Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC 790 STREET NO 1 PATEL NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.5 L+₹2.0 L (31.4%)Rejected-Finance DSS 110 GROUND FLOOR SHOPPING COMPLEX SECTOR 15 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical HOUSE NO 966 URBAN ESTATE 2 125005 | HISAR | HARYANA | 125005 | - | Rejected-Technical Not Eligible | |
| 4 | Rejected-Technical 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | - | Rejected-Technical Not Eligible |
Tender Value
₹7.5 L
EMD Value
₹14,944
Closing Date
28 Feb 2022, 5:00 pmClosed
EXECUTIVE ENGINEER ELECT DIV PWD B AND R HISAR
EXECUTIVE ENGINEER ELECT DIV PWD B AND R HISAR
INSATLLATION OF PSA PLANT IN CIVIL HOSPITAL HISAR (PDG E.I. INTERAL ONLY)
2022_HRY_207988_1
Eect-GGN/Elect-HSR/100287
Open Tender
Electrical Works
Works
120 days
Hisar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹14,944
Yes
22 Jul 2022
12 Feb 2022
1 Mar 2022
12 Feb 2022
28 Feb 2022
12 Feb 2022
Amount
COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) Wiring for Light/Fan/call bell point in 1.5 sum FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. (Her 23.1.1) Group C (Her 23.1.1.3)
Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sum FRLS copper wire and 1 no 1.5 Sam FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required (HSR 23.1.4) Group C (HSR 23.1.4.3)
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sum FRLS copper wire and 1 no 4 Sam FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required (HSR 23.1.5) Group C (HSR 23.1.5.3)
Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. (HSR 23.6.6) MS Pipe of 20 mm dia. (HSR 23.6.6.1)
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labor and material required for the job complete in all respects.(HSR 23.8.10) 6 Modules (HSR 23.8.10.4)
12 Modules (HSR 23.8.10.6)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 23.8.11) 5 amp 1 way switch (HSR 23.8.11.1)
15 amp 1 way switch (HSR 23.8.11.3)
5 amp Socket (HSR 23.8.11.4)
15 amp 6 pin Socket (HSR 23.8.11.5)
Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work. (HSR 23.9)
Supply, erection and fixing of 12 mm thick ply wood board having a circular /rectangular hole etc as required including the cost of making hole, nuts and bolts, painting and other petty material with all labor etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. (HSR 23.13)
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. (HSR 23.22.1) 4 pole MCCB 200 to 250 amp, 25 KA (HSR 23.22.1.11)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- (HSR 23.22.5) 40 amp to 63 amp. MCB's TRIPLE POLE (HSR 23.22.5.6)
LT CABLE (HSR 24.2) Laying of underground cable in pipe /existing open/closed trench etc as (HSR 24.2.4) 16 Sq mm to 35 sqmm 2 to 4 Core (HSR 24.2.4.2)
185 sqmm to 240 sqmm 3 to 3½ Core (HSR 24.2.4.4)
(Q) Earthing (HSR 24.1) Earthing with tinned copper earth plate 600 x 600 x 6 mm thick including accessories and providing masory enclosures with cover plate having locking arrangment and watering pipe etc (but without charcoal or core and salt) etc complete as required . (HSR 24.1.5)
Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode. (HSR 24.1.5)
providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connection etc as required with all labour and materials (HSR 24.1.9)
Supply and erection of suitable compression type brass cable glands for underground Cable. (HSR 24.2.7) 10 sqmm to 16 sqmm Cable 2 to 4 Core (HSR 24.2.7.2)
120 sqmm to 185 sqmm Cable 3 to 32 Core (HSR 24.2.7.5)
RCC FOUNDATIONS FOR DG SET (HSR 24.7) Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1.8x1.0m) Unit: per cum Note: As size and dynamic load of DG sets vary from manufacturer to manufacturer, item of DG set foundation have been included on the basis of cubic contents of RCC. 250 KVA DG Set (HSR 24.7.5)
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. (HSR 23.22) Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA (HSR 23.22.1.11)
SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings (HSR 23.22.8) 300 amp 415 volts (HSR 23.22.8.4)
Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- (HSR 24.2.2) 50 Sq mm to 150 sqmm 2 to 4 Core. (HSR 24.2.2.3)
185 sqmm to 240 sqmm 3 to 3½ Core (HSR 24.2.2.4)
HDPE Pipe: S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. (HSR 24.5.2) DWC/HDPE pipe 145/123 mm outer dial inner dia
Non Schedule items:- Supply of Under Ground LT Power Cables of Aluminium Conductor complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make:- Havell's/ Grandlay/ RR Kabel. 16 Sqmm 4 Core Ard. Cable
50 Sqmm 3.5 Core Ard. Cable
185 Sqmm 3.5 Core Ard. Cable
Supply and erection of Double door sheet, steel superline/ Powerline/ Loadline TPN Vertical distribution boards suitable for TP/ FP veritcal MCCBs 25 KA MCCB upto 125 amp as incomer (but without cost of MCCBs) fitted with busbars, Neutral links,& Blanking plates complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (C&S/ Indoasian/Siemens). 4 Way Vertical
Supply and erection of 40 W LED batten with aluminium base heat shink complete of Dura Batten 50000 Bussiness Hours, 4600 Lumens. complete with all accessories and labour to complete the job upto the entire satisfaction of Engineer-in-charge of the work. (Make:- Bajaj/ Havell's/ Philpls/)
Supply and erection of AC Ceiling fan without regulator 36/48" (900/1200mm) complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make:- Havell's Model Orion and equivallant make Orient.
Supply of 1 KVA UPS invertor online with 1 hour backup complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make:- ELNOVA/ Microtek/ Etone.
S/E of 150 W LED Flood light luminaries with high power LED Minimum 110 lumens per watt Luminaries with secondary optics made in pressure die cast aluminum housing and Heat sink in aluminum extrusion with IP-65/66 with front toughened glass including the all petty material & labour for errection, complete in all respect of upto the entire satisfaction of the Engineer-in-Charge of the work. Make: Philps/ Bajaj/ Wipro/ Havell's.
Suppy of exhaust fans of 12" (300 mm) approved make complete in all respect. Make:- Havell's/ Orient make.
M/S SHIV ELECTRICAL AND CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .