Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹66,136
Closing Date
23 Nov 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PHE Rural Mechanical Division
Executive Engineer PHE Rural Mechanical Division Srinagar Balgarden
Supply, Installation, Testing and Commissioning of various balance Electrical/Mechanical works
2020_PHE_108683_1
PHE/MRD/TS/e-tendering/30 of 11/2020
Open Tender
Pumps/Motors
Item Rate
90 days
Jawalapora
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
Convener, purchase committee, Directorate of ISM
₹66,136
27 Nov 2020
7 Nov 2020
24 Nov 2020
7 Nov 2020
23 Nov 2020
7 Nov 2020
180 days
Amount
Supply at site, Installation, testing & commissioning of VERTICAL TURBINE pumping equipment as per technical specifications of Annexure A item no 1
Fabrication, Providing and fitting of 125mm Ø G.I(C-class Pipe), Y-Junction (delivery manifold) as per the technical spwcifiction of Annexure A item no 2
Fabrication, Providing and fitting of Over-Head Gantry with chain pulley block& Platform Base for resting of VT Pumping Units along with Canopy as per the technical spwcifiction of Annexure A item no 3
Supply, Installation, Testing & Commissioning of Aluminium conductor power cable having the following technical specifications of Annxure A item no 4
Fabrication / Providing / Fitting and testing of Modular control panel of appropriate size fabricated out of 14 SWG steel sheet having required openings / vents and fitted with accessories as technical specification of Annexure A item no 5
Providing, Installation, Testing & Commissioning 75KVA voltage controller duly filled with requisite grade of oil &as per technical specifications Annexure A item no 6
Providing and erection of Bajaj/Philips make 09 M long Hot Dip Galvanized octagonal pole (single Section) with allied works as per the technical specification of Annexure A iten no 7
provoding of Tool Kit& Fire Extinguishers: as per the technical pecification of Annexure A item no 8
Electrification of Pump House as per technical specifications of Annexure A item no 9
supply at site, Installation, testing of Inverter & Anti Skid Mats as per technical specifications of Annexure A item no 10
Supply of basic facilities to the staff and P/Fab of retiring bed for operational staff as per the technical specification of Annexure A iten no 11
Supply, Installation, Testing & Commissioning of 50 KVA – 3 Phase air cooled D.G. Set as per the technical specification of Annexure A item no 12
Foundation for DG set
EXCAVATION: Earth work in excavation by mechanical means (Hydraulic excavator) over an area of (16 ft x 10 ft x 1.5 ft) including disposal of excavated earth for a lead upto 50m, disposed earth to be leveled and neatly dressed upto 1.5 ft (All Kinds of Soil) = (16 ft x 10 ft x 1.5 ft)
DUMPING STONE: Dumping Nallah Stone Boulder of nominal size 25mm in horizontal on level= (16 ft x 10 ft x 1 ft)
CENTERING & SHUTTERING: Centering & Shuttering including Strutting, Propping etc& removal of form for Foundations, Footings, Bases of columns etc for mass concrete.=(16’+16’+10’+10’)x(0.5’)+(10’+10’+7’+7’)x(1.5’)
CEMENT CONCRETE (1:2:4): Providing & laying in position cement concrete of 1: 2: 4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size crushed) excluding the cost of Centering & Shuttering all work upto plinth level. ((16ft x 10 ftx0.5 ft) underground + (13 ft x 7 ft x 1.5 ft ) above ground
Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 6 no pillars (2 Pillars of 75mmx75mmx8 ft, 2 Pillars of 75mmx75mmx10 ft, 2 Pillars of 75mmx75mmx12 ft, fabricated out of welding 02 No. of ISMC 75 face to face) with base plates 5" x 5" of thickness 5mm at top and bottom grouted in Concrete block up to a depth of 0.5 ft& 9.5 ft above concrete block; ISMC 75=(8 ft x 4 No + 10 ft x 4 No. 12 ft x 4 No.) + MS plate 5mm = 12x(125mm x 125mm)
Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. ISA 50X50X5 for strengthening of vertical Pillars on all four sides of the shed at top to be welded with vertical Pillars = 1 x (13ft + 8 ft+13ft + 8 ft) + 1 x (8ft + 8ft+8ft).
Providing corrugated C.G.I. Colored sheet (0.63mm) roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G. I limpet washers or with G. I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape where ever required including carriage.
M/S KHAN ELECTRICALS and MECHANICALS WORKS
M/s Shaheen Enterprises
M/s S M ENTERPRISES
Union Equipment and Services
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .