| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹1.6 Cr+₹18.5 L (13.4%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | ₹1.6 Cr+₹18.5 L (13.4%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹2.0 Cr+₹62.5 L (45.0%)Rejected-Finance | ₹2.0 Cr+₹62.5 L (45.0%) | L3 | Rejected-Finance Not Being Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
24 Nov 2022, 6:00 pmClosed
Chief Engineer
HQ CE Bathinda Zone
DEMOLITION and RE-CONSTRUCTION OF FIVE BUILDINGS FOR PROVN OF OTM ACCN FOR WKSP (PH-III) AT SURATGARH MIL STATION
2022_MES_557387_1
CE BTZ/SOG/TOKEN-20 OF 2022-23
Open Tender
Civil Works
Lump-sum
335 days
SURATGARH MIL STATION
As per NIT
8 documents required · 8 mandatory
₹1,000
Yes
GE (Army) Suratgarh
₹2.2 L
Yes
15 Dec 2022
13 Oct 2022
26 Nov 2022
13 Oct 2022
24 Nov 2022
12 Nov 2022
Amount
Sch 'A' Sec - I (Building Work) Note:- This schedule is not prepriced by MES hence the rate indicated as Rs 0.00 under col 5. The contractor need to insert their rates & lump sum price in col 6 & 7 respectively as worked out by them.
Sch 'A' Sec - I (Building Work)
Provn of Block of Single JCOs accn (D/S) for 09 JCOs complete all as specified and shown on drgs.
Provn of Block of Tradesman Shop and storage accn and Unit shop complete all as specified and shown on drgs.
Provn of Gate Office complete all as specified and shown on drgs.
Provn of RCC under ground sump of capacity 30000 Gallons complete all as specified and shown on drawings
Subtotal
Sch 'A' Section-II (Part-I) Internal Electrification
Lump sum price worked out by the tenderer for “ Internal Electrification" as listed in Sch 'A' Section-II (Part-I)
Sch 'A' Section-II (Part-II) Internal Electrification
Sub main wiring with 2 single core 6 Sqmm PVC insulated cable with stranded copper conductor drawn in to PVC conduit with and including independent PVC insulated 4 Sqmm single core copper earth wire complete all as specified (conduit and conduit accessories shall be measured and paid for separately)
Earthing complete with galvanized iron earth plate electrode of size 60cmx60cmx0.60cm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to the galvanized earth lead wire 4mm dia by means of GI bolts/nuts/washers and connecting to earth test point and testing on completion, protected by 15mm bore GI light grade pipe. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around. 20mm bore GI light grade pipe for watering and including funnel , wire mesh , CI cover and frame, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR part-I. Note : PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners .
Fixing only tube light fitting any type suitable for 1 x 28 Watt T5 type energy efficient complete including T5 lamp for wall mounting/ hanging from ceiling including PVC insulated PVC sheathed copper conductor flexible cable 2 core of size 24 / 0.2 mm from ceiling rose to connector of tube light complete etc. (Tube light fitting any type including T-5 lamp shall be issued under sch ‘B’ free for fixing)
Fixing only tube light fittings any type 1 x 18 watt dust and vermin proof stove enamelled with clear acrylic cover polyester filled, power factor improvement capacitor, two starters, with starter holder including 1x18 watt fluorescent tube rod with spring loaded rotor type tube holders connector block earthing terminals pre-wired with copper conductor cables fixed to wall for use on 240 volts 50 cycle per second AC single phase supply .complete all as specified. (Tube light fittings any type1 x 18 watt including tube shall be issued under sch ‘B’ free for fixing)
Decorative wall mounted type 1x11 watt luminaries with perforated octagonal CRCA body with opal PMMA diffuser complete with lamp etc of Make Crompton Greaves or equivalent in Philips/ Wipro/ GE/ Havell’s
Fixing only Tube light fitting any type suitable for 4 Feet long 1 x 40 Watt complete including lamp, suitable for fixing on wall or hanging through 19 mm dia MS conduit (conduit shall be measured and paid separately) and flexible wire connection from ceiling rose to the fitting including earth connection (Tube light fitting any type suitable for 4 Feet long 1 x 40 Watt including lamp shall be issued under sch ‘B’ free for fixing)
M C B 'C' series type suitable for 240 volts AC supply 5 to 30 Amps, single pole with over load and short circuit protection and rupturing capacity not less than 9 KA, complete all as specified and directed.
Subtotal
Sch 'A' Section - III Internal Water Supply
Lump sum price worked out by the tenderer for “Internal Water Supply" as listed in Sch 'A' Section - III
Sch 'A' Section - IV Sewage Disposal
Lump sum price worked out by the tenderer for “Sewage Disposal" as listed in Sch 'A' Section - IV
Sch 'A' Section-V PCC Path and Hard Standing
Lump sum price worked out by the tenderer for “PCC Path and Hard Standing" as listed in Sch 'A' Section-V
Sch 'A' Section-VI (Part-I) External Electrification
Lump sum price worked out by the tenderer for “External Electrification" as listed in Sch 'A' Section-VI (Part-I)
Sch 'A' Section-VI (Part-II) External Electrification
Protection to cable with one layer of bricks laid flat with width equal to length of brick and depth equal to thickness of brick, across the cable using old size sub class-B bricks over and including sand cushioning 40 cm wide 230 mm thick (80 mm thick before laying of cable and 150 mm thick after laying of cable) complete all as specified and directed.
Laying and testing only XLPE insulated, PVC sheathed galvanised steel strip or wire armoured UG heavy duty power cable with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3 1/2 core laid in trenches/ducts./through pipes/in floors/under/roads/hard standing /along poles etc complete all as specified and directed. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) (XLPE insulated, LT cable shall be issued under Sch ‘B’)
Laying and testing only XLPE insulated, PVC sheathed galvanised steel strip or wire armoured UG heavy duty power cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laid in trenches/ducts./through pipes/in floors/under/roads/hard standing /along poles etc complete all as specified and directed. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) (XLPE insulated, LT cable shall be issued under Sch ‘B’)
Laying and testing only XLPE insulated, PVC sheathed galvanised steel strip or wire armoured UG heavy duty power cable with aluminium conductor 1100 volts grade cross sectional area 6 Sqmm 2 core laid in trenches/ducts./through pipes/in floors/under/roads/hard standing /along poles etc complete all as specified and directed. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) (XLPE insulated, LT cable shall be issued under Sch ‘B’)
Subtotal
Sch 'A' Section-VII External Water Supply
Lump sum price worked out by the tenderer for “External Water Supply" as listed in Sch 'A' Section-VII
Sch 'A' Section-VIII (Part-I) Solar water heater
Lump sum price worked out by the tenderer for “Solar water heater" as listed in Sch 'A' Section-VIII (Part-I)
Sch 'A' Section-VIII (Part-II) Solar water heater
Fixing, testing and commissioning only of solar water heater system storage type having capacity 200 Ltrs per day including solar panel collector, absorber and other required accessories, insulated stainless steel storage tank (to be placed on roof at a suitable height) with aluminum cladding angle iron structure, cold water tank capacity 500 liters with inter connection between tank and solar panel and necessary masonary work, foundation including electric back up of 5.0 KW and electric panel with MCB and other safety devices such as thermostat, relays etc. complete all as per manufacturer's instructions (Solar water heater 200 Ltr Capacity with HDPE tank 500 Ltr capacity shall be issued under sch ‘B’ free for fixing)
Subtotal
Sch 'A' Section-IX Site clearance and Earth work
Lump sum price worked out by the tenderer for “Site clearance and Earth work" as listed in Sch 'A' Section-IX
Sch 'A' Section-X Demolition, dismantling & taking down
Demolition of existing block of Single JCOs Accn (D/S) for 9 JCOs complete above and below ground level upto 30 CM, including taking down of all fittings, joinery of any description in any position carefully cutting of reinforcement as required to facilitate and returning filling below the GL including removing rubbish material (i.e) concrete and all other unserviceable debris) from site outside the MoD land complete all as directed.
Demolition of existing block of trade smen shop and storage accn and unit shop complete above and below ground level upto 30 CM, including taking down of all fittings, joinery of any description in any position carefully cutting of reinforcement as required to facilitate and returning filling below the GL including removing rubbish material (i.e) concrete and all other unserviceable debris) from site outside the MoD land complete all as directed.
Demolition of existing gate offices above and ground level upto 30 CM, including taking down of all fittings, joinery of any description in any position carefully cutting of reinforcement as required to facilitate and returning filling below the GL including removing rubbish material (i.e) concrete and all other unserviceable debris) from site outside the MoD land complete all as directed.
Demolition of existing RCC under ground sump of capacity 30000 Gallons complete including cutting of reinforcement as required to facilitate and returning filling below the GL including removing surplus rubbish material (i.e) concrete and all other unserviceable debris) from site outside the MoD land complete all as directed. Note for Sl No 43 to 46 : All safety precautions shall be strictly followed by the contractor during demollation of Bldgs and RCC under ground sump, Any loss and damage to nearby existing structure during the demolition shall be made good by the contractor at his own cost and site of work shall be left clean and tidy after demolition.
Subtotal
KHANNA CONSTRUCTIONS
M/s RAMESH KUMAR VERMA CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .