Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹24.9 L+₹1.7 L (7.18%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹26.2 L+₹3.0 L (13.0%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Rejected due to highest rate quoted | |
| 4 | L4₹26.7 L+₹3.4 L (14.8%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L4 | Rejected-Finance Rejected due to highest rate quoted | |
| 5 | L5₹28.9 L+₹5.6 L (24.2%)Rejected-Finance | L5 | Rejected-Finance Rejected due to highest rate quoted |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
28 Jul 2023, 6:00 pmClosed
GE (AF) Gurgaon
GE (AF) Gurgaon
REPAIR MAINTENANCE OF PERIMETER SECURITY LIGHTS SEARCH LIGHT SOLAR LIGHTS HIGH MAST LIGHTS AND OTHER CONNECTED WORKS AND REPAIR TO FEEDER PILLARS LT PANELS EARTHING AND LT CABLES ALONGWITH CONNECTED ITEMS AT 2003 STN UNDER GE AF GURGAON
2023_MES_607420_1
GE/GUR-/NIT-17/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹89,000
24 Aug 2023
30 Jun 2023
31 Jul 2023
30 Jun 2023
28 Jul 2023
14 Jul 2023
Amount
Dismantling steel poles/ struts, any size complete all as specified and as directed.
M&L of Steel tubular swaged poles complete in replacement of old & rusted poles with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing in replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply and fixing in replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply and fixing in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply and fixing in replacement LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete. (Excavation & earth work shall be measured separately)
M&L for painting of steel tubular pole (straight and bend on top ) with aluminium powder base paint including painting of barbed wire at the top & ms frame pointer on pole and cable protection pipe and all iron parts of 9/11 mtr long pole complete with two coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including painting of strip (not less than 1 feet width) with white and red colour of synthetic enamel paint along with painting metallic junction box with aluminium paint complete all as specified. Note:- Numbering of pole with red paint on white paint base is deemed to be included in quoted rate.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core complete all as specified and as directed.
M&L for PCC 1:4:8 Concrete 40 mm graded 15cm Depth in bottom of Pit for bed concrete steel tubular pole complete all as specified and as directed.
M&L for PCC 1:3: 6 Concrete 40 mm graded 1.5 Mtr Depth of concrete for fixing of streel light steel tubular pole complete all as specified and as directed.
M&L for PCC 1:2: 4 Concrete 40 mm graded 1.5 Mtr Depth for coping of above ground level of steel pole complete all as specified and as directed.
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and laying sand in trenches for protection of cable sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers all as specified and as directed.
M&L for Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75 Old size bricks for the protection for underground cable complete all as specified and as directed.
S&F in repair GI pipe light grade 50mm bore in trenches/wall/poles for protection of cable complete all as specified and as directed.
Supply and fixing in replacementof 3 Phase automatic timer switch with switches ON/OFF the street lights base on lux level of natural light current rating 40 Amps, 220 Volts, 50 Hz. The sensor based timer should also have over voltage and low voltage trip with auto reset facility the sensor alongwith suitable power contactor, MCB and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade special moulding compounds confirming to IP 65. The contactor MCB and circuit wiring shall have enough capacity to take load of 5/7 KW equally distrubuted over 3 phase complete all as specified and as directed. Make : Healer/Universal Swtich Gear/Kakatiya Note: Copper cable of 4 Sqmm x1core (12 Rm) and fixing timer on wall/pole with the help of faster & ms strip, nut bolt & washer is deemed to be included in quoted rates.
Supply and fixing in replacement of pole mounted junction box for road/street light for 3 phase/4 core made out of strong, durable, 100% shock proof, rust proof, maintenance free & extremly durable boxes made of modern age insulating material such as SHEET MOLDING COMPOUND (SMC) of rectangular size 300X200X105 right hinged with locking arrangement complete all as specified and directed Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection and suitable clamps with nuts and bolts etc for fixing of terminal box to pole complete all as specified and as directed.
M&L for annual maintenance of solar LED street lights - 24 Nos (make: Aura). Replacement or repair to LED luminaire of 30 watts, including repair to its driver, PCB card, sensor, solar photo voltic panel/cell, inbuild Li-on batteries and any physical damage cause to panels, pole, hoding strip, GI supporter strips etc (fabrication of GI/MS frame on site and repairing tilted frames) by deploying authorised rep of Aura solar lightings, complete all as specified and directed Note: (i) Replacement of spare parts is included in quoted rates including battery, driver, PCB card, sensor, connecting terminals,photo voltic cell/panel, LED luminaire of 30 watt. (ii) contractor has to arrange T&P & labour for fabrication on site, repairing any physical damage to Solar street ights. (iii) Visiting charges by technicians is any nos of time included in quoted rates. (iv) Panelity of Rs. 1000 per light per day will recovered from contractor if light not found serviceable.
S&F LED bollard of 9 watt tulip type with soft 360° light, IP 65 protection, Resistant to corrosion for better optics and uniform distribution including making foundation (As per manufacturer specification) for bollard light along with bolt integrated with PCC and nut & washer to tightened bollard light and making provision for cable entry and exit through pcc block, complete all as specified and as directed.
S&F constant current led driver of existing street light model suitable for 30 watt LED street Light complete all as specified and as direct.
S&F constant current led driver model suitable for 45 watt LED street Light complete all as specified and direct.
S&F constant current led driver model suitable for 72 watt LED street Light complete all as specified and direct.
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.
M&L for Taking out the LT Feeder Pillar including disconnecting all connection and refixing tghe same on position after rectification of following defects and testing of LT Feeder pillar outdoor type including replacement of base frame dust proof with bus bar chamber to accommodate 3phase, 415Volt with suitable aluminium busbar as per existing size with connections using aluminium strip of suitable Size, fabricated out of 3.15 mm thick CRCA sheet for outer chamber and 2 mm thick for partition and doors and painting with seven tank process with twin shutter closing & locking arrangements complete and fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation 40 cm above ground level complete all as specified and as directed:-
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
S&F of 3 phase Digital meter having VAF + PF Meter with CTs. Make: L&T Cat No: WL441010OOOO complete all as specified and as directed
S&F of CT's for ammeter of rating 200/5A Make: FTC Cat No: 8504 complete all as specified and as directed
S&F of 1 Phase Indicating lamp LED type of RYB colour for all three phases round in shape of 22.5mm Make: L&T Cat No: AUIL01RED00 complete all as specified and as directed
S&F of Aluminium Bus bar strip of rating 300 Amps @ 3 Kg per strip Make: Hindalco complete all as specified and as directed
M&L for MCCB 400 Amps, 36 KA, 3 pole, 415V, 50Hz front extended spread terminal complete all as specified and directed. Make: ABB cat No: 1SDA054437R1 or equivalent make of L&T/Seimens/Legrands
M&L for MCCB 250 Amps, 36 KA, 3 pole, 415V, 50Hz front extended spread terminal complete all as specified and directed. Make: ABB cat No: 1SDA054437R1 or equivalent make of L&T/Seimens/Legrands
M&L for MCCB 200 Amps, 36 KA, 3 pole, 415V, 50Hz front extended spread terminal complete all as specified and directed. Make: ABB cat No: 1SDA054437R1 or equivalent make of L&T/Seimens/Legrands
M&L for MCCB 160 Amps, 36 KA, 3 pole, 415V, 50Hz front extended spread terminal complete all as specified and directed. Make: ABB cat No: 1SDA054437R1 or equivalent make of L&T/Seimens/Legrands
M&L for MCCB 125 Amps, 36 KA, 3 pole, 415V, 50Hz front extended spread terminal complete all as specified and directed. Make: ABB cat No: 1SDA054437R1 or equivalent make of L&T/Seimens/Legrands
M&L for MCCB 100 Amps, 36 KA, 3 pole, 415V, 50Hz front extended spread terminal complete all as specified and directed. Make: ABB cat No: 1SDA054437R1 or equivalent make of L&T/Seimens/Legrands
M&L for Four Pole onload Changeover 400 A with Advance Neutral Conforms to IS:13947 (Part-3); IEC:60947-3 complete all as specified and directed . Make: Havells Cat no- IHCNFE0400
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
M&L for chemical Earthing with copper earth plate 600 x 600 x 5mm thick buired directly in ground (earth pit not less that 12' deep below ground level ) connected to copper earth strip 32 x 6 mm by means of copper brazing after tighten by bolts, nuts, check nuts and washers of brass from earth pit to test point with protection GI pipe of size 40mm dia light grade and providing masonry enclosure and watering pipe 40mm dia light grade , including wiremesh steel funnel complete with alternate layer of salt crystal (200Kgs), charcol (250Kgs), magnesium sulphate crystal (100 Kgs) in each earth pit, including watering arrangement 200 ltrs for each earth pit all as specifed and directed by Engr-in-charge. Make of GI Pipe is Prakash/Jindal (Note : Copper strip 7.5 mtr included in the quoted rate from earth pit to test point)
Supply , Laying and testing of XLPE insulated and PVC Sheathed , galvanized steel strip or wire armoured , heavy duty electric cable with multi stranded aluminium conductor , 1100 volts grade of size 70 sqmm 4 core complete all as specified & directed by Engineer - In - Charge.
Supply , Laying and testing of XLPE insulated and PVC Sheathed , galvanized steel strip or wire armoured , heavy duty electric cable with multi stranded aluminium conductor , 1100 volts grade of size 35 sqmm 4 core complete all as specified & directed by Engineer - In - Charge.
M&L for carrying out horizontal boring below roads/PCC hard standing/Drain suitable Up to 50 mm dia GI pipe as per site requirement for inserting GI pipe of 50 mm size with a depth upto 1.5m & length of road upto 12m complete all as specified and as directed.
M&L for defect rectification of LT 1100 volt grade cable of any size cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault ; removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of any size . The fault locating equipments will be brought to site within the hours complete all as specified and as directed by EIC. Note: Rates are inclusive of excavation, return refilling of cable at faulty pt in any type of soil by deploying any no of labours and T&P.
Supply & jointing heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 240-300 Sq mm 3.5 core complete all as specified and as directed.
Supply & jointing heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 150-185 Sq mm 3.5 core complete all as specified and as directed.
Supply & jointing heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 70-120 Sq mm 3.5 core complete all as specified and as directed.
B S R Enterprises
Sumit Enterprises
M/S Anand Enterprises
M/s NEERAJ KUMAR
M/S ASHISH AND CO
akhil enterprises
S.Rose Enterprises
Shrikanth Solutions
jay maa engineers
M/s VINOD KUMAR SHARMA
V.K. Enterprises
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .