Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC Awarded as first lowest bidder (L1) | |
| 2 | L2₹36.1 L+₹6.0 L (19.8%)Rejected-AOC | L2 | Rejected-AOC Awarded as second lowest bidder (L2) | |
| 3 | L3₹39.0 L+₹8.9 L (29.5%)Rejected-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L3 | Rejected-AOC Awarded as third lowest bidder (L3) | |
| 4 | L4₹39.7 L+₹9.6 L (31.8%)Rejected-AOC | L4 | Rejected-AOC Awarded as forth lowest bidder (L4) | |
| 5 | L5₹41.0 L+₹10.8 L (35.9%)Rejected-AOC | L5 | Rejected-AOC Awarded as fifth lowest bidder (L5) |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
9 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIR AND MAINT OF CHILLED CENTRAL PACKAGE SPLIT WINDOW TYPE AC AT ARDE UNDER GERD PASHAN
2020_MES_408483_1
GERD/PSN/TOKEN/29 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GERD PASHAN PUNE
₹70,000
Yes
19 Mar 2021
31 Dec 2020
11 Feb 2021
1 Jan 2021
9 Feb 2021
16 Jan 2021
1 Jan 2021 - 13 Jan 2021
60 days
Amount
Material and labour for disconnecting and dismantling of compressor from Central Air Conditioning plant by putting plates to the suction and discharge valve including taking down the crank shaft, cleaning, overhauling of Compressor including replacement of worn out parts such as suction reeds, discharge reeds, cylinder liners, springs, washers, nuts, bolts, gaskets, shaft seals, flanges, sockets, "O" rings including necessary cuttings, metalising, grinding, balancing the crank shaft if required, changing the compressor oil, leakage testing with Nitrogen, repairing leakages if any, charging F-22 gas & refrigerant including replacement of unserviceable of spare parts as required at site and minor repairs required for smooth working of compressor completely including transportation to work shop and back and reassembling the compressor, reinstalled in the position with correct alignment, testing, commisioning, performance testing for 08 hours to achieve desired performance, parameter complete of any Make as specified and directed. Notes :- (i) The cost of additional minor spares, accessories, fasteners if any required to make the machine fully serviceable, cost of labour charges for replacement of unserviceable spare parts in compressor, charging of oil and gas is deemed to be included in the quoted rate. (ii) Refrigerant Gas (R-22) and compressor oil required for charging and spares required to be replaced for overhauling of compressor shall be measured and paid for separately as 'supply only' under respective item of BOQ.
Supply only following spare part of compressor of Make : Kirloskar model FK 4 (6.5/12.5/15 TR), Model AC 470 35 TR complete all as specified and directed :- (a) Piston assembly aluminium alloy complete.
(b) Piston pin & piston ring.
(c) Suction and discharge valve with valve retaining plates and ring plates, spring guides, valve bolts and Nuts complete.
(d) Main bush bearing with bushing collar for crank shaft as per existing.
(e) Gasket Set (Packing kit) for compressor including top cover, side cover, end cover and bearing cover complete.
(f) Connecting rod alumunium alloy with small end and big end bearings complete.
(g) Rocker including cylinder, springs, spring holder, retainers, spring guide complete.
(h) Suction strainer as per existing specifications.
(j) Neoprene 'O' ring set for compression with aluminium washer complete kit.
(k) Oil strainer and oil filter complete
(l) Guide for Discharge valve.
(m) Oil pump assembly complete as per existing specifications.
(n) Suction and discharge reed with 'O' ring complete.
(o) Cylinder liner cast steel as per existing specifications.
(p) Safety valve assembly complete.
Supply and fixing in repairs wornout crankcase heater for compressor of Make : Kirloskar model FK 4 ( 6.5/12.5/15 TR), model AC 470 35 TR as per existing specifications complete all as specified and directed.
Supply and fixing in repairs shaft seal assembly for vaious models of compressors of Make : Accel / Kirloskar complete all as specified and directed.
Material and labour for descaling of shell and tube type water cooled condenser of capacity 5 to 7.5 TR including descaling of MS shell , intergral copper tubes and safety valve with cleaning agent like nitrogen flushing / descaling compound and through cleaning with descaling nylon brush and circulating by descaling pump including repalcement of gasket sets, nuts and bolts and leak testing after descaling / cleaning of condenser unit complete all as specified and directed.
Material and labour for descaling of shell and tube type water cooled condenser of capacity 8 to 15 TR including descaling of MS shell , intergral copper tubes and safety valve with cleaning agent like nitrogen flushing / descaling compound and through cleaning with descaling nylon brush and circulating by descaling pump including repalcement of gasket sets, nuts and bolts and leak testing after descaling / cleaning of condenser unit complete all as specified and directed.
Material and labour for descaling of shell and tube type water cooled condenser of capacity 16 to 20 TR including descaling of MS shell , intergral copper tubes and safety valve with cleaning agent like nitrogen flushing / descaling compound and through cleaning with descaling nylon brush and circulating by descaling pump including repalcement of gasket sets, nuts and bolts and leak testing after descaling / cleaning of condenser unit complete all as specified and directed.
Material and labour for descaling of shell and tube type water cooled condenser of capacity 21 to 35 TR including descaling of MS shell , intergral copper tubes and safety valve with cleaning agent like nitrogen flushing / descaling compound and through cleaning with descaling nylon brush and circulating by descaling pump including repalcement of gasket sets, nuts and bolts and leak testing after descaling / cleaning of condenser unit complete all as specified and directed.
Material and labour for disconnecting electrical connections of motor located at top of cooling tower, keep cables at safe custody for reconnection and dismantling and taking out fan blade assembly along with motor mounted on base frame at the top of cooling tower after cutting/dismentaling all nuts, bolts and fixtures from the mounting frame and removing whole assembly including motor and base frame from the top of cooling tower with the help of T&P for servicing of cooling tower suitable for 5-30 TR capacity including comprising following complete all as specified and directed :- (i) Cleaning /scrapping of inner & outer surface of FRP basin, repair of damaged portion if any incuding FRP lining of all surfaces joints to avoid leakage including replacement of all nuts and bolts joining all parts of basin complete, (ii) servicing cooling tower plant through cleaning re-agent complete pipe line, including servicing of cooling tower motor and fan and make the necessary alignment with motor, (iii) replacement of bearing of suitable cap if any during servicing including gressing and replacement of nuts, bolts and preventing leakage if any by means of suitable adetives, (iv) taking out PVC fills, blocks, cleaning and refixing as per existing location and channel direction, (v) servicing of spray header and sprinkler assy complete, (vi) repair of water strainer complete. Notes :- (i) The cost of additional minor spares, accessories, fasteners if any required to make the cooling tower fully serviceable, cost of labour charges for replacement of unserviceable spare parts in cooling tower is deemed to be included in the quoted rate. (ii) Spares required to be replaced for serving of cooling tower shall be measured and paid for separately as 'supply only' under respective item of BOQ.
Supply only following spare part of cooling tower of capacity 5 TR to 60 TR of Make : Kool Drop / MIHIR / ADVANCE / HIMGIRI complete all as specified and directed :- (a) PVC fill in columns of size 60 x 30 x 15 cm or next higher size as per existing specification and requirement complete.
(b) PVC fill in columns of size 60 x 15 x 15 cm or next higher size as per existing specification and requirement complete.
(c) Roller bearing / Pedestal bearing for fan motor as per sample of make SKF.
(d) Ball / Roller bearing for Sprinlkler top and Bottom Hub for 5 TR to 15 TR capacity
(e) Ball / Roller bearing for Sprinlkler top and Bottom Hub for 16 TR to 30 TR capacity.
(f) Sprinkler Hub top and bottom portion with PVC pipe and cap complete set for capacity 15 to 30TR.
(g) PVC nozzle.
Supply and fixing in repairs toggle switch one way 5 Amps including control wiring and lugs if any complete all as specified and directed.
Material and labour for servicing and cleaning of cooling coil 4-6 rows deep of capacity 5 TR to 60 TR AHU with cleaning agent and remove the oil and dust from fins and cooper tubes / pipes complete including checking of copper tubing for leakage, maching/ repairing /brazing of leakaged tubes complete including sealing of joints complete all as specified and directed. NOTE :- Spares required to be replaced for serving of AHU shall be measured and paid for separately as 'supply only' under respective item of BOQ.
Supply only following spare parts for AHU of capacity 5 TR to 60TR of Make : Kool Drop / AIRCON / ZECO as per sample of existing make availale at site :- (a) Roller bearing / ball / taper bearing for blower motor as per sample of make SKF.
(b) Ball / Roller bearing/Pedestal for Blower shaft as per existing specifications.
Material and labour for repair of spray water type dehudification system of Air Handling Units complete by pressurized cleaning of spray water header with nozzle complete including replacement of following unservicible spare parts complete all as specified and directed :- (a) Spray water nozzle, (b) Flexible PVC pipe Heavy duty of 20 mm dia complete from water tank to dehumidifier pump, (c) GI pipe medium grade of 20mm dia with fittings and (d) Rewinding & repairing dehumidifier pump 1 Phase, 240V 0.5 HP to 1 HP capacity - 01 No.
Supply and fixing in repairs following spare part of hot water generator of capacity 10KW TR to 50KW of Make as per sample / existing make availale at site complete all as specified and directed :-. (a) Heater Rod 3KW, suitable 3 PH, 415V AC supply as per sample.
(b) Heater Rod 9KW, suitable 3 PH, 415V AC supply as per sample.
(c) Duct / strip Hitter 2 Kw Suitable 1 PH, 230V ac Supply as per sample.
(d) Duct/ Strip Hitter 3/4 Kw sutibale 1 PH, 230v AC supply as Per sample.
(e) Terminal heater plate suitalble for heater rod 3 KW/9KW including control circuit.
(f) Thermostate and control switch ON/OFF assy control auto and manual paramerter.
Material and labour for repairs to condenser / chiller pump including dismantling of Pump and segregating its parts for repairs and maintenance, replacement of spare parts requiredto be replaced including grinding, polishing, bend removing etc including spray painting with two coats of synthetic enamel paint and reassembling of pump after repair work & testing complete complete all as specified and directed for the following capacity pump:- Notes : (i) The cost of minor spares, accessories, fasteners if any required to make the pump fully serviceable, cost of labour charges for replacement of unserviceable spare parts is deemed to be included in the quoted rate. (ii) Spare parts required to be replaced will be measured and paid separately as 'supply only' under relevent item of BOQ. (a) Pump 3 HP Upto 7.5 HP.
(b) Pump 7.5 HP to 15 HP.
Supply only following srare parts of pump set complete all as specified and directed :- (a) Shaft bearing up to 3 HP pumpset as per existing specifications.
(b) Shaft sleeve up to 3 HP pumpset.
(c) Impeller up to 3 HP pumpset.
(d) Impeller Key of 3 HP pumpset.
(e) Shaft bearing 5 to 7.5 HP pumpset
(f) Shaft sleeve of 7.5 HP pumpset
(g) Impeller of 5 to 7.5 HP pumpset
(h) Impeller Key of 7.5 HP pumpset .
(j) Shaft bearing of pumpset above 7.5 HP up to 10 HP.
(k) Shaft bearing for 10 HP up to 15 HP pumpset .
(l) Shaft sleeve of pumpset above 7.5 HP up to 10 HP.
(m) Shaft sleeve for 10 HP up to 15 HP pumpset.
(n) Mechanical Couplings for Pumpset 3 HP up to 5 HP pumpset
(o) Mechanical Coupling for Pumpset 7.5 HP up to 15 HP pumpset .
Material and labour for disconnecting from main supply carefully squirrel cage induction motor 3 Phase, 415V AC from existing foundation and taking to workshop for servicing and necessary repair including replacement of unserviceable parts as ordered including supply and fixing minor required items like nuts, Bolts , washers, carry out Misc repairs and reassembling, testing and commisssioning the motor after repair including transportation from site to workshop and back all as specified and directed for the following capacity motor :- NOTE : (i) Cost of labour for replacement of bearigs shall be deemed to be included in qouted rate. Bearings shall be measured and paid for separately as 'suply only' in respective item of BOQ. (a) Motor 1 to 2 HP.
(b) Motor 3 to 5 HP.
(c) Motor 7.5 to 15 HP.
(d ) Motor 16 to 40HP.
Supply only Ball bearing for squirral cage induction motor of capacity 1 HP to 20 HP
Supply only Ball bearing for squirral cage induction motor of capacity 25 HP to 75 HP
Material and labour for disconnecting the electrical and mechanical connection of burnt electrical motor from the site / location, transporting to and from to work shop, rewinding of electrical motor/ pump motor winding polyster based super enamelled copper wire of same gauge of original one with proper class of insulation including varnishing by dismantling and removing the burnt cut copper winding wire, cleaning the slots of startor with petrol and brushes and heating the coil and remove air bubbles complete stator / roter after rewinding and reassembling all parts including reinstalling connection to original position and testing on full load complete all as specified and directed for different capacity of motor as per following :- (a) Motor 1 to 2 HP.
(b) Motor 3 to 5 HP.
(c) Motor 7.5 to 15 HP.
(d ) Motor 16 to 40 HP.
Supply and fixing in repairs 50 mm bore C-1 butterfly valve with maching double flanges , gaskets, necessary hardware complete all as specified and directed.
Supply and fixing in repairs 80 mm bore C-1 butterfly valve with maching double flanges , gaskets, necessary hardware complete all as specified and directed.
Supply and fixing in repairs thermal expansion valve suitable for 5 to 15TR chilled water central type AC plant system all as per sample, including brazing at both ends complete all as specified and directed.
Supply and fixing in repairs thermal expansion valve suitable for 16 to 35 TR chilled water central type AC plant system all as per sample, including brazing at both ends complete all as specified and directed.
Material and labour for locating and identifing gas and oil leakage and removing the leakage by repairing, brazing, flaring of tubings of central type AC Plant of capacity 5 TR to 10TR including leakage testing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results complete all as specified and directed. Note : Nitrogen gas and refrigerant will be measured and paid separately as 'supply only' under respective item of BOQ.
Material and labour for locating and identifing gas and oil leakage and removing the leakage by repairing, brazing, flaring of tubings of central type AC Plant of capacity 11 TR to 25 TR including leakage testing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results complete all as specified and directed. Note : Nitrogen gas and refrigerant will be measured and paid separately as 'supply only' under respective item of BOQ.
Material and labour for locating and identifing gas and oil leakage and removing the leakage by repairing, brazing, flaring of tubings of central type AC Plant of capacity 26 TR to 35 TR including leakage testing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results complete all as specified and directed. Note : Nitrogen gas and refrigerant will be measured and paid separately as 'supply only' under respective item of BOQ.
Material and labour for checking and testing of electrical control panel of AC Plant for interlock panel wiring, detecting the fault / defects including replacement of minor burnt wires, lugs, terminals and making panel in workable condition including testing complete all as specified and directed.
Material and labour for taking down of old broken GI ducting and providing GI sheet 22 guage with TDF flanged rectangular/square duct made of "L" shaped hollow profile including all accessories such as corners, cleats, carriage bolts, gaskets and appropriate sealent on longitudinal joints complete including GI sheet cover 28 guage all as directed and connecting / matching to the existing ducting system, including necessary brackets / supports of suitable size MS angle and applying painting to supports with two coats of synthetic enameled paint over a coat of primer including preparation os steel surfaces complete all as specified and directed. Note : Insulation will be measured and paid for separaterly.
Supply and fixing in repairs 9 mm thick Nitrile Rubber insulation of density 40-50 kg/m3 using CPRX solution as adhesive complete all as specified and directed.
Material and labour in repairs for ducting insulation made of fiber glass wool roll of density 24 kg/cum of thickness of insulation 50 mm including jointing with propper sealing against any leakges and applying rubber based adhesive CPRX compound, sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide to make the insulation leak proof, securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 50 mm at maximum intervals of 1.2 metre complete all as specified and directed.
Material and labour for spray painting to air conditioning plant equipments refrigerant / water suction / discharge / liquid piping of any specification with synthetic enameled paint of best quality including prepration of steel surface including concealed fitments e.g., condenser , chillar, valves etc as per IS colour Code of Cental Air Cinditioning plants including writing MES / SM No complete all as specified and directed.
Material and labour for replacement of existing thermocoal / PUF insulation and providing Material and labour for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and outer cladding with 28 gauge Aluminium sheet complete of 50 mm dia sizes complete all as specified and directed. Note : The U/S thermocoal insulation shall be buried in ground after replacement where directed. Cost of earth work including excavation, removal and returning filling required and removing surplus soil/ material is deemed to be included in the qouted rate.
Material and labour for replacement of existing thermocoal / PUF insulation and providing Material and labour for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and outer cladding with 28 gauge Aluminium sheet complete of 65 mm dia sizes complete all as specified and directed. Note : The U/S thermocoal insulation shall be buried in ground after replacement where directed. Cost of earth work including excavation, removal and returning filling required and removing surplus soil/ material is deemed to be included in the qouted rate.
Material and labour for replacement of existing thermocoal / PUF insulation and providing Material and labour for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and outer cladding with 28 gauge Aluminium sheet complete of 80mm dia sizes complete all as specified and directed. Note : The U/S thermocoal insulation shall be buried in ground after replacement where directed. Cost of earth work including excavation, removal and returning filling required and removing surplus soil/ material is deemed to be included in the qouted rate.
Material and labour for replacement of existing thermocoal / PUF insulation and providing Material and labour for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and outer cladding with 28 gauge Aluminium sheet complete of 100 mm dia sizes complete all as specified and directed. Note : The U/S thermocoal insulation shall be buried in ground after replacement where directed. Cost of earth work including excavation, removal and returning filling required and removing surplus soil/ material is deemed to be included in the qouted rate.
Supply only R-407C Refrigerant gas in returnable company sealed cylinder of 61kg each with manufacturer's test certificate complete all as specified and directed. Make : Mafron/Feron or equivalant as approved by GE. Note : (i) Hire charges of cylinder shall be deemed to be included in qouted rate. (ii) Charging of refrigerant Gas shall be measured and paid under respective item of BOQ or whereever required.
Supply only R-22 Refrigerant gas in returnable company sealed cylinder of 61kg each with manufacturer's test certificate complete all as specified and directed. Make : Mafron/Feron or equivalant as approved by GE. Note : (i) Here charges of cylinder shall be deemed to be included in quoated rates. (ii) Charging of refrigerant Gas shall be measured and paid under respective item of BOQ or whereever required.
Supply only Nitrogen Gas at required pressure for leak testing of central AC plant filled in standard size cylinder at required pressure complete all as specified and directed.
Supply and charging of compressor oil N-68 after flushing out old oil of compressor and testing & commissioning complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-26 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-28 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-32 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-50 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-132 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-62 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-82 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-90 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs pressure diffrential control cutout for central type A/C plant and testing complete all as specified and directed of following size :-Engineer-in-Charge. (a) Oil pressure cutout MP-55
(b) Low pressure cutout MP-5
(c) High pressure cutout MP-1
Supply, installation, testing & commissioning in repairs water cooled scroll type compressor 5 TR to 7.5 TR of semihermatically sealed scroll motor with internal overload protector, compressor mounted on existing base including connecting with existing refrigerant pipe line , integral refrirant piping and wiring accessories as required complete all as specified and directed including comprising of following :- Auto /Manual single phasing protection, Compressor restart protection, 10 sec - time delay between system, Short circuit protection, 5 degree C anti freeze protection, Display on micro control indicating compressor on crank case heater on / off, Entering/ leving water temperature' Scroll chiller unit shall be suitable for 415 + 15% 50 C/S 3 phase AC supply, and Refrigerant used shall be R-22 or suitable for existing system as mentioned in specifications of manufacturer.
Supply, installation, testing & commissioning in repairs water cooled scroll type compressor 10 TR to 20 TR of semihermatically sealed scroll motor with internal overload protector, compressor mounted on existing base including connecting with existing refrigerant pipe line , integral refrirant piping and wiring accessories as required complete all as specified and directed including comprising of following :- Auto /Manual single phasing protection, Compressor restart protection, 10 sec - time delay between system, Short circuit protection, 5 degree C anti freeze protection, Display on micro control indicating compressor on crank case heater on / off, Entering/ leving water temperature' Scroll chiller unit shall be suitable for 415 + 15% 50 C/S 3 phase AC supply, and Refrigerant used shall be R-22 or suitable for existing system as mentioned in specifications of manufacturer.
Supply and fixing in repairs pilot solenoid valve assembly for central type AC plant as per sample complete all as specified and directed.
Supply and fixing in repairs pressure gauge freon R22/ R407C 4" dia with tube to match & stop cock of required size for range 0 to 150 PSI complete all as specified and directed.
Supply and fixing in repairs pressure gauge 4" dia suitable for refrigerent R-22 and compressor oil including 1/4" copper pipe end to U shape with flair nuts/adopter at both ends,range of gauge -30 to 300 PSI complete all as specified and directed.
Supply and fixing in repairs thermometer to condenser/chiller, inlet or outlet water pipes including addition alteration to pipe line for fixing thermometer Range 0-100 degree F / degree centigrade complete all as specified and directed.
Supply and fixing in repairs water presuure gauge 0-7 kg / cm2 any type of Make Febig or equivalant as approved by GE complete all as specified and directed.
Supply and fixing in repairs pressure relief valve of condenser 3/8" / 1/2" BSP threaded suitable for 300 PSI complete all as specified and directed.
Supply and fixing in repairs HRC fuse (Cylindrical / DIN type / Bolted) 10 Amps to 60 Amps conforming IS 13703 Part - II with high breaking capacity suitable for existing holders complete all as specified and directed.
Supply and fixing in repairs single phase preventer in electric panel board at central type AC plants complete all as specified and directed.
Supply and fixing in repairs 3 pole power contactor , coil voltage 230/415 Volts complete all as specified and directed for following capacity motor:- (a) Motor 12 Amps to 18 Amps.
(b) Motor 25 Amps to 32 Amps.
(c) Motor 40 Amps to 50 Amps.
(c) Motor 70 Amps to 90 Amps.
Material and labour in repair for Sub Zero for controlling & indicating humidity / temperature of central Plant along with humidity sensor length sa per existing at site complete all as specified and directed.
Supply & Fix in repairs Filter class G3 as per EN 779 for AHU complete all as specified and directed of following size:- a) 610mm x 610mm x 45mm.
b) 610mm x 305mm x 45mm.
c) 305mm x 305mm x 45mm.
(d) 400mm x 535mm x 20mm.
(e) 825mm x 515mm x 10mm.
(f) 600mm x 790mm x 10mm.
(g) 630mm x 830mm x 10mm.
(h) 410mm x 770mm x 10mm.
(j) 780mm x 830mm x 10mm.
(k) 7780mm x 830mm x10mm.
(l) 515mm x 815mm x 10mm.
(m) 785mm x 820mm x 10mm.
(n) 410mm x 530mm x 20mm.
(o) 560mm x 500mm x 50mm.
(p) 340mm x 600mm x 150mm.
(q) 600mm x 600mm x 150mm.
Supply & Fix in repairs Remote control of blue star Package Unit Model No. DPW 661S complete all as specified and directed.
Supply & Fix in repairs Power bord curcit (PCB) controller of blue star Package Unit of existing Model at site complete all as specified and directed.
Maintenance of Summer cooling appliances Material and labour for servicing o window type / Split type AC 1.5 TR / 2.0 /3.0 TR at site including cleaning evaporator, condensing coil by using carbon tetra chloride, combing the evaporator, condensor fins, greasing all the moveable parts of fan motor, testing the wiring of whole AC, checking all parts, cleaning the air filter and replacing the unserviceable spare parts, cleaning the tray and refixing the back AC in position by providing proper packing for better effects, testing and commissioning of AC including marking of SM / MES No. complete all as specified and directed.
Material and labour for disconnecting the water cooler of capacity 40 / 80 litre from electric & water connection at site and servicing the water cooler by cleaning condensor by using carbon tetra chloride combing the evaporator condensor fins, cleaning of water storage tank, greasing all the moveable parts of fan motor, testing the wiring & checking all parts and replacing the unserviceable spare parts including cleaning the tray and fixing back water cooler in position, testing and commissioning of water cooler marking of SM / MES No. complete all as specified and as directed.
Material and labour for disconnecting & taking out old unserviceable sealed unit compressor from water cooler of any make, model and capacity 40 / 80 litre and fixing new compressor and soldering to unit, testing of pressure including replacement of filter complete all as specified and directed.
Material and labour for labour for recharging of refrigrant gas R-134 and compressor oil for water cooler including flushing, pressure testing vaccumization the complete system and detection of leakage brazing etc; and testing system on full load capacity complete all as specified and as directed.
Material and labour in repairs for rewiring of condenser fan motor of water cooler 1 / 32 HP with supper enemalled copper wire of appropriate gauge of Make Devi Dyal or equivalant as approved by GE including insuation, refixing and testing at location complete all as specified and as directed.
Material and labour in repairs for relay with over load protection for water cooler any capacity complete all as specified and directed. Make : Sriram or as per existing as approved by GE.
Material and labour in repairs for thermostat for water cooler all as specified and directed. Make : ANNAPURNA or as per existing as approved by GE.
Material and labour in repairs for running capacitor 36 mfd, 230 volts complete all as specified and directed. Make : EPCOS or as per existing as approved by GE.
Material and labour in repairs for running capacitor 10 mfd, 230 volts complete all as specified and directed. Make : EPCOS or as per existing as approved by GE.
Material and labour in repairs for starting capacitor 80-100 mfd 230 volts complete all as specified and directed. Make : EPCOS or as per existing as approved by GE.
Material and labour in repairs for starting capacitor 40-60 mfd 230 volts complete all as specified and directed. Make : EPCOS or as per existing as approved by GE.
Material and labour in repairs for sealed unit compressor for refrigerator of capacity 165 to 310 litre and testing complete all as specified and directed. Make : As per existing or sample as approved by GE.
Material and labour for recharging gas R-134 and compressor oil for refrigerator of any type including flushing, pressure testing vaccumization the complete system and detection of leakage brazing etc, testing complete on full load capacity complete all as specified and directed.
Material and labour in repairs for relay starting cum over load protection for refrigerator any capacity complete all as specified and directed.
Material and labour in repairs for thermostat switch suitable for 165 / 286 / 310 litres refrigerator model S-1051 complete all as specified and directed.
Material and labour in repairs for sealed unit compressor from window type air conditioner capacity 1.5 Ton including pressure testing complete all as specified and directed.
Material and labour for charging refrigerant gas R-22 or suitable for system and compressor oil for window type AC 1.5 ton including flushing, pressure testing vaccumization the complete system and detection of leakage brazing etc; and testing complete system on full load capacity all as specified and as directed.
Material and labour in repairs for rewinding of condenser fan motor capacity 1/10 HP of window type AC with supper enameled copper wire of same gauge Make Devi Dyal or equivalant as approved by GE including refixing and testing of fan motor complete all as specified and directed.e
Supply and fixing in repairs sealed unit compressor from split Air conditioner of cap 1.5 TR / 2.0 TR including testing and taking out old unserviceable sealed unit compressor complete all as specified and directed.
Material and labour for rewinding of condenser fan motor of split type AC with supper enameled, copper wire of same gauge of Make Devi Dyal or equivalant as approved by GEincluding refixing and testing complete all as specified and directed by Engr-in Charge.
Material and labour for charging of refrigerant gas R-22 and compressor oil in split type AC 1.5 /2.0 TR capacity including vaccumising the complete system, detection of leakage, brazing etc, testing on full load all as specified and directed by Engineer-in-Charge.
Material and labour in repairs for PCB of 1.5 Ton / 2.0 Ton capacity window /split type AC with remote control kit ,connecting up and testing on load complete all as specified and directed.
Supply and fixing in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps from wall surface and fixing (AC Socket) for Window/Split AC all as directed and specified by Engr-in-Charge.
Supply and fixing in repairs 4 pole MCCB 200 Amps 415 V 25 KA with adjustable thermal and megnetic setting including spreaded links & extended rotary handle complete all as specified and directed.
Supply and fixing in repairs 4 pole MCCB 100 Amps 415 V 16 KA with adjustable thermal and fixed megnetic setting including spreaded links & extended rotary handle complete all as specified and directed.
Supply and fixing in repairs VAF meter for panel complete all as specified and directed.
Supply and fixing in repairs indication lamp red 230 V complete all as specified and directed.
Supply and fixing in repairs indication lamp yellow 230 V complete all as specified and directed.
Supply and fixing in repairs indication lamp blue 230 V complete all as specified and directed.
Supply and fixing in repairs indication lamp green 230 V complete all as specified and directed.
Supply and fixing in repairs indication lamp orange 230 V complete all as specified and directed.
Supply and fixing in repairs push button red with No/Nc element complete all as specified and directed.
Supply and fixing in repairs push button green with No/Nc element complete all as specified and directed.
Supply and fixing in repairs Add-on-block with 2 No & 2 Nc to match the contractor complete all as specified and directed.
Supply and fixing in repairs single phase preventer for panel complete all as specified and directed.
Supply and fixing in repairs overload relay 10-13 Amp complete all as specified and directed.
Supply and fixing in repairs overload relay 5-9 Amp complete all as specified and directed.
Supply and fixing in repairs overload relay 32 Amp complete all as specified and directed.
Supply and fixing in repairs overload relay 40 Amp complete all as specified and directed.
Supply and fixing in repairs control MCB SP 6 AMP 10 KA complete all as specified and directed.
Supply and fixing in repairs control MCB TP 20 AMP 10 KA complete all as specified and directed.
Supply and fixing in repairs control MCB TP 32 AMP 10 KA complete all as specified and directed.
Supply and fixing in repairs control MCB TPN 63 AMP 10 KA complete all as specified and directed.
Supply and fixing in repairs 3 way Auto/Manual switch 22.5mm Dia complete all as specified and directed.
Supply and fixing in repairs copper bus bar for panel as required complete all as specified and directed.
Supply and fixing in repairs 2mm thick sheet metal for existing panel of CRCA sheet duly powder coated including cutting, bending, grinding & refixing panel complete all as specified and directed.
Supply and fixing in repairs current transformer of capacity 200/5 1.5 va complete all as specified and directed.
Supply and fixing in repairs current transformer of capacity 100/5 1.5 va complete all as specified and directed.
Supply and fixing in repairs power & control wiring with PVC flexible copper cable single core of appropiate size as required for better funtioning complete with PVC cable duct & lugs complete for DOL & star-delta fedder complete all as specified and directed.
Supply and fixing in repairs, testing and commissioning totally enclosed weatherproof / waterproof electric CT Fan Motor three phase squirrel cage motor, Capacity 3 HP, 960 RPM, 415V, 50HZ with all connected accessories and all fitting suitable for 60 TR cooling complete all as specified and directed. Make Oswal / Sabar / Hindustan / Bharat Bijlee.
Supply and fixing in repairs CT Fan complete section Fan, Fan Dia1200 mm, connected GI nut bolts and accessories all fitting suitable for 60 TR cooling tower complete all as specified and as directed.
Supply and fixing in repairs all accessories corrosion proof inlet louvers, drift, PVC eliminators, PVC water distribution system , GI nut bolt (included float valve)and all fitting complete all as specified and directed for cooling tower of capacity 60 TR complete all as specified and directed.
Supply and fixing in repairs set of FRP Panels & supporting structure made of hot dip galvanised pipes for 60 TR capacity cooling tower complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-2 using 20 mm graded crushed stone for staging of cooling tower, expansion tank, pipe supports, etc. including necessary form work complete all as specified and directed.
M/S EAGLE ENTERPRISES
R. K. Industrial Fabricators
PAMS ENTERPRISES
Star Electrical
shakti engineering and electrical works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .