| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC PLOT NO 261 SHANTI KUNJ ALWAR 301415 RAJ | ALWAR | RAJASTHAN | 301415 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹14.5 L+₹89,857 (6.61%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹14.9 L+₹1.3 L (9.43%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹15.9 L+₹2.4 L (17.3%)Rejected-Finance | L4 | Rejected-Finance being 4rth lowest | |
| 5 | L5₹23.4 L+₹9.8 L (72.1%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
Tender Value
Refer Docs
EMD Value
₹49,900
Closing Date
14 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR / MAINT OF WINDOW, SPLIT ACs, WATER/DESERT COOLER, REFRIGEATOR, DEEP FREEZES AND OTHER CONNECTED ITEMS AT AF STN SARSAWA UNDER GE(AF) SARSAWA
2022_MES_530495_3
8122/SAR-24/2022-23
Open Tender
Civil Works
Item Rate
273 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹49,900
Yes
4 Oct 2022
31 Aug 2022
21 Sept 2022
31 Aug 2022
14 Sept 2022
31 Aug 2022
Amount
Servicing of split AC 1.5 /2 TR rating by removal of dust/dirt and carbon particles from indoor and out door unitwith water spray pump duly collected in jacket complete all as specified as directed.
Servicing of window AC 1.5 TR rating by removal of dust/dirt and carbon particles from indoor and out door unitwith water spray pump duly collected in jacket complete all as specified as directed.
S&F in replacement Condenser fan blade made out of aluminium/plastic as per matching to existing suitable for window /split type AC upto 2.0 ton capacity complete all as specified as directed.
S&F in replacement Front grill suitalbe for window type AC upto 2 ton capacity complete all as specified as directed.
S&F in replacement of condensing coil suitable for window type room AC of capacity 1.5 ton.as per sample complete all as specified as directed.
S&F in replacement cooling coil suitable for window type room AC of capacity 1.5 ton as per sample complete all as specified as directed.
S&F in replacement Condensing coil suitable for split type AC of capacity 1.5 ton as per sample complete all as specified as directed.
S & F in replacement cooling coil suitable for split type AC of up to capacity 1.5 ton as per sample complete all as specified as directed.
S&F replacement of Indoor unit suitable for 1.5 TR split type AC complete all as specified as directed. Make:- LG/Daikin/Voltas
S&F replacement of Outdoor unit suitable for 1.5 TR split type AC without compressor. complete all as specified as directed. Make:- LG/Daikin/Voltas
S&F in replacement PCB for window/Split type AC up to 2 Ton capacity suitable for existing complete all as specified as directed.
Supply & fix in replacement MCCB 100 Amp, 4 pole braking capacity 25 KA , thermal Adjustible complete all as specified and as directed. Make:- L&T/Legrand/Havells
Supply & fix in replacement MCCB 125 Amp, 4 pole braking capacity 25 KA, therml Adjustible complete all as specified and as directed. Make:- L&T/Legrand/Havells
Supply & fix in replacement MCCB 250 Amp, 4 pole braking capacity 25 KA thermal Adjustable complete all as specified and as directed. Make:- L&T/Legrand/Havells
S&F in replacement Blower/ condensor fan motor of three speed, testing, commissioning complete suitable for window type 1.5 Ton AC suitable to operate 230V AC all as specified and directed.
S&F in replcement of blower motor suitable for indoor unit rating and capacity as per site requirement for upto 2.0 ton capacity Split type AC complete all as specified and directed.
All same as per ser item No 16 above here in before but suitable for condensor fan of out door unit of split AC up to 2.0 TR capacity complete all as specified as directed.
S&F in replacement Blower fan made out of platic suitable for indoor unit split type AC upto 2.0 ton capacity complete all as specified as directed.
Supply & fix in replacement Electronic starting circuit relay circuit for 16.5 TR package type AC (As per sample) complete all as specified and as directed.
Supply & fix in replacement Electronic starting circuit relay circuit for 8.75 TR compressor (As per sample) complete all as specified and as directed.
Supply & fix in replacement sealed unit compressor of cap 5.5 TR suitable for package type AC complete all as specified and as directed. Make:- Blustar/Voltas/Kirloskar
Supply & fix in replacement sealed unit compressor of cap 4.5 TR suitable for package type AC complete all as specified and as directed. Make:- Blustar/Voltas/Kirloskar
Suuply & Fix in replacement of genuine company sealed compressor suitable for any type of existing make for split/ window type AC capacity 1.5 Ton with all fixing accessories complete all as specified and as directed by Engineer-in-charge. Note : Repaired and repainted compressor not accepted only genuine compressor are accepted. with test report and one year warranty certificate from OEM. Make:- Hitachi/LG/Whirlpool
All same as per ser item No.23 here-in-before but of split/ window type AC capacity 2.0 Ton complete all as specified as directed. Make:- Hitachi/LG/Whirlpool
S&F in replacement Running Capacitor of 06-45 Mfd suitable for window / split type AC complete all as specified as directed. Make:- Concap/Tibcon/Epcos
S&F in replacement Wiring kit suitable for 1.5 to 2.0 ton capacity AC complete all as specified as directed.
S&F in replacement Air filter of existing make : synthetic, PVC suitable for 1.5 to 2.0 ton capacity AC window/Split type complete all as specified as directed.
S&F in replacement Refrigerant gas filter and capilary assembly complete suitable for AC upto 2 ton capacity complete all as specified as directed.
S&F in replacement gas charging pin valve complete all as specified as directed.
Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another locatiion in the same or other building in the complex as directed complete with make opening of suitable size in wall/window as per site requirement complete all as specified as directed.
Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischare copper pipe and shifting to another locatiion in the same or other building in the complex as directed .
Supply and charging the gas refrigerant (including refrigerant) of window type AC upto 1.5 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, injection of nitrogen to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.
All same as per item No 32 here-in-before but split type AC up to 2 TR capacity complete all as specified as directed.
M&L for replacement of split valve ¼” for split AC 1.5 ton capacity complete all as specified as directed.
All same as per item no 34 above here in before but 1/2" complete all as specified as directed.
S&F in replacement compressor shut off valve 3/8" for split AC 1.5 ton capacity complete all as specified as directed.
S&F in replacement compressor shut off valve 3/8" for split AC 2 ton capacity complete all as specified as directed.
S & F in replacement of Copper tubing of size 1/4" suitble for any type of split type AC complete all as specified and directed.
All same as per Ser item No. 38 but size 1/2" complete all as specified as directed.
All same as per Ser item No. 38 but size 3/8" complete all as specified as directed.
All same as per Ser item No. 38 but size 5/8" complete all as specified as directed.
S&F in replacement PVC pipe of suitable size to drain out condensation water for any type of AC including necessary clamping arrangement to wall.
S&F in replacement PVC conduit 50mm dia including all clamps, tees & accessories and connecting the condensate pipe of Acs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey. MAKE- AKG/National
S&F in replacement of synthetic rubber tube for thermal insulation for refrigerant copper piping of size 1/4" internal dia split type AC complete all as specified and directed suitable for the under mentioned sizes. MAKE- KAIFLEX
All same as per ser item No. 44 but size 1/2" complete all as specified as directed.
All same as per ser item No. 44 but size 3/8" complete all as specified as directed.
All same as per ser item No. 44 but size 5/8" complete all as specified as directed.
S&F in replacement of window AC kit complete chasis including cooling coil, condensing coil, fan motor, blower, condensing fan and complete body without compressor suitable for window AC of capacity upto 1.5 ton complete all as specified and as diretced by Engineer-in-charge
S&F in replacement of remote for window / split type AC as per matching existing complete all as specified as directed.
S&F in replacement metal plug top 2 pole and earth, 20 Amps, 250 volts suitalbe for sheet metal enslousers complete all as specified and directed.
S&F in repalcement metal clad socket 2 pole and earth, 20 Amps 250 volts suitalbe for sheet metal enclusers complete all as specified and directed.
S&F in replacement MCB single pole, 6-32 Amps, 10 KA 240 Volts, 50 HZ type. C series complete all as specified as directed. Make:- L&T/Legrand/Havells
S&F in replacement sheet metal enclosure single pole and neutral with 2 pin and earth socket complete with one single pole MCB 6- 32 A, 10 KA 'C' series complete all as specified as directed. Make:- Havells/ Endo-Asian/Legarand
S&F in replacement of PVC insulated FRLS sheathed flexible copper conductor 3 core 1100 volts round grade of size 2.50 Sqmm complete all as specified and directed. Make:- Finolex/havells/KEI
S&F in replacement of PVC insulated FRLS flexible copper conductor cable 1100 volts round grade, 3 core of size 1.5 Sqmm complete all all as specified and directed. Make:- Finolex/havells/KEI
S&F in replacement of PVC insulated FRLS flexible copper conductor single core 1100 volts round grade of size 2.50 Sqmm complete all as specified and directed. Make:- Finolex/havells/KEI
S&F in replacement of PVC insulated FRLS flexible copper conductor single core 1100 volts round grade of size 4 Sqmm complete all as specified and directed.Make RR KABEL/Havells/Finolex
S&F in replacement of PVC insulated FRLS flexible copper conductor cable 1100 volts grade, single core of size 1.5 Sqmm complete all all as specified and directed.
M&L in replaqcement sub main wiring with two run of single core strated copper conductor FRLS cable of size 2.5 Sqmm and 2.5 Sqmm copper conductor cable as earth continuity conductor drawn in existing conduit or PVC casing capping complete all as directed. Make:- Finolex/havells/KEI Note : 2 Run of 2.5 Sqmm + 1 Run of Earthwire shall be measured on one run.
M&L in replaqcement sub main wiring with two run of single core strated copper conductor FRLS cable of size 4 Sqmm and 4 Sqmm copper conductor cable as earth continuity conductor drawn in existing conduit or PVC casing capping complete all as directed.Make:- Finolex/havells/KEI Note : 2 Run of 2.5 Sqmm + 1 Run of Earthwire shall be measured on one run.
S&F in replacement AC stand suitable for out door AC unit up to cap of 2 ton capacityany type complete with fastners stove enamelledcomplete all as specified as directed.
M&L for repair to refrigerator any capacity upto 310 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified as directed.
M&L for repair to deep freezer any capacity upto 425 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified as directed.
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside, greasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule complete all as specified as directed.
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets and water tank with rubber paint after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed by Engr-in-Charge. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting complete all as specified as directed.
S&F in replacement of wood wool pad (set of three) heavy duty for desert cooler complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of desert cooler sub mersible water pump 18 watt complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing complete all as specified as directed.
S&F in replacement desert cooler fan motor 145 watt,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified as directed.
S&F in replacement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as directed by Engr-in-Charge.
S&F in replacement plug top 3 pin 5 Amps complete all as specified as directed.
S&F in replacement motor capacitor 2.5/3.15/4 Mfd complete all as specified as directed.
S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity upto 4000 Cfm complete all as specified as directed.
S&F in replacement of body without side panels made out of galvanised iron sheets of of 18 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge.
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge.
S&F in replacement of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as directed by Engr-in-Charge.
S&F in replacement of PVC rubber pipe 15mm bore heavy duty including pvc elbow threaded suitable for insertion in flexible PVC pipe complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of PVC water distributor four way complete all as specified and as directed by Engineer-in-charge.
M&L for Servicing of voltage stabilizer AC single phase 2 to 5 KVA of any make by opening of body, cleaning internally checking and tightening of all terminal connections including replacement of worn out terminals connectors, screw, bolts etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement of transformer of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of buck and boost relay of voltage stabilizer of capacity upto 5KVA complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of electronic panel PCB of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of timer switch circuit of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of trigger transformer of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of voltmeter of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
Supply and charging the green gas in the water cooler of any make and capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.
S&F in replacement thermostat switch for water cooler of any make & size complete all as specified and directed.
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of zinc oxide primer by spray painting.
S&F in replacement fan motor ISI marked suitalbe for water cooler capacity upto 40/80 ltrs of any make complete all as specified and directed.
S&F in replacement of condenser fan of any make suitable for water cooler upto 40/80 ltrs capacity complete all as specified and directed.
S&F in replacement 15 mm dia PTMT connection of length upto 600mm with nuts on both ends complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 40/80 ltrs capacity complete all as specifed and directed.
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 40/80 ltrs capacity complete all as specifed and directed.
S&F in replacement company sealed compressor unit of water coolers of capacity 40/ 80 ltrs complete all as specified as directed.
S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding fastening angles, as necessary gusset plates, rivetingetc conforming to Fe.29.Gde-E-165
M&L Painting to new or previously untreated steel surfaces of any description over 10 cm in width or girth with two coats of synthetic enamel paint over a coat of zinc chromic primer in camaflage pattern or plain or pattern as decided by Engir-in-charge
NAQLI LAL SHARMA AND ARUN SHARMA
PANWAR CONSTRUCTIONS
ISHWAR ELECTRICALS AND PROCESS SERVICES
Sharma Electrical and Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .