Loading…
Loading…
Tender Value
₹90.1 L
EMD Value
₹1.8 L
Closing Date
1 Jul 2026, 3:00 pm
Provision of alternative control office in the JAT division
433_TELE_38_25_26
433_TELE_38_25_26
Open
3 Months
Neemuch, Madhya Pradesh
₹0
₹1.8 L
9 Jun 2026
9 Jun 2026
17 Jun 2026
A-SUPPLY & INSTALLATION
"Supply of 2 Mb Programmable Primary Digital drop insert multiplexer as per RDSO Specs. IRS TC- 68/2004 (Amnd.1) or latest with conference facility and other stipulation to tender documents and fully wired for 30 channel complete with power supply card, remote control, supervision facility and all other accessories, installation material, manuals etc. It should have facilities to accommodate data interface card in multi drop mode and should be able to support cards needed for video conferencing and ISDN. It shall support NMS installed at Test Room and may 01 operate local/remote location of entire section. It also includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and commissioning of system. The above MUX should be equipped with following circuits: - i) 2 wire/ 4 wire E&M VF circuits ( minimum 16 nos ckts) ii) Subscriber loop circuits ( minimum 4 nos ckts) iii) Exchange loop interface circuits (minimum 8 circuits ) iv) This also includes connecting all pigtails, optical patch cords etc to the SDH equipments. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including supply of wires and connectors termination of all evens on DDF taking PVC cable over runway or a wall and termination of VF interface circuit to the Krone type. MAKE PUNCOM. INSPECTION: RDSO FOR SUPPLY PORTION."
Supply, installation, testing, wiring & commissioning of Layer-2 managed Switch (24 02 ports 10/100/1000 BASE-Tports, 4x 1G SFP+ ports) as per RDSO Specification No RDSO/SPN/TC/83/2020 Revision 2.0 or latest .Switch must be TTP registered and certified .INSPECTION:RDSO
Supply of STP (Shielded Twisted Pair)CAT 6 Cable as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest.INSPECTION:CONSIGNEE.
Supply and installation of Rack mount Servers to work as IP-PBX. The server should be installed with Ubuntu Server LTS 22.04 &Asterisk 18.13.0 LTS or Latest supporting 50ports upto 500 ports. INSPECTION: RITES FOR SUPPLY PORTION.
Supply of 12 Fiber Armored Single mode Optical Fiber ITU - G 652 D. All Dielectric Self Supporting Optical Fiber Cable .Make: FINOLEX, KEC or Better.INSPECTION:CONSIGNEE.
Supply and installation of I/O Box, WhiteJack Cat 6 Keystone UTP with Face Plate- Single (Keystone Jack, Square) & SMB.Make: D-Link or similar. Inspection:Consignee for Supply portion.
Laying of OFC/Power cable/CAT-6 cable PA Cable/Data cable and all the other types of 07 telecom cable and all the other types of telecom cable through HDPE pipe/casing capping/fall ceiling with laying/fixing of HDPE pipe/casing capping/uPVC pipe for connecting/interfacing variouys cpmponents and system integration.This work needs to be done as per Railway Site Engineer.
Excavation of cable trench of 300mm wide and 800mm deep as per approved cable route plan on concrete platform/pukka surface/Track/Pitched/stone/Rocks/ Brick paved 08 surface/chiseling/ blasting of rocks and back filling after laying of HDPE Pipe/Telecom cable, ramming of the soil in trenches and consolidation of soil & restoration of surface. This also includes clearing of temporary obstruction on the selected routes.This work needs to be done as per Railway Site Engineer.
Supply and installation of 4 Wire DTMF Type control HQ Equipment as per RDSO specs IRS-TC 60/2007 Amendment-1 or latest with mike, speaker, hand set and code generator etc. 09 along with numeric key pad LED/LCD display and 12V/40AH Maintenance free dual battery back up with charging system, this should also comprise of mounting arrangement and wiring in control office having inter connection with test room with capability to connect and disconnect control circuits from test room as directed by Railway Site Incharge.INSPECTION: CONSIGNEE.
Supply of control room equipment operated on 48 V DC, with three digit 7 segment 10 LED display and way station calling facility up to 80 stations by pressing push button along with 20 local Telephone calling facility with microphone speaker and handset along with remote patching equipment capacity as per RDSO specification No. RDSO/SPN/TC/66/2007 with ammendment-2, including latest amendment. INSPECTION :RDSO/RITES
Wiring, testing, installation & commissioning of control room HQ equipment for controller's use operated on 48 volt DC. (This includes supply of all materials for execution of work 11 such as PVC casing & caping, fixing materials 10/20 pair indoor PVC cable, , wiring & masonary works except control room HQ equipment which will be procured by Railway against other SOR item & issued to contractor for execution). which will be procured by Railway against other SOR item & issued to contractor for execution).This work needs to be done as per Railway Site Engineer.
Supply of Test room equipment with 19" Rack mounting 48 V DC operated directly interface with OFC 4wire circuit as per RDSO specification no. RDSO/SPN/TC/66/2007 with ammendment-2, including latest amendment.INSPECTION : RDSO
Wiring, testing & installation of Test room equipment on 19" rack. ( (This includes 13 supply of all materials for execution of work such as PVC casing & caping, fixing materials 10/20 pair indoor PVC cable, wiring & masonary works except Test room equipment which will be procured by Railway against other SOR item & issued to contractor for execution).This work needs to be done as per Railway Site Engineer.
Supply, Installation, Configuration, Testing &Commissioning of modular router integrating 2 E1 ports with E1-to-OFC conversion, ideal for bridging legacy telecom systems with 14 modern optical networks. It features 8 Gigabit Ethernet ports (TX/SFP), supports advanced routing protocols (RIP, OSPF, BGP), and includes built-in firewall and encryption (IPSEC, GRE, AES). With dual power supply, IP SLA, SNMP, and NetFlow support, it ensures secure, high-speed, and reliable connectivity for enterprise-grade deployments.INSPECTION : RITES
Supply and installation of 9U, 19 inch rack for pole mount/ wall mount with Fan 15 230VAC 90CFM-02 Nos., AC distribution box (5 socket of 5A, Power On LED indicator, MCB)- 01 No., Shelf Cantilever 1U: 01 No. Cable Manager 1U:01 No. INSPECTION: CONSIGNEE FOR SUPPLY PORTION
Supply, Installation, Testing & Commissioning of 24 Port manageble Layer 3 Switch with 4 Nos of 10G SFP port and 24 Nos of GE port with all accessories as per Spec. No: RDSO/SPN/ TC/83/2020 Ver.2.0 or latest. Switch must be TTP registered and certified .Inspection : RDSO/RITES
Supply, installation ,testing and commissioning of UPS 5 KVA capacity with battery bank for 1 hrs ( ON Line) at required load & battery trolley as per specification no RDSO/PE/SPEC/PS/ 0023, (Rev. '0') 2001 Amdt 4 or latest.INSPECTION : CONSIGNEE
Supply and Installation of 19 inch 42U 600mm Depth Telecom Rack withStandard Accessories (Closed type)Front Door Glass type, all doors should be removable type.INSPECTION : CONSIGNEE
Supply, Installation, Testing and Commissioning of Layer 2 Switch having 8 Nos. 19 10/100/1000 Base-T PoE port with 2 Nos. of SFP port as per RDSO spec.Spec.No: RDSO/SPN/ TC/83/2020 Ver.2.0 or latest. Switch must be TTP registered and certified. INSPECTION : RDSO/ RITES
Supply and installation of wireless access point dual band indoor managed/standalone access, built in antenna, two ports(1GE + 1FE), POE support. This includes all accessories make DIGISOL model DG- WM5307IAC or superior or similar. Inspection: Consignee
Supply of 32 channel NVR as per specs No. 10.2 of RDSO specs No. RDSO/SPN/TC/65/2021 Version:6 or latest including 1 TB Surveillance HDD Inspection: Consignee
Supply,Installation,Testing & Commissioning of Minimum 2MP IP Dome Camera,with 22 HD CMOS HQ sensor minimum 1/3", Focal Length minimum 4mm (1280 x 720) or better @ 25 fps, Min IR Range 30 m.Multiprotcol Supported, Multistreaming Supported password supported,ONVIF Supported,PoE supported, Interface-RJ-45,Ethernet. ( The Camera Must be STQC Complied) Inspection by Consignee.
Supply of SC/APC -LC/PC patch cord (5 meter) (3M, TE connectivity, R&M make or superior) Inspection: Consignee
Supply of SC-APC/SC-APC patch cord (1 meter) (3M, TE connectivity, R&M make or superior) Inspection: Consignee
Supply of cable termination panel rack for fitting of 4 Nos 32-Way U-link panel and mounting arrangemnets for fitting of isolation transformers as per instruction of site Incharge. This also includes a Copper Strip of 450x15x3 mm for Earthing pupose. Inspection: Consignee
Supply of U link Panel complete with 32 Nos of U links.INSPECTION : CONSIGNEE
Supply of U link for 32-U link panel of U link U link protel make or similar. Inspection: Consignee
Installation and wiring of the U link panel above item.This work needs to be done as per Railway Site Engineer.
Supply of basic material to construct unit maintenance free earth as per RDSO Specs. NoRDSO/SPN/197/2008 or latest and conforming to RDSO Drg.No.SDO/ RDSO/E&B/001 dtd.19.09.08 . It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bondingthickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. © Copper strip of 150x25x6 mm, to 29 terminate earth rod= 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 200x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq.mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable . Inspection: CONSIGNEE
Installation of Unit Maintenance Free Earth as supplied under item no. 13.3 of Chapter 13 of SOR . It includes ( i ) Digging the earth to the required depth. (ii)Insertion of electrode. (iii) Filling of earth enhancingcompound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x150 mm to the earth electrodes. All material tools andfeatures required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 30 1.5ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300mm x 25 mm x 6 mm for main equip- potential busbar,ncopper strips of 150 mm x 25 mm x 6 mm sub equip- potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specn.No.RDSO/SPN/197/2008 or latest and conforming to RDSO Drg.No.SDO/RDSO/E&B/001 or latest.Earth to be installed and commissioned as per TAN and OEM or authorized vendor will give commission certificate for commission of Maintenance Free Earth.( NOTE: EARTH TO MEEB ALL CONECTIONS MUST TO BE DONE THROUGH CAD WELDING)
Supply of MODULAR TABLE L X D & H 1200 millimeter X 600millimeter 725 millimeter Brand : ELITZAR Brand or similar Inspection: Consignee
Supply of 220V 50Hz, Power Supply Extention board with having four sockets with independent ON/OFF switch and compatible for both 5 Amp & 16 Amp plug Inspection: Consignee
Supply of power cable 3 core 2.5 sq mm multi strand (36/0.3 mm dia) cable as per IS 694:1990 reaffirmed 1995 or latest suitable for railway electrification area shall be of reputed make like Delton, LAPP, Finolex, or superior. Inspection: Consignee
Supply of RJ-45 CONNECTOR of reputed make such as Dlink or better. Inspection: Consignee
"Supply of PVC conduit pipe (minimum 25 mm dia./1.55 mm thick, 3 metre long and ISI brand) with flexible pipes fixing /laying materials and all other accessories as per requirement. INSPECTION: CONSIGNEE FOR SUPPLY PORTION"
Supply of Standard 19"" Rack mountable, -48V DC Working,Add-Drop STM-4 SDH Equipment conforming to TEC GR supply, 2 Nos. STM 4 ofAggregate L 4.2 Optical interface Modules/Cards, one each for East and West sideTX/RX and 2 nos. of STM-1S1.1 or L1.1 Optical interface modules complete with 5 mts.long Optical Patch Cords, 63E1s card with DDFs and Cable assembly for termination to DDF and minimum 8 nos. of10/100 Base-T EthernetPorts/Fast Ethernet 36 on SDH(EoS) 10/100 Base-T interface Module/Card supporting with LCAS and GFP, Order wire subrack, DDF installation Material,Manuals and other accessories along with CompleteEngineering Order Wire (EOW)arrangement. Note : i) Itshould have necessarysoftware/Firmware for Local/remote Monitoring/Configuration of the equipments through NMS ii)Two no MCBs of appropriaterating along with necessaryconnecting cords and cables forPower Supply Module/Cardshould be supplied andinstaaled as per instruction onsiteincharge.""No.GR/SDH/-010/03JA 2011 (with latest amendment) complete with redundant power. INSPECTION: RDSO FOR SUPPLY PORTION.
Installation and wiring of SDHSTM-4/ADMs primary drop insert multiplexers with all accessories, 19" rack with suitable stand/ platform made of MS angle/CC , power supply board FDF 37 racks (Alreadyinstalled) , DDF with miniature'U' link type for 63E1s , runway ladder , etc. This includes connecting all pig tails, optical patch cords etc. to the SDH equipments. This also includes connecting the SDH and primary MUX equipment with all interface cards to the 48VBus including supply of wiresand connectors , termination ofall E1 on DDF , taking PVC cable over runway or a walland termination of VF interface circuits to the krone type
Supply of C series MCB 2 POLE 32 AMP with metal enclosure. Make Schneider, Legrand, L&T, Havells. Inspection: Consignee
Supply of SMPS based Battery Chargers as per RDSO Spec for Telecom use 48 volts, 39 25 Amps in 2+1 configuration modules of 25 Amps with ultimate expandable capacity 50 Amps, automatic switching between the modules as per RDSO Spec No. RDSO/SPN/TC/23/1999 version 4 or latest along with two potential free contacts.Inspection: RDSO
Installation wiring commissioning of 48 volt / 25Amp SMPS based charger along with the power supply wiring from Power room to equipment room in ladder, wire, SPD, MCB,ladder and any other material required for installation will be arranged by the contractor.
"Supply of maintenance free VRLA secondary cells duly charged of 48V 200AH and 41 each 2.0V when fully charged 200AH capacity along with accessories i.e. inter sell connectivity links/float. 4 Nos.insulators for each cell 24 Nos.of cell per set as per RDSO Spec. IRS/S/93/96A with latest amendments with cuticle steel/hylem tray battery rackto install/house batteries. INSPECTION: RDSO FOR SUPPLY PORTION.
Installation wiring commissioning of 48V/200AHVRLA battery set for Telecom installations
Supply & installation of 100 pair Krone type DP Box with Krone module with complete accessories. Inspection by Consignee
Supply of Digital Clock suitable for Office Complex with GPS Synchronization in standalone mode as per Clause 6 of RDSO SPN TC 62/2008, (Rev 3.0) Amnd. 2 or latest. Inspection: Consignee
"Supply of SFP Optical/Electrical 1 Gbps or100/1000 Mbps Electrical as required. Suitable for supplied switches. INSPECTION: CONSIGNEE FOR SUPPLY PORTION"
"Shifting of all telecom Gears from old telcom control to New RE Control building including all circuits of Control communication, FOIS, Voice logger, Railnet, BSNL etc. and all types of 46 cables like, OFC, PIJF, Cat6 etc. and their termination with supply and installation of Patch/ U-Link Panel with U-Link cables as required by the SSE In- charge.It also included Control communication System map of Jammu division with all details as provided by SSE Incharge.All material required for shifting & installation to be provided by Contractor"
Preparation of cable way 150mm wide at bottom and 200mm deep in rocky area/CC road/Platform and other CC/Stony location and refilling the same (after telecom Cable laying as well 47 as laying PVC pipe which shall be paid separately under different items of the schedule ) with concrete mixture of proportion 1:3:6 all along the trench done rocky area with contractor's own cement mixture, sand, water and other required materials and restoration of earth work as original with tiles/marvel/Granite etc.This work needs to be done as per Railway Site Engineer.
Trenching up to depth of 1200mm with 300mm wide base in all types of soil (Normal 48 soil, Hard soil & Black cotton soil) and backfilling after laying of HDPE pipe /OFC cable and 6 quad/PIJF cable etc. at 1200mm & 1000 mm depth respectively as per Drg No.CORE/S&T/ALD/SK/571/04 . Ramming and consolidation of soil in trenches as well as disposal of the soil if any.
Splicing of fibres OFC Cable and making Splice joint with contractor's own splicing machine and tools and consumables.
Supply of single mode single fiber 10G SFP+ module compatible with switches . INSPECTION: CONSIGNEE.
Supply of Steel Almirah, Height- 1855 MM, Width- 910 MM, Depth- 430 MM etc.Inspection: Consignee
Supply of Caller ID Analogue Phone Having 10 one touch key Make Beetel. (Caller ID 52 Corded Landline Phone with 16 Digit LCD Display & Adjustable contrast,10 One Touch Memory Buttons,2Ways Speaker Phone,Music On Hold, Solid Build Quality, Classic Design) INSPECTION: CONSIGNEE FOR SUPPLY PORTION."
Supply ,Installation, Testing and Commisioning of Hybrid IP-PBX with 1 CPU and 1 DC Power Supply with License for 8 Slots. Expandable up to 120 analog ports, 48 digital ports, 24 Analog 53 Trunks, 999 IP Users, 99 VOIP Trunks, 40 GSM Ports, 8 T1/E1 ISDN PRI ports. The system is configured for 32 Analog Extensions, 32 Digital Ports and PRI card along with software and configuration with CORAL Exchange.Inspection By consignee
Supply, Installation, Configuration, Testing & Commissioning of Router for Tier 2 Locations as per tech specs attached in Annexure -I . Inspection : RDSO
Complete Wiring of COA/FOIS in Control office .This includes all the wiring includes integration of COA/FOIS,supply of cable ties ,labelling and other miscellaneous items that is included in wiring & labelling part.This work needs to be done as per Railway Site Engineer.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ANNEXURE-I-TIER2ROUTERSPECS_11zon.pdf
ATTACHMENT
IRGCC2022ACS7-10.pdf
ATTACHMENT
StandardTenderDocument2022andcorrection.pdf Standard Tender Documents with correction
ATTACHMENT
SpeicalconditionsofworkSignal.pdf
ATTACHMENT
SpecialconditionTelecomm.pdf
ATTACHMENT
IRGCCApril2022andcorrectionSlip.pdf
ATTACHMENT
StandardTenderDocument2022andcorrection.pdf
ATTACHMENT
Download all tender documents and submit your bid