Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC OPP MARICAR HOSPITAL JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.9 L+₹1.6 L (4.67%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹35.4 L+₹2.1 L (6.29%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹37.9 L+₹4.5 L (13.6%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
3 Dec 2020, 6:00 pmClosed
GE, Minniebay, Junglighat (PO), Port Blair -744103
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR / MAINT OF EXTERNAL WATER SUPPLY, STREET LIGHTS, INTERNAL ELECTRIFICATION AND CONNECTED WORKS AT BROOKSHABAD UNDER AGE E/M II AT GE MINNIEBAY, PORT BLAIR
2020_MES_391346_1
8901/E8
Open Tender
Coal Works
Item Rate
240 days
GE, Minniebay, Junglighat (PO), Port Blair -744103
As per NIT
8 documents required · 8 mandatory
₹500
GE Minniebay
₹80,000
Yes
30 Jan 2021
31 Oct 2020
7 Dec 2020
31 Oct 2020
3 Dec 2020
14 Nov 2020
Amount
M&L for detecting and repairing leakages in CI/DI pipelines of size 250mm/200mm bore, taking up unserviceable/ serviceable CI/DI water mains 250 mm / 200mm bore with spigot and socket ends (including fittings) of any type/grade and joints from trenches and laying new DI pipelines of size 250mm/ 200mm bore in trenches or placing on pillars/supports including testing on completion complete all as specified and as directed at site indlcuing the the following : - (a) Excavation and earthwork in soil / mud by using machinery/ labour to suitable length (approx 10 metre) and forming bund with excavated soil to avoid sea / raw water entering into the working area including pumping / bailing out water by using portable diesel engine driven pumpset. (b) Cutting of CI/DI pipe of size 250mm/ 200mm bore after thorough inspection for the damaged pipeline including disconnecting / dismantling. (c) Taking out CI/DI pipe with CI/DI specials after removing from joints / burning out joints and recovering lead at both ends with the help of Hydraulic Crane or other machinery and keeping aside for further disposal (d) Cutting the new pipe into pieces as per requirement and laying using machinery (e) Aligning the pipe line as per site condition, inserting the CI/DI collar suitable for 250mm / 200mm bore pipe. (f) Attending the repair work within a minimum period as specified by Engineer-in-Charge.
All as per item No 01 above but 150mm bore .
All as per item No 01 above but 100 / 80mm bore .
M&L for attending of water supply complaints for any leakage / blockage in GI pipe lines of size 20mm / 25mm bore taking up serviceable / unserviceable GI water pipe lines all fittings/fixtures from trench including supply and laying GI tubing 20mm/25mm bore up to 1 mtr length (max) including necesssary cutting, threading and replacement of unserviceable GI fittings such as GI socket /Nipple/union socket / Tee /reducer etc. suitable for 20mm/25mm including necessary excavation and earth work up to 1 Cum to repair the leakage / clearing the blockage in the pipe line and testing on completion complete all as directed at site NOTE : Excavation more than 1 Cum and GI fittings shall be measured and paid seperately under relevent item of this schedule
All as per item No 4 above but 40mm / 50mm bore GI pipe line.
Note for item No-1 to 5:- (a) Spares will be measured and paid separately under relavant items. (b) The break down complaint shall be attended within 2 after the intimation of Engr-in-charge or concern JE E/M by telephonically / verbally / by writing (c) Not attending of complaint within two hours after intimation shall lead to recovery from subsequent payment in the following manner :- (i) Attending within 2 to 4 Hours - Rs. 2000.00. (ii) Attending within 4 to 6 Hours- Rs. 4000.00 (iii) Attending within 6 to 8 Hours- Rs. 8000.00. (iv) Attending after 8 Hours - Rs. 10,000.00 (v) The maximum recovery will be Rs. 50,000.00 plus the expenditure incurred for rectification of the same by any other means.
Supply, laying jointing, testing in repairs DI pipe with spigot socketed ends centrifugally cast, class K - 9 conforming to IS-8329 laid in trenches of the following sizes all as specified and directed by Engineer-in-Charge. Note : Joints and CI fittings shall be measured and paid separately under relevent items of this schedule.
80 mm dia pipe
100 mm dia pipe
150 mm dia pipe
200 mm dia pipe
250 mm dia pipe
M&L for CI / DI fittings in repairs for spigot and socketed pipes of class 'A' such as bends any type, radius and angle), tapers any type (straight , bend, increasing/ decreasing or double socket, etc.,), tee pieces, single branch, 'Y ' juction, double branch, cross (all sockets or socket and spigot) collers, caps and plugs, etc., in new position with connecting pieces for pipes 350mm / 400mm bore CI/DI pipe line complete all as specified and as directed.
M&L for Joint with rubber gasket (Tyton) suitable for spigot and socket pipe and fitting of 250mm bore CI / DI pipe complete all as specified and as directed.
All as per item No 8 above but 200mm bore .
All as per item No 8 above but 150mm bore .
All as per item No 8 above but 100mm bore .
All as per item No 8 above but 80mm bore .
M&L Lead Wool Joint suitable for spigot and socket pipe and fitting of 250mm bore CI/ DI pipe complete all as specified and as directed.
All as per item No 13 above but 200mm bore
All as per item No 13 above but 150mm bore
All as per item No 13 above but 100mm bore
All as per item No 13 above but 80mm bore
M&L Run Lead Joint suitable for spigot and socket pipe and fitting of 250mm bore CI/ DI pipe complete all as specified and as directed.
All as per item No 18 above but 200mm bore
All as per item No 18 above but 150mm bore
All as per item No 18 above but 100mm bore
All as per item No 18 above but 80mm bore
M&L for Joint with rubber or fibre board gasket suitable for flanged pipe and fitting of 250mm bore CI/ DI pipe complete all as specified and as directed.
All as per item No 23 above but 200mm bore
All as per item No 23 above but 150mm bore
All as per item No 23 above but 100mm bore
All as per item No 23 above but 80mm bore
M&L for cutting CI/DI pipes 250mm bore in position for insertion of new tees, branches, etc., and reducing to required length before laying all as specified and as directed.
All as per item No 28 above but 200mm bore .
All as per item No 28 above but 150mm bore .
All as per item No 28 above but 100mm bore .
All as per item No 28 above but 80mm bore .
S&F flanged Non Return Valve (NRV) suitable for 200mm bore pipe flap type, cast iron body, class PN 1.6, confirming to IS, provision with 3mm thick rubber gasket on both sides of the flanges, bolts and nuts complete including dismantling of unserviceable valve all as specified and as directed by Engr-in-Charge.
All as per item No 33 above but 80mm bore pipe
Excavating in trenches in soft/loose soil, n exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cessapits, manholes, pier holes, etc n exc 10 Sqm on plan and getting out all as specified and directed by Engr-in-Charge.
All as per item No 35 above but exc 1.5m in depth
Excavating in trenches in hard/dense soil, n exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cessapits, manholes, pier holes, etc n exc 10 Sqm on plan and getting out all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in any type of soil all as specified and directed.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point in any type of soil.
Supplying, laying and fixing in replacement, GI water tubing, medium grade, of following size confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing complete all as specified and as directed
20mm dia
25mm dia
40mm dia
50mm dia
S&F in replacement Gun Metal, globe or gate valves with iron wheel head screwed both ends for iron pipe for the following sizes :
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
S&F in replacement of sluice valve suitable for 80mm bore pipe with stainless steel spindle and iron wheel head long body class PIN 1.6 complete with rubber gaskets, nut and bolts of suitable size, ISI marked conforming to IS-14846 complete including all as specified and directed by the Engr-in-Charge
All as per item No 42 above but suitable for 100mm bore pipe
All as per item No 42 above but suitable for 150mm bore pipe
All as per item No 42 above but suitable for 200/ 250mm bore pipe
M&L in repair, Mild steel, plain, black sheet 3.15mm thick in cover to water tanks, cover to valve chambers, etc and in similar work, as per site requirement welded to frame, cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members etc, with plain 40mm lap joints or welded / riveted seams including bending, turning up, mitred angles, stopped ends, outlets, locking arrangement etc and including preparation and painting with two coats of synthetic enamel paint black color/ shade over a coat of redoxide primer as required complete all as specified and as specified and directed by Engr-in-Charge
Taking down UNSV sluice valves / NRV and Re-fixing the same in its original position / location with flanged ends including necessary cleaning, resetting & minor repairs for its smooth functioning, any pattern of following sizes
80mm dia
100mm dia
150mm dia
200mm dia
250mm dia
M & L for repacking stuffing box of sluice valve spindle including taking apart and reassembling of the following sizes:-
80mm dia
100mm dia
150mm dia
200mm dia
250mm dia
M & L for takingout sluice valve, refacing, regrinding and refixing including taking apart & complete reassembling of the following sizes:-
80mm dia
100mm dia
150mm dia
200mm dia
250mm dia
Demolition of precast block masnory walls built in cement mortar complete all as specified and directed.
M&L for precast cement concrete solid block masonry exc 10cm in width type C1, 1:3:6 (using 20mm stone aggregate ) set in CM (1:6)
M&L for rendering 10mm thick in CM (1:4) on fair faces of concrete internal wall surface finished even and smooth (without using extra cement)
M&L for providing cement concrete Type B1 1:2:4 (using 20mm graded aggregate ) as in coping, bedplates, valve chambers etc all as specified and directed.
M&L rendering 15mm thick in CM (1:4) on fair face of concrete external wall surfaces finished even and smooth (using extra cement)
S&F in replacement of Ball valves high pressure with Epoxy coated aluminum rod & high density plastic ball screwed for iron pipe of following sizes all as specified and directed by Engr-in-Charge
25 mm bore
20 mm bore
Supply only union socket GI medium grade of following sizes :-
20mm dia
25mm dia
40mm dia
50mm dia
Supply only Socket GI medium grade of following sizes :-
20mm dia
25mm dia
40mm dia
50mm dia
Supply only GI Nipple 6" long of following sizes :-
20mm dia
25mm dia
40mm dia
50mm dia
Supply only GI Tee Reducers medium grade of following sizes :-
Cleaning of service tanks installed on roofs of multistoryed buildings at Brookshabad area by emptying the tanks, removing scale, dirt and all other foreign materials deposited inside nipples, on side of walls and bottom of the tanks by scrapping and brushing with wire brush , and pressure pump, cleaning with bleaching powder slurry and allowed to dry and then washing the tank with fresh water, Checking and removing Airlock if any on next day after cleaning of the tank, cleaning of vegetation, etc, on surrounding RCC slab where the tank is resting and writing on the tank the date of cleaning, capacity of tank, etc, with synthetic enamel paint of 10 cm high and 6 cm width letters in white color, over a black background of size 450mm x 300mm complete all as specified and directed by Engr-in-Charge Notes :- Rate quoted is deemed to be including the following :- (a) Maintenance of Register with details of tanks cleaned with building No, and provisions of signature of Users, JE, AGE, Contractor & Remarks.
Service tanks of capacity n exc 250 ltrs
Service tank of capacity exc 500 Ltr but n exc 1000 Ltr
S&F in replacement of Rotational moulded polyetheylene (HDPE) Water Tanks, Cylindrical & Vertical Type, double layered, ISI marked, hoisted and fixed in position with PVC cover including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed of following capacities :
500 Ltr Capacity
1000 Ltr Capacity
2000 Ltr Capacity
S&F in replacement PVC tank cover suitable for service over head tank including necessary fixing arrangements of 500/750/1000 Ltr capacity complete all as specified and directed by Engr-in-Charge
M&L for painting to GI / CI water pipeline including Sluice valves, NRV etc with two coat of synthetic enamel paint of black colour / shade or approved colour duly preparing the existing painted surfaces of 80 / 100 / 150mm dia pipes all as specified and directed by the Engr-in-Charge
M&L for Cleaning of RCC overhead reservoirs / semi under ground sump/static water tank / Over head tank up to 30 Mtr height of following capacity situated at Brookshabad area by emptying the reservoirs, taking down the scale / sludge /mud / algae formed including and other foreign materials got deposited on side of walls and bottom of the tanks by scrapping and brushing with wire brush, cleaning with pressure pump, washing with bleaching powder slurry and allowing to dry and then washing and cleaning the tank with fresh water including applying one coat of white wash on internal surface of reservoirs/sumps and written details on tanks like date of cleaning, capacity of tanks etc on the out side of the tank with synthetic enamel paint with letter size 20cm high, 10cm width in white colour, over a black background of size 120 x 80cm all as specified and directed. Note :- Quoted rate shall be include the following:- (a) The photographs of OHR, sumps before and after cleaning be submitted to Engineer-in-charge for records. (b) Sample testing of every OHR / UG sumps water before and after cleaning from auth Govt agency.
Semi underground sump of capacity 2.5 lakhs ltrs
Semi underground sump of capacity 1.5 lakhs ltrs
Supply, fixing & testing in replacement non return Valve (NRV) size of 250 mm dia suitable for any type / size pipe complete all as specified and directed by Engr-in-Charge
Supply, fixing & testing in replacement non return Valve (NRV) size of 65 mm dia suitable for any type/size pipe complete all as specified and directed by Engr-in-Charge
Supply, fixing & testing in replacement non return Valve (NRV) size of 50 mm dia suitable for any type/size pipe complete all as specified and directed by Engr-in-Charge
Supply, fixing & testing in replacement water realease valve size of 150 mm dia suitable for any type/size pipe complete all as specified and directed by Engr-in-Charge
Supply, fixing & testing in replacement water realease valve size of 100 mm dia suitable for any type/size pipe complete all as specified and directed by Engr-in-Charge
Supply, fixing & testing in replacement water realease valve size of 80 mm dia suitable for any type/size pipe complete all as specified and directed by Engr-in-Charge
M&L for fixing in replacment Notice board 2 feet by 1 feet using half mm thick foam sheet including writing emergency contact name and Number on board , notice board shall be printed in red color only and letters are white color minimum 76 letters and maximum 90 letters and fixing with revet or screw all as specified and directed by Engr-in-Charge Note : Sample copy shall be collected from site with details all as specified
M&L for fixing in replacment Notice board 6 feet by 4 feet using half mm thick foam sheet including writing of DG set / transformer/AC plant/Pumps details as per given format and shall be printed in blue color only and letters are white color minimum 76 letters and maximum 90 letters and fixing with revet or screw all as specified and directed by Engr-in-Charge Note : Sample copy shall be collected from site with details all as specified
M&L for fixing in replacment Notice board 4 feet by 3 feet using half mm thick foam sheet including writing of particular deatils of E/M installations and shall be printed in blue color only and letters are white color minimum 50 letters and maximum 70 letters and fixing with revet or screw all as specified and directed by Engr-in-Charge Note : Sample copy shall be collected from site with details all as specified
S & F in replacement of digital soft starter suaitable for 15 HP submersible pump including all connection and additional wiring etc all as specified and directed by Engr-in-Charge
S & F in replacement of star delta starter suaitable for 10 to 12.5 HP submersible pump including all connections and additional wiring etc all as specified and directed by Engr-in-Charge
S&F in replacement of Gun Metal Foot valve of following Sizes :-
50 mm bore .
80 mm bore .
150 mm bore .
Attending day to day Street light complaints (Street lights fitted on poles/buildings at heights up to 12 mtr from ground level), repair/replacement of unserviceable accessories like lamps,lamp holders, ballast, ignitor, capacitors, reflectors, acrylic covers, nuts, bolts, clamps ets and repair/replacement of U/S connected accesories like cables, wires, earthing strip, earth wire, feeder piller box including replacing all accessories such as MCB, MCCB's bus bars, HRC fuses, rewirable fuses, contactor, timers, connector, wires, glands, thimbles etc sunday and holidays as when required including all required tools, ladders, labour and all other incidental operations required for execution of maintenance work are included complete all as directed and specifed by Engr-in-Charge. Note: - (a) Cost of spares and accessories will be measured and paid seperatly under relevent items. (b) Cost for taking down and re-fixing new parts shall be deemed to be included in the unit rate quoted. (c) All the fitting of HPSV/MVL/HPL/Halogen and flood light will be cleaned once in a month or when required. The rate for which shall be deemed to be included in this item (d) Contractor is responsible to carried out routine and preventive maintenance as per relevant ISI code and as per IS 1944 (part I &II) 1970 code of practice for lightning.
Supply only HPSV / MH ballast 150watt.
Supply only HPSV/MH ballast 250watt .
Supply only Electronic ballast 36 W
Supply only super imposed ignitor for SON/MH light fitting
Supply only capacitor 20 MFD, 230 volts.
Supply only Lamp holder porcelain threaded type for single ended lamp 70/150 watt SV/MH lamp.
Supply only Lamp holder for retrofit T-5/8/12 TL 14/24/36 watt
Supply only Lamp 150 Watt tubular
Supply only Lamp 250 Watt tubular
Supply only CFL 36W
Supply only MCB SP 06 to 32 Amp 10 KA, 'C' curve 230 .
Supply only MCCB TP 125 Amp, 36KA 4Pole.
Supply only MCB DP 63 Amp 10 KA, 'C' curve 230 Volt .
Supply only MCB TP 63 Amp 10 KA, 'C' curve 230 Volt .
Boring of holes under road/pavement/hard standing or any other situation by manual mean for passing GI pipe 50mm bore grade and making good both the ends all as specified and directed at site. Note: - Cost of GI pipe will be paid seperately.
Cutting of existing road/hard standing for laying cables/pipe including making good the disturbed surface to match with the adjoining surfaces with PCC 1:3:6 C2 using 40mm graded aggregate all as complete and specified
S&F in replacement GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection or fixed to the pole/ wall etc for cable protection . Note: - MS clamps for fixing of GI pipe shall be measuered and paid seperately.
Demolition of cement concrete in ground floors and paving built in cement concrete (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as directed.
M&L for PCC 1:2:4 type B-2 using 40mm grade stone aggregate as in coping of poles including necessary form work and fair finshing to exposed surface without using extra cement complete all as specified.
M&L for PCC 1:3:6 type C-2 using 40mm grade stone aggregate as in foundation for stay assy, repairing of floor/paths, fencing post road cutsetc including necessary form work and fair finshing to exposed surface without using extra cement complete all as specified.
Supply, laying and jointing, in trenches / passing through pipes/ fixing on poles/fixing on wall with saddles in replacement LT under ground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core including including cable connecting lugs, glands, jointing fixing materials after taking out exisisting unserviceable cables.
S&F 2.5 Sqmm, single core Two runs PVC insulated and unsheathed FR cable 1100 Volts grade with multistranded copper conductor and one run of 1.5Sqmm cable for common earth dolly drawn through street light pole including connection from kiosk box to street light fittings all as specified and directed by Engr-in-Charge.
S&F 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart or fixing on wall with saddeles and screws all as directed and as per site requirement, of size 6 sqmm, twin core flat or circular.
M&L for prepration of old street light poles by scraping, cleaning of old surfaces of the existing street light tubular poles of size upto 11 mtr long above ground level including brakcets, arches and sodium/mercury vapour light fittings of any shape and painting with two coats of aluminium paint including marking 30 cm strips on pole in black and yellow colour paint upto 2.1 mtr ht from the pedestal including write number on pole as specified and directed by Engr-in-Charge
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C-1 chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test points. (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
S&F in replacement cable junction box IP-55/IP-65 with metric knockout for cable entry size 210x310x116 mm with terminals including long entry thread metric (with one piece sealing ring) and fixing on pole with 32x6 mm aluminium strip clamp with nuts, bolts and washers , electrical connections all as directed by Engr-in -Charge.
S&F in replacement service bracket for street light fitting made out of 40 mm bore light graded GI pipe of length 1.50 mtr bend/weld to shape at 120 degree for fixing of street light fitting on pole all as specified and as directed by the Engineer-in-charge. Note: - Cost of MS clamp, nuts, bolts and washers will be measured and paid seperately under relevent items
S&F in replacement of Street light fitting LED type, 25 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge
S&F in replacement of Street light fitting LED type, 36 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge
S&F in replacement of Street light fitting LED type, 45 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge
S&F in replacement of Street light fitting LED type, 72 Watts 240 Volts high luminous, energy efficient not less than 100 lm/Watt , including SPD fittings and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge
S&F in replacement of Street light fitting LED type, 100 Watts 240 Volts high luminous , energy efficient not less than 100 lm/Watt , including SPD fittings and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge
S&F in replacement of Street light fitting LED type, 120 Watts 240 Volts high luminous not less than 100 lm/Watt , energy efficient , including SPD fittings and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge
S&F in replacement of smart bright Flood light fitting LED type, 120 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light sleek and robust design for better aesthetics, reliable and sturdy, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge
S&F in replacement of smart bright Flood light fitting LED type, 200 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light sleek and robust design for better aesthetics , reliable and sturdy, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge
S&F in replacement energy efficient post top light fitting on wall/gate 360 digree indirect light with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long LED 40 W black case aluminuim including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed by Engr-in-Charge
S&F in replacment energy efficient post light (bollard light) 360 digree light distribution with IP-65 ,85.5 cm hight and 17.4 cm width fitting on ground , wall etc including excavation and PCC 300cmx300cm and high quality integerated LEDs assure soothing warm white light all night long LED 10 W black case aluminuim , synthetic model Robin including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc all as specified and directedby Engr-in-Charge
Taking down carefully copper/aluminum point wiring (light, Fan, Socket or power) complete, fitting such as switches ceiling roses, pendants, regulators, Sockets etc removing materials at site and making good disturbed surfaces of walls, floors roofs etc all as specified and directed by Engr-in-charge.
Taking down carefully copper/aluminum Sub main wiring of size 1.5/2.5/4/6/10/16/25 Sqmm from surface/concealed /existing conduit of any height removing materials at site and making good disturbed surfaces of walls, floors roofs etc all as specified and directed by Engr- in- charge.
M & L for point wiring with 1.5 Sq.mm (nominal area) pvc unsheathed multi stranded copper conductor pvc insulated 1100 volt FRLS grade drawn through and including PVC casing capping/conduit ISI marked minimum 20mm size and its accessories complete along with 1.5 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface, in walls/ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches, switch socket combinations fan regulators etc., as required with 3 mm thick plastic laminated sheet top cover all as specified and directed by Engr-in-Charge for the following:-
One light /fan/bell point controlled by one switch
One 5 Amps plug point independent board controlled by one switch
One three pin switch socket 5 Amps plug point on same board
All as per item No 117 above but with 2.5 Sqmm single core multi stranded copper conductor for one three pin socket 5 Amps on independent board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly complete all as specifed and directed by Engr-in-Charge.
All as per item No 117 above but with 4 Sqmm single core multi stranded copper conductor for one three pin socket 15 Amps on independent board/ metal clad socket for AC point including continuous earth wire PVC insulated 4Sqmm copper solid conductor to common earth dolly complete all as specifed and directed by Engr-in-Charge.
S&F in replacement of switch piano , flush button type , single pole ,one way15 amps complete all as specified and directed by Engr-in-Charge
S&F in replacement of socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified and directed by Engr-in-Charge
S&F in replacement of bell push switch 5 Amps for electric Bell / Buzzer, ding dong AC 230 Volt single pole complete all as specified and directed at site.
S&F in replacement of electric Bell, ding dong type AC 230 Volt single pole complete all as specified and directed at site.
S&F in replacement of Switch Piano flush button type, single pole, one way 5 Amp complete all as specified and directed at site.
S&F in replacement of socket piano flush type 2-in-1 2/3 pin 5 Amps all as specified and directed by Engr-in-charge.
S&F in replacement of sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 to 32 Amps complete all as specified and directed by Engr-in-charge
S&F in replacement of ceiling rose , surface Bakelite 65 mm x 30 mm , 3 terminals complete all as specified and directed by Engr-in-charge
S&F in replacement of Electronic dimmer type regulator 230 Volt step type complete all as specified and directed by Engr-in-charge
S&F in replacement of Switch socket combination 06 Amps complete all as specified and directed by Engr-in-charge
S&F in replacement of Switch socket combination 15 Amps complete all as specified and directed by Engr-in-charge
M&L for Sub main wiring complete with 2 x 1.5 sqmm , single core , multi stranded copper conductor FR PVC insulated and sheathed cable 1100 Volts grade , drawn in PVC Casing Capping in surface /PVC conduit in concealed/surface (as required) along walls roofs etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly including making of good disturbed surface complete all as specified and directed at site. Note:- (i) All three wire/cable(phase, neutral and earth) should be run through for each individual circuit from the DBs. (ii) Two run of cable and earth conductor be measured as one unit
All as per Srl item No 131 above but 2 x 2.5 Sqmm and 1 x 1.5 Sqmm for Earth wire
All as per Srl item No 131 above but 2 x 4 Sqmm and 1 x 2.5 Sqmm for Earth wire
All as per Srl item No 131 above but 2 x 6 Sqmm and 1 x 4 Sqmm for Earth wire
S&F in replacement of PVC Gang box with 5/15 Amp multipurpose Switch and Socket complete all as specified and directed at site.
All as per item No 135 above but but 5 Amps, 5 Pin
S&F in replacement MCB DP 32 Amps, 240 Volts, 10 KA, 'C' Curve complete all as specified and directed
S&F in replacement MCB DP 40 Amps, 240 Volts, 10 KA, 'C' Curve complete all as specified and directed
S&F in replacement MCB TP 40 to 63 Amps, 240 Volts, 10 KA, 'C' Curve complete all as specified and directed at site.
Taking down old / Unserviceable DB by disconnecting electric connection carefully SPN DBs, Main Switch including old models load star MCBs,Isolators,etc and making good to disturbed surface all as specified and directed by Engr-in-charge.
Taking down Old Unserviceable DBs TPN / Main Switches including old models load star MCBs, isolators,fuses,etc and making good to disturbed surface all as specified and directed by Engr-in-charge.
Supply and fix load line vertical DB TPN 4 way IP 43 IK-09 with metal double door suitable for Provision of MCCB , 36 KA 100 Amp for housing of MCBs complete all as directed by Engineer-in- Charge.
Supply and fix double door DB SPN 4 way IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as directed by Engineer-in- Charge.
Supply and fix in double door DB SPN 8way IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as directed by Engineer-in- Charge.
S&F in replacement of MCCB 415 V, 160 Amps, 36KA 3pole with thimbles/lugs and nut,bolts all as required at site and directed by Engr-in-Charge.
S&F in replacement of MCB TPN 6 to 32 Amps, 440 Volts, 10 kA, 'C'Curve complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB TPN 40 to 63 Amps, 440 Volts, 10 kA, 'C'Curve complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB Four Pole 100 Amps, 440 Volts, 10 kA, 'C'Curve complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SP 6 to 32 Amps, 440 Volts, 10 kA, 'C'Curve complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SP 40 to 63 Amps, 440 Volts, 10 kA, 'C'Curve complete all as specified and directed by Engr-in-Charge.
S & F in replacement LED tube light fitting, 1x18 w, 230v surface / wall mounted LED batten, 2100lm PC Body tube housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. & connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed by Engr-in-Charge
S & F in replacement of LED tube light fitting, 1x20 w, 230v surface / wall mounted LED batten, elegant dia cast for designer homes bright LED source with uniform light out put , 2400 lm , surge protection of 2 KV with wide voltage protection 160-360 V in provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. & connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed by Engr-in-Charge
S & F in replacement LED mirror light fittings 1x12 W, 230v Helios type fitted on wall/surface complete all as specified and directed.
S & F in replacement LED light fitting, 1x33 w, 230v 2x2 recessed mounted general purpose squre shaped luminaries with high transitivity diffuser suitable for office application with profiled & flat diffuser fitted on ceiling connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified directed.
S & F in replacement LED security light fitting, 15 w, 230v .down light recessed mounted general purpose square/round shaped luminaries with high transitivity diffuser suitable for office application with profiled & flat diffuser fitted on ceiling connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified directed.
M&L for taking down unserviciable ceiling fan and rewinding the ceiling fan of 1200 mm sweep complete with super enameled copper wire of required size duly varnished with high quality varnish and testing all as directed by Engineer-in- Charge.
All as per item No 156 above but 1400 mm sweep.
M&L for taking down unserviciable exhaust fan and rewinding the exhaust fan with super enameled copper wire of required size covered with high quality varnish complete of 300 mm sweep (12") including greasing /oiling and testing all as specified and directed by Engineer-in- Charge.
M&L for taking down unserviciable cabin fan / wall mounted fan and rewinding the same with supper enameled copper wire of required size covered with high quality varnish complete including greasing /oiling and testing and refixing the same complete all as specified and directed by the Engr-in-Charge
S&F in replacement bearing of ceiling fans 1200/1400 mm for proper running and testing all as directed by Engr-in-Charge
S&F in replacement Gun metal bushes for ceiling fans of size 1200/1400 mm including oiling and testing for proper running complete all as specified and directed by Engr-in-charge
S&F in replacement rotor shaft of ceiling fans of size 1200 mm sweep all as specified and directed by Engr-in-charge
All as per item No 162 above but 1400 mm sweep
S&F in replacement ceiling fan startor for 200 mm sweep match to existing fan rotor of any make as per site requirement all as specified.
All as per item No 164 above but 1400 mm sweep
M&L for Painting to ceiling fans of any size with two coats of synthetic enamel paint by means of suitable spray gun after cleaning and preparing the surfaces and marking the circular ring line 3 mm thick line with golden colour on bottom centre all as specified and directed
M&L for Painting to Exhaust fan of any size / air circulators with two coats of synthetic enamel paint after cleaning and preparing the the surface.
M&L for Painting to Wall mounted / Cabin Fans with two coats of synthetic enamel paint by means of suitable spray gun after cleaning and preparing the surfaces and marking the circular ring line 3 mm thick line with golden colour on bottom centre all as directed.
S&F in replacement Exhaust fan single phase 1400 RPM 12'' sweep heavy duty complete with louver shutter and incl fixing water proof ply wood 12 mm thick of size 350X350mm for fan base after cutting 300 mm dia of suitable size all as specified and directed Note : Old unsv fan shall be deposited to MES store.
S&F in replacement ventilating fan 250 mm sweep 230Volt AC with sturdy blades fully plastic body complete sound proof incl fixing water proof ply wood 12 mm thick of size 300X300 mm for fan base after cutting 250 mm dia of suitable size all as specified and directed by Engr-in-Charge Note : Old unsv fan shall be deposited to MES store.
S&F in replacment Wall mounted fan, 450mm sweep, single phase, 230 volts, 50 Hz, including fixing on wall with fan clamp/hook, connecting electrically all as directed by the Engr-in-charge Note : Old unsv fan shall be deposited to MES store.
S&F in replacement Ceiling Fan 1200 mm sweep single phase AC Energy saving complete as per manufacturer specification all as specified and directed by Engr-in-Charge Note : Old unsv fan shall be deposited to MES store.
S&F in in replacement Bracket assembly of various sizes as required for hanging ceiling fan with rubber shackle nuts, bolts and split pin all as specified and directed by Engr-in-Charge
S&F in replacement Condenser 2.5 mfd including fixing of clamps with screws, sleeves etc complete all as specified and directed by Engr-in-Charge
S&F in replacement Ceiling fan blades as per existing pattern (set of three) for 1200 sweep complete all as specified and directed by Engr-in-Charge
All as per item No 175 above but 1400 mm sweep
S&F in replacement Fan regulator step type electronic 250 volt complete all as specified and directed by Engr-in-Charge
S&F in replacement down rod of ceiling fan made up to 1 mtr long MS pipe medium grade including two coats of synthetic enamel paint over a coat of red oxide primer with bolts / check nuts, washers etc as per existing size and shape of fans incl new U hook with rubber reel with nut bolt and washer including drilling, threading complete all as specified and directed by Engr-in-Charge
S&F in replacement canopy (set of two) for ceiling fans 1200 mm /1400 mm sweep complete all as specified and directed by Engr-in-Charge
S&F in replacement ceiling fan bottom cover suitable for 1200/1400 mm sweep with existing make and model complete all as specified and directed by Engr-in-Charge
S&F in replacement of ceiling fan Top cover suitable for 1200/1400 mm sweep with existing make and model complete all as specified and directed by Engr-in-Charge
S&F in replacement Exhaust fan blade as per existing make and model of size 300 mm sweep complete all as specified and directed by Engr-in-Charge
S&F in replacement heating element suitbale for geyser of capacity 25 ltrs / 50 ltrs as per existing model at site all as specified and directed by Engr-in-Charge
S&F in replacement thermostat suitbale for geyser of capacity 25 ltrs / 50 ltrs as per existing model at site all as specified and directed by Engr-in-Charge
S&F in replacement including installation of Geyser (Heater water storage type) 50 Ltr Capacity, 240 V energy saving 5 star rating and all features as per manufacturer's specification all as specified and directed by Engr-in-Charge
S&F in replacement including installation of Geyser (Heater water storage type) 25 Ltr Capacity, 240 V energy saving 5 star rating and all features as per manufacturer's specification all as specified and directed by Engr-in-Charge
S&F in replacement Crominium plated stop cock screwed of size 15 mm dia complete all as specified and directed by Engr-in-Charge
S&F in replacement Bib cock brass screwed down for size 15 mm bore all as specified and directed by Engr-in-Charge.
Supply & lay in replacement of GI medium grade pipe of 15mm bore complete including all fitting complete all as specified and directed by Engr-in-Charge
S&F in replacement of PVC connection for geysers of 15 mm size heavy duty 450 mm long with brass nuts, bolts and washers all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC connection for geysers of 15 mm size heavy duty 650 mm long with brass nuts, bolts and washers all as specified and directed by Engr-in-Charge.
Taking down geysers of any type & make after disconnecting the electric supply and water connections plugging the inlet and outlet as required in the building , taking out the copper or steel container ,carefully from the geyser, descaling rectifying leakage by bracing ,repairing the insulating (glass wool) metal ,testing for the required pressure and replacing rubber gaskets with new ones appying one coat of approved paint and refixing the same in position with nuts and washers complete all as directed by engineer in charge.
Kathir Marketing Services
bansal construction
ANITA VARMA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .