Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | Admitted-Finance |
| 2 | Admitted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Admitted-Finance |
| 3 | Not Admitted-PreQual/Technical | Not Admitted-PreQual/Technical Others-Rejected due to not fulfilled the NIT conditions |
| 4 | Not Admitted-PreQual/Technical | Not Admitted-PreQual/Technical Others-Rejected due to not fulfilled the NIT conditions |
Tender Value
₹18.6 L
EMD Value
₹37,200
Closing Date
10 Mar 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EX. ENGINEER (E AND M) W-S (SOUTH-WEST)/M-9
D BLOCK OHT OPP DESU COLONY JANAKPURI NEW DELHI-58
SITC of EnM equipments and allied works at Dhansa online booster.
2022_DJB_218018_37
N.I.T.No.18(2021-22)/EE(EnM)WS SW/M9 C/oACE M 9
Open Tender
Civil Works
Works
30 days
OFFICE OF THE EX. ENGINEER (E AND M) WS-SW/M-9
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJB EMD Ac No. 50448339804
₹37,200
14 Mar 2022
4 Mar 2022
10 Mar 2022
4 Mar 2022
10 Mar 2022
4 Mar 2022
120 days
S/O horizontal split casing pump with impeller, Neck Ring and casing (CI), shaft & sleeve as per in standard fitted condition suitable for head 30 Mtrs, discharge 1MGD (189 MQPH). Make: Kirloskar/ M&P/DJB approved make.
S/O IE2 Totally enclosed fan cooled squirrel cage flame proof Induction Motor of 40 HP, 1450 rpm, suitable for operation on 415+/-10% V, 3 phase, 50 Hz +/- 5% AC supply with ambient 45 to 50 degree Celsius ambient, Class F insulation with temperature rise limited to class B. Make :-Seimens/CG/KBL/DJB approved makes.
Fabrication of MS Base Frame made from MS Chanel size 125mm x 65mm cross support and also fixing with MS vertical support U channel the foundation bolt to absorb the vibration and 4nos drilling as per existing site required.
S/O CI D/F Sluice Valve 300 mm dia with SS Spindle, PN 1.0 (as per IS:14846) Make: KBL/IVC /VAG/Dorot / DJB Approved Make
S/O CI D/F Sluice Valve -150 mm dia with SS Spindle, 1.0 (as per IS:14846) Make: KBL/IVC /VAG/Dorot/ DJB Approved Make
S/O CI D/F Non-Return Valve 300 mm dia, PN 1.0, (as per IS: 5312) Make: KBL/IVC /VAG/Dorot / DJB Approved Make
S/O CI D/F Sluice Valve -125 mm dia with SS Spindle, 1.0 (as per IS:14846) Make: KBL/IVC /VAG/Dorot/ DJB Approved Make
S/O CI D/F Non-Return Valve 125 mm dia, PN 1.0, (as per IS: 5312) Make: KBL/IVC /VAG/Dorot / DJB Approved Make
S/O Double Flanged MS Pipe of 300 mm dia conforming to IS : 3589 Make : JINDAL/TATA / DJB Approved Make
S/O Double Flanged MS Pipe of 150 mm dia conforming to IS : 3589/3259 Make : JINDAL/TATA / DJB Approved Make
S/O Double Flanged MS Pipe of 125 mm dia conforming to IS : 3589/3259 Make : JINDAL/TATA / DJB Approved Make
Fabrication of various MS standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per site requirement.
S/O nuts bolts and washers of required size.
S/O neoprene packing.
S/O 1.1KV grade Armoured XLPE Cable with Aluminium Conductor ISI MARKED of size 3.5C X 25 sq mm (for incoming) (as per relevant IS specifications) Make : Polycab/Havells/DJB Approved Make
Supply of Pressure gauge for delivery side of the pump along with G.I tubing soldering etc as required. Make: H Guru/Fiebig/DJB Approved
Making of RCC foundation of the pump set by cutting the floor level of the pump house up to suitable depth and refilling it with the help of RCC mixture up to suitable height of the suction line including the cost of plastering of newly made foundation and SS foundation bolts etc as required Size of foundation
Installation and fixing of the above pumpsets on the base frame including jointing the pumpsets with suction/ delivery line with proper alignment. the job also include fixing of Valves , laying of cable and making thimbling of cable on both ends by 50sq. mm 6 Nos thimbles, making connection the pump sets from starter/panel etci/c watch and ward, cartage , painting of the suction delivery lines, CI valves, specials, MS Base Frame with good quality enamel paint after two coats of red oxide primer, loading and unloading taking all safety precaution arrangement, all tools and tackles the work including testing and commissioning all E&M equipment i/c various pumpsets at no load and full load in the presence of Engineer In Charge
Earthing with G.I. earth pipe 4.5 meter long 40 mm dia including accessories and providing masonry elclosure with cover plate having locking arrangements and watering pipe etc. with charcoal/coke and salt as required. (One Panel should have Two separate earthing)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing & fixing of 04 pole ELCB 63 Amp on each Panel. Make :- L&T/Havells/DJB Approved.
Grouting of existing LT Panel with 1:2:4 C:C material. Work includes grouting of both legs with C:C material to provide proper strenght
Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment and will include the following procedures. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a copper ferule crimped to the wire panel size 1600X1200X400mm. Having following components of approved make.
MCCB 415V,TP200-250 Amp with spreader & handle. Make - L&T/Siemens/DJB approved make
MCCB 415V, TP 100Amp With Spreader & handle. Make- L&T/Siemens/DJB approved make
MCB Single pole 6Amp. Make - L&T/Schneider/DJB approved make
MCB Triple pole 32Amp. Make -L&T/Schneider/DJB approved make
MCB Triple pole 63Amp. Make- L&T/Schneider/DJB approved make
Amp. Meter digital Type Make -AE/L&T
Volt Meter0-500V Digital Type Make- AE/L&T
MPP type power capacitor 10Kvar Unit 440V 3phase Make -Epcos/ DJB approved make
Motor protection relay MPR200 Make- L&T/Siemens/DJB approved make
Power contactor 220V 3phase 25Amp. Make- L&T/Schneider
Power contactor 220V 3phase 50Amp. Make-L&T/Schneider
Power contactor 220V 3phase 70Amp. Make-L&T/Schneider
Current Transformer 200/5 Make- AE/ Advance/ Saviour
Current Transformer 100/5 Make- AE/ Advance/ Saviour
Over load relay 30-50A Make- L&T/siemens
Over load relay 9-15A Make- L&T/siemens
Indicating lights LED type RYB & On/OFF Make- FTC/ Havells/ L&T
Star delta timer Make - L&T/Siemens
On load 4pole change over switch 250Amp. Make- Havells/ Advance/ DJB approved make
Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimbles, support insulator on bus bar ,requiredhardwares, control wiring in 1.5sq mm wire complete in all respect .
M G Traders and Engineers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .