Loading…
Loading…
Tender Value
₹11.5 Cr
EMD Value
₹23.0 L
Closing Date
25 Aug 2026, 12:00 pm
VIJAY KUMAR BHAGOTIA
W.S. Divn. No. II Rewari
Construction of a pump house facility, including associated structures such as an inlet water tank, sump, panel room, steel walkway, and EOT crane system. The primary objective of the facility is to enable efficient lifting and handling of water accu
2026_HRY_538877_1
2026F1A1A20B 3808 477D A1EE 095C94554673137IRR
Open Tender
Civil Works
Works
210 days
KHALIAWAS
3 documents required · 3 mandatory
₹20,000
₹23.0 L
Yes
office of Executive Engineer, W/S Division No. 2
5 Aug 2026
5 Aug 2026
25 Aug 2026
5 Aug 2026
25 Aug 2026
5 Aug 2026
5 Aug 2026 - 7 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply, installing, testing and commissioning of 400 mm i/d DI DF Metal Seated Non Rising Spindle Sluice Valve of pressure grade PN1.6 as per IS: 14846: Body Dome: DI IS 1865 Gr 400/15: Wedge:DI IS 1865 Gr 400/15: Body and Wedge Rings: Bronze IS: 318 Gr LTB2 Spindle: SS AISI 410, Fasteners: CS. Flange Drilling: IS 1538 Table 486, Operation - Manual and Electric Actuator(AUMA, Rotorek, Pneutork, Marsh Pneumatic, Elomatic make with inetegral starter), complete in all respect as per site requirement and to the satisfaction of Engineer-in-charge, of make IVC Nasik, VAG, Talis, Kirloskar. (NS Item) | - | Each | 4,92,712 | - |
| 1.02 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Made of G.I. wire of dia 4 mm | - | Sqm | 1,017.8 | - |
| 1.03 | `Planning, Designing, Supply, Installation, Testing and Commissioning of LV PMCC Panel (Complete with Incomer for 1 Nos. Transformers and 2 Nos. DG sets of required capacity, Bus coupler, Motor Starters like DOL/Star Delta/Soft Starter/ VFD, PLC (for auto load management, load sharing, AMF and synchronisation) etc. as Per approved Drawing and Specification) shall be Metal enclosed (3 mm thick CRCA sheet for load bearing member and 2 mm thick for non-load bearing member, Double Front, Compartmentalized type provided . PMCC’s shall be metal clad floor mounted, with cable entry from Top/Bottom of the panel and environmentally protected to IP-52 (Indoor) Location. PMCC shall have fault rating 50 KA for 1sec. IN PMCC Panel Bus bar shall be AL conductor : Panel Switchgear Make Shall be As Schneider / Siemens/ /ABB/GE and Panel shall be assembled by reputed Panel Vendor/channel Partner. Panel construction shall be As per IEC 60668 and Wiring Shall be As per IEC 60364. All the Selected switchgear for motor feeder shall confirming the Type 2 co-ordination. PMCC panel shall have SCADA compatibility for operation, monitoring and control as per the system requirement. Panels shall consist the following
1. 4000 Amp., 415 Volt 50 Hz, EDO ACB for Transformer supply -412 Nos.
2. 1600 Amp., 415 Volt 50 Hz, EDO ACB for DG supply -2 Nos.
3. 4000 Amp., 415 Volt 50 Hz, EDO ACB for Bus Coupler supply -2 Nos. all ACB shall have phase indication, on, off, trip indication, spring charge and control supply healthy indication, Digital Volt Meter and Ammeter with seclector switch, Protection Relays and annunciator, local remote selector switch etc. complete in all respects.
4. DOL Starter feeder for motor operated equipment like motorized valve, gate etc. as required with local/ remote selector switch, open-close push button, open close indication, interlock facilities with field equipment.
5. DOL/Star delta starter feeder for pumping machinery with local remote selector switch, start-stop push button and indication with ditigal type ammeter with selector switch.
6. Out-going MCCB feeder of suitable rating for EOT crane, internal-external lighting and auxiliary supply of equipment as required. | - | Nos. | 32,68,306 | - |
| 1.04 | `Supply, installation, testing and commissioining of level indicator with transmitter (ultrasonic type) with 4 - 20 mA analoge output suitable for at HART communication including all other required accessories as required for measurement complete in all respect with SCADA compatibiltiy.Make Endress plus Hauser,Honeywell,Hycontrols,UK,ABB | - | NO. | 21,200 | - |
| 1.05 | `Supply,Installtion/Erection,testing and commissioning of Pressure Transmitter Bourdon Pressure Gauge with their accessories at site, confirming to the tender/system requirement and technical specification complete in all respects up to the entire satisfaction of Engineer-In charge of the works.
Make:ABB,Warne,Endress plus Hauser,Hach. | - | NO. | 18,000 | - |
| 1.06 | Providing and fixing Stainless Steel Wall mounted Bracket
Supports to support Verticle Pipe Scheme for Pump Chamber
for diameter of pipe -250 mm Ø for Pumping Scheme. | - | Each | 12,874 | - |
| 1.07 | `Supply and fixing polycarbonate junction box having degree of protection IP66 complete in all respect including required i/O terminal , required no. of glands for signal cable upto 12 pair 1.5 sqmm, instrumentation cable make -Hensal, schneider or any approved make.
(NSR)` | - | Each | 2,060 | - |
| 1.08 | Supply and laying of Premier Insulating Mat `B` calss as per IS-15652:2006 (NSR)` | - | Sqm | 1,028 | - |
| 1.09 | `Wall Mounted S.S. Support Brackets for Vertical Portions of Pipe
(NSR)`
For 400 mm Ø- Pipe | - | Metre | 20,598 | - |
| 1.1 | `Supply, inspection testing commissioning and laying of steel strip armoured XLPE insulated cable laid in ground cable, loose in existing pipe, trenches and Cable Tray etc. as required complete with necessary connections.
(NSR)`
4 C x 4 sqmm CU XLPE Insulated power cable for actuator power supply
Make: Finolex / Fort Closter / KEI/ L andT or approved make | - | Metre | 391 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.58 MB
BOQ_618104.xls
BOQ • 0.54 MB
AD0173010.pdf
Additional Documents • 1.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].