Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.8 LAccepted-AOC | L-1 | Accepted-AOC Lowest qualified bidder. Hence being awarded | |
| 2 | L-2₹17.0 L+₹2.2 L (14.8%)Rejected-AOC | L-2 | Rejected-AOC Not qualified L-1 bidder | |
| 3 | L-3₹18.9 L+₹4.1 L (27.6%)Rejected-AOC C O REKHABAI NAITAM KILLA WARD BALLARPUR DIST CHANDRAPUR 442701 | BALLARPUR | CHANDRAPUR | MAHARASHTRA | 442701 | L-3 | Rejected-AOC Not qualified L-1 bidder |
Tender Value
₹19.9 L
EMD Value
₹25,000
Closing Date
27 Jul 2023, 3:30 pmClosed
Shri. Nitin Naik
OFFICE OF THE AREA GENERAL MANAGER WCL BALLARPUR AREA P.O. SASTI TA. RAJURA DIST. CHANDRAPUR (MS) PIN 442905
Providing water supply arrangement to Gouri Pouni Merger CHP by HDPE pipe line and Submerssible pump for dust suppression at Gouri Pouni Merger OCM under Gouri Sub Area .
2023_WCL_283806_1
ba3650-civ-e51-2023-24/242
Open Tender
Water Supply/ Sanitation Works
Item Rate
45 days
WCL Ballarpur Area
As per NIT
3 documents required · 3 mandatory
₹25,000
22 Aug 2023
17 Jul 2023
28 Jul 2023
17 Jul 2023
27 Jul 2023
17 Jul 2023
17 Jul 2023 - 24 Jul 2023
Amount
Supplyig ,installaing ,testing and commissioing suitable ponton (Dept Provided) with perfect aligning proper levelling of openwell/ submersible pumphaving capacity not less than 1000 LPM at minimum 130m head 70 HP 52 KW. Phase 415 volt.50 Hz or of suitable HP complte as per detailed techinical specification attatched as per directionh of Engineer in charge
Supplying & erecting automatic control panel for 3ph 415 volt.A.C. Submersible centrifugal pump set up to 30 HP consisting of Star Delta sarter having realy range 30-50 Amp, S.P.P. Combined ammeter/ voltmeter, phase indicating lamp encloased. In CRCA power coated Vibration proof enclosure with IP 54 protection. Control panel should offer single phasing,phase reversal.phase imbalance etc.
Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :100 mm diameter Class I
Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) With by pass arrangement - PN -1 100 mm.
Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.16 Kg/Sq. cm :90 mm
Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II 90 mm
Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete.Air Valve Single Ball Flanged / Screwed Type - PN -1 50 mm.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kind of Soil
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 100 mm
Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves).Air Valve Single Ball (PN-1 and PN - 1.6) 50 mm.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Total impact of GST for the purpose of CTC
P S Salve
Omprakash Yadav
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .