling shutters complete.
M&L for 20mm thick machine cut kota stone slab flooring laid over and including 20mm thick screed base in CM 1:6 and jointed in with grey cement to match the shade of the slab including rubbing, cutting and polishing complete including preparation of old surfaces complete all as directed by Engr-in-Charge.
INTERNAL E/M SERVICES ( PART-1) M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including modular cover plates, modular flush boxes and modular frame for mounting for housing the switches, socket outlets, fan regulators etc, all as specified and as directed for the following: - (a) One light point controlled by one way switch.
(b) One 3 pin switch socket outlet point 5 Amps on independent board.
(c) One 3 pin switch socket outlet point 5 Amps on same board with other switch.
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.
S & Fix modular switch, single pole,one way 6 Amps capacity
S & Fix modular switch, single pole, one way 16 Amps capacity
S & Fix modular socket, outlet 2 in 1, 6 Amp capacity
S & Fix modular, socket 6A/16A 2 in1, 16 Amp capacity
S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix LED Batten suitable for mount LED tube rod 1 x 18 watts including necessary electric connections with flexible copper cable from ceiling rose to tube light fitting complete all as specifed and directed by Engineer-in-charge. Make :- Bajaj Cat Part No - BLRB-DB 118 or eqvt in Wipro/Havell/Crompton.
S & Fix LED tube light rod 18 watts with necessary fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make - Bajaj Cat Part No - BLRB 18W LED or eqvt in Wipro/Havell/Crompton.
S & Fix MCCB DB VTPN 4 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going, VTPN DB's 415 volt 3 phase complete with appropriate size copper bus bar and neutral link as required at site and including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e directed by Engr-in charge.Make -: Legrand or eqvt make of ABB/Siemens
S & Fix sheet metal enclosure distribution board SPN 4 way 240 volts, 200 amp busbar rating with IP 43 protection and double door, suitable for mounting MCBs and all as specified and as directed.
S & Fix of MCCB Four pole, 415 volts, 63 Ampere, rupturing capacity 16 KA, complete all as specified and directed.
S & Fix MCB Triple pole and neutral, 415 volts, 6 to 63 Amps, all as specified and as directed.
S & Fix MCB Triple pole, 415 volts, 6 to 63 Amps, all as specified and as directed.
S & Fix MCB single pole, 240 volts, 6 to 40 Amps, all as specified and as directed.
M & L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the surface through and including suitable size of PVC Concealed conduit fixed to walls / roofs / floors / ceiling etc with its accessories all as specified and directed by Engr-in -charge for the following. (a) 4x6 sq mm and 1x6 sq mm as earth wire
S & Fix LAN socket connecter RJ 45 with socket with copper feed modular type all as directed by Eng in Chrage.
S & Fix LAN cable 4 pairs PVC insulated and PVC sheathed all as directed by Engr in Charge
S & Fix Wall mounted fan 400 mm sweep white colour, 230 volts, 55 Watts including fixing arrengenment on wall all as directed by engr in charge. Make- Havells or eqvt in Bajaj / Crompton.
Supply and Laying in trenches LT underground cable ISI marked XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc, laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole,making hole in wall as per requirement at site complete all as directed by Eng-in-charge of following:- (a) 4 core 25 Sqmm
Supply & Laying 40 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement
M &L for GI pipe ''light grade'' for road crossing / on wall / on pole for cable protection of following size:- Make: TATA/JINDAL/ PRAKASH SURYA a) 40 mm dia
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense or any type of soil including forming bottom surface etc.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point.
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less that 1.5 M below normal grouond level connected to GI earth wire 4 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe withand funnel, PCC 1:3:6 Type C-1 chamber with 40mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
MINOR WORK (PART -II) M&L Point wiring complete with 2.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through heavy duty PVC casing capping fixed to walls etc. and including provision of 2.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly including concealed modular flush boxes including modular cover plates with frame mounting for housing the switches, socket outlets etc, all as specified and directed .
S & Fix modular switch single pole, one way 16 Amps capacity
S & Fix modular socket, 6A/16A 2 in1, 16 Amp capacity
S & Fix Single pole and neutral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs.
Supply , installation, testing & commissoning of maintenance free, chemical earthing with pure copper pipe earthing electrode of outer dia 76mm x 6 mtr in length with thickness 3mm and copper strip 50 x 6mm (strip in pipe tupe electrode). The copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KG approx of BFC shall be filled around the copper pipe electrode, including providing FRP pit cover of size 250 mm at top, 330 mm at bottom and 260 mm in height capable to withstand minimum 2 ton driving load. Rate included for testing, commisioning including checking of earth continutiy and earth result complete all as specified and without grid of earthings. Any additional work and material required to achieve the required result is included in the cost. Rate is included for boring of earthing in any type of soil/rock upto 200 mm. Copper strip must be connected with copper pipe electrode and other joints with nut bolt in addition to brazing and all as directed and specified by Engr-in- Charge. Note:- (i) Earth strip for grid network and from top connector of electrode to test point and further connection to AF equipment/ for grid of earthing shall be measured and paid seperately.
S & Fix surge protection device 275V single phase.Make havells model no DHSA2R1N40275 or equivalent.
S & F copper strip 20 x 3mm with saddle and fixing screws etc for roof conduters and down conductors above ground.
S & F Galvanised iron strip 32 x 6mm with saddle and fixing screws etc for roof conduters and down conductors above ground.
S&F Earth strip insulator, material ceramic, Max withstanding temperature 200 Def C,Curent flow each 630 Amp,housing type Procelain, voltage 2000V, Earth insulator ID No.16235167012 for fixing of earth strip of size 20 x 3mm and 32 x 6 .Complete all as directed by Eng-in Charge.
S & Fix of MCB single pole, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed.Make Havells or equivalent.
Supply & fixing air termination,singlr pointed aluminium rod 12mm dia 300mm long all as specified and directed By Engineer-in-Charge
J.G.Goel
Mehta and Co.
sagar construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .