| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.8 LAccepted-AOC KUSUM VATIKA SHIV SHAKTI NAGAR KOKAR RANCHI 834001 | RANCHI | JHARKHAND | 834001 | 1 | Accepted-AOC ok | |
| 2 | 2₹11.2 L+₹24,529.50 (2.23%)Rejected-Finance SANDHYA NIWAS MAGADH COLONY ROAD NO 03 SHERGHATI ROAD PS MAGADH MEDICAL COLLAGE DIST GAYA PIN 823001 BIHAR | GAYA | BIHAR | 823001 | 2 | Rejected-Finance Quoted rate more than L1 | |
| 3 | 3₹11.4 L+₹44,693 (4.06%)Rejected-Finance | 3 | Rejected-Finance Quoted rate more than L1 | |
| 4 | 4₹12.0 L+₹1.0 L (9.14%)Rejected-Finance VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | 4 | Rejected-Finance Quoted rate more than L1 | |
| 5 | 5₹12.1 L+₹1.1 L (10.0%)Rejected-Finance | 5 | Rejected-Finance Quoted rate more than L1 |
Tender Value
Refer Docs
EMD Value
₹34,940
Closing Date
4 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT PO- HOTWAR RANCHI Pin- 834012
SPL REPAIRS TO BLDG NO P-11 OF 523 ASC BN UNDER GE DIPATOLI
2023_MES_613654_1
8000/1922/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Dipatoli
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Dipatoli
₹34,940
Yes
20 Oct 2023
14 Aug 2023
6 Sept 2023
14 Aug 2023
4 Sept 2023
28 Aug 2023
Amount
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L Non- skid colour ceramic tiles,7 to 8mm thick square / rectangular area of each tile exc 0.11 sqm but n exc 0.18sqm in floor over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and directed.
All as per item No 02 here-in before but in skirting including 10mm thick screed bed in CM(1:4) completed all as specified and directed
M&L for coloured glazed ceramic tiles in vertical surface 350mmx250mmx7mm thick over and including 10 mm thick cement plaster in CM (1:4); set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25 mm thick set over and including 15mm thick screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with beewax polishing complete all as specified and as directed.
All as per item No-05 but here-in-before as in skirting over 10mm thick cement plaster in CM 1:4 complete all as specified and as directed.
M&L only mirror polishing of old machine cut kota stone slab flooring, skriting or dado etc and fill the jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mirror polish complete all as specified and as directed.
Demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar, complete all as specified and directed.
M &L Brickwork with fly ash bricks, straright or corved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:4 on wall of brick work or concrete surface, finished fair and even all as specified and directed , complete all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:6 on wall of brick work or concrete surface, finished fair and even all as specified and directed , complete all as specified and directed.
M&L rendering 5 mm thick in cement mortar 1:3 on ceiling of brick or concrete surface, finished fair and even all as specified and directed, complete all as specified and directed.
M&L for 3mm thick wall care putty on wall and rubbing smooth surface as directed.
M&L for preparing the old surfaces by complete removel of existing treatment and applying two coats of cement bsed paint on walls complete all as specified.
M&L for preparing the new plastered surfaces of wall and applying Two coat of cement based paint after one coat of white primer all as specified.
M&L for preparing new plastered surfaces and applying two coats of distember oil emulsion white or tinted after one coat of white primer complete all as specified and directed.
M&L for preparation of new surfaces and applying Three coat of white wash on wall including cornices etc complete all as specified and directed.
M&L for preparing of old surfaces by complete removel of existing treatment and applying two coats of distember oil emulsion on wall complete all as specified and directed.
M&L for preparation of new surfaces and applying three coat of white wash on ceiling including cornices etc complete all as specified and directed.
M&L for preparation of old surfaces and applying one coat of white wash on wall including cornices etc complete all as specified and directed.
All as per Ser item No 21 above but on ceiling , complete all as specified and directed.
M/L for preparing the new surface of any description not otherwise described over 10 cm width or girth on steel surface and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
Material and labour for applying one coat (finishing coat) of synthetic enamel paint including preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth, complete all as specified and directed.
M&L for applying one coats of synthetic enameled paint on old painted wooden surfaces of any description not otherwise described over 10cm width or girth including preparation of surface, complete all as specified and directed.
Material and labour for applying two coats of synthetic enamelled paint over a coat of pink primer including preparation of new wooden surfaces of any description not otherwise described over 10cm width or girth complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sq. m each, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 & n exc 4 sq. m each, complete all as specified and directed.
Taking down shutters of any description n.exc 1 each, complete all as specified and directed.
Taking down shutters of any description exc 1 but n exc 2 sq. m each, complete all as specified and directed.
Material and labour for refixing existing shutter of any descriptions exceeding 1 Sq.m and not exceeding 2 sq.m each in the same opening complete all as specified and as directed.
M&L Glazed and skeleton shutters 35 mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20 (a); for doors supplied and fitted to chowkats complete all as specified and directed.
Supply and fix 30mm thick, 2nd class hard wood, glazed and skeleton window shutters, open rebated and prepared to receive glass or gauge etc divided into square with framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass or gauges etc sizes of members of shutters as specified in SSR Part-I Section 8 clause 8.24 (b) complete all as specified and as directed.
S&F plain framed, panelled shutter (two panel) factory made 35 mm thick of 2nd class HW rail and stylewith lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part-I), Kiln seasoned and chemically pressure treated,. complete all as specified and directed.
S&F 2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame as per specification & drawing complete all as specified and directed.
Material and labour for preparation and treating ends of posts, back of chowkats etc area of tarred exceeding 0.10 Sqm but not exceeding 0.50 Sqm complete all as specified and as directed.
Material and labour for preparation and treating small articles, area tarred not exceeding 0.10 Sqm each such as hold fasts end of posts, back of chowkhats complete all as specified and as directed.
M/L PCC 1:2:4 type B1 20mm grade aggregate as in padding, hold fasts/filling of chowkhats or similar work complete all as specified and as directed .
Supply and fix mild steel flat iron hold fast 25 x 6mm confirming to Fe 290 Gde E-165 complete all as specified and as directed.
Cutting holes in brick walls built in cement mortar for inserting hold fasts depth of embedded portion of hold fast exc half brick but n.exc one brick and making good the dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required , complete all as specified and directed.
Cutting out old bricks or stone masonry walls built in cement or lime mortar, forming toothing for, and bonding new into old work in cement mortar 1:6 including jointing, pointing and making good after fixing of doors and windows or other similar work complete all as specified and directed.
Supply and fix 100mm long aluminium anodised, barrel tower bolts of extruded section, and fixed complete all as specified and as directed.
S&F 150mm long Aluminium anodised barrel tower both of extruded section complete all as specified and as directed.
S&F in repair 100mm size MS butt hinges, medium weight cold rolled complete all as specified and as directed .
S&F as in repairs Aluminium alloy, anodised sliding door bolt of size 250mm with hasp and staple and fixing clips of sheet , complete all as specified and directed.
S&F Aluminium alloy,anodised handle cast type of size 125mm , complete all as specified and directed.
S&F Floor door stoper 150mm of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor , complete all as specified and directed.
Supply and fix 300mm, mild steel, ordinary rat tail rod pattern springs including roller and roller plate fixed complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with oil putty or fixed with beads , complete all as specified and directed.
S&F Sheet glass,4.mm ordinary quality and glazing with in square n exc 0.5 sq. m in each pane , complete all as specified and directed.
Supply and fix 4 mm thick figured glass pin head type glazed with oil putty in square not exceeding 0.5 sqm in each pane complete all as directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average with of aperture 1.18mm and fixed with tinned tack, or galvanised wire staples fixed in repairs, complete all as specified and directed.
Taking down GI tubing and connection including removing to store of 15mm dia complete all as secified and directed
Taking down GI tubing and connection including removing to store of 20mm dia complete all as secified and directed
Supplied and fixed GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors all as specified and directed
Supplied and fixed GI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors all as specified and directed
Disconnecting exisiting tanks setting aside for repairng cleaning and removing al scale and dirt etc from mounths of circulating pipes etc and hoisting .reconnecting and refixing in existing position. Capacity of tanks exc 1000 ltrs and not exc 1000 ltrs , complete all as specified and directed.
S&F in repair 15mm, stop valve/angle valve, cast copper alloy fancy type chromium plasted, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15mm bore with fancy design, complete all as specified and directed.
S&F in repairs bib taps fancy type, cast copper alloy chromium plated 15mm bore with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule and all as specified and directed.
S&F in repairs PVC valveless syphonic action flushing system fancy type low level flushing cistern 10 ltr. Capacity of approved incl flush pipe of 32mm bore and PVC pipe and all as specified and directed.
Supply and fixing in repair vitreous china squatting pan 'Orrisa pattern' size 580x440mm white with integral foot rests any pattern including provn of lime concrete bedding and making connection with & including PVC P Trap, etc complete all as specified and directed.
Supplied and fixed in repair vitreous china WHB white flat back size 550x400mm including Supplied and fixed angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed.
S&F for PTMT Grating round 140mm size fixed in position all as spd and as directed.
S&F PVC SWR) floor trap/nahani trap 75mm dia plain with grating incl jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) completed all as spd and directed
S&F PVC SWR) multi floor trap/nahani trap 75mm dia plain with grating incl jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) completed all as spd and directed
Taking down eaves gutters and rain water pipes (any ize or patterns) including all heads,shoes,bends,swan-necks etc , complete all as specified and directed.
S&F PVC(SWR) pipe 110 mm dia single socketed in any length with rubber ring joints, fixed to wall with and including stack and clamp , complete all as specified and directed.
M&L PVC (SWR) bend of radius 110mm dia , complete all as specified and directed.
S&F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified.
Demolition of cement concrete (unreinforced) of any description in bed concrete not exceeding 15 cm thick below ground level complete all as specified.
Material and Labour for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in sub base of floor, foundation, filling and mass concrete concrete bed to complete all as specified and directed.
Material and labour for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified.
M/L for 75 mm thick cement concrete1:3:6 type C2,using 40 mm stone aggregate finished even & smooth without using extra cement as in plinth protection etc. complete all as specified.
Demolition of reinforced cement concrete in ground floors and pavings n exc 15cm thickness including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
Material and Labour for providing pre-cast cement concrete as in cover slabs for manholes and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20 mm graded crushed stone aggregate and setting in cement mortar 1:6 including necessary form work complete all as specified and directed.
Material and Labour for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Material and Labour for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified.
Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in coping including necessary form work etc. complete all as specified.
Complete removal of all existing roof treatment from RCC roof including old hussion felt, tiles etc and preparation of surface with bire brush and cleaning with water complete all as specified and directed.
M&L for 40 mm thick PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate to roof floor, chajja, RCC shelves etc at water retaning surfaces with WPC and make proper good slope as directed (Note-wpc will be measured and paid seprately)
M&L for preparation of concrete roof surfaces and applying 10mm thick plaster in CM 1:4 and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for applying a coat of bitumen primer @ 0.3L/sqm on roof surfaces , complete all as specified and directed.
M&L for applying 3mm thick APP modified polymeric membrane over the bitumen coat surface weight not less than 3kg/sqm and over lap 100mm and sealed by torch application as per manufacture insteructions complte all as specified and directed
M&L for applying two coats aluminium paint over bituminous surface of membrane , complete all as specified and directed.
M&L for complete removal of existing treatment or preparation of newly plastered wall surfaces, chajja, facia etc and applying two coat weather proof exterior emulsion paint(1st quality)/plastic emulsion paint on walls, chajjas,facia by mechanical applicator of any height of bldigs etc , including primer complete all as specified and as directed .(Weather coat shall be of Asian paint, Apex ,ultima or equivalent as approved by GE)
M&L for providing and applying plaster of paris putty of 2mm thickness over plastered and old different coloured treated wall or ceiling surfaces complete all as specifed and directed
Supply only liquid water proofing compound , complete all as specified and directed.
M&L for repair and rendering 10mm thick in cm 1 :3 on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs all as directed .
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed.
Taking down old/unserviceable MCB DB SPN any capacity by disconnection of electric connection including MCBs,Isolators,etc and making good to disturbed surface complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces.
All as per Ser item No 95 here-in-before but one 3 Pin Socket out let 5 Amps on the same board.
All as per Ser item No 95 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board.
All as per Ser item No 95 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed.
S&F Switch piano type , single pole , one way 15 Amps complete all as specified and directed.
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed.
S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
S&F electronic regulator step type 230 Volts single phase 120 watt complete all as specified and directed.
M&L for lamp holder , PVC /Polycarbonate type with back plate suitabl for batten fittings complete all as specified and directed.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No-106 here-in-before but 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire , complete all as specified and directed.
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
Supply and fix MCB DB TPN 4 way with metal door suitable for Provision of incommer and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles , complete all as specified and directed.
S&F in replacement of isolator DP 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed.
S&F in replacement of LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement of environmental friendly, ultra modern, energy saving, surface mounted, decorative oval plastic bulk head LED light fittings 10 watt capacity ,comprising of high brightness LEDs, IP54 protection complete with all accessories internally pre-wired and inncluding connecting up with 2/3 core twisted flexible copper conductor cable with suitable size of flexible PVC/steel Conduit complete all as specified and directed.
S&F in replacement of building LED security light fitting 40 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed.
M&L for rewinding repair and greshing of ceiling fan of any size sweep single phase. Ceiling fan of any size opening from any height or any locations, fan opening from hook, clamp & refixing the same after cleaning and greshing with required necessary cutting/welding/granding job or required store such as nuts, bolts, washer and suitable length mild steel/ down rod duly making holes etc complete as specified and directed.
S&F for highly efficient LED bulbs, 10 W complete all as specified and directed.
S&F in replacement PVC ventilating air fan single phase 380 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
S&F in replacement PVC ventilating air fan single phase 300 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as directed.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as specified.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick , complete all as specified and directed.
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed.Note : Punned down thickness shall be considered for measurement, complete all as specified and directed.
Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed
M &L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed Note :- i) Earthing test must be carried out in presence of . ii) The earthing result not more than 2 Ohms or disered earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
M/S SURYA BUILDERS
M/S SHAMBHU SHARAN SINGH
M/S KAMLESHWAR SINGH
M/S RAMOTAR SAHU
M/s Ray construction
M/S Sweta Construction
M/s Kundu Enterprises
M/S CITY ENTERPRISES
M/S.R.S.Chauhan and Sons
universal enterprises
M/S AMOD KUMAR PANDEY
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .