| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹39.8 L+₹7.9 L (24.6%)Rejected-Finance SUN STAR CO OP HSG SOCIETY LTD PLOT NO 309 SHOP NO 5 SECTOR 21 NERUL NAVI MUMBAI 400706 | NAVI MUMBAI | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹49.0 L+₹17.0 L (53.3%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
5 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) KUNJALI
Dr Homibhabha Road, Colaba, Mumbai - 400005
8317 REPAIR MAINT TO ELECTRIC SUPPLY NETWORK COMPONENTS INCLUDING CABLE DUCT AND CABLE TRAYS AT VARIOUS JETTY AT NAVAL DOCKYARD MUMBAI
2020_MES_397786_2
8317/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹94,000
Yes
12 Feb 2021
21 Dec 2020
7 Jan 2021
22 Dec 2020
5 Jan 2021
22 Dec 2020
21 Dec 2020 - 22 Dec 2020
60 days
Amount
Supply and fixing in repair Framed work such as grills,gratings, etc.. with ends of bar shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walkways; railings; framework of water tanks, cable trays and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed .
S & F in repair, Mild steel, plain, blacksheet in wall cladding,steel gates and similar work, cut to size, holes punched; including ground headed screws,clout nails or rivetsand fixed to wood orsteel framing withplain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required but of thickness not less than 1.00mm complete all as specified and directed .
S&F in repair of MS/ GI hot dip/ powder coated perforated GI cable tray sheet thickness not less than 1.6mm , 50 mm height of tray and width not less than 450mm to be fixed on any wall (brick/stone) vertically/horizontally ,including tray cover of thickness not less than 2.00mm,including all accessories complete bending, shaping, drilling, welding, cutting and including all fixing arrangement such as suitable size of nuts, bolts, coupler plates etc complete all as specified and directed .
S&F in repair of GI hot dip/ powder coated GI cable ladder sheet thickness not less than 1.6mm , 75 mm height of tray and width not less than 500mm to be fixed on any wall (brick/stone) vertically/horizontally ,including tray cover of thickness not less than 2.00mm,including all accessories complete bending, shaping, drilling, welding, cutting and including all fixing arrangement such as suitable size of nuts, bolts, coupler plates etc complete all as specified and directed.
S&F in repair of GI hot dip/ powder coated GI cable ladder sheet thickness not less than 2.0 mm ,75 mm height of tray and width not less than 1000mm to be fixed on any wall (brick/stone) vertically/horizontally ,including tray cover of thickness not less than 2.00mm,including all accessories complete bending, shaping, drilling, welding, cutting and including all fixing arrangement such as suitable size of nuts, bolts, coupler plates etc complete all as specified and directed .
S & F in repair MS plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk) forming holes, without any attachment and similar work conforming to Fe 410-W(Gde-E- 250) quality A complete all as specified and directed .
Taking down and refixing exisitng LT Cable aluminium/copper any size laid on wall/floor , including all accessories all as directed and specified
Supply and fixing in replacement of galvanised pipe light grade 100 mm dia for passing of cables under the road cutting complete all as specified and directed .
Supply and fixing in replacement of galvanised pipe light grade 80 mm dia for passing of cables under the road cutting complete all as specified and directed .
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185sq mm 3.5 core. Laid in duct / along pole/wall tc including making connection complete all as specified and directed . Note : 1. The cost of AI thimbles/lugs and calbe gland etc is deemed to be incl in quoted rates.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300sq mm 3.5 core. Laid in duct / along pole/wall tc including making connection complete all as specified and directed . Note : 1. The cost of AI thimbles/lugs and calbe gland etc is deemed to be incl in quoted rates.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400sq mm 3.5 core. Laid in duct / along pole/wall tc including making connection complete all as specified and directed . Note : 1. The cost of AI thimbles/lugs and calbe gland etc is deemed to be incl in quoted rates.
Excavation in tenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in hard/dense soil for laying of under ground cable complete all as specified and directed .
Returning filling in including spreading, leveling watering and well ramming in layer not exceeding 25Cms complete all as specified and directed .
Removal of excavated surplus soil not exceeding 50m and depositing where directed at al level not exceeding 1.5m above the starting point complete all as specified and directed .
Supply and spreading sand in trenches as cushioning to under ground cable on top and bottom of cable complete all as specified and directed .
Supply and laying un-reinforced pre cast concrete cable cover class LV type II flat of size 300 x 180mm 40mm complete all as specified and directed .
Nexus Infratech
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .