Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹47.3 L+₹38,062.46 (0.81%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 3 | L3₹47.8 L+₹94,373 (2.01%)Rejected-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 4 | L4₹56.5 L+₹9.6 L (20.5%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L4 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
25 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SATWARI
GE SATWARI
PROVN OF RING MAIN SYSTEM,SECURITY LIGHTS AND LT DISTRIBUTION SYSTEM UNDER GE SATWARI
2020_MES_356098_1
GEJM-52/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SATWARI
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE SATWARI
₹98,000
Yes
7 Aug 2020
27 Jun 2020
27 Jul 2020
27 Jun 2020
25 Jul 2020
11 Jul 2020
60 days
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 15 m in depth for laying of pipes etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft loose soil all as specified and directed.
Returning filling in, trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified.
Removing excavated surplus materials to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
Note for item No 1 to 3 :- During the excavation any damage to the existing services like telephone cable,electric cable, sewage line etc will be repaired by the contractor at his own risk & cost. No extra payment will be born by the dept. on this account.
Material and labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate for supporting of CI/GI pipes,header etc all as specified and directed.
Material and labour for Clear dry and sharp sand as in cushioning layer over and under cable laid in trenches complete all as specified and directed by Engr-in-Charge.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid.
PCC in 1:4:8 type D2 using 40mm graded rushed stone aggregate for foundation filling for bed concrete of poles all as directed.
PCC in 1:3:6 type C-2 using 40 mm graded rushed stone aggregate for foundation filling of poles all as directed.
Supply, laying and testing DI water tubing of size 150mm bore K 9 grade with MS flanged on both ends incl nuts, bolts washer and packing material (Rubber sheet) etc Pipes laid in ground or passing thropugh Yards or on Pillers complete all as specified and as directed .(Earth work shall be measured and paid separately).
Supply and fixing Cast iron sluice valve of 150 mm bore double flanged PN 1.6, conforming to IS 14846 / 2000 with non rising spindle with hand wheel including jointing material rubber insertion packing 6mm thick, nuts, bolts washers all as specified.
M & L for construction of brick masonary valve pit chamber of size 1.2mtrx1.2mtrx1mtr including PCC foundation and brick works and plastering inside including provn of 40x40 angle iron frame with 3mm thick MS sheet and holding and locking arrangement(including lock and 2 keys).
Cutting of existing cast iron pipe line of 150 mm bore in position for inserting of CI Special such as tees,bend,coller,tail piece etc for fixing of sluice valves/for branch connection etc.
Cutting of existing Road any size for passing of under ground pipe line 150 mm bore and making good to its original position as directed by Engr-in-Charge
Material and labour in replacement of DI fitting for DI spigot socketed/ flanged pipe bend (any type radius and angle) tapers any type (straight, bends increasing, decreasing or double socket etc) tee pieces, single branch 'Y' junction double branch cross (all socket or socket spigot or flanged) collars, cap and plugs upto 200 mm bore connection pieces one end flanged and other socket or spigot and bell mouth piece one end flanged and other end tapering as bell mouth complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core multistranded. Make- Havells, Gloster,FINOLEX, KEI INDUSTRIES PVT LTD
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 185 sq. mm 3.5 core.Make- Havells, Gloster,FINOLEX, KEI INDUSTRIES PVT LTD
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm 3 core. Make-Havells, Gloster,FINOLEX, KEI INDUSTRIES PVT LTD
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 150 sq. mm 3 core. Make- Havells, Gloster,FINOLEX, KEI INDUSTRIES PVT LTD
Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm x 2 core .
Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm x 2 core .
Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm x 4 core .
Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm x 3.5 core .
Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core.
Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core.
Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core.
Material and labour for in replacement of Shackle type, porcelain, vitreous, white, brown or green insulators on LT pole including opening of binding wire carefully and rebinding with new binding wire for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel straps of 30 x 3 mm size, 12 mm dia insulator bolts, washers and nuts complete all as specified.
Supply and fix GI pipe light grade 80 mm bore for cable protection fixed on poles or laid in trenches under floor, ducts etc with fixing clamps, nuts bolts etc for cable protection all as specified.
Description all as per ser item No 28 but 50 mm bore.
Supply, installation, testing and commissioning outdoor type LT Feeder Pillar of size 50 cm X 50 cm X 20 cm factory made, dust and vermin proof fabricated out of 3.15 mm thick MS sheet complete with openable shutter in front and rear having proper locking arrangement, duly powder coated and including 400 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect with phase indicator lamps (R, Y. B) – 01 Set. all as specified.
Earthing complete with galvanized steel earth plate electrode 60 cm x60cmX6 mm thick buried directly in ground to a depth not less than 3 mtr below normal ground level with top edge of earth plate at a depth not less than 2.25 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal, magnicium sulphate, common salt and connected with in and including GI strip of size 32x6mm by means of stainless steel bolts, nuts, check nuts and washers connected to Transformers / panels. 40mm bore of GI pipe (light grade) from earth plate up to testing point for protection of GI strip and 20 mm bore GI pipe (medium grade) with wire mesh and funnel for watering including necessary excavation and earth work, (in any type of soil) PCC chamber (1:3:6) type C-2 with RCC cover with suitable size of handle made out of 8mm dia MS bars and angle iron 40 x 40x 3mm frame for cover complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part-I 2009 complete all as specified. RCC cover shall be painted with red paint over a primer coat and the rate include in the unit rate of item.
Supply & Laying PVC insulated electric cable with stranded aluminium conductor rating 1100 volts grade of size 4 sqmm 2 core for making connection of light fittings from pole box to street light fitting and complete all as specified.
Supply & erecting in truly vertical position steel tubular swaged poles 410 SP-22 (8.5 mtrs long) complete with 300 x300x 6 mm thick MS base plate continuously welded at bottom of pole and MS sheet 2 mm thick plug welded at top, bolts, nuts & screws including one coat of red oxide primer and internally bituminous painted including painting with two coats of aluminium paint in black and white strips 30 cm upto 1.5mtr height from top of coping in strips all as directed. Make - National Tubing Co. Note : Earth work & PCC shall be measured & paid for separately.
S&F MCB single pole 'B' Series 240V AC 6 Amp capacity all as specified & directed.
Material and labour in replacement for LED Street lighting 60W LED IP66 New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium with lens and toughened glass type roadway luminaire with high power LEDs as light source including electronic driver 60W LED 6000K. MAKE:- CAT PART NO LSTP-60 CDL - LED of crompton, LHETBXU7PA6J060 OF HAVELLS, LR02-671-XXX-57-XX OF WIPRO
Supply & fixing GI pipe bracket 1.2mtr long, made out of GI pipe light grade 40mm dia bent to required shape,drill,welded of fixing of street light fitting including MS clamps of flat iron(40mmx4mm),nuts,bolts ,washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer,complete all as specified and directed.
Supply & fix junction box of size 250x200x150mm made of MS Sheet 1.6mm thick, front door openable with fixing screw painting with two coats of synthetic enamel paint over a coat or red oxide including alumn bus bar 2 Nos of size 20x3mm mounted on epoxy based post insulators and drilled holes for connection all as required and fixed to poles using MS clamp made out of 25mmx3mm MS strip and nuts & bolts of required size, MCB 10 A single pole as directed by Engr-in-charge.
Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: Single-phase load of 5KW;contactor Rating 40Amps; MCB(sp) Rating 40Amps. MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs(Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. Model no SWADEEP-02EC5KW1P
Supply, installation, testing and commissioning outdoor type,step down transformer 11000/433 volts (at no load) AC, 3 phase 50 Hz capacity 315 KVA, core type, double copper wound,oil immersed,naturally cooled,oil natural, Air natural (ONAN) with external cooling fins, delta connected on primary side (HV) star connected on secondary side (LV) in accordance with vector symbol, DYN 11 (vector group) with neutral brought out on secondary side (LV side) and having tapping at + 2.5% to +7.5% HV side to be changed by means of hand operated off load tap change gear. The maximum temperature rise should not exceed 45 degree celcius in oil and 55 degree celcius in HV.LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celcius. The transformer shall be IS:1180 Part-1:2014 (Level-II) and BEE Certified and shall comprise of the followings:- (a) 03 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete withbushing,copper rods, nuts and washers. (b) One cable box on LT side ( Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with two Nos cable gland suitable for reception/taking out of XLPE insulated heavy duty armoured cable including gland, joint and jointing materials complete.
(c ) Oil conservator with filter type drain valve and oil level gauge. (d) De- hydrating breather with first fill dehydrating agent (silica gel). (e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One Nos 100 mm dia, dial type thermometer , vapor pressure type, having range 0 - 120 degree celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer. (h) Two earthing terminals on tank cover to facilitate fixing of 32 X 6 mm galvanised iron earth strip for earthing of neutral & body. (i) Rating plate and terminal making plate. (j) Oil level gauge. (k) Oil drain/ fillter valve. (l) Lifting lugs. (m) Oil filling hole with cap/plug with connecting plate complete. (n) Air release valve plug. (o) Four plain solid cast steel detachable rollers. (p) Extra bushing for neutral , outside the LT cable box for providing independent earthing for neutral. (q) First filling of new and unused transformer oil IS-35/93 (fourth revision) marked (Make - savita/Power Oil) filtered and tested up to 40 KV dielectric strength at 2.5 mm air gap between testing. Note:- (i) Certificate of dielectric strength shall be submitted by the contractor after filling the oil.
Supply, installetion, testing and commissioning outdoor type,step down transformer 11000/433 volts (at no load) AC, 3 phase 50 Hz capacity 200 KVA, core type, double copper wound,oil immersed,naturally cooled,oil natural, Air natural (ONAN) with external cooling fins, delta connected on primary side (HV) star connected on secondary side (LV) in accordance with vector symbol, DYN 11 (vector group) with neutral brought out on secondary side (LV side) and having tapping at + 2.5% to +7.5% HV side to be changed by means of hand operated off load tap change gear. The maximum temperature rise should not exceed 45 degree celcius in oil and 55 degree celcius in HV.LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celcius. The transformer shall be IS:1180 Part-1:2014 (Level-II) and BEE Certified and shall comprise of the followings:- (a) 03 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete withbushing,copper rods, nuts and washers. (b) One cable box on LT side ( Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with two Nos cable gland suitable for reception/taking out of XLPE insulated heavy duty armoured cable including gland, joint and jointing materials complete. (c ) Oil conservator with filter type drain valve and oil level gauge.
(d) De- hydrating breather with first fill dehydrating agent (silica gel). (e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One Nos 100 mm dia, dial type thermometer , vapor pressure type, having range 0 - 120 degree celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer. (h) Two earthing terminals on tank cover to facilitate fixing of 32 X 6 mm galvanised iron earth strip for earthing of neutral & body. (i) Rating plate and terminal making plate. (j) Oil level gauge. (k) Oil drain/ fillter valve. (l) Lifting lugs. (m) Oil filling hole with cap/plug with connecting plate complete. (n) Air release valve plug. (o) Four plain solid cast steel detachable rollers. (p) Extra bushing for neutral , outside the LT cable box for providing independent earthing for neutral. (q) First filling of new and unused transformer oil IS-35/93 (fourth revision) marked (Make - savita/Power Oil) filtered and tested up to 40 KV dielectric strength at 2.5 mm air gap between testing. Note:- (i) Certificate of dielectric strength shall be submitted by the contractor after filling the oil.
Supply, installetion, testing and commissioning outdoor type,step down transformer 11000/433 volts (at no load) AC, 3 phase 50 Hz capacity 100 KVA, core type, double copper wound,oil immersed,naturally cooled,oil natural, Air natural (ONAN) with external cooling fins, delta connected on primary side (HV) star connected on secondary side (LV) in accordance with vector symbol, DYN 11 (vector group) with neutral brought out on secondary side (LV side) and having tapping at + 2.5% to +7.5% HV side to be changed by means of hand operated off load tap change gear. The maximum temperature rise should not exceed 45 degree celcius in oil and 55 degree celcius in HV.LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celcius. The transformer shall be IS:1180 Part-1:2014 (Level-II) and BEE Certified and shall comprise of the followings:- (a) 03 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete withbushing,copper rods, nuts and washers. (b) One cable box on LT side ( Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with two Nos cable gland suitable for reception/taking out of XLPE insulated heavy duty armoured cable including gland, joint and jointing materials complete. (c ) Oil conservator with filter type drain valve and oil level gauge.
(d) De- hydrating breather with first fill dehydrating agent (silica gel). (e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One Nos 100 mm dia, dial type thermometer , vapor pressure type, having range 0 - 120 degree celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer. (h) Two earthing terminals on tank cover to facilitate fixing of 32 X 6 mm galvanised iron earth strip for earthing of neutral & body. (i) Rating plate and terminal making plate. (j) Oil level gauge. (k) Oil drain/ fillter valve. (l) Lifting lugs. (m) Oil filling hole with cap/plug with connecting plate complete. (n) Air release valve plug. (o) Four plain solid cast steel detachable rollers. (p) Extra bushing for neutral , outside the LT cable box for providing independent earthing for neutral. (q) First filling of new and unused transformer oil IS-35/93 (fourth revision) marked (Make - savita/Power Oil) filtered and tested up to 40 KV dielectric strength at 2.5 mm air gap between testing. Note:- (i) Certificate of dielectric strength shall be submitted by the contractor after filling the oil.
Cross arms bracing support clamps, back plate etc fabricated from structural steel section with bolts, nuts, washers,welding, bending cold or hot,drilling holes for bolts in any shape and size as directed or indicated and painted with one coat of red oxide and two coats of aluminium paints..complete all as sepecified dirceted by Engr-in-charge.
Anti climbing device, spikes type, fabricated out of MS bars (round, square or flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the poles, spike welded to flat iron, including on primer coat, one under coat and two finishing coats of silver aluminium paint including preparation of surfaces..complete all as sepecified dirceted by Engr-in-charge.
Supply & fixing danger notice plate 250 mm x 200 mm made of mild steel sheet 1.6mm thick & vitreous enamelled white on both sides and with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 11 KV as required.complete and all as specified directed by Engr-in-charge.
Air break, gang operated switch with 15 Nos insulators, outdoor type pole, mechanically operated, suitable for vertical operations, single break, provided with locking arrangement (including 50mm Godrej lock with two keys) mounted on and including steel frame and HT post type insulators copper alloy, high pressure, with operating mechanism having operating rod of 20 mm dia GI pipe (medium grade) operating from 1.2m above GL complete including drop out fuses conforming to IS-1318 of 1972, rated voltage 11 KV and for current rating 400 Amp all as specified.
Lightning arrestors (set of three), expulsion type, HT metal oxide surge arrestor polymeric type, complete with all fittings, transmission class rated voltage 125 KV contionous operating voltage at 8/20 impulse, 75 KV discharge capacity 65 Kilo amp suitable for 11000 volts complete all as specified and directed.
S&F outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron with and incl cable pieces of suitable size length and line type vice for 3 core 95 Sqmm to 150 sqmm 3 core XLPE HT cable (kit shall be not older than 3 months from the date of manufacture) complete all as specified and directed.
CELMAC REGD
ANIKET TRADERS
SUMEET TRADING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .