Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.4 L+₹3.7 L (10.2%)Rejected-Finance AT PO DERA COLLIERY TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹48.4 L+₹11.7 L (32.0%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical 86 MAHEWA EAST NAINI PRAYAGRAJ U P | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | - | Rejected-Technical Reject as per NIT Note 1 |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
29 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Provn of certain sanctioned works (REV, LBW and MW) and Spl repair works under GE (East) Allahabad.
2021_MES_453881_1
8479/E8
Open Tender
Civil Works
Item Rate
180 days
Allahabad
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹75,000
Yes
20 Sept 2021
23 Jun 2021
5 Aug 2021
23 Jun 2021
29 Jul 2021
15 Jul 2021
23 Jun 2021 - 30 Jun 2021
60 days
Amount
Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
Cement concrete 1:4:8, type D2 (40mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed.
Preparation of new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 MPa as in roof covering / cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft / loose soil, complete all as specified and directed.
Machine pressed, rubber moulded, coloured, precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-35 Grade, with grey cement and no pigment, laid over and including provision of 25mm thick sand cushioning, complete all as specified and directed. MAKE:- Interlocking paver blocks shall be as approved by GE
Plain cement concrete 1:4:8, type D2 (using 40mm graded stone aggregate), in sub-bases of floors, 75mm thick, complete all as specified and directed.
Providing plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and npt exceeding 1.5 m in depth and getting out in soft / loose soil, complete all as specified and directed.
Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6metre mean radius built in in CM 1:6, complete all as specified and directed.
Hardcore, of broken stone or boulders, of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Cement concrete 1:2:4, type B2 (40mm graded stone aggregate) as in surface channels and drains, complete all as specified and directed.
Cement concrete 1:2:4, type B1 (20mm graded stone aggregate) in base course of floors, 40mm thick, complete all as specified and directed
Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces of walls, finishing the surface even and smooth with out using exta cement, complete all as specified and directed.
Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces of walls, finishing the surface even and smooth with out using exta cement, complete all as specified and directed.
Screed bed or bedding layer of 15mm thick screed bed in CM 1:4, complete all as specified and directed.
Screed bed or bedding layer of 20mm thick screed bed in CM 1:4, complete all as specified and directed.
Glazed coloured ceramic tiles in vertical surface 450mm x 350mm x 7mm / 350mm x 250mm x 7mm thick, laid in vertical surfaces such as skirtings / dado / risers to steps etc., set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed.
Non - skid Ceramic tiles 7 to 8 mm thick, of size 400mm x 400mm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed.
Machine cut Kota stone flooring 20-25mm thick, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including rubbing and polishing, complete all as specified and directed.
Preparation of newly plastered surfaces of walls of any description over 10cm width or girth not otherwise described and applying two coat of cement base paint, complete all as specified and directed.
Returning, filling in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick. complete all as specified and directed.
Removing surplus excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m \above the starting point. complete all as specified and directed.
Structural streel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., using rolled mild steel sections conforming to Fe-410 W (Gde E-250) quality, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 MPa as in roof covering / cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
Coloured, exterior designer tiles, 300mm x 300mm x 10mm thick, laid in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles, laid over and including provision of scrred bed 15mm thick in CM 1:4, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 25mm bore of pipe, complete all as specified and directed.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, 25mm bore, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 15mm bore of pipe, complete all as specified and directed.
Bib taps (fancy type) with chromium plated wall flange, cast copper alloy, chromium plated, two-way with single knob, screwed down, screwed for iron pipe or for brass ferrule and fixed, 15mm bore, complete all as specified and directed. MAKE:- Model No. 0047 of L&K or techno-commercially equivalent model in makes as mentioned in list of makes here-in-after.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 50mm bore of pipe, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 40mm bore of pipe, complete all as specified and directed.
Cutting of existing water pipe line, of size upto 150mm dia GI pipe, in position for insertion of new Tee (with and including provisionof new Tee), complete all as specified and directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, 50mm bore, complete all as specified and directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, 40mm bore, complete all as specified and directed.
Vitreous China urinals, half-stall type, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, including of fixing supply pipe to flushing cistern, trap and 32mm dia waste pipe & waste coupling 32mm dia complete all as specified and directed.
Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms), complete all as specified and directed.
PVC connections 15mm size, of length 300mm, PTMT nuts,, complete all as specified and directed.
PVC connections 15mm size, of length 450mm, PTMT nuts,, complete all as specified and directed.
Vitreous China wash hand basin, with pedestal, size 630mm x 400mm white, including taps, waste pipe, chain and plug and porcelain stopper but including brackets, including cutting for and pinning in ends of brackets or erecting stand, with and including provision of waste coupling of PTMT 32mm dia (half or full threaded) (Minimum weight shall be 45gms), waste pipe 32mm dia PTMT with inlet and outlet screwed for pipe including necessary packing, union and cap, complete all as specified and directed.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, 15mm bore, complete all as specified and directed.
Stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, 15mm bore, complete all as specified and directed.
Vitreous china urinal partition white of size 310x700 mm., complete all as specified and directed.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, fixed in repairs, complete all as specified and directed.
UPVC (SWR) 110 mm bore pipes single socketed ends, in any length with rubber ring joints, fixed to walls or laid in floors or trenches, complete all as specified and directed.
UPVC (SWR) juncton, single 'T' equarl or unequal, suitable for 110 mm bore pipes, jointed with cement solvent or adhesive, complete all as specified and directed.
UPVC (SWR) bends ISI marked of any radius, suitable for 110 mm bore pipes, jointed with cement solvent or adhesive, complete all as specified and directed.
UPVC (SWR) bends ISI marked of any radius suitable for 110 mm bore pipes, jointed with cement solvent or adhesive, with access door, complete all as specified and directed.
UPVC (SWR) 'P' trap, suitable for 125/110mm size, jointed with cement solvent or adhesive, complete all as specified and directed.
Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms), complete all as specified and directed.
Grating doom 100 mm dia with waste hole of PTMT. (Minimum weight 25gms), complete all as specified and directed.
Non - skid Ceramic tiles joint free type 7 to 8 mm thick, of size 400mm x 400mm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including provision of scrred bed or bedding layer of CM 1:6, 15mm thick, complete all as specified and directed.
Glazed coloured ceramic tiles in vertical surface 450mm x 350mm x 7mm / 350mm x 250mm x 7mm thick, laid in vertical surfaces such as skirtings / dado / risers to steps etc., set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including provision of 10mm thick backing coat in CM 1:3, complete all as specified and directed.
Plain, black, mild steel sheeting, 1.00mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and npt exceeding 1.5 m in depth and getting out in hard / dense soil, complete all as specified and directed.
Brickwork with subclass ‘B’ bricks, halfbrick thick, straight or curved on plan exceeding 6metre mean radius built in in CM 1:4, complete all as specified and directed.
Reinforced cement concrete, 1:2:4 type B1 (20mm graded stone aggregate) (nominal mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
Reinforced cement concrete, 1:2:4 type B1 (20mm graded stone aggregate) (nominal mix) as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Mild steel TMT bars 6mm - 10mm dia, as in in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Formwork to rough finished sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed.
Formwork to rough finished sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and directed.
Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of walls, finishing the surface even and smooth with out using exta cement, complete all as specified and directed.
Plain cement concrete 1:3:6, type C2 (using 40mm graded stone aggregate), in floors, 75mm thick, complete all as specified and directed.
Preparation of newly plastered surfaces of ceilings of any description over 10cm width or girth not otherwise described and applying three coat of white wash, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 20mm bore of pipe, complete all as specified and directed.
Rotational moulded HDPE water storage tanks (cylindrical vertical with closed top), 250 litre capacity (ISI embossed), double layered, hoisted and fixed in position all as specified in SSR Part I, including provision of GI nipple for tank, complete all as specified and directed.
Ball valve high pressure PTMT with epoxy coated aluminium rod and high density plastic ball secured for iron pipe of dia 20mm (minimum weight 210 gram), complete all as specified and directed.
Mild steel screw bolts (machine made), 11.00mm to 15.00mm dia of neck, with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 22.5cm but not exceeding 30cm, complete all as specified and directed.
Spreading of natural, clean and dry river sand in trenches for cable protection, complete all as specified and directed. NOTE:- Punned thickness shall only be measured and paid.
Supply and lay burnt clay fly ash bricks class 'B', old size, designation 75, size 230mm x 115mm x 75mm, laid in trenches for cable protection with length of brick equal to width of trench, complete all as specified and directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 10 sq.mm 4 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
GI tubing light grade, galvanised with all fittings including short lengths, fixed to ceilings and walls or laid under road crossing as cable protection pipe with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 15mm bore of pipe, complete all as specified and directed.
Cutting of existing bituminous road or PCC hardstanding upto 1200mm deep and 250mm wide for laying of pipe line (40mm dia), including making good of the top surface upto 150mm depth to match with the existing using PCC 1:2:4 type B1 (20mm graded stone aggregate), complete all as specified and directed. NOTE:- GI pipe light grade 40mm dia shall be measured and paid under respective items of this Schedule.
Demolition of Cement Concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removing rubbish off the MD premises, complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and directed.
Second class hard-wood in scantlings, clean sawn timber fixed, complete all as specified and directed.
Asbestos cement, corrugated or semi-corrugated sheets, 6mm thick in roofs, walls et in roofs, walls etc, fixed with L-type or J-type or cranked hook bolts, complete all as specified and directed.
Asbestos cement, corrugated or semi-corrugated sheets, 6mm thick in roofs, walls et in roofs, walls etc, fixed with L-type or J-type or cranked hook bolts, but except sheets, complete all as specified and directed.
Asbestos cement two piece adjustable plain wing ridge 6mm thick, fixed with L-type or J-type or cranked hook bolts, complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Plain cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate), 25mm thick as in sub base of floors, finished even and smooth without using extra cement, complete all as specified and directed.
Machine cut kota stone slab (table rubbed and polished) flooring 20-25mm thick laid over and including provision of cement screed base 15mm thick in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed.
Non - skid Ceramic tiles joint free type, 7 to 8 mm thick, of size 400mm x 400mm, laid in vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including provision of backing coat of 10mm thick in CM 1:4, complete all as specified and directed.
Glazed coloured ceramic tiles joint free type in vertical surface 450mm x 300mm x 7mm thick, laid in vertical surfaces such as skirtings / dado / risers to steps etc., set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including provision of 10mm thick backing coat in CM 1:4, complete all as specified and directed.
Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of walls, finishing the surface even and smooth with out using exta cement, complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5sq.m but not exceeding 4sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Taking down shutters of any description not exceeding 1sq. m each, complete all as specified and directed.
Providing PCC 1:3:6 type C1 (20mm graded stone aggregate) as in bed blocks for fixing of holdfasts, complete all as specified and directed.
Second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified and directed.
Second class hardwood glazed and skeleton shutters, 32mm thick, open rebated and prepared to receive glass, gauze, etc, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed.
Second class hardwood glazed and skeleton shutters for windows, 30mm thick, open rebated and prepared to receive glass, gauze, etc, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b); supplied and fitted to chowkats, complete all as specified and directed.
Flush shutters, 32mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, 250mm long, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section and fixed, 150mm long, complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel, and fixed, 100mm long, complete all as specified and directed.
Aluminium handles, cast type, anodised, 150mm long, complete all as specified and directed.
Factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, fixed in repairs, complete all as specified and directed.
Factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with out glazing bars, dovetailed or welded, fixed in repairs, complete all as specified and directed.
Galvanised mild steel wire cloth, 0.48mm nominal dia of wire and average width of aperture 1.5mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
Sheet glass, 3mm thick, ordinary quality and glazing in squares not exceeding 0.5 sq. m in each pane with oil putty, complete all as specified and directed.
Mild steel (miscellaneous work) as in bands, straps, hold fasts; wall ties; hooks for hanging fans; plain angle cleats or securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and directed.
Provision of false ceiling, consisting of E-Board of make : Everest or techno-commercially equivalent in Armstrong / Sanitgobain, desing "lake and hill" of sie 605mm x 605mm x 4mm thick, white prelaminated set, embossed reinforced designer ceiling board tiles of approved texzture at all height laid on hot dipped galvanised iron imposed grid with 24mm wide T-section (white powder coated); the framework shall comprises of main runner made of 0.33mm thick GS sheet and of size 24mm x 32mm x 300mm and spaced at 1200mm (maximum) centre-to-centre, securely fixed to structural soffits with hangers of 1.60mm dia GI wire, to be fixed with approved rawl plugs, adjusters and screws; flush fitting of 1200mm long cross tee (double section) to be interlocked between main runners at 600mm centre-to-centre to form 1200mm x 1600mnm modules, cross tee shall be longer than 600mm, to be supported independently. 600mm x 600mm doubles to be formed by fittings 600mm long cross tee centrally between 1200mm corss tee; perimeter wall angle shall be made out of 0.45mm thick GS sheet of size 19mm x 19mm and 300mm long of white colour, all as per manufacturers specifications, complete all as specified and directed.
Preparation of wood or wood based new surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Preparation of old plastered surfaces of walls of any description over 10cm width or girth not otherwise described and applying two coat of white wash, complete all as specified and directed.
Preparation of newly plastered surfaces of walls of any description over 10cm width or girth not otherwise described and applying three coat of white wash, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. to match with the existing, complete all as specified and directed.
Taking down main switches, DBs, cut-outs of any type alongwith existing boards and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Taking down carefully submain wiring of any type and size including earth wire on wooden batten / surface conduits / casing and caping etc., and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FR copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.00mm thick factory made pressed steel terminal box of required size, duly painted both inside and outside with two coat of black bituminous paint over a coat of red oxide primer, duly covered with 2.8mm thick prelaminated sheet cover of colour as approved and duly concealed in walls for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FR copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light point controlled by one 5 Amp one-way switch, complete all as specified and directed. NOTE:- (i) The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
All as per Sl. Item No. 116.00 here-in-before but for 3-pin 5Amp socket outlet point on independent board
All as per Sl. Item No. 116.00 here-in-before but for one 3-pin socket oiutlet 5 Amp on same board alongwith other switches
Point wiring complete with 2.50 sq.mm PVC insulated unsheathed multi-stranded FR copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.00mm thick factory made pressed steel terminal box of required size, duly painted both inside and outside with two coat of black bituminous paint over a coat of red oxide primer, duly covered with 2.8mm thick prelaminated sheet cover of colour as approved and duly concealed in walls for housing switches, sockets, regulators etc., including 2.50 sq.mm PVC insulated unsheathed multi-stranded FR copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for security light fittings and for 3-pin 15Amp socket, complete all as specified and directed. NOTE:- (i) The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing.
Switch piano, flush type single pole, one-way 5 Amp, ISI marked, complete all as specified and directed.
Switch piano, flush type single pole, one-way 15/16 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
Ceiling rose three terminal, 65x25mm PVC / polycarbonate insulated body, surface bakelite type AC 50 Hz 230V, complete all as specified and directed.
MCB DB, SP, double door, epoxy powder coated, factory made 8-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCB SPN 32 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, complete all as specified and directed.
MCB SP 6 - 32 Amp, 240 Volt, 'B' curve, 10KA breaking capacity, complete all as specified and directed.
Security LED light fitting 40Watt, IP-65 protection pressure die-cast aluminium body, heat resistant glass, including driver and making necessary electric connection with 2.5sq.mm twin core copper wire 1.50metre long complete fixed to and including provision of GI pipe light grade bracket 1.20metre long and bent to shape required and fixed with suitable FI 40mm x 6mm clamp two Nos with nuts, bolts and washers as required, complete all as specified and directed. MAKE:- Cat No. LR02-451-XXX57-G1 of Wipro or Cat No. BRLEP40W LED WH of Bajaj or Cat No. ASTRAL LSTS 40CDL of Philips or techno-commercially equivalent model in CG
LED wall mounted tube light fitting, 1x18W, LED 6000K, decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. LHEXBHP7IN1W018 of Havells or techno-commercially equivalent model in Philips / CG
Exhaust fan 230 Volt 50 Hz single phase AC supply, 380 mm sweep with louvers complete with metal body powder coated with protective steel bird guard on wall of building with and including provision of 3 core 1.5 Sq.mm flexible cable from ceiling rose to exhaust fan including writing MES number on exhaust fan motor using synthetic enamel paint of approved tint, including making necessary holes in masonry walls and making good the disturbed surfaces to match with the existing, complete all as specified and directed. MAKE:- Model: Ventil Air-DS of Havells or techno-commercially equivalent model in Almonard / Bajaj / Usha / Khaitan.
Socket outlet 2 in 1, 5 pin, 5A, flush type, ISI marked, complete all as specified and directed.
Switch piano, flush type single pole, one-way 15/16 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
Stepped (rotary) type electronic fan regulator (suitable for 1200mm / 1400mm sweep ceiling fan) flush type duly fixed on the existing phenolic laminated sheet etc. as required, 240V, humming free, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
LED bulk head light fitting, 10W, 600lumen, enclosed in polycarbonate body, weather proof, fixture with co-extruded polycarbonate body, environmental friendly, energy efficient, complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. HEXAFT10WLED857SSY MBOPC of Havells or techno-commercial equivalent model in Crompton / Wipro / Philips
Sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of rigid PVC conduit 25mm dia including conduit accessories and connecting terminal ends to DB's including providing 1 run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC casing / caping shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Lamp holder, PVC polycarbonate body with back plate suitable for batten fittings, complete all as specified and directed.
LED 35W high efficient LED streetlight, aluminium pressure die cast housing parts for long life, pure polyester powder coated dark gray housing, high purity, PMMA lenses for superior performance, toughened glass with silicon gaskets for IP 65 protection, driver cover designed to suit top maintenance, suitable for external pole dia upto 50mm, temperature range - 0 to 50 degree centigrade, CRI>70, driver efficiency >85%, power factor >0.95, THD<10%, colour temperature - 5700K, surge protection - 4KV in CM, 50000 burning hours, lumianire efficacy>92lm/W, with and including provision of GI pipe bracket 1.20metre long bent to shape required using 25mm bore dia GI pipe light grade with and including provision of clamps etc., complete all as specified and directed. MAKE:- Cat No. ENDURACITY LITE PLATPLUSSL35WLED757 SASY BOPC of Havells or techno-commercially equivlent model in Philips / Bajaj / Wipro / CG / Jaquar
MCB DB, SPN, double door, epoxy powder coated, factory made 4-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCB DB, SPN, double door, epoxy powder coated, factory made 8-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, fixed in repairs, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) If earth resistance is not found satisfactory, till satisfactory test result comes, the same shall be redone by the contractor without any extra cost to department.
MCB TPN 63 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, complete all as specified and directed.
MCB DB, TPN, double door, epoxy powder coated, factory made 4-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, fixed in repairs, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
LED decorative wall light fitting nade up of polycarbonate suitable for 15W TU retrofit CFL (B-22 base), polycarbonate body weather proof, LED light fitting envitronmental friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. CITY 4, LHFODDFE1TC1W015 of Havells or techno-commercially equivalent model in Philips / CG
Fan hook, fixed in repairs, made out of MS FI 40mm x 6mm suitable for hanging of ceiling fan, with and including provision of suitable size of nuts, bolts, washers to be fixed in pipe of 40mm bore dia of GI pipe, complete all as specified and directed.
Supply, installation, testing and commissioning of water cooler, electric driven (single phase) having approximate capacity of 80 litre and normal cooling capacity of 40 litre per hour, alongwith provision of suitable accessories as required for sucessful working of cooler, complete all as specified and directed. MAKE:- Voltas / Bluestar
Voltage stabilizer, wall mounted, naturally cooled, indoor type, Automatic Boost / Buck for low and high voltage correction equipped with electronic circuit, relays of single phase 50Hz AC supply, complete designed for input voltage of 170 to 250 Volts and output voltage stabilized at 230Volts with an accuracy of ± 2.5%, TDR to 3min ± 20% seconds, of 2KVA capacity, complete all as specified and directed. MAKE:- V-guard / Keeline
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, 15mm bore, complete all as specified and directed.
Sub main wiring complete with 2 runs of 2.5 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of rigid PVC conduit 20mm dia including conduit accessories and connecting terminal ends to DB's including providing 1 run of 2.5 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Two runs of2.54 sq.mm copper conductor, one run of 2.5 sq.mm copper earth continuity conductor and one run of PVC casing / caping shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
MCB DB, SPN, double door, epoxy powder coated, factory made 4-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, fixed in repairs, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
Provision of platform for water cooler using PCC 1:3:6 type C1 (20mm graded stone aggregate), 1150mm below and 150mm above existing finished floor / existing ground level as directed, platform of size 1000mm x 1000mm x 150mm duly grouting the legs of cooler as required, complete all as specified and directed.
Supply, installation, testing and commissioning of desert cooler, electric driven (single phase) with kit fan motor 450mm sweep, made out of PGI sheet 1mm thick of size not less than 0.5 width and 0.7m height and storage tank of PGI sheet 1mm thick of size not less than 0.7m x 0.7m and height 0.2m, having approximate normal air flow of 5000 cu.m per hour, alongwith provision of suitable accessories as required for sucessful working of cooler, complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks or supporting stand for desert coolers etc., and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
Ball valve high pressure PTMT with epoxy coated aluminium rod and high density plastic ball secured for iron pipe of dia 15mm (minimum weight 142 gram), fixed in repairs, complete all as specified and directed.
LED streetlight, 90W, made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete including LED lamps and all accessories with and including provision of GI bracket made out of 40mm bore light grade GI tubing of 1.50metre length bent to shape required and fixed to existing pole or building by means of two Nos MS FI 40mmx6mm clamps with suitable size bolt, nuts and washers and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from fittinge to existing junction box of required length, complete all as specified and directed. MAKE:- Cat No. LHETBXU7PA6J090 of Havells or techno-commercially equivalent model in Philips / Bajaj / CG
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 10 sq.mm 2 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of rigid PVC conduit 25mm dia including conduit accessories and connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC conduit and conduit accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amp, complete all as specified and directed.
Area lighting luminaire 150W, epoxy powder coated die-cast aluminium housing (ADC12) in grey finish with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. M16 gland shall be used for cable entry and provision for loopin-loopout, high efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >140 lm/W and viewing angle of 120° to ensure better uniformity, PC Lens with symmetric light distribution and Toughened glass fixed to housing with 06 Nos screws (for detailed photometric data, LM 79 certified, independent Potted IP67 electronic LED driver with APFC, lower THD, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10 kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1, wall or surface mounting using adjustable MS cradle of thickness 4 mm with SS angular dial provided with the fixture for precise angular mounting of luminaire, with and including provision of all accessories including GI bracket made out of 25mm bore light grade GI tubing of 1.20metre length bent to shape required and fixed to existing pole or building by means of two Nos MS FI 40mmx6mm clamps with suitable size bolt, nuts and washers and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from fittinge to existing junction boxr of required length, fixed in repairs, complete all as specified and directed. MAKE:- Cat No. JETAIRISFLS150WLED757PSYMLTG of Havells or Cat No. LFLN-150-CDL/60 of Crompton or Cat No. BJFL150WLED of Bajaj.
Post-top lantern (landscape lighting), LED 35W, energy saving, 5700K, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, fixed in repairs, complete all as specified and directed. MAKE:- Cat No. RUBYPT35WLED757PSYMTOPC of Havells or techno-commercially equivalent model in Bajaj / CG / Philips
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 16 sq.mm 2 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
Preparation of old plastered surfaces of walls of any description over 10cm width or girth not otherwise described and applying one coat of cement base paint, complete all as specified and directed.
M/S A P CONSTRUCTION
sethi tradres
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .