Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.4 LAccepted-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹1.1 Cr+₹5.9 L (5.90%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical As per WLR of CESC for Q/E Mar 2021, the firm is having present residual work in hand more than twice their present tendering limit. |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
17 Jul 2021, 6:00 pmClosed
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN RAIGAD - 400704
SPECIAL REPAIRS TO FODC BUILDING NO P-306 AT NAVAL STATION KARANJA
2021_MES_450648_1
84087-K/E8
Open Tender
Civil Works
Item Rate
365 days
NAVAL STATION KARANJA
Please refer tender documents.
8 documents required · 8 mandatory
₹1,000
CWE KARANJA
₹1.9 L
9 Aug 2021
11 Jun 2021
19 Jul 2021
11 Jun 2021
17 Jul 2021
3 Jul 2021
Amount
Chipping and removing carefully concrete work by low impact hammer/ breakar without damaging the structure. Cleaning and disposal of debries out side the premises etc., complete all as specified and as directed by Engr-in-charge. Note: Hard concrete should not be removed by force.
Material and labour to clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc., complete and applying two coats of alkaline rust converting primer on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified and as directed by Engr-in-charge. Make: FEOVERT of Krishna Conchem /Roff rust cleaner of Piddilite /Dr. Fixit Rust removal /ShaliRust of STP Ltd
Material and labour for applying two coats of Epoxy based Zinc primer within a span of four hours over the treated rebars and allow to dry for further six hours. The application shall be by brush and complete all as specified and as directed by Engr-in-charge. Make: Corroseal-ZR of Krishna Conchem /Dr. Fixit Epoxy zinc primer
Material and labour for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete and new concrete by brush application complete all as specified and as directed by Engr-in-charge. Make: Monobond SBR of Krishna Conchem /Dr. Fixit epoxy bonding agent /Shalicrete URP of STP Ltd
Material and labour for building up the profile of structural members by using latex additives (MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5 Cement-15 sand) in damaged areas in 30mm thickness including leveling, profilling etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for applying concrete protection coating on finished structural members exposed to atmosphere complete all as specified and as directed by Engr-in-charge. Make: IPNET of Krishna Conchem /New Coat from Dr. Fixit
Material and labour for drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under:- (i) Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles: Insert 12mm dia Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machined to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC /MS nozzels in these holes with fast-setting epoxy putty and let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also seal the face of the crack with a liberal application of the epoxy putty.
Material and labour for injecting on site mixed cement slurry grout, mixed in specified proportion containing cement, sand and water with addition of plasticizers of approved make and migratory corrosion inhibitors. Water cement ratio shall be varied between 0.5 to 1.0 for each hole. Shrinkage compensating cement slurry shall be mixed to a lump free fresh creamy consistency. Mixing shall be done by mechanical mixer continuously by stirr mechanically to keep cement particles in suspension. Injection of approved/ specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc., complete all as specified and as directed by Engr-in-charge till the grout mix flows out from the nozzle indicating complete filling of grout in the holes. Make: Epoxy grout - Dr. Fixit Epoxy injection /EPCO KP-HP-250 of M/s Krishna Conchem /Shaligrout EI of STP Ltd
Material and labour for injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including, mixing of materials: Mixing of material components (Part A&B) in the required quantities as per manufacturer's instruction by weigh batching. Fill the grouting gun with concrete penetrating corrosion inhibitor. Maintain desired pressure in the gun by air compressor and also maintain the pressure at exit (2 to 3 kg/cm2) by monitoring pressure guage at exit. Grout the material through prefixed nozzles in the structural elements @ 100ml per nozzle. Repeat the process for all the nozzles complete all as specified and as directed by Engr-in-charge. Make: EPCO-KP-100/ Protectsil CIT /Ferogard 903
Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and as directed by Engr-in-charge.
Providing and fixing additional main steel bar or stirrups of designed diameter in various structural elements like column, beams and foundations including drilling, bending, welding and fixing the bars with epoxy putty etc., (Steel provided on the basis of 1% of volume of concrete) complete all as specified and as directed by Engr-in-charge.
Material and labour for providing and applying jacketing around columns with micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete all as specified and as directed by Engr-in-charge. Note: Reinforcement shall be measured and paid separately. (Rates including jacketing, formwork and micro concrete)
Taking down cement plaster on brick walls or stone walls etc., including racking out joint, hacking for key, scrubbing down with water etc., including removing debries directed for a distance max upto 500m complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 20mm thick on fair faces of brick /concrete surfaces with two coats i.e (15mm thick backing coat in CM (1:6) and 5mm thick finishing coat in CM (1:4)), finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. Note: WPC to be measured and paid separately.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6 finished even and smooth (with out using extra cement) with using sagol finish complete all as specified and as directed by Engr-in-charge.
Material and labour for epoxy base joint filler paint on external surfaces of walls to fill the cracks with and including resin and hardner in proportion as per manufacturers instructions complete all as specified and as directed by Engr-in-charge. Make: Pidilite/ Fosrac/ Chemistic
Complete removal of existing treatment on external wall surface by sanding machine or any other mechanical means thereafter washing, rubbing down the surface, in order to remove dust, dirt, loose particles etc. Filling the visible cracks /joints with crack seal caulking compound after cleaning the surface by clean water. Applying a coat of primer (water based primer) and allowing to dry for six hours. Thereafter, apply two coats of water proofing treatment on wall (WB high build anti carbonation cum water proofing) including a coat of exterior grade weather proof acrylic emulsion paint by using Airless Paint Sprayer machine at any height of the building by using scaffolding complete all as specified and as directed by Engr-in-charge. Notes: (i) The material used for the teratment must have crack binding ability, water proofing properties and flexible (i.e cover hairline cracks upto 2mm effectively) and be elastomeric. (ii) External water proofing treatment on wall at any height of the building including acrylic paint shall be applied by mechnaically Airless paint sprayer machine only. Make: Pidilite/ Berger/ Asian Paints/ Chemistic
Material and labour for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer complete all as specified and as directed by Engr-in-charge.
Material and labour for applying 3mm thick wall care putty on new or old plastered surface and prepare the smooth surface with sand paper and applying two coats of oil bound distemper on walls complete all as specified and as directed by Engr-in-charge.
Material and labour for 5mm thick rendering on ceilings in cement mortar 1:4 and finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
Material and labour for three coats of white wash on newly plastered surfaces of ceilings including preparation of surface complete all as specified and as directed by Engr-in-charge.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge.
Demolition of cement concrete (unreinforced) roof or chajja padding of any description and any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-charge.
Material and labour for plain cement concrete 1:3:6 type C-1 (Using 20mm graded crushed stone aggregate) in plinth protection, 75mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3m and at every change of direction and filling the same with and including bitumen and sand 1:3 by weight complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) as in roof/ chajja padding /coving for maintaining roof/ chajja minimum slope 1:6 complete all as specified and as directed by Engr-in-charge.
Material and labour for cutting opening through brick walls built in cement mortar for door, windows or enlarging existing opening, converting window into door openings, etc., or cutting out defective brick work for under pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, and rubbish not exc 50m and depositing where directed complete all as specified and as directed by Engr-in-charge.
Complete removal of existing water proofing treatment of any description and in any position including cleaning, wire brushing, watering, removal of debris upto 1500m distance. Surface to be cleaned thoroughly using mechanical tools and tbe made free of dirt, oil. All cracks be repaired by cutting "V" groove and filling the gap using repair mortar Fibre Reinforced Polymer. Providing 75X75mm Coving/ angle fillet using the above repair mortar using Latex Based Bonding Agent as bond coat. All construction joints be opened 15X15mm and treated with repair mortar Fibre Reinforced Polymer. Honey combing to be pressure grouted with No Shrink cementatious Injection Grout. Water Proofing Application: The surface shall be free from standing water. Priming the surafce with UV stable Polyurethane water proof liquid membrane at 400gm/sqmt diluted with water 1:1. Applying 1st coat of ShaliPrime WP WB at 400gm / Sqmt. Then applying 1st coat of UV stable Polyurethane water proof liquid membrane White at 1Kg/Sqmt. Placing 40 Gsm Geotextile / FG Tissue as reinforcement followed by 2nd coat of UV stable Polyurethane water proof liquid membrane at 1kg/sqmt. Ensuring final curing of 36hrs before carrying any further work. Extending water proofing treatment and terminate at the top of the edge of the parapet wall. Sealing the Groove using repair mortar complete all as specified and as directed by Engr-in-charge. Note: In case of foot traffic for maintenance purpose, a separate walkway of 1m to be made with 40mm interlocking tile over Geotextile Make: ShaliUrethane BTD of M/s STP Limilted/ Sec-I PU500 of M/s SG Corporation/ Impermo 3002 of M/s Pratham Enterprises/ Opty D5HDPU of M/s Optimus Chemicals
Material and labour for brushing neat cement slurry with 3Kg of cement per square metre complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 10mm thick cement plaster in CM 1:3 on roof top surface including WPC by weight of 3% of total cement content complete all as specified and as directed by Engr-in-charge. Note: WPC will be measured and paid separately.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) not exceeding 1.5 sqm each, removing from the site including cutting holes required for taking out existing hold fast etc., complete all as specified and as directed by Engr-in-charge.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 sqm not exceeding 4.0 Sqm each, removing from the site including cutting holes required for taking out existing hold fast etc., complete all as specified and as directed by Engr-in-charge.
Taking down shutters of any description exc 1.00 sqm but not exc 2 Sqm complete all as specified and as directed by Engr-in-charge.
Taking down shutters of any description not exc 1.00 sqm complete all as specified and as directed by Engr-in-charge.
Supply and fix for solid PVC door frame of size 50x47mm made out of 5mm prelaminated PVC sheet and edges will be painted to match with prelaminated sheet, reinforced with MS square tube supplying and fixing in opening as per specification complete all as specified and as directed by Engr-in-charge.
Material and labour for factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face and 2mm prelaminated PVC sheet on back face, supplying and fixing in the frame at site as per specification complete all as specified and as directed by Engr-in-charge.
Supply and fix 2nd class hard wood plain solid straight chowkats and frame of wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed by Engr-in-charge.
Supply and fix flush shutters 30mm thick, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete all as specified and as directed by Engr-in-charge.
Material and labour for painting to new wooden surfaces including prepration applying one coat of pink primer and two coats of synthetic paint complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise specified over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-charge.
Supply and fix for aluminium door /window /ventilator /partition, made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame and necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc., complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, hooks and eyes, peg stays and handles, concealed star lock for aluminium window, mortice lock vertical type size 100mm, 04 lever for door, rubber beading suitable for fixing 4mm/ 5mm thick glass in aluminium window/ doors including connected items, with and including making good to the disturbed portion with its original specifications complete all as specified and as directed by Engr-in-charge.
Supply and fix for 4mm thick sheet glass, figured glass, pinhead type, glazing with oil putty area not exceeding 0.50 Sqm each pane complete all as specified and as directed by Engr-in-charge.
Supply and fix Pre-laminated 18/19 mm thick partilcle baords, exterior grade, prelaminated both sides with decorative choice lamiantions complete all as specified and as directed by Engr-in-charge.
Supply and fix for aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engr-in-charge.
Supply and fix 4 mm thick sheet glass, ordinary quality, glazing with oil putty or with wooden or aluminium beads, area n. exceeding 0.50 Square Metre each pane complete all as specified and as directed.
Supply and fix for aluminium anodised grill of design DG 104 pattern made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm & 1.4mm thick all as per manufactures instructions complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair for aluminium body hydraulic door closer regaulted, designation No.3 universal type, suitable for door shuttes of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and as directed by Engr-in-charge.
Supply and fix butt hinges size 100 extruded aluminium alloy with galvanised mild steel hinges pin anodised and fixed C-21 complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs aluminium handle, cast type anodized size of handle 150mm complete all as specified and as directed by Engr-in-charge.
Supply and fix aluminium anodized, barrel tower bolt of extruded section, length of bolt 150mm complete all as specified and as directed by Engr-in-charge.
Supply and fix 125mm brass double action spring hinges, with phosphor bronze wire wire spring, bright polished complete all as specified and as directed by Engr-in-charge.
Supply and fix extruded brass handles, fabricated type polished size of handle 150mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs extruded brass handles, fabricated type polished size of handle 150mm complete all as specified and as directed by Engr-in-charge.
Supply and fix brass barrel tower bolts, with cast or sheet barrel of extruded section, length of bolt 150mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs brass barrel tower bolts, with cast or sheet barrel of extruded section, length of bolt 150mm complete all as specified and as directed by Engr-in-charge.
Supply and fix rim latch with two levers, of brass body, stove enamelled finish; with brass knob or lever handle and fixed 150mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair rim latch with two levers, of brass body, stove enamelled finish; with brass knob or lever handle and fixed 150mm complete all as specified and as directed by Engr-in-charge.
Material and labour 12mm thick prelaminated particle board, exterior grade, prelaminated both sides with deocrative lamination fixed with screws to timber frame work complete all as specified and as directed by Engr-in-charge.
Supply and fix continuous (piano) hinges, mild steel, bright finish or electro galvanised, width of flap (when opened) 30mm complete all as specified and as directed by Engr-in-charge.
Supply and fix 50mm dia, polished, hardwood knos fixed with screws complete all as specified and as directed by Engr-in-charge.
Supply and fix brass locks, drawer, grade I size 50mm 4 lever complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair 12mm thick vertical toughened glass as in door shutters/ partition with including stainless steel SS-304 patch fitting fixed with anchor fastner, stainless steel handles, each glass panes shall be exceeding 1.5 sqm, but not exceeding 2 sqm each, all edges of glass shall be diamond polished complete all as specified and as directed by Engr-in-charge. Make: Saint Gabain/ Modiguard/ Atul/ Tata
Supply and fix collapsible steel gates, top hungs consisting of channel pickets, provided flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfast and brackets complete all as specified and as directed by Engr-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed by Engr-in-charge.
Supply and fix for framed work such as grills, gratings etc., with ends of bars shouldered and riveted or forged into spikes, framed guard bars, barred iron doors ladders, framed balusters, walkways, railings frame work or water tanks and similar work conforming to Fe-290 gde-E-16 complete all as specified and as directed by Engr-in-charge.
Demolition of brick work or stone boulded masonry built in cement mortar or cement lime mortar complete all as specified and as directed by Engr-in-charge.
Material and labour for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6m mean radius built in CM (1:6) etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for brick work with sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed by Engr-in-charge.
Supply and fix sinks made of stainless steel 1mm thick kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting unions to pipe overall size 495mmX420mm bowl size 410mmX330mmX160mm complete all as specified and as directed by Engr-in-charge.
Supply and fix for 5.5mm thick and 120/125mm wide sheet glass shelf assembly with chromium plated bracket guard and railing 500 /600mm long as in repair complete all as specified and as directed by Engr-in-charge.
Material and labour for 100mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs of soap dish fancy type chromium plated fixed in wall complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs hand shower (Health Faucet) with 15 mm dia, 1.2m long flexible tube and wall hook fixed in pipe complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair bib taps screwed down high pressure with both ends for iron pipe 15mm bore fancy type chromium plated as complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed by Engr-in-charge.
Supply and fix curtain rod 20mm dia of MS powder coated with including PVC brackets, stops, rollers etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs wash down water closet (Pedestal pattern) white with P or S trap including flush pipe of polyethylene of low or high density of PVC, 32mm dia, for low level cistern and plastic water closet seat and cover mild steel chromium plated or aluminised hinging device and connection to low level flushing cistern and flush pipe, etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs vitreous china bowl urinal half stall type (white) minimum with grating and union for discharge pipe including PTMT spreader of any colour for fixing with 15mm dia pipe complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs vitreous china urinal partition white of size 310X700mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs vitreous china wash basin white, flat back size 550X400mm including brackets including cutting for and pinning in ends of brackets or erecting stand including PTMT 32mm waste coupling and waste pipe complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair 15 mm bore pillar tap cast copper alloy fancy type with capstan heads, chromium plated fancy type screwed down high pressure with long screws shanks and nuts complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair stop cock or angle valve cast copper alloy, chromium plated fancy type, screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair tubular towel rail of brass chromium plated, 20mm dia, 'D' type, 60 cm long between flanges complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair towel ring of PTMT fixed with and including chromium plated brass screws and plastic cleats complete all as specified and as directed by Engr-in-charge.
Supply only water proofing compound complete all as specified and as directed by Engr-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc, removal to store complete all as specified and as directed by Engr-in-charge. Note: Measured overall as fixed along the centre line over fittings and accessories.
Supply and fix for PVC (SWR) pipes single socketed in any length with rubber ring joints of 75mm bore fixed in trenches or floor complete all as specified and as directed by Engr-in-charge.
All as per item No.87 here-in-before but as fixed on walls.
All as per item No.87 here-in-before but dia of pipe 110 mm.
All as per item No.87 here-in-before but dia of pipe 110 mm fixed to walls.
Supply and fix PVC (SWR) bends of (any radius) with access door of 75mm bore complete all as specified and as directed by Engr-in-charge.
Supply and fix PVC (SWR) bends of (any radius) 110 mm bore complete all as specified and as directed by Engr-in-charge.
Taking up or down steel tubing and connections 15 mm bore complete all as specified and as directed by Engr-in-charge.
Taking up or down steel tubing and connections 20 mm bore complete all as specified and as directed by Engr-in-charge.
Supply and fix 15 mm dia unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix 20mm dia unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., complete all as specified and as directed by Engr-in-charge.
Dismantling of stone slabs and tiles of any description or thickness in floor aprons, cills etc laid bedded and pointed in any mortar complete all as specified and as directed by Engr-in-charge.
Material and labour for non skid coloured ceremic tiles 7 to 8 mm thick (Square /rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floors over screed bed or bedding layer of morar 15mm in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed by Engr-in-charge.
Material and labour for glazed ceramic tiles in vertical surface 350X250X7mm / 450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering or bedding layer in cement mortar 1:4 complete all as specified and as directed by Engr-in-charge.
Supply and fix vitrified ceramic coloured tiles 10mm thick (square /rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer 15mm thick in CM 1:6 for laying floor finishes. complete all as specified and as directed by Engr-in-charge.
Supply and fix green marble 17/ 18 mm thick machine cut, jointing and pointing with white cement slurry including 20mm thick screed bed or bedding layer of CM 1:6 complete all as specified and as directed by Engr-in-charge.
Material and labour for granite tile of 20mm thick on vertical surfaces such as skirting, dado, steps, wash basin table top, flooring, kitchen slab, machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing over and including rendering 15mm thick back coat in CM 1:6 complete all as specified and as directed by Engr-in-charge.
Supply and fix 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification complete all as specified and as directed by Engr-in-charge.
Supply and fix for solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair aluminium powder coated venetian blinds with chain control (width of slate between 25mm to 50mm) as required size and colour. complete all as specified and as directed by Engr-in-charge.
Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets complete all as specified and as directed by Engr-in-charge.
Supply and fix 10 to 12mm thick plaster of paris sheets fix in ceiling with and including grid made out of angles and tees of 1mm thick GI sheets fixed at not more than 45 cm centre to centre in both directions. Grid secured by vertical tie of GI sheet angle at not more than 1.2m centre to centre in both directions. The veritical tie of GI sheet angle shall be fixed with MS dash through fastners of 8mm dia. The ceiling is to be provided at different profiles like curved, flat, sunk and or raised mouding, the joints shall be filled with plaster of paris complete all as specified and as directed by Engr-in-charge.
Supply and fix false ceiling with armstrong XL 24mm grid system of grid size 600x600mm with 14mm thick ceiling board of RH-90 of armstrong. Grid shall be suspended from ceiling using 4mm dia pre-straighten GI wire with 6mm nylone rawl plug and screws at 1200mm intervals complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair stainless steel hand railing with post as per design made out SS304 complete all as specified and as directed by Engr-in-charge.
Supply and fix stairs (framed) including stringers, treads, landing, balusters, hand rails etc., including cleats, brackets, welding etc., Fe-410W (GdeE-250) quality-B complete all as specified and as directed by Engr-in-charge.
Taking down copper /aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS) 1100 volts grade drawn through concealed PVC rigid conduit (ISI marked) with all accessories including concealed modular metal flush box with modular cover plate and frame as per site requirement and other accessories including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, for one light /fan/bell point controlled by one switch 5 Amp, SP, one way 240 volts complete all as specified and as directed by Engr-in-charge.
All as per item No 112 here-in-before but one light point controlled by 2 way switch SP, 5 Amp, 240 Volts.
All as per item No 112 here-in-before but one 5 Amp, 3 pin socket point on the same board.
All as per item No 112 here-in-before above but one 5 Amp, 3 pin socket point independent.
All as per item No 112 here-in-before but using 2.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable for phase and 2.5 sqmm PVC insulated unsheathed multistanderd copper conductor cable for earth continuity (green colour) for one 3 pin socket outlet 15 Amp multi purpose independent controlled by 15 Amp switch, SP, one way, 240 Volts and socket complete all as specified and as directed by Engr-in-charge.
All as per item No 112 here-in-before but using 4 sqmm (nominal area) for phase and 4 sqmm PVC multistanderd FRLS copper conductor cable for earth continuity (green colour) for one 15 Amp socket point controlled by 15 Amp switch, SP, one way, 240 volts and socket complete all as specified and as directed by Engr-in-charge.
Supply and fix switch modular single pole one way, 6 Amp (ISI marked) complete all as specified and as directed by Engr-in-charge.
Supply and fix switch modular single pole two way, 6 Amp (ISI marked) complete all as specified and as directed by Engr-in-charge.
Supply and fix for bell multi music type AC 230 Volts complete all as specified and as directed by Engr-in-charge.
Supply and fix for modular bell push flush type 6 Amp 1 module complete all as specified and as directed by Engr-in-charge.
Supply and fix switch modular socket 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and as directed by Engr-in-charge.
Supply and fix modular socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and as directed by Engr-in-charge.
Supply and fix modular switch 16 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and as directed by Engr-in-charge.
Supply and fix ceiling rose surface bakelite 65x50mm three terminals (IS marked) complete all as specified and as directed by Engr-in-charge.
Supply and fix modular type fan 5 step regulator for ceiling fan complete all as specified and as directed by Engr-in-charge.
Supply, fixing, stringing and drawing submain wiring with 2 runs of single core 4 sqmm PVC insultaed, unsheathed multi stranded copper concuctor cable, 1100 Volts conforming to IS-694 1990 with ISI mark, drawn through concealed PVC conduit 25mm bore size including one run of 4 sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694-1990 green colour for earth continuity and connecting up to common earth dolly including taking down old unserviceable wiring complete all as specified and as directed by Engr-in-charge. Note: Two run of 4 sqmm and one run of 4 sqmm earth wire will be measured as one running metre.
Supply, fixing, stringing and drawing submain wiring with 2 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper concuctor cable, 1100 Volts conforming to IS-694 1990 with ISI mark, drawn through concealed PVC conduit 25mm bore size including one run of 6 sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694-1990 green colour for earth contuinity and connecting up to common earth dolly including taking down old unserviceable wiring complete all as specified and as directed by Engr-in-charge. Note: Two run of 6 Sqmm and one run of 6 Sqmm earth wire will be measured as one running metre.
Supply, fixing, stringing and drawing submain wiring with 4 runs of single core 10 Sqmm PVC insulated and unsheathed, multi stranded FRLS copper conductor cable using colour code for phase red and neutral black with and including 1x10 Sqmm PVC insulated and unsheathed copper conductor multistranded cable in green colour connected to common earth point and connected to earth dolly, drawn through suitable size of concealed PVC conduit, heavy grade (ISI marked) with and including all accessories etc., in replacement including taking down old unserviceable wiring complete all as specified and as directed by Engr-in-charge. Note: (i) 4 runs of 10 sqmm, 1 run of 10 sqmm earth continuity conductor and suitable size of concealed wiring and accessories shall be measured and paid as one length.
Supply, fixing, stringing and drawing submain wiring with 4 runs of single core 16 Sqmm PVC insulated and unsheathed, multi stranded FRLS copper conductor cable using colour code for phase red and neutral black with and including 1x16 sqmm PVC insulated and unsheathed copper conductor multistranded cable in green colour connected to common earth point and connected to earth dolly, drawn through suitable size of concealed PVC conduit with and including all accessories etc., in replacement complete all as specified and as directed by Engr-in-charge. Note: (i) 4 runs of 16 sqmm, 1 run of 16 sqmm earth continuity conductor and suitable size of concealed wiring and accessories shall be measured and paid as one length.
Supply, fixing, stringing and drawing submain wiring with 4 runs of single core 25 Sqmm PVC insulated and unsheathed, multi stranded FRLS copper conductor cable using colour code for phase red and neutral black with and including 1x25 sqmm PVC insulated and unsheathed copper conductor multistranded cable in green colour connected to common earth point and connected to earth dolly, drawn through suitable size of concealed PVC conduit, heavy grade (ISI marked) with and including all accessories etc., in replacement including taking down old unserviceable wiring complete all as specified and as directed by Engr-in-charge. Note: (i) 4 runs of 25 sqmm, 1 run of 25 sqmm earth continuity conductor and suitable size of concealed wiring and accessories shall be measured and paid as one length.
Taking down old unserviceable earth plug and socket board SPN enclosure with single pole MCB complete all as specified and as directed by Engr-in-charge.
Supply and fix earth plug and socket board SP&N enclosure with single pole and earth metal plug and socket 20A, 240V with and including one MCB SP 20A, 240V complete all as specified and as directed by Engr-in-charge.
Taking down old unserviceable DB SPN/ TPN /VTPN with MCB and MCCB complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement MCB SPN distribution board sheet steel, phosphorised powder painted MCB DBs with busbar neutral link, earth bar and DIN rail conforming to IS, 8 way double door, 230 volts, 50 HZ, AC complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement MCB distribution board TPN, 4 way, 415 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement MCB distribution board TPN, 8 way, 415 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement MCCB distribution board VTPN, 8 way, 415 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement MCCB 4 pole, thermal release range 100 Amps of breaking capacity 25 kA, 415 Volts, 50 Hz, series complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement MCCB 4 pole, thermal release range 125 Amps of breaking capacity 25 kA, 415 Volts, 50 Hz, series complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement MCB SP 240 V, 50 Hz, 10 KA conforming to IS 8828 of rating 6 to 32 Amp, 'C' series complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement SPN MCB 240 V 50 Hz 10 KA confirming to IS 8828 of rating 6 to 40 Amp complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement TPN MCB 415 V 50 Hz 10 KA confirming to IS 8828 of rating 63 Amp complete all as specified and as directed by Engr-in-charge.
Supply and fix replacement TP MCB 415 V 50 Hz 10 KA confirming to IS 8828 of rating 63 Amp complete all as specified and as directed by Engr-in-charge.
Supply and fix recess mounting LED 2 x 2 luminaire white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission acrylic cover and conecting with ceiling rose complete all as specified and as directed by Engr-in-charge.
Supply and fix LED batten with 20W LED tube light in wall /surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc., surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete all as specified and as directed by Engr-in-charge.
Supply and fix LED tube light fitting 1x28 watt pendant type luminaries light fitting complete all as specified and as directed by Engr-in-charge.
Supply and fix recess downlighters with low depth round and larger dia 12 Watt complete all as specified and as directed by Engr-in-charge.
Supply and fixing LED building security light fitting with suitable size bracket/ angle to fit security light of 45W IP 66 protection LED complete all as specified and as directed by Engr-in-charge.
Supply and fix wall light fixtures made up of polycarbonate, suitatable for and including 5 watt LED bulb fixed on wall complete all as specified and as directed by Engr-in-charge.
Taking down PVC insulated XLPE /PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor on wall saddle through necessary arrengements of size 2 core 10 sqmm complete all as specified and as directed by Engr-in-charge.
Refixing of serviceable XLPE /PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor on wall with saddle of size 2 core 10 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fixing, jointing, in surface XLPE /PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches/ ducts of size 2 core 10 sqmm including necessary arrengement of saddle on wall complete all as specified and as directed by Engr-in-charge.
Taking down ceiling fan/ exhaust/ wall fan and keeping in safe custody and refixing the same after duly painted and necessary repair work like greasing work etc., complete all as specified and as directed by Engr-in-charge.
Taking out old indoor type LT panel after disconecting electric supply and removing all connection and keeping at aside for making necessary fixing of items including painting (before painting scraping of old paint) including primer and one coat of synthetic enamel paint and refixing the LT panel at same the place by providing complete wiring of panel board, new thimbles, terminals, cable glands and digital voltmeter and ammeter. The following making arrangements will be done before refixing the LT Panel:- (a) Replacement of Existing MCCB with MCCB 4 Pole 320 Amps, 415 volts, 50 Hz - 01 Nos (b) Spreader Terminals for MCCB 4 pole, DPX3 -630 type Legrand/L&T/ABB /Havells - 01 Set of eight. (c) Making arrangement for installing 02 x MCCB 3 pole 160 Amps (d) Spreader Terminals for MCCB 4 pole, DPX3 -250 type Legrand/L&T/ABB /Havells - 01 Set of six. (e) Multi function meter having LCD Display, 96 x 96 sqmm - 01 No. (f) Current transformer (g) LED indicators (h) CU Bus Bar - 32X5mm Notes: (a) Before taking down proper permission needs to taken by Engr-in-Charge. (b) While refxing proper load distribution to be catered with proper use of multimeter, toungue tester etc., complete all as specified and as directed by Engr-in-charge.
Taking down 3.5 core 70 Sqmm XLPE/ PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor complete all as specified and as directed by Engr-in-charge.
Supply and fixing, jointing, connecting and testing in trenches XLPE /PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches/ ducts of size 3.5 core 95 Sqmm and including necessary arrengement of saddle the cable on wall complete all as specified and as directed by Engr-in-charge.
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick buried directly in ground vertically in a pit of depth not less than 2.25m below ground levels with top edge of the earth plate not less than 1.5m below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point or indicated including testing on completion complete all as specified and as directed by Engr-in-charge. Note: The unit rate includes for protection pipe and lead wire from top of earth plate up to 7.5m above ground level.
Material and labour for GI pipe medium grade 50mm bore with all fittings complete laid in trenches complete all as specified and as directed by Engr-in-charge.
Excavation in trenches for not exc 1.5m wide and not exc 1.5m depth and getting out in soft/ loose soil including taking out faulty cable /cable, cable covers and GI pipe complete all as specified and as directed by Engr-in-charge.
Removing excavated materials not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25cms complete all as specified and as directed by Engr-in-charge.
Supply and lay sand cushioning to under ground LT cable complete all as specified and as directed by Engr-in-charge. Note: Only punned thickness shall be measured for payment.
Supply and laying un-reinforced precast concrete cable cover, of class LV, Type I, flat, size 250X150X40mm complete all as specified and as directed by Engr-in-charge.
Disconnecting carefully split type air conditioning unit of capacity 1.5 Ton, electrically/ mechanically and lowering to the ground from any position, transproting to store yard as provided by user /MES (within 2 KM) for repairing the existing building complete all as specified and as directed by Engr-in-charge.
Disconnecting carefully split type air conditioning unit of capacity 2 Ton, electrically/ mechanically and lowering to the ground from any position, transproting to store yard as provided by user /MES (within 2 KM) for repairing the existing building complete all as specified and as directed by Engr-in-charge.
Disconnecting carefully cassettee type air conditioning unit of capacity 2 Ton, electrically/ mechanically and lowering to the ground from any position, transproting to store yard as provided by user /MES (within 2 KM) for repairing the existing building complete all as specified and as directed by Engr-in-charge.
Disconnecting carefully cassettee type air conditioning unit of capacity 3 Ton, electrically/ mechanically and lowering to the ground from any position, transproting to store yard as provided by user/ MES (within 2 KM) for repairing the existing building complete all as specified and as directed by Engr-in-charge.
Disconnecting carefully window type air conditioning unit of capacity 1.5 Ton, electrically/ mechanically and lowering to the ground from any position, transproting to store yard as provided by user /MES (within 2 KM) for repairing the existing building complete all as specified and as directed by Engr-in-charge.
Re-installation split type AC (indoor and outdoor unit) of capacity 1.5 Ton to the suitable location /wall complete including overhauling, replacement of unserviceable/ burnt out spare parts to make it fully functional top-up of R-22/ R-134(a) gas upto suction pressure 60 PSIG properly, leak testing of complete system after commissioning and checking of room temperature complete as per norms complete all as specified and as directed by Engr-in-charge.
Re-installation split type AC (indoor and outdoor unit) of capacity 2 Ton to the suitable location /wall complete including overhauling, replacement of unserviceable/ burnt out spare parts to make it fully functional top-up of R-22 /R-134(a) gas upto suction pressure 60 PSIG properly, leak testing of complete system after commissioning and checking of room temperature complete as per norms complete all as specified and as directed by Engr-in-charge.
Re-installation cassettee type AC (indoor and outdoor unit) of Capacity 2 Ton to the suitable location /wall complete including overhauling, replacement of unserviceable/ burnt out spare parts to make it fully functional top-up of R-22 /R-134(a) gas upto suction pressure 60 PSIG properly, leak testing of complete system after commissioning and checking of room temperature complete as per norms complete all as specified and as directed by Engr-in-charge.
Re-installation cassettee type AC (indoor and outdoor unit) of capacity 3 Ton to the suitable location /wall complete including overhauling, replacement of unserviceable/ burnt out spare parts to make it fully functional, top-up of R-22/ R-134(a) gas upto suction pressure 60 PSIG properly, leak testing of complete system after commissioning and checking of room temperature complete as per norms complete all as specified and as directed by Engr-in-charge.
Re-installation window AC of capacity 1.5 Ton to the suitable location /wall complete including overhauling, replacement of unserviceable/ burnt out spare parts to make it fully functional top-up of R-22 /R-134(a) gas upto suction pressure 60 PSIG properly, leak testing of complete system after commissioning and checking of room temperature complete as per norms complete all as specified and as directed by Engr-in-charge. Note for Sl No. 165 to 174: Re-installation will be carried out after completion of repairs to the building work or as directed by Engr-in-charge.
Supply and lay PVC drain pipe 15mm dia including clamps and fittings from indoor unit upto drain complete all as specified and as directed by Engr-in-charge.
Supply and fix copper tubing of dia 1/2" for suction line including thermal insulation and other brass fitting, fixing into wall etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix copper tubing of dia 1/4" for discharge line including thermal insulation and other brass fitting, fixing into wall etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix powder coated iron stand for suporting the outer unit of split air conditioning including all accessories such as nuts, bolts, washers, etc., required for fixing/ hanging the stand into the wall complete all as specified and as directed by Engr-in-charge.
Nexus Infratech
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .